Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Beam Damage of HS (CH2)15 COOH Terminated Self Assembled Monolayer (SAM) as Observed by X-Ray Photoelectron Spectroscopy

XPS spectra of HS(CH{sub 2}){sub 15} COOH terminated a self assembled monolayer (SAM)sample was collected over a period of 242 minutes to determine specimen damage during long exposures to monochromatic Al Ka x-rays. For this COOH terminated SAM we measured the loss of oxygen as a function of time by rastering a focused 100 W, 100 um diameter x-ray beam over a 1.4 mm x 0.2 mm area of the sample.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Generation and manipulation of proton beams by ultra-short laser pulses

Applying a 21-channel Thomson spectrometer setup has revealed further insight to the connection between spatial and spectral beam characteristic of laser accelerated protons. Analyzing the central emission cone (plus/minus 3 degree) shows an increasing beam divergency for protons with increasing kinetic energies. This holds for protons emitted from the same source area at the target surface. The whole beam is a well ordered system with a clear functional dependence of trajectories on proton energy. This is a consequence of the source dynamics which is determined by the sheath development in time. Thus laser-driven ion beams can be advantageously manipulated for further propagation to an experiment. We demonstrate this capability with a magnetic quadrupole and obtain a nearly parallel and monochromatized beam. Furthermore we set our achievements in beam production efficiency into context with other laser systems and demonstrate the potential of very-thin target foils.

43 PARTICLE ACCELERATORS↗

Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations

Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S values for monoenergetic sources (electrons and photons) and different radionuclides ({sup 90}Y, {sup 131}I, and {sup 188}Re) were calculated. Simulations were performed in soft tissue. Three general-purpose MC codes were employed for simulating radiation transport: MCNP4C, EGSnrc, and GEANT4. The data published by the MIRD Committee in Pamphlet No. 17, obtained with the EGS4 MC code, were also included in the comparisons. The impact of the differences (in terms of voxel S values) among the MC codes was also studied by convolution calculations of the absorbed dose in a volume of interest. For uniform activity distribution of a given radionuclide, dose calculations were performed on spherical and elliptical volumes, varying the mass from 1 to 500 g. For simulations with monochromatic sources, differences for self-irradiation voxel S values were mostly confined within 10% for both photons and electrons, but with electron energy less than 500 keV, the voxel S values referred to the first neighbor voxels showed large differences (up to 130%, with respect to EGSnrc) among the updated MC codes. For radionuclide simulations, noticeable differences arose in voxel S values, especially in the bremsstrahlung tails, or when a high contribution from electrons with energy of less than 500 keV is involved. In particular, for {sup 90}Y the updated codes showed a remarkable divergence in the bremsstrahlung region (up to about 90% in terms of voxel S values) with respect to the EGS4 code. Further, variations were observed up to about 30%, for small source-target voxel distances, when low-energy electrons cover an important part of the emission spectrum of the radionuclide (in our case, for {sup 131}I). For {sup 90}Y and {sup 188}Re, the differences among the various codes have a negligible impact (within few percents) on convolution calculations of the absorbed dose; thus either one of the MC programs is suitable to produce voxel S values for radionuclide targeted therapy dosimetry. However, if a low-energy beta-emitting radionuclide is considered, these differences can affect also dose depositions at small source-target voxel distances, leading to more conspicuous variations (about 9% for {sup 131}I) when calculating the absorbed dose in the volume of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Excited state absorption of pump radiation as a loss mechanism in solid-state lasers

The characteristics of optical pumping dynamics in laser-pumped, rare-earth-doped, solid-state laser materials are investigated by using a tunable alexandrite laser to pump Y3Al5O12:Nd(3+) in an optical cavity. It is found that the slope efficiency of the Nd laser operation depends strongly on the wavelength of the pump laser. For pump wavelengths resulting in low slope efficiencies, intense fluorescence emission is observed from the sample in the blue-green spectral region. This is attributed to the excited-state absorption of pump photons which occurs during radiationless relaxation from the pump band to the metastable state. This type of process is an important loss mechanism for monochromatic pumping of laser systems at specific pump wavelengths.

Kliewer, Michael L.↗

Compact FEL-driven inverse compton scattering gamma-ray source

Many research and applications areas require photon sources capable of producing gamma-ray beams in the multi-MeV energy range with reasonably high fluxes and compact footprints. Besides industrial, nuclear physics and security applications, a considerable interest comes from the possibility to assess the state of conservation of cultural assets like statues, columns etc., via visualization and analysis techniques using high energy photon beams. Computed Tomography scans, widely adopted in medicine at lower photon energies, presently provide high quality three-dimensional imaging in industry and museums. We explore the feasibility of a compact source of quasi-monochromatic, multi-MeV gamma-rays based on Inverse Compton Scattering (ICS) from a high intensity ultra-violet (UV) beam generated in a free-electron laser by the electron beam itself. This scheme introduces a stronger relationship between the energy of the scattered photons and that of the electron beam, resulting in a device much more compact than a classic ICS for a given scattered energy. As a result, the same electron beam is used to produce gamma-rays in the 10–20 MeV range and UV radiation in the 10–15 eV range, in a ~4 × 22 m 2 footprint system.

43 PARTICLE ACCELERATORS↗

LANDSAT-D investigations in snow hydrology

The atmospheric radiative transfer calculation program (ATARD) and its supporting programs (setting up atmospheric profile, making Mie tables and an exponential-sum-fitting table) were completed. More sophisticated treatment of aerosol scattering (including angular phase function or asymmetric factor) and multichannel analysis of results from ATRAD are being developed. Some progress was made on a Monte Carlo program for examining two dimensional effects, specifically a surface boundary condition that varies across a scene. The MONTE program combines ATRAD and the Monte Carlo method together to produce an atmospheric point spread function. Currently the procedure passes monochromatic tests and the results are reasonable.

Dozier, J.↗

Near future MeV telescopes can discover asteroid-mass primordial black hole dark matter

Primordial black holes (PBHs), formed out of large over densities in the early Universe, are a viable dark matter (DM) candidate over a broad range of masses. Ultralight, asteroid-mass PBHs with masses around1017g are particularly interesting as current observations allow them to constitute the entire DM density. PBHs in this mass range emit∼MeV photons via Hawking radiation which can directly be detected by the gamma ray telescopes, such as the upcoming AMEGO. In this work we forecast how well an instrument with the sensitivity of AMEGO will be able to detect, or rule out, PBHs as a DM candidate, by searching for their evaporating signature when marginalizing over the Galactic and extra-Galactic gamma-ray back-grounds. We find that an instrument with the sensitivity of AMEGO could exclude nonrotating PBHs as the only DM component for masses up to7×1017g at 95% confidence level for a monochromatic mass distribution, improving upon current bounds by nearly an order of magnitude. The forecasted constraints are more stringent for PBHs that have rotation, or which follow extended mass distributions

Anupam Ray↗

Prospects for indirect MeV dark matter detection with gamma rays in light of cosmic microwave background constraints

The self-annihilation of dark matter particles with mass in the MeV range can produce gamma rays via prompt or secondary radiation. The annihilation rate for such light dark matter particles is however tightly constrained by cosmic microwave background (CMB) data. Here we explore the possibility of discovering MeV dark matter annihilation with future MeV gamma-ray telescopes taking into account the latest and future CMB constraints. We study the optimal energy window as a function of the dominant annihilation final state. We consider both the (conservative) case of the dwarf spheroidal galaxy Draco and the (more optimistic) case of the Galactic center. We find that for certain channels, including those with one or two monochromatic photon(s) and one or two neutral pion(s), a detectable gamma-ray signal is possible for both targets under consideration and compatible with CMB constraints. For other annihilation channels, however, including all leptonic annihilation channels and two charged pions, CMB data rule out any significant signal of dark matter annihilation at future MeV gamma-ray telescopes from dwarf galaxies, but possibly not for the Galactic center.

79 ASTRONOMY AND ASTROPHYSICS↗

Pump–probe spectrometer for measuring x-ray induced strain

A hard x-ray pump–probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. In conclusion, we present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging spectrophotometry of the nuclear outflow of NGC 1068

This observational program (in conjunction with R. B. Tully (IfA, Honolulu), and J. Bland (Rice U., Houston)) aims to constrain the kinematic organization and dominant excitation mechanisms of ionized gas in active galaxies. More generally, researchers are interested in the dynamics of radiative, supersonic flows in the Interstellar Medium (ISM). Imaging Fabry-Perot interferometers and low-noise Charge Coupled Devices (CCDs) are used for complete spatial coverage of the complex gas distribution in circumnuclear narrow-line regions (NLRs). Extranuclear emission line widths in NLRs can exceed 3000 km s(-1), so to avoid inter-order confusion researchers use an etalon of 4000 km s(-1) free spectral range to map (N II) lambda lambda 6548, 6583 and H alpha. To maximize spatial resolution, researchers select nearby active systems independent of luminosity but known to possess interesting morphologies and/or high-velocity extranuclear ionized gas. Monochromatic images Full Width Half Maximum (FWHM) approx. 65 km s(-1) have thus far been obtained in 1 second or better seeing at the U. Hawaii 2.2m, CFH 3.6m, and CTIO 4.0m telescopes. These are stacked into grids of line profiles, of spectrophotometric quality, at sub-arcsecond increments across a 3 second field. To handle the approx. 20,000 to 300,000 useful spectra that arise from a typical night's work, researchers have developed a complete analysis and reduction package for VAX and Sun image workstations. Reduction involves parametrization of approx. 10 to the 8th raw data points to a few maps (e.g., velocities of each kinematic subsystem, continuum-free line fluxes) containing approx. 10 to the 5th pixels. Researchers identify kinematic and structural symmetries by examining these maps and the point to point variations of the synthesized line profiles. The combination of monochromatic images and full spatial sampling of line profiles has allowed them to isolate such symmetries and has led to reliable kinematic deprojections.

Cecil, Gerald↗

Quantitative spatiotemporal density evolution of aluminum heated purely by monochromatic electrons

A spatially resolved air-wedge shearing interferometer and shadowgraph diagnostic provides measurements of electron density with a resolution of ∼40 μm. A ∼100-ns-long, monoenergetic electron bunch at 19.8 MeV and a current of 1.4 kA (8.5×1014 e−) heats 100-μm-thick aluminum (Al) foils in a 1-mm-spot to Te∼1 eV. A 5-ns-long, ∼60 mJ, frequency doubled Nd:YAG laser probes the dense Al plasma. Electron densities up to 1020cm−3 are resolved; the maximum resolvable density is limited by opacity, transmission, and spatial fringe density achievable with the detector. This diagnostic provides measurements of the total phase shift, transmission, and electron density. Several measurements at different time slices provide the ability to determine the velocity of the leading edge of the shadowgraph and compare it to the motion of different density shells. These measurements are also compared to radiation hydrodynamics simulations. A rough quantitative agreement is shown between the hydro simulations and the measurements; there are differences in the exact density distributions.

Coleman, J. E. (ORCID:0000000308873757)↗

CMB constraints on the stochastic gravitational-wave background at Mpc scales

We present robust constraints on the stochastic gravitational waves (GWs) at Mpc scales from the cosmic microwave background (CMB) data. CMB constraints on GWs are usually characterized as the tensor-to-scalar ratio, assuming specifically a power-law form of the primordial spectrum, and are obtained from the angular spectra of CMB. Here, we relax the assumption of the power-law form, and consider to what extent one can constrain a monochromatic GW at shorter wavelengths. Previously, such a constraint has been derived at the wavelengths larger than the resolution scale of the CMB measurements, typically above 100 Mpc (below 10 -16 Hz in frequency). However, GWs whose wavelength is much shorter than 100 Mpc can imprint a small but non-negligible signal on CMB anisotropies at observed angular scales, ℓ < 1000 . Here, using the CMB temperature, polarization, and lensing data set, we obtain the best constraints to date at 10 -16 - 10 -14 Hz of the GWs produced before the time of decoupling, which are tighter than those derived from the astrometric measurements and upper bounds on extra radiations. In the future, the constraints on GWs at Mpc scales will be further improved by several orders of magnitude with the precision B -mode measurement on large scales, ℓ < 100 .

79 ASTRONOMY AND ASTROPHYSICS↗

Laser mode effects on the ion acceleration during circularly polarized laser pulse interaction with foil targets

Ion acceleration by circularly polarized laser pulses interacting with foil targets is studied using two dimensional particle-in-cell simulations. It is shown that laser pulses with transverse super-Gaussian profile help in avoiding target deformation as compared with the usual Gaussian pulse. This improves monochromaticity of the accelerated ion spectrum. Two kinds of surface instabilities have been found during the interaction. These instabilities can potentially break the target and destroy the quasimonoenergetic character of the final ion spectrum. Combined laser pulses with super-Hermite and Gaussian modes are used to improve the ion acceleration and transverse collimation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoelectrochemical and photosensing behaviors of hydrothermally grown ZnO nanorods

ZnO nanorods have been grown on indium-tin-oxide coated glass substrates by a low cost chemical process. Current-voltage characteristics have been studied using ZnO nanorods as photoanode in an electrochemical cell. The flat band voltage shift and depletion width of ZnO nanorods/electrolyte interface have been estimated from Mott-Schottky (MS) characteristics. The electrochemical impedance measurements have been carried out to study the charge transport mechanism at the semiconductor-electrolyte interface under dark and white light (100 mW/cm{sup 2}) illumination. The doping concentration of nanorods has been extracted from MS plot. Photoresponse behavior of ZnO nanorods is found to be enhanced than seed layers with the incident of white light. Spectral dependent photovoltage of ZnO nanorods has been carried out using monochromatic light of wavelength 250–600 nm. The photopotential recovery time has been estimated for nanorods and seed layers. The stability of ZnO nanorods as a photoanode has been investigated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Study of multilayer-reflected beam profiles and their coherence properties using beamlines ID19 (ESRF) and 32-ID (APS)

The use of multilayer mirrors is an interesting alternative for reflective X-ray monochromatization with respect to reflection from crystal optics. The increased photon flux density due to the multilayers' larger bandwidth is of crucial importance for, e.g, full-field X-ray imaging applications. Drawbacks are the introduced modifications of the reflected beam profile as well as a certain loss of coherence, summarized as wavefront degradation. Our recent work has shown that the modification of the beam profile can vary with, e.g., the material composition of the coating applied. In order to verify our findings, a beamline round-robin has been initiated, comparing the wavefront profiles after reflection by selected multilayers at beamlines 32-ID (Advanced Photon Source) and ID19 (European Synchrotron Radiation Facility) with our initial results acquired at BM05 (ESRF) [1].

43 PARTICLE ACCELERATORS↗

2D surface temperature measurement of plasma facing components with modulated active pyrometry

In nuclear fusion devices, such as Tore Supra, the plasma facing components (PFC) are in carbon. Such components are exposed to very high heat flux and the surface temperature measurement is mandatory for the safety of the device and also for efficient plasma scenario development. Besides this measurement is essential to evaluate these heat fluxes for a better knowledge of the physics of plasma-wall interaction, it is also required to monitor the fatigue of PFCs. Infrared system (IR) is used to manage to measure surface temperature in real time. For carbon PFCs, the emissivity is high and known (ε ~ 0.8), therefore the contribution of the reflected flux from environment and collected by the IR cameras can be neglected. However, the future tokamaks such as WEST and ITER will be equipped with PFCs in metal (W and Be/W, respectively) with low and variable emissivities (ε ~ 0.1–0.4). Consequently, the reflected flux will contribute significantly in the collected flux by IR camera. The modulated active pyrometry, using a bicolor camera, proposed in this paper allows a 2D surface temperature measurement independently of the reflected fluxes and the emissivity. Experimental results with Tungsten sample are reported and compared with simultaneous measurement performed with classical pyrometry (monochromatic and bichromatic) with and without reflective flux demonstrating the efficiency of this method for surface temperature measurement independently of the reflected flux and the emissivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗