Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Improvements in the Method of Radiation Anomaly Detection by Spectral Comparison Ratios

Algorithms for detecting illicit gamma radiation sources must respond to a wide variety of threat signatures and ignore a wider variety of clutter. Previously, we described the Nuisance-rejection Spectral Comparison Ratio Anomaly Detection (N-SCRAD) method for indicating the presence of threat sources during mobile search operations. Our method relies on the formulation of radiation alarm test statistics applied to detector counts in numerous spectral regions of interest and our test statistics are standardized by local estimates of background variability. In this work we present a new automated procedure for selecting test statistics and specifying the regions of interest based on minimizing detectable count rates of prototype threat spectra at a specified false positive rate using simulated annealing. The new procedure can be applied to configuring the detection algorithm when the prototype threats are many and diverse without significantly compromising the detection sensitivity to any one of them. N-SCRAD makes use of estimates of background variability obtained during a search from prior measurements of background. In applications such estimates made purely from past measurements sometimes do not extrapolate well to current conditions. In this work we present a new method for correcting those estimates to current conditions of the total count rate. We demonstrate that the correction lowers detection thresholds for a specified false positive rate, enabling greater sensitivity to targets. The two proposed improvements to N-SCRAD maximize detection power for the expected variety of possible threats while reducing or maintaining the false positive rate.

Anomaly detection, Gamma-ray spectroscopy, Radiati↗

Energy migration and scintillation kinetics in compositionally complex (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce single crystal scintillator

It is well-established that compositional tuning through binary admixture can improve scintillation performance in several materials systems, including Ce-activated garnets. Although recent work on ternary or quaternary cation admixture shows promise, the impact of this increased compositional complexity on thermal stability and carrier-defect dynamics has not been addressed. Here, we investigate a compositionally complex garnet, (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce (GYTLAG), grown by the Czochralski method using temperature-dependent photoluminescence (PL), PL decay, and thermoluminescence (TL). PL and PL decay measurements support a thermally activated Tb 3+ -Ce 3+ energy transfer, where Tb 3+ emission dominates below 60 K, but Ce 3+ emission increases from 20-300 K. Thermal quenching of Ce 3+ emission occurs around T 50 = 508 K, with an activation energy of 0.6 eV. TL and wavelength-resolved TL spectra from 20–500 K show that GYTLAG contains similar trap groups to LuAG but with a broader distribution of glow peaks below room temperature, possibly caused by quaternary cation mixing. A combination of dose dependence, partial cleaning and initial rise, and glow curve fitting to a first order continuous Gaussian distribution model are used to understand the contribution of electronic point defects to scintillation decay and afterglow at room temperature. Furthermore, these results inform how increased compositional complexity influences recombination dynamics in garnet scintillators.

Compositionally complex↗

Energy Calibration of Gamma Spectra in Plastic Scintillators using Compton Kinematics

This paper describes a simple and practicable method for assigning energy values to gamma-ray pulse-height distributions measured with polyvinyl toluene based detectors. It is based upon the characteristic shape of the spectrum in the region of maximum energy deposition resulting from a single Compton scattering. The validity of this method is first demonstrated by applying it to a set of NaI(Tl) spectra, and comparing those results to the standard photo-peak method of calibrating the same spectra. The method is then applied to a set of polyvinyl toluene derived spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to. Energy calibration of gamma spectra in plastic scintillators using Compton kinematics [Nucl. Instr. and Meth. A 594 (2008) 232–243]

In recent work at our laboratory, we were re-examining our data and found an inconsistency between the values listed for 137 Cs in Table 2 (Siciliano et al. 2008) and results plotted for that source in Figures 11 and 12. In the course of fitting the parabolic function (Equation 4) to the Compton maxima, two ranges of channels were used when determining the parameters for 137 Cs. The parabolic fit curve shown in Figure 11 resulted from fitting channels 50 to 70. The parameters for that fit are: are: A = 0.972(12), B = 1.42(24) x 10 -3 , and C NO = 60.2(5). The parameters for 137 Cs listed in Table 2 (and also used to determine the calibration relations in Figure 12—the main result of this paper) came from fitting the 137 Cs data in channels 40 to 80. Although the curves plotted from these two different sets of parameters would be visually distinguishable in Figure 11, when incorporated with the other isotope values shown in Figure 12 to obtain the linear energy-channel fit, the 50-70 channel parameter set plus the correction from the Compton maximum to the Compton edge gives a negligible change in the slope [6.470(41) as opposed to the reported 6.454(15) keV/channel] and a small change in the intercept [41(8) as opposed to 47(3) keV] for the dashed line. The conclusions of the article therefore do not change as a result of this inconsistency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predictive model of scintillator plastic fogging in portals

We have developed a science-based predictive model for fogging of the scintillator plastics deployed in radiation portal monitors. The only input required is the weather conditions [i.e., daily high and low, for temperature and relative humidity (R.H.)]. The code utilizes this information, together with a thermodynamic model of the water content in equilibrium with the plastic surface, a diffusion model of the water transport into the interior of scintillator plastic panel, and a comparison of the resulting paired “water-content/night-temperature” points as a function of position in the panel against an empirical “fog-line” that establishes a water/temperature criterion for the onset of fogging. In conclusion, we have analyzed the behavior of several representative portal monitor sites, and the output of the model analysis is reasonably consistent with observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nature of Moisture-Induced fogging defects in scintillator plastic

Polyvinyl toluene (PVT) scintillator plastic may degrade in the field due to inward water diffusion at elevated temperatures, which exceeds the saturation limit at lower temperatures, and after long periods of time (e.g., many years), leads to the formation of disk-like defects that attenuate scintillation light, leading to detector degradation. In this work, using fractography and high-magnification optical and electron microscopy to characterize the water-induced defects, a model of the fogging process is hypothesized as follows: excess water present at low temperatures diffuses to spheroids to minimize contact with the hydrophobic polymer. Through the hydrophobic effect, the entropy of water increases by forming nanoclusters which minimizes the contact between the water and the PVT. As the water nanoclusters grow, they break and fold the polymer into densely-packed crystalline regions creating more space for water within the spheroids. The polymer outside the spheroid resists the shrinkage which builds up tension within the spheroid. Once the tensile stress exceeds the yield strength of the plastic, the spheroid is torn in half resulting in a defect. Excess water then drains into the cavities along the disk thereby further increasing its entropy. Slower cooling (over 1 day) leads to larger spheroids and hence, larger “permanent” defects. Freezing causes some defects to further grow due to the expansion of water to ice. These findings imply that the remaining lifetime of scintillator plastic in the field could be predicted using temperature and humidity data thereby mitigating security risks of degraded radiation portal monitors.

36 MATERIALS SCIENCE↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Czochralski Growth and Characterization of a Compositionally Complex Rare Earth Aluminum Garnet Scintillator: (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce

Compositionally complex oxides have garnered increasing interest for their enhanced phase stability and tunable functional properties, yet their development as bulk single crystal scintillators remains limited. Herein, we report the Czochralski growth and characterization of (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce (GYTLAG), a compositionally complex garnet incorporating four dodecahedrally coordinated principal rare earth elements. The garnet phase was confirmed by powder and single crystal X-ray diffraction, and macroscopic defects are described. X-ray absorption near-edge structure measurements confirm the 3+ oxidation state of all rare earths and support their occupation of the same crystallographic site; white line intensity variations correlate with the anticipated segregation behavior. Elemental segregation is quantified by SEM/EDS and ICP-OES, and a linear trend was established between the segregation coefficient and the difference between each rare earth’s ionic radius (r) and the average ionic radius (AIR) of the dodecahedral site. This trend offers a predictive framework for compositional control in future REAG crystals grown by the Czochralski method. Photoluminescence and radioluminescence measurements reveal both Ce 3+ and Tb 3+ emission. Scintillation pulses exhibit four-component decay with dominant ~230 µs and ~1.2 ms components, and the light yield is estimated to be up to 43,000 ph/MeV under 137Cs γ-ray excitation. GYTLAG also demonstrates a strong radioluminescence efficiency and 50% lower afterglow at 20 ms compared to a LuAG:Ce reference, underscoring its promise for scintillator applications.

Compositionally complex oxide, high entropy oxide,↗

Measurement of Indoor Radon-222 and Radon-220 Concentrations in Central Japan

A passive-type radon/thoron detector was used for measuring indoor radon and thoron concentrations at 90 dwellings in Aichi and Gifu prefectures in central Japan during 90 days from December, 2006 to March, 2007. The radon and thoron concentrations were 21.1 Bq/m3 and 25.1 Bq/m3, respectively. The dose due to radon and thoron in dwellings was roughly evaluated as 0.7 mSv/y and 2.4 mSv/y, respectively. The examination of the geological factor and house condition having an effect on indoor radon concentration was performed.

54 ENVIRONMENTAL SCIENCES↗

The Japanese Radon and Thoron Reference Chambers

Passive detectors used for large-scale and long-term surveys are generally calibrated in a well-controlled environment such as a radon chamber. It has been also pointed out that some of them are sensitive to thoron. Thus it is necessary to check the thoron contribution to the detector response with the proposed or similar test before practical use. The NIRS accommodates radon/aerosol and thoron chambers for quality assurance and quality control of radon measurements. Thus both chambers work so well that they can supply us with the calibration technique and consequently, a good level of knowledge of the radon and thoron issue.

54 ENVIRONMENTAL SCIENCES↗

External occupational exposures in some NORM industries located at the South-West of Spain

Detailed mappings of the external exposures which can be received by the workers in two NORM industrial factories located at the South-West of Spain have been performed: one devoted to the production of phosphoric acid, and the other devoted to the production of titanium dioxide pigments. In most places of the analyzed factories, the external exposures are moderated, although in some specific points, and associated to the presence of scales, their values are clearly higher. Nevertheless, under normal running conditions, the contribution of the external exposures to the effective doses received by the workers is lower than 1 mSv/y because the worker occupancy factors values are very low in the places with the highest external exposures.

54 ENVIRONMENTAL SCIENCES↗

Variations of Radon Risk with Changing Mortality Rates

This study examines the variation of radon risks with changing mortality rates. The Canadian age-specific mortality rates averaged over five year periods from 1986 to 1990 and from 1996 to 2000 were used in the risk calculations. Because of the synergistic interaction between smoking and radon, the risk of radon induced lung cancer for Canadian men decreased with the declining lung cancer mortality rates while for Canadian women the radon risks increased with the rising lung cancer mortality rates.

60 APPLIED LIFE SCIENCES↗

Ionizing Radiation Dose Due to the Use of Agricultural Fertilizers

The transference of radionuclides from the fertilizers to/and from soils to the foodstuffs can represent an increment in the internal dose when the vegetables are consumed by the human beings. This work evaluates the contribution of fertilizers to the increase of radiation level in the environment and of dose to the people. Samples of fertilizers, soils and vegetables produced in farms located in the neighbourhood of Sao Paulo city in the State of Sao Paulo, Brazil were analysed through gamma spectroscopy. The values of specific activity of {sup 40}K, {sup 238}U and {sup 232}Th show that there is no significant transference of natural radionuclides from fertilizers to the final product of the food chain. The annual committed effective dose due to the ingestion of {sup 40}K contained in the group of consumed vegetables analysed in this work resulted in the very low value of 0.882 {mu}Sv.

61 RADIATION PROTECTION AND DOSIMETRY↗

The effect of geological and geographical features on environmental radiation

The gamma-ray dose rates were measured in Gifu and Tokushima Prefectures in Japan. Measurements were carried out by the car-borne survey method. The dose rate in basaltic terrain in Tokushima prefecture was almost same as average of basaltic terrain in Japan. On the other hand, the dose rate in basaltic terrain in Gifu Prefecture was not same. In situ measurement of terrestrial gamma-ray dose rate was carried out in this terrain to examine its cause. As a result, it was estimated that soil of rhyolite which attributed to neighbor terrain have deposited on this terrain.

54 ENVIRONMENTAL SCIENCES↗

Electrochemical Behavior of Disposable Electrodes Prepared by Ion Beam Based Surface Modification for Biomolecular Recognition

Many important technological advances have been made in the development of technologies to monitor interactions and recognition events of biomolecules in solution and on solid substrates. The development of advanced biosensors could impact significantly the areas of genomics, proteomics, biomedical diagnostics and drug discovery. In the literature, there have recently appeared an impressive number of intensive designs for electrochemical monitoring of biomolecular recognition. Herein, the influence of ion implanted disposable graphite electrodes on biomolecular recognition and their electrochemical behaviour was investigated.

60 APPLIED LIFE SCIENCES↗

N- and P-Type Cluster Source

We describe our newest ClusterIon registered source, and show detailed data for B{sub 18}H{sub x}{sup +}, C{sub 7}H{sub 7}{sup +}, C{sub 16}H{sub x}{sup +}, P{sub 4}{sup +}, and As{sub 4}{sup +} beams. These species are derived from both low-temperature solids and gaseous sources. 2D beam profiles are presented, along with mass spectra, beam current performance, and long-term beam reproducibility. The data were collected using the injection stage of a commercial ion implanter equipped with a 120 degree analyzer magnet. Beam profiles at magnet entrance and exit planes were produced using a specially designed 2D profiler. Beam currents were measured after mass analysis using a Faraday cup over an effective energy range of 200 eV to 10 keV.

43 PARTICLE ACCELERATORS↗