Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Preliminary Low Temperature Electron Irradiation of Triple Junction Solar Cells

For many years extending solar power missions far from the sun has been a challenge not only due to the rapid falloff in solar intensity (intensity varies as inverse square of solar distance) but also because some of the solar cells in an array may exhibit a LILT (low intensity low temperature) degradation that reduces array performance. Recent LILT tests performed on commercial triple junction solar cells have shown that high performance can be obtained at solar distances as great as approx. 5 AU1. As a result, their use for missions going far from the sun has become very attractive. One additional question that remains is whether the radiation damage experienced by solar cells under low temperature conditions will be more severe than when measured during room temperature radiation tests where thermal annealing may take place. This is especially pertinent to missions such as the New Frontiers mission Juno, which will experience cell irradiation from the trapped electron environment at Jupiter. Recent testing2 has shown that low temperature proton irradiation (10 MeV) produces cell degradation results similar to room temperature irradiations and that thermal annealing does not play a factor. Although it is suggestive to propose the same would be observed for low temperature electron irradiations, this has not been verified. JPL has routinely performed radiation testing on commercial solar cells and has also performed LILT testing to characterize cell performance under far sun operating conditions. This research activity was intended to combine the features of both capabilities to investigate the possibility of any room temperature annealing that might influence the measured radiation damage. Although it was not possible to maintain the test cells at a constant low temperature between irradiation and electrical measurements, it was possible to obtain measurements with the cell temperature kept well below room temperature. A fluence of 1E15 1MeV electrons was selected as representative of a moderately high dose that might be expected for a solar powered mission. Fluences much greater than this would require large increases in array area and mass, compromising the ability of PV to compete with non-solar alternatives.

Stella, Paul M.↗

Raman shifts in electron-irradiated monolayer MoS 2

Here, we report how the presence of electron-beam-induced sulfur vacancies affects first-order Raman modes and correlate the effects with the evolution of the in situ transmission-electron microscopy (TEM) two-terminal conductivity of monolayer MoS 2 under electron irradiation. We observe a redshift in the E Raman peak and a less pronounced blueshift in the A' 1 peak with increasing electron dose. Using energy-dispersive X-ray spectroscopy (EDS), we show that irradiation causes partial removal of sulfur and correlate the dependence of the Raman peak shifts with S vacancy density (a few %), which is confirmed by first-principles density functional theory calculations. In situ device current measurements show exponential decrease in channel current upon irradiation. Our analysis demonstrates that the observed frequency shifts are intrinsic properties of the defective systems and that Raman spectroscopy can be used as a quantitative diagnostic tool to characterize MoS 2 -based transport channels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fundamental Studies of Irradiation-Induced Modifications in Microstructural Evolution and Mechanical Properties of Advanced Alloys

This final technical report summarizes the research performed during October 2014 and December 2017, with a focus on investigating the radiation-induced microstructural and mechanical property modifications in optimized advanced alloys for sodium-cooled fast reactor (SFR) structural applications. To accomplish these objectives, the radiation responses of several different advanced alloys, including austenitic steel Alloy 709 (A709) and 316H, and ferritic/ martensitic Fe–9Cr steels T91 and G92, were investigated using a combination of microstructure characterizations and nanoindentation measurements. Different types of irradiation, including ex situ bulk ion irradiation and in situ transmission electron microscopy (TEM) ion irradiation, were employed in this study. Radiation-induced dislocations, precipitates, and voids were characterized by TEM. Scanning transmission electron microscopy with energy dispersive X-ray spectroscopy (STEM-EDS) and/or atom probe tomography (APT) were used to study radiation-induced segregation and precipitation. Nanoindentation was used for hardness measurements to study irradiation hardening. Austenitic A709 and 316H was bulk-irradiated by 3.5 MeV Fe ++ ions to up to 150 peak dpa at 400, 500, and 600°. Compared to neutron-irradiated stainless steel (SS) 316, the Frank loop density of ion-irradiated A709 shows similar dose dependence at 400°, but very different temperature dependence. Due to the noticeable difference in the initial microstructure of A709 and 316H, no systematic comparison on the Frank loops in A709 vs 316H was made. It would be helpful that future ion irradiation study on 316 stainless steel could be conducted to directly compare the temperature dependence of Frank loop density in ion-irradiated 316 SS with that in neutron-irradiated 316 SS. In addition, future neutron irradiation on A709 at 400–600° at relative high dose (≥10 dpa) can be carried out to compare with ion-irradiated A709. The radiation-induced segregation (RIS) of Ni and Si was observed in both A709 and 316H in all irradiated conditions and was found at various sinks: line dislocations, dislocation loops, void surfaces, carbide-matrix interfaces, etc. Radiation also induced the formation of Ni,Si-rich precipitates. As suggested in a previous study on neutron-irradiated 316 stainless steel, one possible consequence of the significant RIS of Si is that the enrichment at defect sinks depletes the silicon in the matrix, which can lead to enhanced void nucleation rate. The enrichment of Ni and Si is accompanied by the depletion of Cr at defect sinks, which could also affect the corrosion resistance. Radiation-induced change in the orientation relationship of pre-existing MX precipitates was observed at 600°. It is believed that this change is associated with the network dislocations formed under irradiation. The underlying mechanism is still not well understood. This change could be a positive indication that the MX precipitates can survive high density network dislocations. It would be helpful if neutron irradiation at similar dose conditions could be carried out to verify that this effect is not unique for ion irradiation. Intragranular Cr-rich carbides with a core-shell structure, i.e. Cr-rich carbide core and Ni,Si-rich shell was found at 500° and 600° in the highest dose (150 peak dpa) specimens. Coarse voids (30 nm in diameter) were only commonly found at 500° in the 50 and 150 peak dpa specimens in regions less than 750 nm in depth. The highest swelling for A709 irradiated to 50 and 150 peak dpa at 500° is about 0.44% and 0.37%, respectively. Due to the choice of 100 degree temperature intervals, this study did not attempt to precisely identify peak void swelling conditions, merely the range of irradiation temperatures where this could be a concern. It is known high-dose ion irradiation can significantly suppress void nucleation. Future neutron irradiation in the 500–600° range (without considering the temperature shift) is needed to determine the onset of accelerated void swelling (possibly at lower dose).

36 MATERIALS SCIENCE↗

Deformation Behavior in Neutron Irradiated Generation II FeCrAl Alloys for Accident Tolerant Fuel Cladding

Preliminary work has been completed to evaluate the deformation behavior of the Generation II FeCrAl alloy class. The Generation II alloy, C35M, was neutron irradiated within the High Flux Isotop e Reactor followed by post-irradiation examination to evaluate the mechanical properties, irradiated microstructure, deformation modes, and deformation microstructure. Complementary characterization techniques were used in this evaluation. It was found tha t aft er irradiation to1.8 dpa at 364 °C that the C35M specimen failed in a ductile manner. The observed deformation microstructure showed a high density of line dislocations, dislocation networks, and dislocation pile-ups. The observed performance and stru cture s are consistent with literature studies on high-Cr FeCr alloys that were thermally aged at 500°C. The observed results suggest that Generation II FeCrAl alloys retain ductility under low-dose, prototypical LWR irradiation conditions.

36 MATERIALS SCIENCE↗

Characterization of Humoral Responses to Nipah Virus Infection in the Syrian Hamster Model of Disease

Abstract Nipah virus (NiV) is a highly pathogenic paramyxovirus. The Syrian hamster model recapitulates key features of human NiV disease and is a critical tool for evaluating antivirals and vaccines. Here we describe longitudinal humoral immune responses in NiV-infected Syrian hamsters. Samples were obtained 1–28 days after infection and analyzed by ELISA, neutralization, and Fc-mediated effector function assays. NiV infection elicited robust antibody responses against the nucleoprotein and attachment glycoprotein. Levels of neutralizing antibodies were modest and only detectable in surviving animals. Fc-mediated effector functions were mostly observed in nucleoprotein-targeting antibodies. Antibody levels and activities positively correlated with challenge dose.

Immunology↗

CG13250, a novel bromodomain inhibitor, suppresses proliferation of multiple myeloma cells in an orthotopic mouse model

Multiple myeloma (MM) is characterized by the clonal proliferation of neoplastic plasma cells. Despite a stream of new molecular targets based on better understanding of the disease, MM remains incurable. Epigenomic abnormalities contribute to the pathogenesis of MM. bromodomain 4 (BRD4), a member of the bromodomain and extraterminal (BET) family, binds to acetylated histones during M/G1 transition in the cell cycle promoting progression to S phase. In this study, we investigated the effects of a novel BET inhibitor CG13250 on MM cells. CG13250 inhibited ligand binding to BRD4 in a dose-dependent manner and with an IC{sub 50} value of 1.1 μM. It inhibited MM proliferation in a dose-dependent manner and arrested cells in G1, resulting in the induction of apoptosis through caspase activation. CG13250 inhibited the binding of BRD4 to c-MYC promoter regions suppressing the transcription of the c-MYC gene. Administered in vivo, CG13250 significantly prolonged survival of an orthotopic MM-bearing mice. In conclusion, CG13250 is a novel bromodomain inhibitor that is a promising molecular targeting agent against MM. - Highlights: • A novel bromodomain inhibitor CG13250 suppresses MM cell proliferation. • CG13250 decreases C-MYC expression, resulting in the induction of apoptosis. • CG13250 prolongs the survivals of MM-bearing mice.

60 APPLIED LIFE SCIENCES↗

Contamination Observed on the Passive Optical Sample Assembly (POSA)-1 Experiment

The Passive Optical Sample Assembly-1 (POSA-1), part of the Mir Environmental Effects Payload (MEEP), was designed to study the combined effects of contamination, atomic oxygen, ultraviolet radiation, vacuum, thermal cycling, and other constituents of the space environment on spacecraft materials. The MEEP program is a Phase 1 International Space Station Risk Mitigation Experiment. The payload was attached by EVA to the exterior of the Mir docking module during the Space Shuttle mission STS-76. It was removed during STS-86 after exposure to the Mir environment for 18 months. POSA-1 consists of nearly 400 samples of thermal control paints, chemical conversion coatings, mirrors, optics, and other candidate materials for International Space Station Alpha (ISSA). POSA-1 also flew state-of-the-art materials, such as electrically conductive thermal control coatings developed under contract by IITRI and AZ Technology, and passive instruments for monitoring the atomic oxygen and ultraviolet radiation dose to the experiment. Contamination was detected on the POSA-1 experiment. On the side facing space (-Z(sub B) direction using the Mir coordinate system), visible contamination was observed. The contamination was uniform as would occur from a slow photodeposition process. A very definite film was deposited on the optical samples. The deposition appears to have directionality with definite shadowing effects. On the side facing the main Mr core (+ZB direction using the Mir coordinate system), no visible contamination was noted. Pre- and post-flight characterization of candidate spacecraft materials is discussed, particularly the effect of contamination on total hemispherical spectral reflectance (250 - 2500 nm), infrared emittance, the bi-directional reflectance distribution function (BRDF), and vacuum ultraviolet spectral reflectance. Extensive photography under normal and black light was performed. Results of electron spectroscopy for chemical analysis (ESCA) and Fourier Transform Infrared Analysis (FTIR) on selected samples are also discussed.

Zwiener, James M.↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-118: Characterization of Change in Fractional Anisotropy After Radiation Therapy: Does Nearby Disruption Predict for White Matter Damage?

Purpose: We investigated predictors of fractional anisotropy (FA) change in the corticospinal white matter tract (CST) following radiation therapy (RT). Methods: Diffusion tensor imaging (DTI) is a non-invasive modality which models water diffusion properties. FA quantifies the extent of directional bias—a decrease indicates disrupted white matter integrity. Fifteen patients with high-grade glioma underwent DTI scans before, and ten months after RT to 59.4–60 Gy. The CST was segmented using an automated atlas-based algorithm on all DTI images. Treatment planning CT and DTI images were aligned using non-linear registration allowing for baseline FA, follow-up FA, and absorbed dose to be determined in each voxel. Relative FA change was dichotomized into a binary outcome using 25% decrease as cutoff. Three metrics were assessed as predictors: voxel dose, distance from the voxel to the center of the CST (Rc), and the number of neighboring voxels (Nadj from 0 to 26) with ≥25% decrease in FA. Logistic regression and the area under the receiver-operating characteristics curve (AUC) analysis were performed for each patient. Results: Median age of the cohort was 59 years (range: 40–85). The average number of voxels in the CST amongst all patients was 1181 (±172, SD). In logistic regression, the probability of FA change was highly associated with Nadj in all 15 patients with corresponding AUCs between 0.81 and 0.97. With all three metrics included in the logistic regression models, Nadj was highly significant (p<0.001) in all patients, voxel dose significant (p<0.05) in 3/15 patients, and Rc significant in 12/15 patients (p<0.05). Conclusion: The number of neighboring voxels with change in FA was the dominant predictor of FA change at any given voxel. This suggests that the microenvironment of surrounding white matter disruption after radiation therapy may drive local effects along a white matter tract. Pettersson and Cervino are funded by a Varian Medical Systems grant.

60 APPLIED LIFE SCIENCES↗

Hydroxyl radical mediated damage of proteins in low oxygen solution investigated using X-ray footprinting mass spectrometry

In the method of X-ray footprinting mass spectrometry (XFMS), proteins at micromolar concentration in solution are irradiated with a broadband X-ray source, and the resulting hydroxyl radical modifications are characterized using liquid chromatography mass spectrometry to determine sites of solvent accessibility. These data are used to infer structural changes in proteins upon interaction with other proteins, folding, or ligand binding. XFMS is typically performed under aerobic conditions; dissolved molecular oxygen in solution is necessary in many, if not all, the hydroxyl radical modifications that are generally reported. In this study we investigated the result of X-ray induced modifications to three different proteins under aerobic versus low oxygen conditions, and correlated the extent of damage with dose calculations. We observed a concentration-dependent protecting effect at higher protein concentration for a given X-ray dose. For the typical doses used in XFMS experiments there was minimal X-ray induced aggregation and fragmentation, but for higher doses we observed formation of covalent higher molecular weight oligomers, as well as fragmentation, which was affected by the amount of dissolved oxygen in solution. The higher molecular weight products in the form of dimers, trimers, and tetramers were present in all sample preparations, and, upon X-ray irradiation, these oligomers became non-reducible as seen in SDS-PAGE. The results provide an important contribution to the large body of X-ray radiation damage literature in structural biology research, and will specifically help inform the future planning of XFMS, and well as X-ray crystallography and small-angle X-ray scattering experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plasma Immersion Ion Implantation for Interdigitated Back Passivated Contact (IBPC) Solar Cells

We present progress to develop low-cost interdigitated back contact solar cells with pc-Si/SiO2/c-Si passivated contacts formed by plasma immersion ion implantation (PIII). PIII is a lower-cost implantation technique than traditional beam-line implantation due to its simpler design, lower operating costs, and ability to run high doses (1E14-1E18 cm-2) at low ion energies (20 eV-10 keV). These benefits make PIII ideal for high throughput production of patterned passivated contacts, where high-dose, low-energy implantations are made into thin (20-200 nm) a-Si layers instead of into the wafer itself. For this work symmetric passivated contact test structures grown on n-Cz wafers with PH3 PIII doping gave implied open circuit voltage (iVoc) values of 730 mV with Jo values of 2 fA/cm2. Samples doped with B2H6 gave iVoc values of 690 mV and Jo values of 24 fA/cm2, outperforming BF3 doping, which gave iVoc values in the 660-680 mV range. Samples were further characterized by photoluminescence and SIMS depth profiles. Initial IBPC cell results are presented.

14 SOLAR ENERGY↗

Poster - 24: Characterization of the energy dependence of high-sensitivity MCP-N TLD and Al2O3:C OSLD in-vivo dosimetry systems for 40–100 kVp energies

Purpose: To characterize the energy dependence of high-sensitivity MCP-N TLD and Al{sub 2}O{sub 3}:C OSLD dosimetry systems at low (40–100 kVp) energies for in-vivo dosimetry. Methods: We assessed the variation of response with energy of two detectors in the 40–100 kVp energy range: high-sensitivity MCP-N TLDs (LiF:Mg,Cu,P) and OSLDs (Al{sub 2}O{sub 3}:C). The detectors were irradiated with an XRad 320ix biological irradiator under reference conditions. The delivered dose was 10 cGy for 7 beam qualities ranging from 40–100 kVp, 1.7–4.0 mm Al, and effective energies 26.9–37.9 keV. Both sets of detectors were also irradiated under reference conditions at 6 MV using a Varian Clinac 21Ex to assess the change in response from high-energy beams. Results: The MCP-N high-sensitivity TLDs were relatively insensitive to energies in the kV range, as their response varied by ±5%, i.e. well within the reproducibility limits of these detectors. However, the OSLDs exhibited a linearly-decreasing response with energy with a response 18.7% higher at 40 kVp than at 100 kVp for the same nominal dose. Compared to the 6 MV beams used in conventional radiotherapy, OSLDs responded 3.3–3.9 times higher depending on beam quality while the MCP-N TLD response was unchanged within experimental uncertainty. Conclusions: Unlike the more commonly used TLD-100, the high-sensitivity MCP-N TLDs exhibit little to no energy response. OSLDs are shown to be highly energy-dependent, both from MV to kV and within the kV range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

Health effects following subacute exposure to geogenic dusts from arsenic-rich sediment at the Nellis Dunes Recreation Area, Las Vegas, NV

Geogenic dust from arid environments is a possible inhalation hazard for humans, especially when using off-road vehicles that generate significant dust. This study focused on immunotoxicological and neurotoxicological effects following subacute exposure to geogenic dust generated from sediments in the Nellis Dunes Recreation Area near Las Vegas, Nevada that are particularly high in arsenic; the naturally-occurring arsenic concentrations in these surficial sediments ranged from 4.8 to 346 μg/g. Dust samples from sediments used in this study had a median diameter of 4.5 μm and also were a complex mixture of naturally-occurring metals, including aluminum, vanadium, chromium, manganese, iron, cobalt, copper, zinc, strontium, cesium, lead, uranium, and arsenic. Adult female B6C3F1 mice exposed via oropharyngeal aspiration to 0.01 to 100 mg dust/kg body weight, four times, a week apart, for 28 days, were evaluated 24 h after the last exposure. Peripheral eosinophils were increased at all concentrations, serum creatinine was dose responsively increased beginning at 1.0 mg/kg/day, and blood urea nitrogen was decreased at 10 and 100 mg/kg/day. Antigen-specific IgM responses and natural killer cell activity were dose-responsively suppressed at 0.1 mg/kg/day and above. Splenic CD4 + CD25 + T cells were decreased at 0.01, 0.1, 10, and 100 mg/kg/day. Antibodies against MBP, NF-68, and GFAP were selectively reduced. A no observed adverse effect level of 0.01 mg/kg/day and a lowest observed adverse effect level of 0.1 mg/kg/day were determined from IgM responses and natural killer cell activity, indicating that exposure to this dust, under conditions similar to our design, could affect these responses. - Highlights: • Toxicity of geogenic dust from arsenic-rich sediment in Nevada was characterized. • The geogenic dust is a mixture of many metals and crystalline silica. • Geogenic dust exposure decreased IgM antibodies and natural killer cell activity.

60 APPLIED LIFE SCIENCES↗

Estimation of iodine nutrition and thyroid function status in late-gestation pregnant women in the United States: Development and application of a population-based pregnancy model

Previously, a deterministic biologically-based dose-response (BBDR) pregnancy model was developed to evaluate moderate thyroid axis disturbances with and without thyroid-active chemical exposure in a near-term pregnant woman and fetus. In the current study, the existing BBDR model was adapted to include a wider functional range of iodine nutrition, including more severe iodine deficiency conditions, and to incorporate empirically the effects of homeostatic mechanisms. The extended model was further developed into a population-based model and was constructed using a Monte Carlo-based probabilistic framework. In order to characterize total (T4) and free (fT4) thyroxine levels for a given iodine status at the population-level, the distribution of iodine intake for late-gestation pregnant women in the U.S was reconstructed using various reverse dosimetry methods and available biomonitoring data. The range of median (mean) iodine intake values resulting from three different methods of reverse dosimetry tested was 196.5–219.9 μg of iodine/day (228.2–392.9 μg of iodine/day). There was minimal variation in model-predicted maternal serum T4 and ft4 thyroxine levels from use of the three reconstructed distributions of iodine intake; the range of geometric mean for T4 and fT4, was 138–151.7 nmol/L and 7.9–8.7 pmol/L, respectively. The average value of the ratio of the 97.5th percentile to the 2.5th percentile equaled 3.1 and agreed well with similar estimates from recent observations in third-trimester pregnant women in the U.S. In addition, the reconstructed distributions of iodine intake allowed us to estimate nutrient inadequacy for late-gestation pregnant women in the U.S. via the probability approach. The prevalence of iodine inadequacy for third-trimester pregnant women in the U.S. was estimated to be between 21% and 44%. Taken together, the current work provides an improved tool for evaluating iodine nutritional status and the corresponding thyroid function status in pregnant women in the U.S. This model enables future assessments of the relevant risk of thyroid hormone level perturbations due to exposure to thyroid-active chemicals at the population-level. - Highlights: • A population-based thyroid function model for pregnant women was developed. • The model was used specifically study the late-gestation pregnant women in the U.S. • The prevalence of iodine inadequacy was estimated in the sub-population studied. • Developed model well predicts trimester-specific thyroid hormone reference ranges. • The model can be further used to study thyroid perturbations at a population level.

60 APPLIED LIFE SCIENCES↗

Retrospective Imaging and Characterization of Nuclear Material

Modern techniques for detection of covert nuclear ma-terial requires some combination of real time measurement and/or sampling of the material. More common is real time measure-ment of the ionizing emission caused by radioactive decay or through the materials measured in response to external interroga-tion radiation. One can expose the suspect material with various radiation types, including high energy photons such as x rays or with larger particles such as neutrons and muons, to obtain images or measure nuclear reactions induced in the material. Stand-off detection using imaging modalities similar to those in the medical field can be accomplished, or simple collimated detec-tors can be used to localize radioactive materials. In all such cases, the common feature is that some or all of the nuclear materials have to be present for the measurement, which makes sense; as one might ask, “How you can measure something that is not there?” The current work and results show how to do exactly that: characterize nuclear materials after they have been removed from an area leaving no chemical trace. This new approach is demon-strated to be fully capable of providing both previous source spa-tial distribution and emission energy grouping. The technique uses magnetic resonance for organic insulators and/or lumines-cence techniques on ubiquitous refractory materials similar in theory to the way the nuclear industry carries out worker person-nel dosimetry. Spatial information is obtained by acquiring gridded samples for dosimetric measurements, while energy infor-mation comes through dose depth profile results that are func-tions of the incident radiation energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗