Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Performance of Thin-Window Silicon Drift Detectors

Several sets of hexagonal Silicon Drift Detector (SDD) arrays were produced at BNL and by a commercial vendor, KETEK. Each array consists of 14 independent detectors (pixels) and two additional test pixels at two of the corners. The side of the detector upon which the X-ray radiation is incident (window side) has a thin junction covering the entire active area. The opposite side (device side) contains a drift-field electrode structure in the form of a hexagonal spiral and an electron collecting anode. There are 4 guard rings surrounding the 14-pixel array area on both sides of the detector. Within each array, 7 of the pixels have an aluminum field plate - interrupted spirals that stabilize the electric potential under the Si-SiO2 interface, while the other 7 do not. The drift field in the silicon volume is controlled by three biases: one is applied to a rectifying contact, one to the detector entrance window, and the third to a contact on the outer portion of the spiral common to all pixels in the array. Some arrays have been newly measured in NSLS beam line U3C at BNL. The complete assemblies were installed in the vacuum and cooled to ?27 C. During this run, spectra for energies ranging between 400 and 900 eV were collected in several pixels, some with field plates and others without. The detailed testing results of several arrays are reported here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon–hadron detector of the carpet-2 array

The 1-GeV muon–hadron detector of the Carpet-2 multipurpose shower array at the Baksan Neutrino Observatory, Institute for Nuclear Research, Russian Academy of Sciences (INR, Moscow, Russia) is able to record simultaneously muons and hadrons. The procedure developed for this device makes it possible to separate the muon and hadron components to a high degree of precision. The spatial and energy features of the muon and hadron extensive-air-shower components are presented. Experimental data from the Carpet-2 array are contrasted against data from the EAS-TOP and KASCADE arrays and against the results of the calculations based on the CORSIKA (GHEISHA + QGSJET01) code package and performed for primary protons and iron nuclei.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on anisotropy of cosmic ray distribution with a small array of water Cherenkov detectors

The study of the anisotropy of the arrival directions is an essential tool to investigate the origin and propagation of cosmic ray primaries. A simple way of recording many cosmic rays is to record coincidences between a number of detectors. We have monitored multi-TeV cosmic rays by a small array of water Cherenkov detectors in Tehran (35 deg. 43{sup '} N, 51 deg. 20{sup '} E, 1200 m above sea level). More than 1.1x10{sup 6} extensive air shower events were recorded. In addition to the Compton-Getting effect due to the motion of the Earth in the Galaxy, an anisotropy has been observed which is due to a unidirectional anisotropy of cosmic ray flow along the Galactic arms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative secondary electron detection

Quantitative Secondary Electron Detection (QSED) using the array of solid state devices (SSD) based electron-counters enable critical dimension metrology measurements in materials such as semiconductors, nanomaterials, and biological samples (FIG. 3). Methods and devices effect a quantitative detection of secondary electrons with the array of solid state detectors comprising a number of solid state detectors. An array senses the number of secondary electrons with a plurality of solid state detectors, counting the number of secondary electrons with a time to digital converter circuit in counter mode.

47 OTHER INSTRUMENTATION↗

BlueSTEAl: A pair of silicon arrays and a zero-degree phoswich detector for studies of scattering and reactions in inverse kinematics

BlueSTEAl, the Blue (aluminum chamber of) Silicon TElescope Arrays for light nuclei, has been developed to study direct reactions in inverse kinematics, as well as scattering and breakup reactions using radioactive ion beams. It is a detector system consisting of a pair of annular silicon detector arrays and a zero-degree phoswich plastic scintillator. For typical binary reaction studies in inverse kinematics, light ions are detected by the Si array in coincidence with heavy recoils detected by the phoswich placed at the focal-plane of a zero-degree magnetic spectrometer. The Si array can also be used to detect light nuclei such as beryllium and carbon with clear isotope separation, while the phoswich can also be placed at zero degrees without a spectrometer and used as a high-efficiency beam counting monitor with particle identification capability at the rate of up to ~5 × 10 4 particles per second. This paper reports on the capabilities of BlueSTEAl as determined by recent experiments performed at the Texas A&M Cyclotron Institute. Furthermore, the device is also anticipated to be used in future experiments at other radioactive ion beam facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prototype Scintillation Detector with Photosensors Based on Silicon Photomultiplier Arrays

A prototype scintillation detector with photosensors based on silicon photomultiplier (SiPM) arrays is described. Such a method of data-taking will make it possible to obtain an image (snapshot) of the event and, thereby, to separate different types of events (particle interactions) in the detector. For this purpose, the characteristics of SiPMs have been studied and a calibration measurement technique developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calculation and verification of the geometrical factors for the NPDGamma experiment

The NPDGamma experiment measures the parity-violating asymmetry in gamma-ray emission in the capture of polarized neutrons on liquid parahydrogen. The sensitivity to the asymmetry for each detector in the array is used as a parameter in the extraction of the physics asymmetry from the measured data. The detector array is approximately cylindrically symmetric around the target and a step-wise sinusoidal function has been used for the sensitivity in the previous iteration of the NPDGamma experiment, but deviations from cylindrical symmetry necessitate the use of a Monte Carlo model to determine corrections to the geometrical factors. For the calculations, source code modifications to MCNPX were done in order to calculate the sensitivity of each cesium iodide detector to the physics asymmetry. We describe the MCNPX model and results from calculations and how the results are validated through measurement of the parity violating asymmetry of gamma-rays from neutron capture on chlorine.

Grammer, K. B.↗

TU-F-BRE-01: A High Resolution Micro Fiber Scintillator Detector Optimized for SRS and SBRT in Vivo Real Time Treatment Verification

Purpose: We have built a high resolution real time scintillating fiber detector prototype to determine in real time the accuracy of stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) treatments when only a fraction of the planned dose was delivered. The motivation of this work is to enhance dose delivery accuracy and to achieve error free radiosurgery. Methods: A high density array of scintillating fibers and a high speed photo detectors array were integrated to implement a high resolution real time dosimeter that can sample with high resolution pulsed SRS and SBRT beams cross sections. The high efficiency of the developed system allows to read each linac pulse in real time and to compute the accumulated dose and dose errors when only a fraction of the beam was delivered. The fibers are highly packed in a substrate that is directly coupled to two 128 pixel arrays with a pitch matching the fiber spacing to achieve accurate spatial localization. The small cross section of the fiber array allows stacking multiple fiber arrays to measure independent angular profiles that are digitally processed in parallel for real time dosimetry. Results: We implemented a high density array detector prototype with a pitch of 0.5 mm, readout speed of 1.2 msec, and a response time of 0.5 usec. The fast reading speed has the capability to determining the dose in flattening free filter beams. The detector can be installed in transmission mode at the output port of a micro-MLC. Treatment deviations smaller than 3% are detected when less than 1/100 of the planned dose was delivered. Conclusions: We built a prototype of a high resolution fiber scintillator array detector for SRS and SBRT in vivo dosimetry. Results show that the developed detector has the potential to assure error free SRS and SBRT treatments.

60 APPLIED LIFE SCIENCES↗

Arrays of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors: Results From a $4\times 4$ Array Prototype

Position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors offer a unique capability for correcting the response nonuniformities caused by crystal defects. This allowed us to achieve high energy resolution, while using typical-grade commercial CZT crystals with relaxed requirements to their quality, thus reducing the overall cost of detectors. Another advantage of the VFG detectors is that they can be integrated into arrays and used in small compact hand-held instruments or large-area gamma cameras that will enhance detection capability for many practical applications, including nonproliferation, medical imaging, and gamma-ray astronomy. Here in this paper, we present the results from testing small array prototypes coupled with front-end application-specified integrated circuit. Each detector in the array is furnished with 5-mm-wide charge-sensing pads placed near the anode. The pads signals are converted into XY coordinates, which combined with the cathode signals (for Z coordinates) provide 3-D position information of all interaction points. The basic array consists of a number of detectors grouped into 2×2 subarrays, each having a common cathode made by connecting together the cathodes of the individual detectors. Lastly, these features can significantly improve the performance of detectors while using typical-grade low-cost CZT crystals to reduce the overall cost of the proposed instrument.

3-D position-sensitive virtual Frisch-grid (VFG) d↗

INDICATIONS OF INTERMEDIATE-SCALE ANISOTROPY OF COSMIC RAYS WITH ENERGY GREATER THAN 57 EeV IN THE NORTHERN SKY MEASURED WITH THE SURFACE DETECTOR OF THE TELESCOPE ARRAY EXPERIMENT

We have searched for intermediate-scale anisotropy in the arrival directions of ultrahigh-energy cosmic rays with energies above 57 EeV in the northern sky using data collected over a 5 yr period by the surface detector of the Telescope Array experiment. We report on a cluster of events that we call the hotspot, found by oversampling using 20° radius circles. The hotspot has a Li-Ma statistical significance of 5.1σ, and is centered at R.A. = 146.°7, decl. = 43.°2. The position of the hotspot is about 19° off of the supergalactic plane. The probability of a cluster of events of 5.1σ significance, appearing by chance in an isotropic cosmic-ray sky, is estimated to be 3.7 × 10{sup –4} (3.4σ)

79 ASTRONOMY AND ASTROPHYSICS↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DRAGO gamma camera

In this work, we present the results of the experimental characterization of the DRAGO (DRift detector Array-based Gamma camera for Oncology), a detection system developed for high-spatial resolution gamma-ray imaging. This camera is based on a monolithic array of 77 silicon drift detectors (SDDs), with a total active area of 6.7 cm{sup 2}, coupled to a single 5-mm-thick CsI(Tl) scintillator crystal. The use of an array of SDDs provides a high quantum efficiency for the detection of the scintillation light together with a very low electronics noise. A very compact detection module based on the use of integrated readout circuits was developed. The performances achieved in gamma-ray imaging using this camera are reported here. When imaging a 0.2 mm collimated {sup 57}Co source (122 keV) over different points of the active area, a spatial resolution ranging from 0.25 to 0.5 mm was measured. The depth-of-interaction capability of the detector, thanks to the use of a Maximum Likelihood reconstruction algorithm, was also investigated by imaging a collimated beam tilted to an angle of 45 deg. with respect to the scintillator surface. Finally, the imager was characterized with in vivo measurements on mice, in a real preclinical environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype for SANDD: A highly-segmented pulse-shape-sensitive plastic scintillator detector incorporating silicon photomultiplier arrays

We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 × 8 array of plastic scintillator segments coupled to two 5 cm × 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will eventually comprise a central module of 64 elongated segments of 6 Li-doped pulse-shape-sensitive scintillator rods, each with a square cross section of 5.4 mm × 5.4 mm, surrounded by larger cross section bars of the same material. The most important metrics with the potential to impact the performance of the central module of SANDD are neutron and gammaray pulse-shape sensitivity using silicon photomultipliers (SiPMs), particle identification via scintillator rod multiplicity, and energy and position resolution. As a first step, we constructed a prototype detector to investigate the performance of a central SANDD-like module using two 64-channel SiPM arrays and rods of undoped pulse-shape-sensitive plastic scintillator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Octavius 4D characterization for flattened and flattening filter free rotational deliveries

Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%/3 mm tolerances and 2%/2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution.Results: A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy/min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 × 2 cm{sup 2} fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4° of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%/3 mm and 2%/2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film.Conclusions: The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is a dosimetrically and mechanically stable device for pretreatment verification of FF and FFF RapidArc treatments. Further improvements may be possible through use of a detector array with higher spatial resolution (detector size and/or detector spacing)

62 RADIOLOGY AND NUCLEAR MEDICINE↗