Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Active phase correction of high resolution silicon photonic arrayed waveguide gratings

Arrayed waveguide gratings provide flexible spectral filtering functionality for integrated photonic applications. Achieving narrow channel spacing requires long optical path lengths which can greatly increase the footprint of devices. High index contrast waveguides, such as those fabricated in silicon-on-insulator wafers, allow tight waveguide bends which can be used to create much more compact designs. Both the long optical path lengths and the high index contrast contribute to significant optical phase error as light propagates through the device. Thus, silicon photonic arrayed waveguide gratings require active or passive phase correction following fabrication. We present the design and fabrication of compact silicon photonic arrayed waveguide gratings with channel spacings of 50, 10 and 1 GHz. The largest device, with 11 channels of 1 GHz spacing, has a footprint of only 1.1 cm 2 . Using integrated thermo-optic phase shifters, the phase error is actively corrected. We present two methods of phase error correction and demonstrate state-of-the-art cross-talk performance for high index contrast arrayed waveguide gratings. As a demonstration of possible applications, we perform RF channelization with 1 GHz resolution. In addition, we generate unique spectral filters by applying non-zero phase offsets calculated by the Gerchberg Saxton algorithm.

36 MATERIALS SCIENCE↗

Parametric study of optical transmission through plasmonic hole arrays modulated by the phase transition of vanadium dioxide

We have performed comprehensive electromagnetic simulations and preliminary experiments to explore the effects of geometrical and material parameters on the extraordinary optical transmission (EOT) through periodic arrays of subwavelength holes in a bilayer stack consisting of a gold or silver film atop a vanadium dioxide film (Au/Ag + VO 2 ), where the latter undergoes a semiconductor-to-metal phase transition. Using the finite-difference time-domain (FDTD) and finite-element methods (FEM), we vary iteratively the array periodicity, VO 2 film thickness and hole diameters, as well as the refractive index inside the VO 2 -layer holes and the VO 2 optical constants. For each variation, we compare the metallic-to-semiconducting ratios of the zero-order transmission ( T 00 ) peaks and find sharp maxima in these ratios within narrow parameter ranges. The maxima arise from Fabry-Perot and Fano-type resonances that minimize T 00 in the semiconducting phase of the perforated bilayers. At a fixed array period, the primary factors controlling the VO 2 -enabled EOT modulation are the VO 2 thickness, diameter of the VO 2 -layer holes, and absorption in the two VO 2 phases. Besides uncovering the origins of the higher metallic-phase T 00 , this study provides a protocol for optimizing the performance of the bilayer hole arrays for potential uses as dynamically tunable nano-optical devices.

Donev, Eugenii U. (ORCID:000000030555219X)↗

Axiom Microbiome Array, the next generation microarray for high-throughput pathogen and microbiome analysis

Microarrays have proven to be useful in rapid detection of many viruses and bacteria. Pathogen detection microarrays have been utilized to diagnose viral and bacterial infections in clinical samples and to evaluate the safety of biological drug materials. In this study, the Axiom Microbiome Array was evaluated to discover its sensitivity, specificity and utility in microbiome analysis of veterinary clinical samples. The array contains probes designed to detect more than 12,000 species of viruses, bacteria, fungi, protozoa and archaea, yielding the most comprehensive microbial detection platform built to date. The array was able to detect Shigella and Aspergillus at 100 genome copies, and vaccinia virus DNA at 1,000 genome copies. The Axiom Microbiome Array made correct species-level calls in mock microbial community samples. When tested against serum, tissue, and fecal samples from pigs experimentally co-infected with porcine reproductive and respiratory syndrome virus and porcine circovirus type 2, the microarray correctly detected these two viruses and other common viral and bacterial microbiome species. This cost-effective and high-throughput microarray is an efficient tool to rapidly analyze large numbers of clinical and environmental samples for the presence of multiple viral and bacterial pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

A Frequency-Domain-Based Algorithm for Detecting Microseismicity Using Dense Surface Seismic Arrays

We propose a new frequency-domain-based algorithm for detecting small-magnitude seismic events using dense surface seismic arrays. Our proposed method takes advantage of the high energy carried by S waves, and approximate known source locations, which are used to rotate the horizontal components to obtain the maximum amplitude. By surrounding the known source area with surface geophones, we achieve a favorable geometry for locating the detected seismic events with the backprojection method. To test our new detection method, we used a dense circular array, consisting of 151 5 Hz three-component geophones, over a 5 km aperture that was in operation at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) in southcentral Utah. We apply the new detection method during a small-scale test injection phase at FORGE, and during an aftershock sequence of an Mw 4.1 earthquake located ~30 km north of the geophone array, within the Black Rock volcanic field. We are able to detect and locate microseismic events (Mw<0) during injections, despite the high level of anthropogenic activity, and several aftershocks that are missing from the regional catalog. By comparing our method with known algorithms that operate both in the time and frequency domain, we show that our proposed method performs better in the case of the FORGE injection monitoring, and equally well for the off-array aftershock sequence. Our new method has the potential to improve microseismic event detections even in extremely noisy environments, and the proposed location scheme serves as a direct discriminant between true and false detections.

Geochemistry & Geophysics↗

Spatially Dependent Seismic Wavefield Scattering from an Underground Chemical Explosion: Analysis of the Source Physics Experiment Dry Alluvium Geology Large- N Array

Explosion sources have been observed to generate significant shear‐wave energy despite their isotropic nature. To investigate this phenomenon, we conduct an analysis of the seismic data collected as part of the Source Physics Experiment (SPE): Dry Alluvium Geology (DAG) and investigate the generation of shear‐wave energy via scattering. The data were produced by three underground chemical explosions and consist of three‐component seismograms, which were recorded by the DAG Large‐N array. Synthetic tests suggest that for the DAG experiments, small‐scale stochastic heterogeneities, defined as features with correlation lengths of 10–100s of meters, are more effective than large‐scale geologic structure (scales >1–10 km) at reproducing the scattering of explosion generated wavefields observed at DAG. We analyze the seismic data for spatially variable ratios between transversely and radially polarized seismic energy, and then estimate the mean free path of P and S waves. All analyses are conducted within a frequency band of 5–50 Hz. The ratio of transversely to radially polarized energy is the highest in the east and west portion of the Large‐N array. In addition, the magnitude of the estimated S‐wave mean free path is shorter in the eastern portion of the Large‐N array. This variation indicates that the eastern area of the DAG array is where more scattering is occurring, suggesting azimuthal dependence of P‐to‐P and P‐to‐S scattering. Furthermore, this azimuthal dependence of P‐to‐S scattering can have implications for explosion discrimination based on spectral ratios of seismic wave types, because the general assumption is that explosions do not generate shear‐wave energy. Synthetic tests modeling only larger‐scale geologic structure had lower transversely polarized energy (only four stations showing a transversely to radially polarized energy ratio greater than 1) and fewer stations (<10) displaying shorter (<300 m) mean free paths than what was observed in the DAG data results.

Darrh, Andréa Nicole↗

Velocity Structure at the Source Physics Experiment Phase I Site Obtained with the Large-N Array Data

The Source Physics Experiment (SPE) consists of a series of chemical explosions at the Nevada National Security Site. The goal of the SPE is to understand and model seismic-wave generation and propagation from these explosions. To achieve this goal, we need an accurate velocity model of the SPE site. A large-N seismic array deployed at the SPE site during one of the chemical explosions (SPE-5) provides great data for this purpose. The array consists of 996 geophones and covers an area of approximately 2 &times; 2.5 km. In addition to the SPE-5 explosion, the array recorded 53 large weight drops. Using the large-N seismic array recordings, we perform first-arrival analysis and obtain a 2D P-wave velocity model of the SPE site. We image a sharp transition from high-velocity Cretaceous granite to low-velocity Quaternary alluvium. Other geological units such as the Tertiary volcanic rocks and Paleozoic sedimentary rocks are also clearly shown. The results of this work provide important local geological information and will be incorporated into the larger 3D modeling effort of the SPE program to validate the predictive models developed for the site.

58 GEOSCIENCES↗

A Comparison of Machine Learning Methods of Association Tested on Dense Nodal Arrays

The association of phase picks to form events is one of the fundamental components of seismology. Large and dense sensor networks, such as >1000 geophone arrays (and distributed acoustic sensing), offer unique challenges in association due to the vast numbers of observations and high likelihood of errant picks. In addition, the large number of stations can greatly increase the time it takes to perform the association. For this reason, machine learning (ML) methods might provide a more optimal method of association for such networks. In this work, we examine how well ML methods (e.g., Gaussian mixture model association, PhaseLink, and Graph Earthquake Neural Interpretation Engine) can incorporate dense seismic arrays into regional networks and how well they handle the increasing numbers of stations. Here, we test their capabilities on two dense seismic deployments, one within Rock Valley Nevada (52 nodes and a 9-station sparse local network), and the LArge-n Seismic Survey in Oklahoma dense nodal array (>1800 vertical-component geophones). Processing data from these two different styles of dense seismic deployments allows testing of how the ML algorithms can merge array data with a broader regional network, how they deal with poorly picked phases, and how they handle anthropogenic noise. We compare the ML-associated bulletins to those obtained using the Rapid Earthquake Association and Location algorithm, a more traditional method of association. We find that there are very small differences in results between the methods for small networks (<100 stations) with low pick rates. For large networks (>1000), there are enough errant picks that some of the ML methods start to create false events out of noise. We also find that the ML methods vary in computation time significantly but are all faster than the traditional method tested here.

58 GEOSCIENCES↗

CONCRETE REFLECTED ARRAYS OF U(93.2) METAL

During the period from 1963 – 1973, experiments involving highly enriched uranium units were performed at the Oak Ridge National Laboratory Critical Experiments Facility to determine various critical configurations of three-dimensional arrays. The experiments formed a four-part series, and were reported by several different experimenters; the results of interest for this evaluation are those reported for the fourth experimentation, Critical Three-Dimensional Arrays of Neutron Interacting Units: Part IV, published and performed by D.W.Magnuson (Ref 1). Information is also available in the logbook . This set of experiments utilized subcritical metal units on a split table apparatus to determine critical configurations for 2×2×2 arrangements of highly enriched uranium reflected by concrete. Magnuson manipulated the configuration of several uranium cylinders and blocks within a concrete reflector. The different permutations utilized uranium cylinders of two different heights in various positions in the three dimensional array; certain cases also placed thin uranium blocks on top of the cylinders. The thickness of the surrounding concrete, as well as the inner dimensions of the concrete reflector was also varied in certain cases. The variations resulted in fourteen different experimental permutations or configurations. All fourteen configurations were judged to be unacceptable for use as criticality safety benchmarks. All experiments were initially evaluated; however only three configurations were evaluated in detail. Configurations 2, 4, 6 and 12 were not evaluated in detail because they are subcritical and configurations 5, 7, 8, 9, and 10 were also were not evaluated in detail because they were supercritical by more than beta effective (~0.007), or prompt critical. The experiments evaluated in detail for this benchmark were configurations 1, 3, and 11. The experimental report also contains the information for HEU-MET-FAST-056. Closely related work has been recorded in HEU-MET-FAST-053, which is a benchmark evaluation of a different series of three dimensional array experiments with four different moderator materials. HEU-MET-FAST-023 and HEU-MET-FAST-026 are also related because they utilize the same metal cylinders as these experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Small Area Array-Based LED Luminaire Design

This report contains a summary of technical achievements during a three-year project to demonstrate high efficiency LED luminaire designs based on small area array-based gallium nitride diodes. Novel GaN-based LED array designs are described, specifically addressing the thermal, optical, electrical and mechanical requirements for the incorporation of such arrays into viable solid-state LED luminaires. This work resulted in the demonstration of an integrated luminaire prototype of 1000 lumens cool white light output with reflector shaped beams and efficacy of 89.4 lm/W at CCT of 6000oK and CRI of 73; and performance of 903 lumens warm white light output with reflector shaped beams and efficacy of 63.0 lm/W at CCT of 2800oK and CRI of 82. In addition, up to 1275 lumens cool white light output at 114.2 lm/W and 1156 lumens warm white light output at 76.5 lm/W were achieved if the reflector was not used. The success to integrate small area array-based LED designs and address thermal, optical, electrical and mechanical requirements was clearly achieved in these luminaire prototypes with outstanding performance and high efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LDRD final report : chromophore-functionalized aligned carbon nanotube arrays.

The goal of this project was to expand upon previously demonstrated single carbon nanotube devices by preparing a more practical, multi-single-walled carbon nanotube (SWNT) device. As a late-start, proof-of-concept project, the work focused on the fabrication and testing of chromophore-functionalized aligned SWNT field effect transistors (SWNT-FET). Such devices have not yet been demonstrated. The advantages of fabricating aligned SWNT devices include increased device cross-section to improve sensitivity to light, elimination of increased electrical resistance at nanotube junctions in random mat devices, and the ability to model device responses. The project did not achieve the goal of fabricating and testing chromophore-modified SWNT arrays, but a new SWNT growth capability was established that will benefit future projects. Although the ultimate goal of fabricating and testing chromophore-modified SWNT arrays was not achieved, the work did lead to a new carbon nanotube growth capability at Sandia/CA. The synthesis of dense arrays of horizontally aligned SWNTs is a developing area of research with significant potential for new discoveries. In particular, the ability to prepare arrays of carbon nanotubes of specific electronic types (metallic or semiconducting) could yield new classes of nanoscale devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multinozzle Emitter Arrays for Nanoelectrospray Mass Spectrometry

Mass spectrometry (MS) is the enabling technology for proteomics and metabolomics. However, dramatic improvements in both sensitivity and throughput are still required to achieve routine MS-based single cell proteomics and metabolomics. Here, we report the silicon-based monolithic multinozzle emitter array (MEA), and demonstrate its proof-of-principle applications in high-sensitivity and high-throughput nanoelectrospray mass spectrometry. Our MEA consists of 96 identical 10-nozzle emitters in a circular array on a 3-inch silicon chip. The geometry and configuration of the emitters, the dimension and number of the nozzles, and the micropillar arrays embedded in the main channel, can be systematically and precisely controlled during the microfabrication process. Combining electrostatic simulation and experimental testing, we demonstrated that sharpened-end geometry at the stem of the individual multinozzle emitter significantly enhanced the electric fields at its protruding nozzle tips, enabling sequential nanoelectrospray for the high-density emitter array. We showed that electrospray current of the multinozzle emitter at a given total flow rate was approximately proportional to the square root of the number of its spraying-nozzles, suggesting the capability of high MS sensitivity for multinozzle emitters. Using a conventional Z-spray mass spectrometer, we demonstrated reproducible MS detection of peptides and proteins for serial MEA emitters, achieving sensitivity and stability comparable to the commercial capillary emitters. Our robust silicon-based MEA chip opens up the possibility of a fully-integrated microfluidic system for ultrahigh-sensitivity and ultrahigh-throughput proteomics and metabolomics.

47 OTHER INSTRUMENTATION↗

Wave Energy Converter (WEC) Array Effects on Wave Current and Sediment Circulation: Monterey Bay CA.

The goal s of this study were to develop tools to quantitatively characterize environments where wave energy converter ( WEC ) devices may be installed and to assess e ffects on hydrodynamics and lo cal sediment transport. A large hypothetical WEC array was investigated using wave, hydrodynamic, and sediment transport models and site - specific average and storm conditions as input. The results indicated that there were significant changes in sediment s izes adjacent to and in the lee of the WEC array due to reduced wave energy. The circulation in the lee of the array was also altered; more intense onshore currents were generated in the lee of the WECs . In general, the storm case and the average case show ed the same qualitative patterns suggesting that these trends would be maintained throughout the year. The framework developed here can be used to design more efficient arrays while minimizing impacts on nearshore environmen ts.

Roberts, Jesse D.↗

Design of 3x3 Focusing Array for Heavy Ion Driver Final Report on CRADA TC-02082-04

This memo presents a design of a 3x3 quadrupole array for HIF. It contains 3 D magnetic field computations of the array build with racetrack coils with and without different shields. It is shown that it is possible to have a low error magnetic field in the cells and shield the stray fields to acceptable levels. The array design seems to be a practical solution to any size array for future multi-beam heavy ion fusion drivers.

42 ENGINEERING↗

Stilbene Scintillator Detector Array and Data-Acquisition System for Active Interrogation

A large area Stilbene crystal detector array has been assembled and calibrated for use in active interrogation measurements. The array consists of 10 high-efficiency 4”x2” stilbene cells. The cells were grown by Inrad Optics using LLNL developed technology. The array can be used to detect multiple signatures of SNM items, both actively and passively. Prompt and delayed gamma rays as well as prompt and delay neutrons can be detected and counted separately. The array is coupled to the Mesytec MDPP-16 VME-based digitizer module for data acquisition. This module performs on-board pulse-shape discrimination of signals from the Stilbene crystal detectors. This data-acquisition module allows separation of neutron and gamma-ray events with a low demand on data transfer rates. In addition, the high-resolution timing (<100 ps) is suitable for correlated gamma-ray and neutron multiplicity counting. This report describes the construction and calibration of the system. We also discuss applications of the system as well as how the system is currently being utilized by end users.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thrifty Array Format (TAF) file specifications

Thrifty Array Foram (TAF) files store numeric data in a binary format, minimizing storage requirements while preserving quick read access. Real data of any size and dimensionality can be stored in this format at varying degrees of numeric precision. Implicit array are associated with each dimension, eliminating the need to explicitly store uniformly-spaced grid vectors. Unlimited text comments may be included with the array for user documentation, and every file begins with a text synopsis of the binary structure. The format is deliberately designed for memory mapping, where portions of the array can be read without loading the entire file at once.

97 MATHEMATICS AND COMPUTING↗

Confinement Exploiting Arrays of Cross-Flow Turbines (ConExT) (Final Scientific/Technical Report)

Final technical report for the ARPA-E SHARKS project: Confinement Exploiting Arrays of Cross-Flow Turbines (ConExT). This involved collaboration by the University of Washington, University of Wisconsin, National Renewable Energy Laboratory, and Oberon Insights. Cost-effective, large-scale utilization of tidal and river current resources requires turbine arrays. Most array concepts involve multiple, staggered rows of turbines analogous to wind farms. However, in water, turbines that have an appreciable projected area (i.e., the projected area over a full revolution) relative to a channel’s cross-sectional area can theoretically extract far more energy than when operating in isolation. This suggests substantial benefits to a confinement-exploiting approach to array layout, in which turbines are more densely clustered in a single row spanning a channel. The objective of this project was to move this concept from theory to practice, as well as establishing environmental and economic trade-offs. This objective was accomplished through scale-model experimentation, high-fidelity computational fluid dynamic simulation, and integrated techno-economic modeling.

16 TIDAL AND WAVE POWER↗

Photoelectrochemistry of Semiconductor Nanowire Arrays

This project supported research on the growth and photoelectrochemical characterization of semiconductor nanowire arrays, and on the development of catalytic materials for visible light water splitting to produce hydrogen and oxygen. Silicon nanowires were grown in the pores of anodic aluminum oxide films by the vapor-liquid-solid technique and were characterized electrochemically. Because adventitious doping from the membrane led to high dark currents, silicon nanowire arrays were then grown on silicon substrates. The dependence of the dark current and photovoltage on preparation techniques, wire diameter, and defect density was studied for both p-silicon and p-indium phosphide nanowire arrays. The open circuit photovoltage of liquid junction cells increased with increasing wire diameter, reaching 350 mV for micron-diameter silicon wires. Liquid junction and radial p-n junction solar cells were fabricated from silicon nano- and microwire arrays and tested. Iridium oxide cluster catalysts stabilized by bidentate malonate and succinate ligands were also made and studied for the water oxidation reaction. Highlights of this project included the first papers on silicon and indium phosphide nanowire solar cells, and a new procedure for making ligand-stabilized water oxidation catalysts that can be covalently linked to molecular photosensitizers or electrode surfaces.

08 HYDROGEN↗