Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Intrinsic structural defects in monolayer molybdenum disulfide

Monolayer molybdenum disulfide (MoS2) is a two-dimensional direct band gap semiconductor with distinctive mechanical, electronic, optical and chemical properties that can be utilized for novel nanoelectronics and optoelectronics devices. The performance of these electronic devices strongly depends on the quality and defect morphology of the MoS2 layers. Yet, little is known about the atomic structure of defects present in monolayer MoS2 and their influences on the material properties. Here we provide a systematic study of various intrinsic structural defects, including point defects, grain boundaries, and edges, in chemical vapor phase grown monolayer MoS2 via direct atomic resolution imaging, and explore their energy landscape and electronic properties using first-principles calculations. We discover that one-dimensional metallic wires can be created via two different types of 60 grain boundaries consisting of distinct 4-fold ring chains. A new type of edge reconstruction, representing a transition state during growth, was also identified, providing insights into the material growth mechanism. The atomic scale study of structural defects presented here brings new opportunities to tailor the properties of MoS2 via controlled synthesis and defect engineering.

Zhou, Wu↗

First Annual Report on Pulsed Thermal Tomography Nondestructive Evaluation of Additively Manufactured Reactor Materials and Components: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This report provides results of preliminary performance evaluation of PTT capability in detection of flaws in metallic structures, as well imaging complex geometry AM structures. Performance of PTT was investigated through modeling and experiments, Computer models of PTT were developed using COMSOL Heat Transfer module. Defects were modeled as cylindrical flat bottom holes (FBH), which is a common model of calibrated material flaws in thermal tomography experiments. Materials considered in this study include stainless steel 316 (SS316), stainless steel 304 (SS304), and Inconel 718. Theoretical analyses were conducted to validate inversion of simulated PTT data with COMSOL for a plate. Subsequently, 3D reconstructions were performed on COMSOL simulations for FBH, revealing a decrease in spatial resolution over depth due to thermal diffusion. The results of this study show that the performance of the inversion algorithm for detecting smaller defects depends strongly on the depth of the defect as well as the incident heat flux. The size of detectable defect was estimated by fitting a Gaussian function to surface temperature profile. The criteria for detectability was taken as 20mK noise equivalent temperature difference (NETD), which is currently the sensitivity limit of high-performance infrared cameras. It was determined through computer simulations that the smallest detectable FBH in SS316 has a 50µm diameter and is located 0.5mm below the plate surface. Preliminary experimental studies were performed to evaluate PTT performance in detecting calibrated flaws using metallic specimens with AM defects simulated as drilled-in FBH’s. High strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The diameters of FBH’s varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanical drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. Finally, PTT capability in imaging several AM structures fabricated from Inconel 718 (IN718) powder feedstock was investigated. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of AM IN718 nozzle plate and a particle filter plate. It was shown that PTT can scan through 2/3in-thick Inconel 718 plates in approximately 15s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages. The results demonstrate the capability of PTT in 3-D imaging of complex geometry AM structures. Intermediate results demonstrated in this report will be developed further to investigate detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Incremental growth of short SWNT arrays by pulsed chemical vapor deposition

Very short, aligned arrays of continuous single wall carbon nanotubes were grown incrementally in steps as small as 25 nm using pulsed chemical vapor deposition. In situ optical extinction measurements indicate that over 98% of the nanotubes reinitiate growth on successive gas pulses, and HRTEM images show that the SWNTs do not exhibit segments, caps, or noticeable sidewall defects resulting from repeatedly stopping and restarting growth. Time-resolved laser reflectivity (3-ms temporal resolution) was used to record the nucleation and growth kinetics for each fast (0.2 second) gas pulse and measure the height increase of the array in situ, providing a "digital" method to incrementally grow short nanotube arrays to precise heights. Derivatives of the optical reflectivity signal reveal distinct temporal signatures for both nucleation and growth kinetics, with their amplitude ratio on the first gas pulse serving as a good predictor for aligned vs. unaligned growth. Incremental growth by pulsed CVD is interpreted in the context of autocatalytic kinetic models as a special processing window in which a sufficiently high flux of feedstock gas drives the nucleation and rapid growth phases of a catalyst nanoparticle ensemble to occur within the temporal period of the gas pulse, but without inducing growth termination.

36 MATERIALS SCIENCE↗

Characterization of structural defects in nuclear graphite IG-110 and NBG-18

Nuclear graphite IG-110 and NBG-18 were examined using X-ray diffraction (XRD), Raman spectroscopy, scanning electron microscope (SEM) and high resolution transmission electron microscope (HR-TEM) to understand the structure and microstructure of nuclear graphite. The lattice parameter (a), degree of graphitization ( ), crystallite size parallel and perpendicular to c-direction (Lc and L ), anisotropy (B), as well as in-plane crystallite size (La) were calculated and compared based on XRD patterns and Raman spectra. Results indicate that IG-110 has a larger crystallite size and higher degree of graphitization, but lower anisotropy than NBG-18. These differences are attributed to the properties of coke source and manufacturing processes. Additionally, the shape of the pores and crystallized filler particles, the interface between binders and fillers, Mrozowski cracks and nano-cracks, and the defects of disclination were observed and characterized from SEM and HR-TEM images. The similarities and differences in microstructure between IG-110 and NBG-18 are discussed. The results in this work provide useful information to guide selection of nuclear graphite for the design of next generation nuclear plants (NGNP).

99 GENERAL AND MISCELLANEOUS↗

4D-STEM Coupled with Unsupervised Machine Learning to Reveal at Large-Scale the Microstructural Evolution in Li- and Mn-Rich Cathodes

Li- and Mn-rich (LMR) layered oxides are known to exhibit a thin surface reconstruction layer, which grows during electrochemical cycling in a manner that depends on exposed crystallographic facets, cycling conditions, and electrolyte chemistry. Direct characterization of this layer has traditionally relied on high-resolution electron microscopy, which is inherently limited to small fields of view. Here, we employ four-dimensional scanning transmission electron microscopy (4D-STEM) combined with unsupervised machine-learning clustering to quantitatively map phase distributions over large areas and track their evolution in LMR cathodes during electrochemical aging. Our results show that the surface reconstruction layer consists predominantly of a rocksalt phase, whose thickness varies across different facets following activation cycling and becomes substantially thicker and more uniform during calendar aging. In contrast, a spinel-like phase is observed within the particle bulk. Large-area phase mapping and correlative high-resolution imaging reveal that this spinel-like phase preferentially nucleates at bulk crystallographic defects, including boundaries between 60°-rotated layered domains and associated mixed-phase regions, rather than exclusively at the particle surface. Our findings establish a mechanistic distinction between surface-driven rocksalt formation and bulk-defect-mediated spinel nucleation while demonstrating the unique capability of 4D-STEM to provide statistically robust, mesoscale insight into complex phase-evolution processes in LMR cathodes.

4D-STEM↗

Experimental investigation of bright spots in broadband, gated x-ray images of ignition-scale implosions on the National Ignition Facility

Bright spots in the hot spot intensity profile of gated x-ray images of ignition-scale implosions at the National Ignition Facility [G. H. Miller et al., Opt. Eng. 443, (2004)] are observed. X-ray images of cryogenically layered deuterium-tritium (DT) and tritium-hydrogen-deuterium (THD) ice capsules, and gas filled plastic shell capsules (Symcap) were recorded along the hohlraum symmetry axis. Heterogeneous mixing of ablator material and fuel into the hot spot (i.e., hot-spot mix) by hydrodynamic instabilities causes the bright spots. Hot-spot mix increases the radiative cooling of the hot spot. Fourier analysis of the x-ray images is used to quantify the evolution of bright spots in both x- and k-space. Bright spot images were azimuthally binned to characterize bright spot location relative to known isolated defects on the capsule surface. A strong correlation is observed between bright spot location and the fill tube for both Symcap and cryogenically layered DT and THD ice targets, indicating the fill tube is a significant seed for the ablation front instability causing hot-spot mix. The fill tube is the predominant seed for Symcaps, while other capsule non-uniformities are dominant seeds for the cryogenically layered DT and THD ice targets. A comparison of the bright spot power observed for Si- and Ge-doped ablator targets shows heterogeneous mix in Symcap targets is mostly material from the doped ablator layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dispersion of Co/CNTs via strong electrostatic adsorption method: Thermal treatment effect

The effect of different thermal treatment temperature on the structure of multi-walled carbon nanotubes (MWCNTs) and Co particle dispersion on CNTs support is studied using Strong electrostatic adsorption (SEA) method. The samples tested by N{sub 2}-adsorption, field emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM). N{sub 2}-adsorption results showed BET surface area increased using thermal treatment and TEM images showed that increasing the thermal treatment temperature lead to flaky CNTs and defects introduced on the outer surface and Co particle dispersion increased.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A full-sky, high-resolution atlas of galactic 12 μm dust emission with WISE

We describe our custom processing of the entire Wide-field Infrared Survey Explorer (WISE) 12 μm imaging data set, and present a high-resolution, full-sky map of diffuse Galactic dust emission that is free of compact sources and other contaminating artifacts. The principal distinctions between our resulting co-added images and the WISE Atlas stacks are our removal of compact sources, including their associated electronic and optical artifacts, and our preservation of spatial modes larger than 1.°5. We provide access to the resulting full-sky map via a set of 430 12.°5 × 12.°5 mosaics. These stacks have been smoothed to 15'' resolution and are accompanied by corresponding coverage maps, artifact images, and bit-masks for point sources, resolved compact sources, and other defects. When combined appropriately with other mid-infrared and far-infrared data sets, we expect our WISE 12 μm co-adds to form the basis for a full-sky dust extinction map with angular resolution several times better than Schlegel et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Three‐dimensional custom‐made carbon‐fiber prosthesis for sternal reconstruction after sarcoma resection

Radical resection is the preferred therapy for primary malignant sternal tumors. Sternal reconstruction is required to guarantee the best preservation of respiratory mechanics, and adequate mediastinal protection and acceptable cosmetic results after extensive tumor resection. A wide variety of methods and materials have been described for sternal reconstruction. Titanium implants are preferred by many surgeons because of their optimal features. However, the smooth surface of the metal prostheses does not facilitate the inward growth of the tissue, and the high density of metal can block the X‐ray and cause adverse effects on postoperative imaging and radiotherapy. Therefore, in this article we present a case of sternal reconstruction by means of a three dimensional (3D) custom‐made carbon‐fiber prosthesis following extensive resection of a sternal synovial sarcoma. The microporous structure on the surface of the carbon fiber composite material facilitates the inward growth of the tissue. Low density (1.5 g/cm 3 ) of carbon‐fiber implant will not block the X‐ray and eliminates the adverse effects caused by metal material of postoperative imaging and radiotherapy. The 3D custom‐made carbon‐fiber prosthesis matched the thoracic defect perfectly and the chest wall reconstruction was stable for more than 24 months.

Wang, Bin↗

In situ nanomechanical testing of twinned metals in a transmission electron microscope

This paper focuses on in situ transmission electron microscope (TEM) characterization to explore twins in face-centered-cubic and body-centered-cubic monolithic metals, and their impact on the overall mechanical performance. Taking advantage of simultaneous nanomechanical deformation and nanoscale imaging using versatile in situ TEM tools, direct correlation of these unique microscopic defects with macroscopic mechanical performance becomes possible. This article summarizes recent evidence to support the mechanisms related to strengthening and plasticity in metals, including nanotwinned Cu, Ni, Al, Au, and others in bulk, thin film, and nanowire forms.

36 MATERIALS SCIENCE↗

Looking at Hubble Through the Eyes of JWST

The phase retrieval algorithm developed for the James Webb Space Telescope (JWST) is used to process archival image data that was originally used to characterize the Hubble primary mirror edge defect. The Hubble mirror conic constant is inferred from these results and comparisons are made with earlier conic values reported by teams comprising the HARP (Hubble Aberration Recovery Project) study. A number of important lessons learned from the Hubble phase retrieval problem are described and a discussion is given on how these have been incorporated into the JWST Observatory design.

Dean, Bruce H.↗

X-37 C/SiC Ruddervator Subcomponent Test Program

Completed thermal-mechanical and mechanical load testing: a) 6 re-entry heating tests (3 with loading to 50% DLL), 3 hypersonic cruise tests with loading to 50% DLL and 4 high-temperature modal survey tests. b) 9 tests to 100% DLL. High-temperature modal survey results were inconclusive due to exceeding capability of some accelerometers. Overall good correlation between analysis and measured results for windward and leeward surface temperatures. Generally poor correlation between analysis and measured results for spindle area temperatures. Excellent test-to-test repeatability in strain and deflection data for 100% DLL testing. In-situ thermography images taken before and after thermal testing showed only minor changes in initial defects. Final detailed thermography tests scheduled for completion in Oct 09. In process of completing test documentation and test data analysis. Final reports complete by Dec 09. All analysis, test data, test plans, reports, photos, etc. will be made available to the technical community via the CMC Wiki.

Hudson, Larry D.↗

Bond Line Thickness Estimation in Composite Structures Using Multiple Inspection Techniques

Imaging and other nondestructive evaluation techniques are commonly used for material characterization and defect recognition in safety critical aerospace applications, with data fusion providing the framework for uncertainty quantification in these contexts. Most commonly, forward physics-based modeling predicts the response conditioned on material properties and defect assumptions, and probabilistic methods are used to infer the hidden state of the subject of the inspection from a combination of prior information, likelihoods, and inspection data. In this paper Bayesian methods are used to estimate bond thickness in lap joints comprised of aluminum adherends using a combination of infrared thermography and ultrasound. The concept of the conflation of probability distributions is applied to combine the posterior distributions derived from thermography and ultrasound and the quality of the fused estimates are compared against the individual estimates against synthetic data that was created to mimic the inspection of a lap joint comprised of aluminum adherends.

thermal nondestructive evaluation↗

Bond Line Thickness Estimation in Composite Structures Using Multiple Inspection Techniques

Imaging and other nondestructive evaluation techniques are commonly used for material characterization and defect recognition in safety critical aerospace applications, with data fusion providing the framework for uncertainty quantification in these contexts. Most commonly, forward physics-based modeling predicts the response conditioned on material properties and defect assumptions, and probabilistic methods are used to infer the hidden state of subject of the inspection from a combination of prior information, likelihoods, and inspection data. In this paper Bayesian methods are used to estimate bond thickness in lap joints comprised of aluminum adherends using a combination of infrared thermography, digital radiography, and ultrasound. The accuracy of the fused estimates are validated against data generated from synthetic specimens, and by comparison against high resolution X-ray computed tomography inspections of built specimens.

thermal nondestructive evaluation↗

Module Degradation Mechanisms Studied by a Multi-Scale Approach

A key pathway to meeting the Department of Energy SunShot 2020 goals is to reduce financing costs by improving investor confidence through improved photovoltaic (PV) module reliability. A comprehensive approach to further understand and improve PV reliability includes characterization techniques and modeling from module to atomic scale. Imaging techniques, which include photoluminescence, electroluminescence, and lock-in thermography, are used to locate localized defects responsible for module degradation. Small area samples containing such defects are prepared using coring techniques and are then suitable and available for microscopic study and specific defect modeling and analysis.

14 SOLAR ENERGY↗

Electron Beam Induced Thickening of the Protective Oxide Layer around Fe Nanoparticles

There are many circumstances in science where the process of measuring the properties of a system alters the system. An imaging process can exert an inadvertent effect on the object being observed. Consequently, what we observe does not necessarily represent what had been present before the observation. Normally this effect can be ignored if the consequence of such a change is believed not to be significant. The expansion of nanostructured materials has made high resolution transmission electron microscopy one of the indispensable tools for probing the characteristics of nano-materials. Modification of nanoparticles by the electron beam during their imaging has been widely noticed and this is generally believed to be due to electron beam induced heating effect, defect formation in the particles, charging of the particle, or excitation of surrounding gases. However, an explicit experimental identification of which process dominates is often very hard to establish. We report the thickening of native oxide layer on iron nanoparticle under electron beam irradiation. Based on atomic level imaging, electron diffraction, and computer simulation, we have direct evidence that the protecting oxide layer formed on Fe nanoparticle at room temperature in air continues to grow during an electron beam bombardment in the vacuum system typical of most TEM systems. Partial illumination of a nanoparticle and observation of the shell thickening conclusively demonstrates that many of the mechanisms postulated to explain such processes are not occurring to a significant extent. The observed growth is not related to the electron beam induced heating of the nanoparticle, or residual oxygen ionization, or establishment of an electrical field, rather it is related to electron beam facilitated mass transport across the oxide layer (a defect related process).

36 MATERIALS SCIENCE↗

SEN Ultra-High Energy Implanter (UHE) Developed for Next Generation Image Sensors

The UHE is an ultra-high energy implanter developed by SEN Corporation. It was derived from the NV-GSD-HE3 by adding six RF resonators to the beam line. This extends performance so that singly charged boron ions can reach 2 MeV with beam current of 0.75 mA. The maximum energy for triple charged boron is 5 MeV with beam current of 1p{mu}A. For phosphorus ions, the UHE can accelerate doubly charged ions up to 4.4 MeV with beam current of 0.35 mA and quadruply charged ions up to 8 MeV with beam current of 1 p{mu}A. The primary application of the UHE is the image sensor market where it is used to increase the depth of CCD photodiodes into the surface of the wafer and thereby permit higher pixel density for image sensors. The second purpose is to improve productivity for relatively high boron doses at energies around 3 MeV. In order to address certain CCD defects, the system includes a state-of-the-art beam profile controller which allows optimization of implant damage and micro-uniformity. The ULE is currently used in production of high-end CCD's.

43 PARTICLE ACCELERATORS↗

Strain mapping at nanometer resolution using advanced nano-beam electron diffraction

In this work, we report on the development of a nanometer scale strain mapping technique by means of scanning nano-beam electron diffraction. Only recently possible due to fast acquisition with a direct electron detector, this technique allows for strain mapping with a high precision of 0.1% at a lateral resolution of 1 nm for a large field of view reaching up to 1 μm. We demonstrate its application to a technologically relevant strain-engineered GaAs/GaAsP hetero-structure and show that the method can even be applied to highly defected regions with substantial changes in local crystal orientation. Strain maps derived from atomically resolved scanning transmission electron microscopy images were used to validate the accuracy, precision and resolution of this versatile technique.

36 MATERIALS SCIENCE↗