Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Substation Configuration Survey for Electromagnetic Coupling Analysis

Impacts of a high-altitude electromagnetic pulse (HEMP) on the power grid are a growing concern due to the increased reliance on the power grid. A critical area of research is quantifying power system equipment response to HEMP since this is not known in general. Substation site surveys were performed at seven high voltage substations across the United States to gather substation layout and construction details pertinent to HEMP coupling calculations and component vulnerability assessments. The primary objective for the survey was to gather information on cable layouts and cable construction within substations. Additional information was also gathered on equipment present within the substations and control house layouts. This report provides information gathered from the substation surveys.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Phone Application to Compute Annual Solar Production of One Panel of a Plug-and-Play Solar Appliance (Cooperative Research and Development Final Report, CRADA Number CRD-19-00832)

The primary goal of the project is to develop a smart phone application (App) that will be available in both the Apple App Store and the Android store that displays results from the NREL's photovoltaic application, PVWatts Calculator, an application that estimates the energy production and cost of energy of grid-connected PV energy systems, and that will provide quick-response changes based on the orientation of the smart phone by the end user.

14 SOLAR ENERGY↗

Computer Science Research Needs for Parallel Discrete Event Simulation (PDES)

Historically, scientific computing efforts have demonstrated the clear need for, and effective use of, supercomputing with traditional time-stepped simulations. Nevertheless, there are several areas in the mission spaces of the U.S. Department of Energy and other agencies waiting to tap advanced computing research using a different, discrete event style of modeling, simulation, and analysis. These span a wide spectrum of applications including energy grid resilience, urban planning and policy, transportation science, building technologies, emergency response and planning, environmental impact analysis, computational epidemiology, Internet communications, cyber security, and cyber-physical systems, to name only a few. Even within traditional scientific applications, the role of discrete event modes of execution is increasing in the form of new event-based mathematical solvers such as quantized state integration methods and discrete-continuous hybrid system solvers. Co-design of advanced supercomputing hardware systems is another area that exploits discrete event simulation at its core for effective analyses. Complex systems, entity behaviors and interconnections play a significant role in all these applications, which are mapped to large-scale models with discrete event formulations. To make advancements in all the aforementioned scientific areas, many technical aspects need to be more thoroughly studied and deeply understood in parallel discrete event simulation (PDES). The unique dynamics inherent in a discrete event modeling approach, by their very nature, intersect and influence the entire stack of the computing system, including (a) the unique nature of the instruction sets exercised in PDES workloads without a predominance of high-precision floating point operations, (b) virtual time-constrained multi-threaded execution of many logical processes per processor, (c) extremely variable and difficult to predict network traffic characteristics, (d) interfaces and inter-dependencies with machine learning and artificial intelligence codes at higher software layers, and (e) highly challenging load balancing needs, especially in effectively accounting for accelerated/extremely heterogeneous computing in current and future high-performance computing systems. Efficient and accurate parallel execution of PDES workloads is also dominated by challenges in dealing with their asynchronous concurrency fundamentally present at the model level. Conservative synchronization, optimistic/speculative synchronization, and their hybrid schemes open new questions in fundamental computer science with respect to reversibility of computation and prediction (lookahead) of behaviors inherent within model codes. On the implementation front, there are relatively few scalable, general-purpose parallel discrete event simulators in the world, and even fewer have been studied on emerging hardware platforms. To enable scientific advances using PDES, the research needs in computer science must also be pursued and met in the intersection of the algorithmic and hardware-aware aspects of scalable PDES engines. This report is aimed at capturing a computer science-oriented view of this important area of research in PDES, presenting a sample of important applications with their inherent discrete event technology elements. Needs are outlined in core areas of parallel discrete event research as well as cross-cutting directions in computer science research that positively impact scientific advancements across several important application areas. A selection of priority research opportunities in advanced computing for PDES is identified to serve as reference for key research topics and their order of importance for scientific advancements.

97 MATHEMATICS AND COMPUTING↗

Computer Science Research Needs for Parallel Discrete Event Simulation (PDES)

Historically, scientific computing efforts have demonstrated the clear need for, and effective use of, supercomputing with traditional time-stepped simulations. Nevertheless, there are several areas in the mission spaces of the U.S. Department of Energy and other agencies waiting to tap advanced computing research using a different, discrete event style of modeling, simulation, and analysis. These span a wide spectrum of applications including energy grid resilience, urban planning and policy, transportation science, building technologies, emergency response and planning, environmental impact analysis, computational epidemiology, Internet communications, cyber security, and cyber-physical systems, to name only a few. Even within traditional scientific applications, the role of discrete event modes of execution is increasing in the form of new event-based mathematical solvers such as quantized state integration methods and discrete-continuous hybrid system solvers. Co-design of advanced supercomputing hardware systems is another area that exploits discrete event simulation at its core for effective analyses. Complex systems, entity behaviors and interconnections play a significant role in all these applications, which are mapped to large-scale models with discrete event formulations.

97 MATHEMATICS AND COMPUTING↗

GridWise Transactive Energy Framework (V.1.1)

Over the past two decades, the use of demand response and other flexible distributed resources for electricity market efficiency and grid reliability has grown dramatically. Federal and state policy objectives point to an important role for customers’ loads, generation, and storage in the management of an increasingly unpredictable power system. As we consider the need to substantially scale the use of flexible distributed energy resources, growing attention has been devoted to the need to address not only the economics of the electricity grid, but also the control system implications, to address grid reliability. This has led to a focus on an area of activity called “Transactive Energy.” Transactive energy (TE) refers to the use of a combination of economic and control techniques to improve grid reliability and efficiency. These techniques may also be used to optimize operations within a customer’s facility. The U.S. Department of Energy has supported the GridWise ® Architecture Council (“the Council”) in developing a conceptual framework for developing architectures and designing solutions related to TE. The goal of this effort is to encourage and facilitate collaboration among the many stakeholders involved in the transformation of the power system and thereby advance the practical implementation of TE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evapotranspiration and runoff from large land areas: Land surface hydrology for atmospheric general circulation models

A land surface hydrology parameterization for use in atmospheric GCM's is presented. The parameterization incorporates subgrid scale variability in topography, soils, soil moisture and precipitation. The framework of the model is the statistical distribution of a topography-soils index, which controls the local water balance fluxes, and is therefore taken to represent the large land area. Spatially variable water balance fluxes are integrated with respect to the topography-soils index to yield our large topography-soils distribution, and interval responses are weighted by the probability of occurrence of the interval. Grid square averaged land surface fluxes result. The model functions independently as a macroscale water balance model. Runoff ratio and evapotranspiration efficiency parameterizations are derived and are shown to depend on the spatial variability of the above mentioned properties and processes, as well as the dynamics of land surface-atmosphere interactions.

Famiglietti, J. S.↗

Annual Sea Level Variability Induced by Changes in Sea Ice Extent and Accumulation on Ice Sheets: An Assessment Based on Remotely Sensed Data

Changes of mean annual net accumulation at the surface on the grounded ice sheets of East Antarctica, West Antarctica, and Greenland in response to variations in sea ice extent are estimated using grid-point values 100 km apart. The data bases are assembled principally by bilinear interpolation of remotely sensed brightness temperature (Nimbus-5 ESMR, Nimbus-7 SMMR), surface temperature (Nimbus-7 THIR), and surface elevation (ERS-1 radar altimeter). These data, complemented by field data where remotely sensed data are not available, are used in multivariate analyses in which mean annual accumulation (derived from firn emissivity) is the dependent variable; the independent variables are latitude, surface elevation, mean annual surface temperature, and mean annual distance to open ocean (as a source of energy and moisture). The last is the shortest distance measured between a grid point and the mean annual position of the 10% sea ice concentration boundary, and is used as an index of changes in sea ice extent as well as of mean concentration. Stepwise correlation analyses indicate that variations in sea ice extent of +/-50 km would lead to changes in accumulation inversely of +/-4% on East Antarctica, +/- 10% on West Antarctica, and +4% on Greenland. These results are compared with those obtained in a previous study using visually interpolated values from contoured compilations of field data; they substantiate the findings for the Antarctic ice sheets (+/-4% on East Antarctica, +/-9% in West Antarctica), and suggest a reduction by one half of the probable change of accumulation on Greenland (from +/-8%). The results also suggest a reduction of the combined contribution to sea level variability to +/- 0.19 mm/a (from +/- 0.22 mm/a).

Zwally, H. J.↗

Grid Integration and Market Analysis of Adjustable-Speed Pumped Storage Hydropower: Preprint

Many of the products and services on the electrical grid are currently provided by the conventional power plants, however the response time from conventional power plants is slow compared to hydropower. Similarly, some services such as spinning reserve can be provided by modern renewable generation (wind or PV), however the renewable generation must be curtailed down, thus there is loss of opportunity to harvest clean energy while operating in spinning reserve mode. On the other hand, Adjustable Speed - Pumped Storage Hydropower (AS-PSH) can readily perform these functions while pumping or generating, thus also taking benefit of energy arbitrage which can increase system efficiency. This paper will present results from production cost models showing the effect of adding AS-PSH 50 MW in size to three regional ISO areas which have different ancillary service markets available and different generation mixes. The benefits to these market areas from the ancillary services that can be provided by the AS-PSH and also the load shifting benefits will be measured with cost savings and additional system flexibility in the day-ahead and real-time markets. The main metrics to provide this insight will be savings in the total system production cost and in variable renewable energy curtailment respectively. The simulated operation of the additional hydropower will be analyzed to determine the breakdown of system cost reduction by ancillary services provided and load shifting.

13 HYDRO ENERGY↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

Lian, Jianming↗

Studying the Impact of IBR Modeling on the Commonly Applied Transmission Line Protective Elements

It is a well-accepted fact that detailed inverter-based resource (IBR) models are needed for electromagnetic transient (EMT) studies, especially for protection studies and protection designs. However, it is not clear which modeling aspects should be included in the EMT model to accurately represent the IBR fault responses. Therefore, this paper addresses this gap by evaluating the impact of key modeling aspects (DC source, inverter model, power control, current/voltage control, and current limiting) on the response of protective relay elements both qualitatively and quantitatively. Both grid-following (GFL) and grid-forming (GFM) IBR models are comprehensively evaluated through a simplified real-world transmission network by varying the IBR modeling aspects, fault locations, and types. The insights and findings from this paper will benefit the power system protection community because this work provides modeling requirements and guidelines for IBR modeling so that correct IBR models will be used for protection scheme settings design.

grid-following inverter↗

Integration of a Smart Outlet-Based Plug Load Management System with a Building Automation System

The growth of and reliance on renewable energy necessitate a multi-pronged approach to achieve grid reliability and economics. As they represent a notable portion of U.S. energy consumption, commercial buildings must play an active role in this effort. Conserving energy and responding to grid conditions through demand flexibility can be achieved through the integration of major building systems. Integration of plug and process loads with lighting and heating, ventilation, and air conditioning systems maximizes the effectiveness of integrated building energy management. In this research, we demonstrate the integration of smart outlets into a building automation system. We cover the installation process as well as the architecture required for smart outlets to communicate data to the building automation system and to receive commands back. After recording power measurements for one week as a baseline, we configured the building automation system to turn the smart outlets on and off according to a set schedule. This resulted in energy savings of 66% during 1 week on 25 plug loads. This work demonstrates that grid-interactive efficient buildings are achievable through building system integration.

building automation system↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Stochastic Optimization for Grid Resilience. FY18 Final Technical Report

The optimal restoration problem lies at the foundation of the evaluation and improvement of resilience in power systems. In this report we present a scalable decomposition algorithm for solving this problem for realistic power systems. The algorithm has been developed in three major research threads, corresponding to the chapters in the present report. Chapter 1 studies mixed-integer programming (MIP) formulations for the requirement that each electrical island that appears after a recon guration must have at least one energized generator. We provide three alternative MIP formulations for this restriction, show their equivalence, and prove that two of them are stronger in terms of their linear programming relaxation than the formulation most commonly used in the power systems literature. Since the time to solve MIPs can vary signi cantly between equivalent formulations, we also present computational experiments on IEEE test systems for the Intentional Controlled Islanding (ICI) and the Black Start Allocation (BSA) problems. We observe that a polynomially separable, exponential in size, strong formulation yields the best performance for the BSA problem and exhibits a comparable performance to a linear in size, weak formulation for the ICI problem. Chapter 2 presents a methodology to generate mixed-integer linear approximations of the AC power ow equations governing lines, transformers (including tap regulators and phase shifters), shunt and series compensators, and consumption responsive to voltage. Our approximations are capable of capturing limitations for power grids under abnormal or uncommon operating conditions where common assumptions used in power ow relaxations may not hold. Particularly, the approximation captures overvoltages under almost no load, which is a major concern when energizing lines after a blackout. The method constructs piecewise linear approximations of the non-linear power ow equations by minimizing the squared approximation error over a subset of the feasible domain. We test the method using a realistic database for the Chilean system (1548 buses, 1114 lines, 564 transformers). The resulting approximations yield root mean square errors in the order of 0.05pu and are successfully applied to solve a transmission switching instance for the Chilean system. Chapter 3 presents our algorithm for optimal restoration. The algorithm works by partitioning the problem into a master problem and a slave problem. The master problem optimizes over energization sequences of generators, buses and branches, for the entire restoration horizon, while respecting the energization requiments studied in Chapter 1. The slave problem veri es that there exist power ow solutions supporting the energization sequences proposed by the master problem, adding cuts to the master if an infeasible sequence is detected.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY25 Electric Grid Security Annual Report

Sandia’s Electric Grid Security program advances a national vision of energy dominance and accessibility, while applying our national security -emphasis on ensuring of a secure, resilient, and affordable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY25 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Key accomplishments in this report that support our strategy span our technical program areas and include: • New open-source analytical tools for systems -level planning and optimization, including significant advances to the QuESt analytical environment; • Further advancement of artificial intelligence and machine learning to enhanced grid operations and planning as we rise to the challenge of new large loads; • Development of solid-state power conversion technologies and a new medium-voltage research lab; • New technologies to assess wildfire vulnerabilities and mitigate potential impacts; • Advanced applications of new cybersecurity technologies with industry partners; • Contributions to understanding the impacts of electromagnetic pulses and geomagnetic disturbances on grid components; and • Digital twin development for hybrid microgrids with multiple generators, storage, and loads. This report indicates key areas of research and engagement and summarizes the impact of Sandia’s contributions through notable accomplishments, journal publications, patents, and technical conferences and presentations. It is provided with the hope that readers discover ways we can further team to create our modern grid and apply the outcomes of our efforts. The bulk of work described herein is funded by several offices within the U.S. Department of Energy (USDOE), including the Office of Electricity (OE); Cybersecurity, Energy Security, and Emergency Response (CESER); former offices such as the Office of Energy Efficiency and Renewable Energy (EERE), the Grid Deployment Office (GDO), the Office of Clean Energy Demonstrations (OCED), and other key programs at USDOE. As we continue to state in these annual reports, the contributors to our successes are too numerous to name here, though our team wishes to express our deep gratitude to the numerous program and project sponsors at the US Department of Energy, who often function equally as technical collaborators; our many partners in industry, academia, utilities, and other national labs; and fellow researchers and business partners at Sandia whose leadership and creativity have enabled the accomplishments described herein.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Study of Cost-Saving Potential of Load Flexibility Measures in Grid-Interactive Multifamily Buildings

With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.

building energy modeling↗

Coordinated frequency regulation among asynchronous AC grids with an MTDC system

With the increasing penetration level of renewable power, the power systems’ inertias are decreasing. To ensure that the frequency is above the threshold of the under frequency load shedding, one effective way is to share the spinning reserves among asynchronous AC grids through HVDC systems. In this paper, a coordinated frequency regulation scheme that enables spinning reserves sharing is proposed for such hybrid AC/DC grids. This scheme is a communication-free method that consists of the droop control, the inertia emulation control and the frequency safety control. The combined response of the three controls can increase not only the frequency nadir but also the settled frequency of the disturbed grid. In addition, the hysteresis comparators and the power injection limits are adopted in the frequency regulation scheme to reduce the coupling effect among AC grids. Thus, under small and harmless disturbance, the frequency regulation scheme will be inactive; the disturbance in strong AC grids would not affect the weak AC systems. The frequency regulation scheme coordinates well with the automatic generation control of the grids. Furthermore, the feasibility and effectiveness of the proposed frequency regulation scheme are verified through simulation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗