Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACCELERATOR MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

The acceleration of ions and electrons by electromagnetic ion cyclotron waves

Test particle calculations of the interaction of electrons and ions with electromagnetic ion cyclotron waves are examined. It is observed that field-aligned electrons can be accelerated parallel to the magnetic fields by the cyclotron waves and that the ions can be accelerated perpendicular to the magnetic field. The data reveal that the ions can be accelerated more effectively when the wave frequency is half (.5) the ion gyrofrequency.

Temerin, M.↗

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan II (PIP-II) project is a vital upgrade to the Fermilab accelerator complex. The magnet pulse rate of the PIP-II Injection system requires an increase from the current rate of 15 Hz to 20 Hz as well as a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) pulsed dipole magnets in the Booster. Here, the ORBUMP magnet mechanical design is presented in this paper. The ORBUMP magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic magnesium phosphate coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled, single turn coil, which shapes the magnetic field by acting as the pole tips, is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The coil is electrically isolated from the core using virgin Polyether ether ketone (PEEK) insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted via partial discharge testing using a 1:1 scale sample.

Karas, D. [Fermi National Accelerator Laboratory (↗

Simulation of Relativistic Shocks and Associated Self-Consistent Radiation

Recent PIC simulations of relativistic electron-positron (electron-ion) jets injected into a stationary medium show that particle acceleration occurs at shocked regions. Simulations show that the Weibel instability is responsible for generating and amplifying highly nonuniform, small-scale magnetic fields and particle acceleration. These magnetic fields contribute to the electron's transverse deflection behind the shock. The "jitter" radiation from deflected electrons in turbulent magnetic fields has different properties than synchrotron radiation, which is calculated in a uniform magnetic field. This jitter radiation may be important for understanding the complex time evolution and/or spectral structure in gamma-ray bursts, relativistic jets in general, and supernova remnants. We will present detailed spectra for conditions relevant of various astrophysical sites of shock formation via the Weibel instability. In particular we will discuss the application to GRBs and SNRs.

Nishikawa, K.-I.↗

A novel electron gun for inline MRI-linac configurations

Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T magnet without capture efficiency reduction below the experimental value in zero field. In this range of linac displacements, the electron beam generated by the new gun geometry is more effectively injected into the linac in the presence of an external magnetic field, resulting in approximately 20% increase of the target current compared to the original gun geometry behavior at zero field. The new gun geometry can generate and accelerate electron beams in external magnetic fields without current loss for fields higher than 0.11 T. The new electron-gun geometry is robust enough to function in the fringe fields of the other two magnets with a target current loss of no more than 16% with respect to the current obtained with no external magnetic fields. Conclusions: In this work, a specially designed electron gun was presented which can operate in the presence of axisymmetric strong magnetic fringe fields of MRI magnets. Computer simulations show that the electron gun can produce high quality beams which can be injected into a straight through linac such as Varian 600C and accelerated with more efficiency in the presence of the external magnetic fields. Also, the new configuration allows linac displacements along the magnet axis in a range equal to the diameter of the imaging spherical volume of the magnet under consideration. The new electron gun-linac system can function in the fringe field of a MRI magnet if the field strength at the cathode position is higher than 0.11 T. The capture efficiency of the linac depends on the magnetic field strength and the field gradient. The higher the gradient the better the capture efficiency. The capture efficiency does not degrade more than 16%.

43 PARTICLE ACCELERATORS↗

Experimental Mapping and Benchmarking of Magnetic Field Codes on the LHD Ion Accelerator

For the validation of the numerical models used for the design of the Neutral Beam Test Facility for ITER in Padua [1], an experimental benchmark against a full-size device has been sought. The LHD BL2 injector [2] has been chosen as a first benchmark, because the BL2 Negative Ion Source and Beam Accelerator are geometrically similar to SPIDER, even though BL2 does not include current bars and ferromagnetic materials. A comprehensive 3D magnetic field model of the LHD BL2 device has been developed based on the same assumptions used for SPIDER. In parallel, a detailed experimental magnetic map of the BL2 device has been obtained using a suitably designed 3D adjustable structure for the fine positioning of the magnetic sensors inside 27 of the 770 beamlet apertures. The calculated values have been compared to the experimental data. The work has confirmed the quality of the numerical model, and has also provided useful information on the magnetic non-uniformities due to the edge effects and to the tolerance on permanent magnet remanence.

43 PARTICLE ACCELERATORS↗

Reconnection and particle acceleration in 3D current sheet evolution in moderately-magnetized astrophysical pair plasma

Magnetic reconnection, a plasma process converting magnetic energy to particle kinetic energy, is often invoked to explain magnetic energy releases powering high-energy flares in astrophysical sources including pulsar wind nebulae and black hole jets. Reconnection is usually seen as the (essentially 2D) nonlinear evolution of the tearing instability disrupting a thin current sheet. To test how this process operates in 3D, we conduct a comprehensive particle-in-cell simulation study comparing 2D and 3D evolution of long, thin current sheets in moderately-magnetized, collisionless, relativistically-hot electron- positron plasma, and find dramatic differences. We first systematically characterize this process in 2D, where classic, hierarchical plasmoid-chain reconnection determines energy release, and explore a wide range of initial configurations, guide magnetic field strengths, and system sizes. We then show that 3D simulations of similar configurations exhibit a diversity of behaviours, including some where energy release is determined by the nonlinear relativistic drift-kink instability. Thus, 3D current-sheet evolution is not always fundamentally classical reconnection with perturbing 3D effects, but, rather, a complex interplay of multiple linear and nonlinear instabilities whose relative importance depends sensitively on the ambient plasma, minor configuration details, and even stochastic events. It often yields slower but longer-lasting and ultimately greater magnetic energy release than in 2D. Intriguingly, nonthermal particle acceleration is astonishingly robust, depending on the upstream magnetization and guide field, but otherwise yielding similar particle energy spectra in 2D and 3D. Though the variety of underlying current-sheet behaviours is interesting, the similarities in overall energy release and particle spectra may be more remarkable.

Gregory R. Werner↗

Electron trapping in evolving coronal structures during a large gradual hard X-ray/radio burst

Gradual hard X-ray/radio bursts are characterized by their long duration, smooth time profile, time delays between peaks at different hard X-ray energies and microwaves, and radiation from extended sources in the low and middle corona. Their characteristic properties have been ascribed to the dynamic evolution of the accelerated electrons in coronal magnetic traps or to the separate acceleration of high-energy electrons in a 'second step' process. The information available so far was drawn from quality considerations of time profiles or even only from the common occurrence of emissions in different spectral ranges. This paper presents model computations of the temporal evolution of hard X-ray and microwave spectra, together with a qualitative discussion of radio lightcurves over a wide spectral range, and metric imaging observations. The basis hypothesis investigated is that the peculiar 'gradual' features can be related to the dynamical evolution of electrons injected over an extended time interval in a coronal trap, with electrons up to relativistic energies being injected simultaneously. The analyzed event (26 April. 1981) is particularly challenging to this hypothesis because of the long time delays between peaks at different X-ray energies and microwave frequencies. The observations are shown to be consistent with the hypothesis, provided that the electrons lose their energy by Coulomb collisions and possibly betatron deceleration. The access of the electrons to different coronal structures varies in the course of the event. The evolution and likely destabilization of part of the coronal plasma-magnetic field configuration is of crucial influence in determining the access to these structures and possibly the dynamical evolution of the trapped electrons through betatron deceleration in the late phase of the event.

Bruggmann, G.↗

Linear Induction Accelerator Cell Voltage Calibration Using Compact Electron Permanent Magnet Spectrometer

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the electron beam energy. Axis-1 of DARHT produces a 20 MeV, 2 kA, 80-ns-FWHM electron beam. Electronic measurement with cell-voltage monitors which consists of a 75 ohm load resistor and a current viewing resistor (CVR) that are coupled together and injector capacitive monitors (EVACSUM) are summed to give the total beam energy at the output of the accelerator. Calibration of these monitors was last done in 1999 and is needed. Using the Compact electron Permanent Magnet Spectrometer (CePMSpec), we have developed a technique for measuring and adjusting the calibration of the accelerator cell load resistor/CVR by using the total energy of the beam. Each pair of cells is driven by pulsed power Blumleins, and each Blumlein is charged by a Blumlein Charge Unit (BCU). There are 64 cells and 32 Blumleins and BCUs. This technique is applied to all 32 BCUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of field errors for LARP Nb 3 Sn HQ03 quadrupole magnet

The U.S. LHC Accelerator Research Program, in close collaboration with CERN, has developed three generations of high-gradient quadrupole (HQ) Nb 3 Sn model magnets, to support the development of the 150 mm aperture Nb 3 Sn quadrupole magnets for the High-Luminosity LHC. The latest generation, HQ03, featured coils with better uniformity of coil dimensions and properties than the earlier generations. We tested the HQ03 magnet at FNAL, including the field quality study. The profiles of low-order harmonics along the magnet aperture observed at 15 kA, 1.9 K can be traced back to the assembled coil pack before the magnet assembly. Based on the measured harmonics in the magnet center region, the coil block positioning tolerance was analyzed and compared with earlier HQ01 and HQ02 magnets to correlate with coil and magnet fabrication. Our study the capability of correcting the low-order non-allowed field errors, magnetic shims were installed in HQ03. Furthermore, the expected shim contribution agreed well with the calculation. For the persistent-current effect, the measured a4 can be related to 4% higher in the strand magnetization of one coil with respect to the other three coils. Lastly, we compare the field errors due to the inter-strand coupling currents between HQ03 and HQ02.

43 PARTICLE ACCELERATORS↗

Interplanetary Mesoscale Observatory (InterMeso): A Mission to Untangle Dynamic Mesoscale Structures Throughout the Heliosphere

Mesoscale dynamics are a fundamental process in space physics, but fall within an observational gap of current and planned missions. Particularly in the solar wind, measurements at the mesoscales (100s RE to a few degrees heliographic longitude at 1 au) are crucial for understanding the connection between the corona and an observer anywhere within the heliosphere. Mesoscale dynamics may also be key to revealing the currently unresolved physics regulating particle acceleration and transport, magnetic field topology, and the causes of variability in the composition and acceleration of solar wind plasma. Studies using single-point observations do not allow for investigations into mesoscale solar wind dynamics and plasma variability, nor do they allow for the exploration of the sub-structuring of large-scale solar wind structures like coronal mass ejections (CMEs), co-rotating/stream interaction regions (CIR/SIRs), and the heliospheric plasma sheet. To address this fundamental gap in our knowledge of the heliosphere at these scales, the Interplanetary Mesoscale Observatory (InterMeso) concept employs a multi-point approach using four identical spacecraft in Earth-trailing orbits near 1 au. Varying drift speeds of the InterMeso spacecraft enable the mission to span a range of mesoscale separations in the solar wind, achieving significant and innovative science return. Simultaneous, longitudinally-separated measurements of structures co-rotating over the spacecraft also allow for disambiguation of spatiotemporal variability, tracking of the evolution of solar wind structures, and determination of how the transport of energetic particles is impacted by these variabilities.

solar wind↗

Interplanetary Mesoscale Observatory (InterMeso): A mission to untangle dynamic mesoscale structures throughout the heliosphere

Mesoscale dynamics are a fundamental process in space physics, but fall within an observational gap of current and planned missions. Particularly in the solar wind, measurements at the mesoscales (100s RE to a few degrees heliographic longitude at 1 au) are crucial for understanding the connection between the corona and an observer anywhere within the heliosphere. Mesoscale dynamics may also be key to revealing the currently unresolved physics regulating particle acceleration and transport, magnetic field topology, and the causes of variability in the composition and acceleration of solar wind plasma. Studies using single-point observations do not allow for investigations into mesoscale solar wind dynamics and plasma variability, nor do they allow for the exploration of the sub-structuring of large-scale solar wind structures like coronal mass ejections (CMEs), co-rotating/stream interaction regions (CIR/SIRs), and the heliospheric plasma sheet. To address this fundamental gap in our knowledge of the heliosphere at these scales, the Interplanetary Mesoscale Observatory (InterMeso) concept employs a multi-point approach using four identical spacecraft in Earth-trailing orbits near 1 au. Varying drift speeds of the InterMeso spacecraft enable the mission to span a range of mesoscale separations in the solar wind, achieving significant and innovative science return. Simultaneous, longitudinally-separated measurements of structures co-rotating over the spacecraft also allow for disambiguation of spatiotemporal variability, tracking of the evolution of solar wind structures, and determination of how the transport of energetic particles is impacted by these variabilities.

solar wind↗

The design of a five-cell superconducting RF module with a PBG coupler cell

We discuss the problem of incorporating a Photonic Band Gap (PBG) cell into a superconducting accelerating module of 5 cells designed for the operational frequency of 2.1 GHz. The reason for using a PBG cell is to provide a good accelerating mode confinement and good Higher Order Mode (HOM) suppression. PBG cell can potentially be used for placing HOM and fundamental mode couplers. However, because of the naturally higher ratio of the peak magnetic field to the accelerating field in the PBG cell, it should be designed to operate at a lower accelerating gradient than the other cells of the module. This ensures that the probability of quench in the PBG cell would be no higher than in other elliptical cells of the structure.

43 PARTICLE ACCELERATORS↗