Identification and Quantification of Carbon Phases in Conversion Fuel for the Transient Reactor Test Facility

As part of an overall effort to convert US research reactors to low-enriched uranium (LEU) fuel, a LEU conversion fuel is being designed for the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory. TREAT fuel compacts are comprised of UO{sub 2} fuel particles in a graphitic matrix material. In order to refine heat transfer modeling, as well as determine other physical and nuclear characteristics of the fuel, the amount and type of graphite and non-graphite phases within the fuel matrix must be known. In this study, we performed a series of complementary analyses, designed to allow detailed characterization of the graphite and phenolic resin based fuel matrix. Methods included Scanning Electron Microscopy, Raman spectroscopy, and X-ray Diffraction. Our results indicate that no single characterization technique will yield all of the desired information; however, through the use of statistical and empirical data analysis, such as curve fitting, partial least squares regression, volume extrapolation and spectra peak ratios, a degree of certainty for the quantity of each phase can potentially be obtained. Although no one type of analysis has provided a complete determination of the quantities and identities of all carbon phases present in the fuel matrix, additional information has been gathered and is being used to refine future analysis methods. From the three types of quantification performed, results have been within 1% (92.8%, 93.02% and 93.6% for BSE image analysis, XRD and Raman spectroscopy, respectively). More work remains to identify any trace crystalline carbonaceous phases that may be present, quantify any traces that are identified, and develop and use further complementary bulk phase quantification techniques. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast GPU 3D diffeomorphic image registration

3D image registration is one of the most fundamental and computationally expensive operations in medical image analysis. Here, we present a mixed-precision, Gauss–Newton–Krylov solver for diffeomorphic registration of two images. Our work extends the publicly available CLAIRE library to GPU architectures. Despite the importance of image registration, only a few implementations of large deformation diffeomorphic registration packages support GPUs. Our contributions are new algorithms to significantly reduce the run time of the two main computational kernels in CLAIRE: calculation of derivatives and scattered-data interpolation. Additionally, we deploy (i) highly-optimized, mixed-precision GPU-kernels for the evaluation of scattered-data interpolation, (ii) replace Fast-Fourier-Transform (FFT)-based first-order derivatives with optimized 8th-order finite differences, and (iii) compare with state-of-the-art CPU and GPU implementations. As a highlight, we demonstrate that we can register clinical images in less than 6 s on a single NVIDIA Tesla V100. This amounts to over 20 speed-up over the current version of CLAIRE and over 30 speed-up over existing GPU implementations.

97 MATHEMATICS AND COMPUTING↗

Using x-ray microtomography and pore-scale modeling to quantify sediment mixing and fluid flow in a developing streambed

X-ray micro-tomography (XMT), image processing, and lattice Boltzmann (LB) methods were combined to observe sediment mixing, subsurface structure, and patterns of hydrogeological properties associated with bed sediment transport. Transport and mixing of sand and spherical glass beads were observed in a laboratory flume, beginning from a well-defined layered initial condition. Cores were obtained from the streambed at four different times, and each core was scanned by XMT in order to assess the evolution of spatial patterns within the bed. Image analysis clearly revealed the propagation of a sediment mixing front that began at the bed surface. The image data were used as boundary conditions in 3D LB simulation of pore fluid flow, showing that sediment sorting produced strong vertical gradients in permeability near the streambed surface. This new methodological approach offers potential for greatly improved characterization of mixing and transport of fine sediments in a wide variety of aquatic systems.

58 GEOSCIENCES↗

Display management subsystem, version 1: A user's eye view

The structure and application functions of the Display Management Subsystem (DMS) are described. The DMS, a subsystem of the Transportable Applications Executive (TAE), was designed to provide a device-independent interface for an image processing and display environment. The system is callable by C and FORTRAN applications, portable to accommodate different image analysis terminals, and easily expandable to meet local needs. Generic applications are also available for performing many image processing tasks.

Parker, Dolores↗

General-purpose interface bus for multiuser, multitasking computer system

The architecture of a multiuser, multitasking, virtual-memory computer system intended for the use by a medium-size research group is described. There are three central processing units (CPU) in the configuration, each with 16 MB memory, and two 474 MB hard disks attached. CPU 1 is designed for data analysis and contains an array processor for fast-Fourier transformations. In addition, CPU 1 shares display images viewed with the image processor. CPU 2 is designed for image analysis and display. CPU 3 is designed for data acquisition and contains 8 GPIB channels and an analog-to-digital conversion input/output interface with 16 channels. Up to 9 users can access the third CPU simultaneously for data acquisition. Focus is placed on the optimization of hardware interfaces and software, facilitating instrument control, data acquisition, and processing.

Generazio, Edward R.↗

The interpretation of simultaneous soft X-ray spectroscopic and imaging observations of an active region

Simultaneous soft X-ray spectroscopic and broad-band imaging observations of an active region have been analyzed together to determine the parameters which describe the coronal plasma. From the spectroscopic data, models of temperature-emission measure-elemental abundance have been constructed which provide acceptable statistical fits. By folding these possible models through the imaging analysis, models which are not self-consistent can be rejected. In this way, only the oxygen, neon, and iron abundances of Pottasch (1967), combined with either an isothermal or exponential temperature-emission-measure model, are consistent with both sets of data. Contour maps of electron temperature and density for the active region have been constructed from the imaging data. The implications of the analysis for the determination of coronal abundances and for future satellite experiments are discussed.

Davis, J. M.↗

SU-F-T-119: Development of Heart Prediction Model to Increase Accuracy of Dose Reconstruction for Radiotherapy Patients

Purpose: To assess individual variation in heart volume and location in order to develop a prediction model of the heart. This heart prediction model will be used to calculate individualized heart doses for radiotherapy patients in epidemiological studies. Methods: Chest CT images for 30 adult male and 30 adult female patients were obtained from NIH Clinical Center. Image-analysis computer programs were used to segment the whole heart and 8 sub-regions and to measure the volume of each sub- region and the dimension of the whole heart. An analytical dosimetry method was used for the 30 adult female patients to estimate mean heart dose during conventional left breast radiotherapy. Results: The average volumes of the whole heart were 803.37 cm{sup 3} (COV 18.8%) and 570.19 cm{sup 3} (COV 18.8%) for adult male and female patients, respectively, which are comparable with the international reference volumes of 807.69 cm{sup 3} for males and 596.15 cm{sup 3} for females. Some patient characteristics were strongly correlated (R{sup 2}>0.5) with heart volume and heart dimensions (e.g., Body Mass Index vs. heart depth in males: R{sup 2}=0.54; weight vs. heart width in the adult females: R{sup 2}=0.63). We found that the mean heart dose 3.805 Gy (assuming prescribed dose of 50 Gy) in the breast radiotherapy simulations of the 30 adult females could be an underestimate (up to 1.6-fold) or overestimate (up to 1.8-fold) of the patient-specific heart dose. Conclusion: The study showed the significant variation in patient heart volumes and dimensions, resulting in substantial dose errors when a single average heart model is used for retrospective dose reconstruction. We are completing a multivariate analysis to develop a prediction model of the heart. This model will increase accuracy in dose reconstruction for radiotherapy patients and allow us to individualize heart dose calculations for patients whose CT images are not available.

60 APPLIED LIFE SCIENCES↗

Tracking Nanoparticle Diffusion and Interaction during Self-Assembly in a Liquid Cell

Nanoparticle self-assembly has been well studied theoretically, but it remains challenging to directly observe and quantify individual nanoparticle interactions. With our custom image analysis method, we track the trajectories of nanoparticle movement with high precision from a stack of relatively noisy images obtained using liquid cell transmission electron microscopy. In a time frame of minutes, Pt-Fe nanoparticles self-assembled into a loosely packed hcp lattice. The energetics and stability of the dynamic assembly were studied quantitatively. From velocity and diffusion measurements, we experimentally determined the magnitude of forces between single particles and the related physical properties. The results illustrate that long-range anisotropic forces drive the formation of chains, which then clump and fold to maximize close range van der Waals interactions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Image 100 procedures manual development: Applications system library definition and Image 100 software definition

An outline for an Image 100 procedures manual for Earth Resources Program image analysis was developed which sets forth guidelines that provide a basis for the preparation and updating of an Image 100 Procedures Manual. The scope of the outline was limited to definition of general features of a procedures manual together with special features of an interactive system. Computer programs were identified which should be implemented as part of an applications oriented library for the system.

Guseman, L. F., Jr.↗

The LANDSAT Tutorial Workbook: Basics of Satellite Remote Sensing

Most of the subject matter of a full training course in applying remote sensing is presented in a self-teaching mode in this how-to manual which combines a review of basics, a survey of systems, and a treatment of the principles and mechanics of image analysis by computers, with a laboratory approach for learning to utilize the data through practical experiences. All relevant image products are included.

Short, Nicholas M.↗

Sensor fusion II: Human and machine strategies; Proceedings of the Meeting, Philadelphia, PA, Nov. 6-9, 1989

Various papers on human and machine strategies in sensor fusion are presented. The general topics addressed include: active vision, measurement and analysis of visual motion, decision models for sensor fusion, implementation of sensor fusion algorithms, applying sensor fusion to image analysis, perceptual modules and their fusion, perceptual organization and object recognition, planning and the integration of high-level knowledge with perception, using prior knowledge and context in sensor fusion.

Schenker, Paul S.↗

WELDSMART: A vision-based expert system for quality control

This work was aimed at exploring means for utilizing computer technology in quality inspection and evaluation. Inspection of metallic welds was selected as the main application for this development and primary emphasis was placed on visual inspection, as opposed to other inspection methods, such as radiographic techniques. Emphasis was placed on methodologies with the potential for use in real-time quality control systems. Because quality evaluation is somewhat subjective, despite various efforts to classify discontinuities and standardize inspection methods, the task of using a computer for both inspection and evaluation was not trivial. The work started out with a review of the various inspection techniques that are used for quality control in welding. Among other observations from this review was the finding that most weld defects result in abnormalities that may be seen by visual inspection. This supports the approach of emphasizing visual inspection for this work. Quality control consists of two phases: (1) identification of weld discontinuities (some of which may be severe enough to be classified as defects), and (2) assessment or evaluation of the weld based on the observed discontinuities. Usually the latter phase results in a pass/fail judgement for the inspected piece. It is the conclusion of this work that the first of the above tasks, identification of discontinuities, is the most challenging one. It calls for sophisticated image processing and image analysis techniques, and frequently ad hoc methods have to be developed to identify specific features in the weld image. The difficulty of this task is generally not due to limited computing power. In most cases it was found that a modest personal computer or workstation could carry out most computations in a reasonably short time period. Rather, the algorithms and methods necessary for identifying weld discontinuities were in some cases limited. The fact that specific techniques were finally developed and successfully demosntrated to work illustrates that the general approach taken here appears to be promising for commercial development of computerized quality inspection systems. Inspection based on these techniques may be used to supplement or substitute more elaborate inspection methods, such as x-ray inspections.

Andersen, Kristinn↗

Exploring Object Detection and Image Classification Tasks for Niche Use Case in Naturalistic Driving Studies

Naturalistic driving studies consist of drivers using their personal vehicles and provide valuable real-world data, but privacy issues must be handled very carefully. Drivers sign a consent form when they elect to participate, but passengers do not for a variety of practical reasons. However, their privacy must still be protected. One large study includes a blurred image of the entire cabin which allows reviewers to find passengers in the vehicle; this protects the privacy but still allows a means of answering questions regarding the impact of passengers on driver behavior. A method for automatically counting the passengers would have scientific value for transportation researchers. We investigated different image analysis methods for automatically locating and counting the non-drivers including simple face detection and fine-tuned methods for image classification and a published object detection method. We also compared the image classification using convolutional neural network and vision transformer backbones. Our studies show the image classification method appears to work the best in terms of absolute performance, although we note the closed nature of our dataset and nature of the imagery makes the application somewhat niche and object detection methods also have advantages. We perform some analysis to support our conclusion.

Peruski, Ryan↗

Point spread function deconvolution using a convolutional autoencoder

A major issue in optical astronomical image analysis is the combined effect of the instrument’s point spread function (PSF) and the atmospheric seeing that blurs images and changes their shape in a way that is band and time-of-observation dependent. In this work we present a very simple neural network based approach to nonblind image deconvolution that relies on feeding a convolutional autoencoder (CAE) input images that have been preprocessed by convolution with the corresponding PSF and its regularized inverse, a method which is both conceptually simple and computationally less intensive. We also present here, a new approach for dealing with limited input dynamic range of neural networks compared to the dynamic range present in astronomical images.

79 ASTRONOMY AND ASTROPHYSICS↗

Taylor Gun Impact Tests on Mock Comp-B Specimens

Twelve (12) Mock Comp-B specimens were received from Sandia National Laboratories in Albuquerque. Specimens were approximately 76.3 mm long and 15.8 mm in diameter. Weights varied from 21.23 to 22.14 grams, and various pieces had visible, mm-sized holes or gaps due to fabrication. Hand-marked lines, 1-centimeter down the length, were used in image analysis. Specimens were fired out of the Taylor gas gun and impacted on a brass anvil. High-speed images (25 μs per frame) were taken of the specimen during impact, with the camera 1) viewing through a boom box side port or 2) viewing from the top/front of the anvil through a Lexan window on the boom box. Side views are useful because they show silhouette contours of the specimen collapse. Top view images are useful because they show more clearly the time and strain at which fracture and fragmentation begins. We tested 4 specimen velocities: 133.5, 115.3, 87.8 and 74.5 m/s. At each velocity, at least one specimen was viewed from the side and one viewed from the top.

36 MATERIALS SCIENCE↗

Biases associated with a particular image volume metric

Image analysis area and volume metrics A 80 and V 80 , used by others, are studied as a function of image morphology, a 3D feature, and Monte Carlo noise in simulated images. The A 80 area metric is found to be stable, with consistent results (and meaning) obtainable without a detailed understanding of 3D features and/or simulation noise levels. However, the V 80 volume metric varies significantly with image morphology, 3D features, and simulation noise. If an experimental image set gives A 80 area inferences that are consistent with 2D image simulations, but V 80 volume inferences that are significantly larger than those corresponding to simulated images, then issues related to 3D features and simulation noise should be explored before conclusions are drawn related to a possible mismatch in the real physical size of experimental and simulated source volumes.

47 OTHER INSTRUMENTATION↗

An efficient microcomputer system for the analysis of particle image velocimetry specklegrams

An efficient image processing system is described for the automatic analysis of particle image velocimetry (PIV) fringe patterns. Each interrogation point takes 1 second to analyze; a complete specklegram can be interrogated at 1000 points in approximately 15 minutes. Incorporated in the analysis is a means for automatic replacement of spurious velocity vectors without either re-interrogation of the specklegram or interpolation between neighboring data points. The sucess of the above system is demonstrated by application of the PIV technique to the study of the sink-driven cavity flow. This flow is studied as part of a larger program to investigate trapped vortex flows as a means of lift enhancement on swept wings.

Wadcock, Alan J.↗

Radiation-induced alteration of sandstone concrete aggregate

This study investigates the alteration of felsic sandstone-type rock, which is used as a coarse aggregate in concrete, subject to the effects of gamma-ray and neutron irradiation. The effects of three gamma-ray doses (27, 55, and 108 MGy) and four neutron fluence levels (1.22, 2.19, 6.99, and 14.30 × 10 19 n/cm 2 , $E$ ≥ 0.01 MeV) were investigated. Quartz and albite were found to be the major rock-forming minerals, with microcline intermediates, chlorite, and muscovite as the minors. Gamma rays caused no significant changes to the physical properties of the sandstone aggregates, even at high doses (108 MGy). In contrast, neutron irradiation caused alterations that became more pronounced at higher neutron fluences. The solid was confirmed to expand through metamictization of the rock-forming minerals. Quartz and muscovite were the most affected phases, whereas albite and microcline intermediates were only slightly affected, and chlorite was almost unaffected. The decrease in density was measured by He and water pycnometry, and this value was almost reproduced by calculations using the rock-forming mineral composition of the pristine sample measured using X-ray powder diffraction/Rietveld analysis and the cell volume change of the major forming minerals. In addition, light optical microscopy and scanning electron microscopy images confirmed the presence of intergranular and intragranular cracks. Intergranular cracks appeared to have initiated from the quartz grains, which expanded significantly. The intragranular cracks were frequently observed in the albite and microcline intermediates. These cracks can be described as radial cracks starting from the expanding quartz, caused by enforced displacement for deformation consistency with quartz expansion. The crack area ratio quantified by SEM image analysis corresponds to the discrepancy of the volume expansion difference calculated by He or water pycnometry and dimensional change measurements. In conclusion, an evaluation of solid expansion and crack openings in aggregates is important to estimate concrete degradation.