Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Optimized purification methods for metallic contaminant removal from directly recycled Li-ion battery cathodes

Metallic contaminants pose a significant challenge to the viability of directly recycling Li-ion batteries. To date, few strategies exist to selectively remove metallic impurities from mixtures of shredded end-of-life material (black mass; BM) without concurrently damaging the structure and electrochemical performance of the target active material. We herein present tailored methods to selectively ionize two major contaminants—Al and Cu—while retaining a representative cathode (LiNi 0.33 Mn 0.33 Co 0.33 O 2 ; NMC-111) intact. This BM purification process is conducted at moderate temperatures in a KOH-based solution matrix. We rationally evaluate approaches to increase both the kinetic corrosion rate and the thermodynamic solubility of Al 0 and Cu 0 , and evaluate the impact of these treatment conditions on the structure, chemistry, and electrochemical performance of NMC. Specifically, we explore the impacts of chloride-based salts, a strong chelating agent, elevated temperature, and sonication on the rate and extent of contaminant corrosion, while concurrently evaluating the effects on NMC. The reported BM purification process is then demonstrated on samples of “simulated BM” containing a practically relevant 1 wt% concentration of Al or Cu. Increasing the kinetic energy of the purifying solution matrix through elevated temperature and sonication accelerates the corrosion of metallic Al and Cu, such that ∼100% corrosion of 75 μm Al and Cu particles is achieved within 2.5 hr. Further, we determine that effective mass transport of ionized species critically impacts the efficacy of Cu corrosion, and that saturated Cl – hinders rather than accelerates Cu corrosion by increasing solution viscosity and introducing competitive pathways for Cu surface passivation. The purification conditions do not induce bulk structural damage to NMC, and electrochemical capacity is maintained in half-cell format. Testing in full cells suggests that a limited quantity of residual surface species are present after treatment, which initially disrupt electrochemical behavior at the graphite anode but are subsequently consumed. Process demonstration on simulated BM suggests that contaminated samples—which prior to treatment show catastrophic electrochemical performance—can be recovered to pristine electrochemical capacity. The reported BM purification method offers a compelling and commercially viable solution to address contamination, particularly in the “fine” fraction of BM where contaminant sizes are on the same order of magnitude as NMC and where traditional separation approaches are unfeasible. Thus, this optimized BM purification technique offers a pathway towards viable direct recycling of BM feedstocks that would otherwise be unusable.

25 ENERGY STORAGE↗

Coupled Transport, Reactivity, and Mechanics in Fractured Shale Caprocks

Abstract Shales are low‐permeability caprocks that confine fluid, such as CO 2 , nuclear waste, and hydrogen, in storage formations. Stress‐induced fractures in shale caprocks provide pathways for fluid to leak and potentially contaminate fresh water aquifers. Fractured shales are also increasingly considered as resources for CO 2 sequestration, enhanced geothermal, and unconventional energy recovery. Injecting reactive fluids into shales introduces chemical disequilibrium, causing an onset of a series of dissolution, precipitation, and fines mobilization mechanisms. The reactions have rapid kinetics and significant impact on porosity and permeability; consequently, flow and storage properties of caprocks. While previous research has explored the separate effects of these reactions, this study aims to uncover their simultaneous occurrence and collective influence. This study unveils these highly coupled transport and reactivity mechanisms by tracking and visualizing the reaction‐induced alterations in the matrix, microcracks, and fractures of shales over time. We conducted brine injection experiments sequentially at pH 4 and 2 in a naturally fractured Wolfcamp shale sample while simultaneously imaging the dynamic processes using X‐ray computed tomography (CT). CT images are validated by finer resolution images obtained using micro‐CT and scanning electron microscopy. We also tracked the sample permeability and fluid chemistry using brine permeability and inductively coupled plasma mass spectrometry, respectively. Findings show that fluid primarily flowed through fractures, dissolving reactive minerals and mobilizing fines on fracture surfaces. Dissolution of fracture asperities under confining stress resulted in the closing of fractures. Clogging in narrow fracture pathways, caused by fines accumulation, diverted fluid flow into matrix pores.

58 GEOSCIENCES↗

Assumed non-persistent environmental chemicals in human adipose tissue; matrix stability and correlation with levels measured in urine and serum

The aim of this study was to (1) optimize a method for the measurement of parabens and phenols in adipose tissue, (2) evaluate the stability of chemical residues in adipose tissue samples, and (3) study correlations of these compounds in urine, serum, and adipose tissue. Samples were obtained from adults undergoing trauma surgery. Nine phenols and seven parabens were determined by isotope diluted TurboFlow-LC-MS/MS. The analytical method showed good accuracy and precision. Limits of detection (LOD) for parabens and phenols ranged from 0.05 to 1.83 ng/g tissue. Good recovery rates were found, even when biological samples remained defrosted up to 24 h. Benzophenone-3 (BP-3; range of values: 70% of adipose tissue samples, while bisphenol-A (BPA; 40% of adipose tissue samples. In general, levels were similar between adipose tissue and serum, while a correlation between adipose tissue and urine was only found for BP-3. In conclusion, adipose tissue samples in this study were found to contain environmental chemicals considered to be non-persistent, whose levels were weakly or not at all correlated with the urine burden. Therefore, adipose tissue may potentially provide additional information to that obtained from other biological matrices. Further investigations are warranted to explore whether adipose tissue might be a suitable matrix for assessment of the consequences for human health of mid/long-term exposure to these chemicals. - Highlights: • We analyzed levels of endocrine disruptors in adipose tissue, serum and urine. • We found BPA, TCS, BP-3, 2-PP and MeP in >40% of the adipose tissue samples. • Adipose tissue levels of npEDCs did not correlate with those in urine or serum. • Adipose tissue levels may have a different biological meaning.

54 ENVIRONMENTAL SCIENCES↗

Formation of ionic complexes in cryogenic matrices: A case study using co-deposition of Cu{sup −} with rare gas cations in solid argon

Matrix isolation spectra have been obtained for ionic species formed from a beam of mass-selected ions, with a coincident beam of externally generated counter-ions used to provide charge balance. Infrared spectra were obtained for copper carbonyl complexes formed following deposition of Cu{sup −} ions with rare-gas counter-cations into CO-doped argon matrices. Both anionic and neutral copper carbonyl complexes Cu(CO){sub n}{sup q} (n = 1–3; q = 0, −1) were observed in the spectra, with peak positions corresponding to previously reported assignments; new partially resolved bands appearing in the range 1830–1845 cm{sup −1} are assigned to larger [Cu(CO){sub 3}•(CO){sub n}]{sup −} aggregates, having additional CO ligands in the second solvation shell. The experimental geometry ensures that all Cu-centers initially arrive at the matrix as anions, so the relative abundance of anionic relative to neutral complexes is much higher than in previous studies employing alternative methods for ion deposition; this allows for monitoring of electron-transfer processes between anions and cations in the matrix. Comparison of time-dependent vs. temperature-dependent trends reveals that there are two distinct mechanisms by which the population of anionic complexes is converted into neutral complexes: short-range electron transfer between a cation-anion pair following diffusion, and long-range electron transfer involving photodetachment of an electron from the anion into the conduction band of solid argon, resulting in eventual recombination of the electron with a cation in a remote matrix site. The spectra also show a marked dependence on the deposition temperature and dopant concentration, in that 100-fold higher CO concentrations were required during deposition with the sample window at 10 K compared to that used at 20 K, in order to obtain a similar distribution of copper carbonyl complexes. Furthermore, although no carbonyl complexes are observed initially when low concentrations of CO are used at 10 K, upon warming the matrix to 15 K, the neutral di- and tricarbonyl peaks appear abruptly, which is attributed to fast diffusion of CO stimulated by the energy released upon short-range electron-transfer between Cu{sup −}:counter-cation pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient many-jet event generation with flow matching

We apply for the first time, to the best of our knowledge, the flow matching method to the problem of phase-space sampling for event generation in high-energy collider physics. By training the model to remap the random numbers used to generate the momenta and helicities of the scattering matrix elements as implemented in the portable partonic event generator pepper, we find substantial efficiency improvements in the studied processes. We focus our study on the highest final-state multiplicities in Drell-Yan and top-antitop pair production used in simulated samples for the Large Hadron Collider, which computationally are the most relevant ones. We find that the unweighting efficiencies improve by factors of 184 and 25, respectively, when compared to the standard approach of using a vegas-based optimization. We also compare continuous normalizing flows trained with flow matching against the previously studied normalizing flows based on coupling layers and find that the former leads to better results, faster training and a better scaling behavior across the studied multiplicity range, while the latter evaluate faster. When combining the advantages of both methods using the regflow approach, we find parton-level unweighted event generation walltime gains of about a factor of 10 at the highest final-state multiplicities.

Bothmann, E. [CERN; Gottingen U.] (ORCID:000000016↗

XRD studies of cement embedding matrices containing complexing reagents from decontamination practices

The study of embedding matrix of radioactive waste is an important issue concerning the need to assure the radiological safety requirements for final disposal. The conditioning of the radioactive wastes by cementation process involves also a structural investigation by X-ray diffraction (XRD) of the samples prepared with cement and complexing agents at different concentration. This paper gives useful information about the influence of complexing agents related to damages produced in concrete microstructures. The experimental data obtained on samples kept in real repository environment for a period up to 15 years, offer structural information regarding the interaction between the different decontamination agents with the major components of the matrix. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory Experiments to Evaluate Matrix Diffusion of Dissolved Organic Carbon Carbon-14 in Southern Nevada Fractured-rock Aquifers

Dissolved inorganic carbon (DIC) carbon-14 ( 14 C) is used to estimate groundwater ages by comparing the DIC 14 C content in groundwater in the recharge area to the DIC 14 C content in the downgradient sampling point. However, because of chemical reactions and physical processes between groundwater and aquifer rocks, the amount of DIC 14 C in groundwater can change and result in 14 C loss that is not because of radioactive decay. This loss of DIC 14 C results in groundwater ages that are older than the actual groundwater ages. Alternatively, dissolved organic carbon (DOC) 14 C in groundwater does not react chemically with aquifer rocks, so DOC 14 C ages are generally younger than DIC 14 C ages. In addition to chemical reactions, 14 C ages may also be altered by the physical process of matrix diffusion. The net effect of a continuous loss of 14 C to the aquifer matrix by matrix diffusion and then radioactive decay is that groundwater appears to be older than it actually is. Laboratory experiments were conducted to measure matrix diffusion coefficients for DOC 14 C in volcanic and carbonate aquifer rocks from southern Nevada. Experiments were conducted using bromide (Br-) as a conservative tracer and 14 C-labeled trimesic acid (TMA) as a surrogate for groundwater DOC. Outcrop samples from six volcanic aquifers and five carbonate aquifers in southern Nevada were used. The average DOC 14 C matrix diffusion coefficient for volcanic rocks was 2.9 x 10 -7 cm 2 /s, whereas the average for carbonate rocks was approximately the same at 1.7 x 10 -7 cm 2 /s. The average Br- matrix diffusion coefficient for volcanic rocks was 10.4 x 10 -7 cm 2 /s, whereas the average for carbonate rocks was less at 6.5 x 10 -7 cm 2 /s. Carbonate rocks exhibited greater variability in DOC 14 C and Br- matrix diffusion coefficients than volcanic rocks. These results confirmed, at the laboratory scale, that the diffusion of DOC 14 C into southern Nevada volcanic and carbonate aquifers is slower than DIC 14 C. Because of the apparent sorption of 14 C-labeled TMA in the experiments, matrix diffusion coefficients are likely even lower. The reasons for the higher than expected Br-/ 14 C-labeled TMA are unknown. Because the molecular size of TMA is on the low end of the range in molecular size for typical humic substances, the matrix diffusion coefficients for the 14 C-labeled TMA likely represent close to the maximum diffusion rates for DOC 14 C in the volcanic and carbonate aquifers in southern Nevada.

54 ENVIRONMENTAL SCIENCES↗

Matrix-Assisted Ionization of Molecular Uranium Species

Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Constructing mutually unbiased bases in dimension six

The density matrix of a qudit may be reconstructed with optimal efficiency if the expectation values of a specific set of observables are known. In dimension six, the required observables only exist if it is possible to identify six mutually unbiased complex (6x6) Hadamard matrices. Prescribing a first Hadamard matrix, we construct all others mutually unbiased to it, using algebraic computations performed by a computer program. We repeat this calculation many times, sampling all known complex Hadamard matrices, and we never find more than two that are mutually unbiased. This result adds considerable support to the conjecture that no seven mutually unbiased bases exist in dimension six.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

Ambient Mass Spectrometry Imaging Using Direct Liquid Extraction Techniques

Mass spectrometry imaging (MSI) is a powerful analytical technique that enables label-free spatial localization and identification of molecules in complex samples.1-4 MSI applications range from forensics5 to clinical research6 and from understanding microbial communication7-8 to imaging biomolecules in tissues.1, 9-10 Recently, MSI protocols have been reviewed.11 Ambient ionization techniques enable direct analysis of complex samples under atmospheric pressure without special sample pretreatment.3, 12-16 In fact, in ambient ionization mass spectrometry, sample processing (e.g., extraction, dilution, preconcentration, or desorption) occurs during the analysis.17 This substantially speeds up analysis and eliminates any possible effects of sample preparation on the localization of molecules in the sample.3, 8, 12-14, 18-20 Venter and co-workers have classified ambient ionization techniques into three major categories based on the sample processing steps involved: 1) liquid extraction techniques, in which analyte molecules are removed from the sample and extracted into a solvent prior to ionization; 2) desorption techniques capable of generating free ions directly from substrates; and 3) desorption techniques that produce larger particles subsequently captured by an electrospray plume and ionized.17 This review focuses on localized analysis and ambient imaging of complex samples using a subset of ambient ionization methods broadly defined as “liquid extraction techniques” based on the classification introduced by Venter and co-workers.17 Specifically, we include techniques where analyte molecules are desorbed from solid or liquid samples using charged droplet bombardment, liquid extraction, physisorption, chemisorption, mechanical force, laser ablation, or laser capture microdissection. Analyte extraction is followed by soft ionization that generates ions corresponding to intact species. Some of the key advantages of liquid extraction techniques include the ease of operation, ability to analyze samples in their native environments, speed of analysis, and ability to tune the extraction solvent composition to a problem at hand. For example, solvent composition may be optimized for efficient extraction of different classes of analytes from the sample or for quantification or online derivatization through reactive analysis. In this review, we will: 1) introduce individual liquid extraction techniques capable of localized analysis and imaging, 2) describe approaches for quantitative MSI experiments free of matrix effects, 3) discuss advantages of reactive analysis for MSI experiments, and 4) highlight selected applications (published between 2012 and 2015) that focus on imaging and spatial profiling of molecules in complex biological and environmental samples.

Environmental Molecular Sciences Laboratory↗

Unbiased reduced density matrices and electronic properties from full configuration interaction quantum Monte Carlo

Properties that are necessarily formulated within pure (symmetric) expectation values are difficult to calculate for projector quantum Monte Carlo approaches, but are critical in order to compute many of the important observable properties of electronic systems. Here, we investigate an approach for the sampling of unbiased reduced density matrices within the full configuration interaction quantum Monte Carlo dynamic, which requires only small computational overheads. This is achieved via an independent replica population of walkers in the dynamic, sampled alongside the original population. The resulting reduced density matrices are free from systematic error (beyond those present via constraints on the dynamic itself) and can be used to compute a variety of expectation values and properties, with rapid convergence to an exact limit. A quasi-variational energy estimate derived from these density matrices is proposed as an accurate alternative to the projected estimator for multiconfigurational wavefunctions, while its variational property could potentially lend itself to accurate extrapolation approaches in larger systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative Morphological Characterization of Carbide Inclusions in Uranium Metal

Uranium carbides (UCs) are prevalent inclusions in U metal that form during melting operations from interactions with crucible walls and the casting chamber atmosphere. Although UCs have been studied extensively since the beginning of U metal foundry operations, there are still unknowns regarding the effects of thermomechanical processing on their sizes and morphology. Here, we present the results of a series of controlled cooling experiments with molten uranium to elucidate the effect of cooling rate on inclusion morphology in a-U. Samples were melted using a vacuum induction melter and manually cooled at rates of 2.5, 1.7, 1.1, 0.8, 0.3 (± 1%) K/s from ~1600 K to <700 K in under 1 hour. Subsequent scanning electron microscopy (SEM) was performed on cross-sections of the samples, revealing a complex mixture of UC morphologies that are indicative of diffusion and growth influenced by the thermal processing of the U matrix. Image analysis using the Morphological Analysis of Materials (MAMA) software showed that UC sizes generally grew larger with slower cooling rates, and the two slowest cooling rates noticeably impacted the inclusion circularity and ellipse aspect ratio. These results indicate that UC morphology is sensitive to short cooling rates (<1 hour) and could therefore be controlled in the production of metallic nuclear fuels. Additionally, inclusion speciation and morphologies could potentially provide forensic clues about processing history of unknown metal samples. Understanding the driving forces involved in UC morphology evolution is beneficial for evaluating metal fuels for next generation nuclear reactors and for identifying signatures for nuclear forensics.

Athon, Matthew T.↗

The International Framework for Maintaining Equivalence and Traceability in Radionuclide Metrology

Confidence that a testing or calibration laboratory consistently obtains reliable results is of major importance to users of laboratory services and participation in proficiency testing schemes provides laboratories with an objective means of assessing and demonstrating the level of confidence that can be ascribed to the reliability of the data they are producing. That level of confidence, in turn, depends on the quality of the proficiency tests and, in particular, on the accuracy of the property values associated with the test samples. In the ideal situation, the relevant property value, such as the activity of a particular radionuclide in a test matrix, will be directly traceable to the SI via comparisons with a national or international metrology institute (NMI). This, in turn, begs the question of, how reliable are the results from that NMI.Demonstration of that reliability at the highest metrological levels is achieved through inter-laboratory comparisons that are conducted between national and international metrological institutes. These are coordinated primarily by the Bureau International des Poids et Mesures (BIPM) via Key Comparisons or by comparisons within Regional Metrological Organisations (RMOs), with the results from those RMO exercises being linked to the BIPM Key Comparison results. Such programmes have been in place for many years but they have grown in importance and frequency over the past decade. Tabulation of these comparison data has been regularized recently and made available to the user communities via the BIPM Key Comparison Database (KCDB).In the field of ionizing radiation, the radionuclide metrology discipline exhibits a number of special features. For example, these include the number of potential radionuclides in a user sample; the variety of physical and chemical formats that may be presented; the statistical and temporal effects of radioactive decay; the variations in primary standardization techniques; and the restricted applicability of those primary standardization techniques to the full range of potential radionuclides and activities. Each of these, singly or in combination, ensure that there can never be a fully comprehensive set of Key Comparisons which will cover the requirements of the user community and, in turn, compromise the ability to provide a full range of proficiency tests for testing and calibration laboratories.These problems are discussed, in the context of radioactivity measurements, together with the structure and range of Key Comparisons and associated databases at the highest international level that are currently in place to underpin the proficiency tests that are necessary for the user communities in this field of application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ELASTOMERIC MICROVASCULAR SELF-HEALING MATERIALS

Damaged elastomeric diaphragms within pneumatic controllers used in the oil and gas industry lead to an unintended release of methane. Self-healing microvascular materials capable of healing various types of damage have been fabricated. These microvascular materials are designed to replace currently available commercial diaphragms found in pneumatic controllers and provide a solution to reduce unintended methane leaks. Poly(dimethylsiloxane) (PDMS) was used as the main matrix material, with additional testing conducted on polyurethane and flexibilised epoxy materials. Microvascular networks were implemented into the elastomeric membranes to act as ves- sels to deliver healing agents to the damaged areas. The complex, interdigitated channel networks were created using a 3D printed custom compounded filament composed of polylactic acid (PLA) and tin(II) oxalate. Two-part liquid casting polymers were poured around the channels into a mould to create samples with the scaffolding of the microvascular channels intact. Hollow microvascular networks were created by placing the samples within a vacuum oven at 250◦C which causes the thermal depolymerisation of PLA into its gaseous monomers. The manufactured materials were placed in test stands and pressurized using nitrogen gas to determine their healing and mechanical behaviour. Self-healing behaviour was demonstrated using PDMS matrix materials and healing chemistries within a pressure test cell. This test cell was designed to detect any damage to a sample by record- ing an outlet pressure. Damages including puncture holes, diagonal cuts and star-shaped central iv cuts were applied to the samples and a reduction in the outlet pressure was recorded for all sam- ples. A variation in channel spacing and diameter was studied to determine the optimal design of the microvascular network for self-healing performance. The mechanical performance of elastomeric membrane materials within a diaphragmatic pressurised stand was observed. Deformations and strains around the channels and channel inter- sections at the midplane of the materials were recorded using digital image correlation. Normal stresses were calculated using Hooke’s law and the material properties of the PDMS matrix. A reduction in leak rate, implying the success of self-healing, was recorded within manu- factured diaphragm samples tested within a commercial valve. PDMS is the favourable material when compared to polyurethane and flexibilised epoxy for creating

03 NATURAL GAS↗

Simultaneous isotopic analysis of fission product Sr, Mo, and Ru in spent nuclear fuel particles by resonance ionization mass spectrometry

Abstract Fission product Sr, Mo, and Ru isotopes in six 10-μm particles of spent fuel from a pressurized water reactor were analyzed by resonance ionization mass spectrometry (RIMS) and evaluated for utility in nuclear material characterization. Previous measurements on these same samples showed widely varying U, Pu, and Am isotopic compositions owing to the samples’ differing irradiation environments within the reactor. This is also seen in Mo and Ru isotopes, which have the added complication of exsolution from the UO 2 fuel matrix. This variability is a hindrance to interpreting data from a collection of particles with incomplete provenance since it is not always possible to assign particles to the same batch of fuel based on isotopic analyses alone. In contrast, the measured 90 Sr/ 88 Sr ratios were indistinguishable across all samples. Strontium isotopic analysis can therefore be used to connect samples with otherwise disparate isotopic compositions, allowing them to be grouped appropriately for interpretation. Strontium isotopic analysis also provides a robust chronometer for determining the time since fuel irradiation. Because of the very high sensitivity of RIMS, only a small fraction of material in each of the 10 μm samples was consumed, leaving the vast majority still available for other analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preferred Void Orientation in Uniaxially Pressed PBX 9502

Ultra- and small-angle neutron scattering techniques were used to study the morphology of voids in directions parallel and perpendicular to the compaction plane of a uniaxially pressed cylinder of PBX 9502. Two-dimensional scattering patterns from samples cut parallel to the compaction plane had circular equal-intensity contours, implying that along this view the voids are circular or randomly oriented. Identical measurements of samples cut perpendicular to the compaction plane produced elliptical equal-intensity contours, indicating preferred orientation of voids. Analysis of the two dimensional scattering patterns confirmed that the voids are non-spherical with an average aspect ratio of 1.20, flattened so that the larger dimensions of the voids lie within the compaction plane. Model analysis of the combined ultra- and small-angle neutron scattering curves revealed that the PBX 9502 porosity is interconnected, in the form of aggregates comprised of non-spherical, primary voids. The volume dimension was found to be the same in both directions, indicating that the aggregate is randomly oriented throughout the sample, and that it is the primary voids that are preferentially oriented. Furthermore, void interfaces with the surrounding matrix were found to be rough or polydisperse, with a common roughness dimension or polydispersity in all directions.

42 ENGINEERING↗

Microstructure and Interfacial Shear Strength in W/(Zr{sub 55}Cu{sub 30}Al{sub 10}Ni{sub 5}){sub 100−x}Nb{sub x} Composites

In the present study, (Zr{sub 55}Cu{sub 30}Al{sub 10}Ni{sub 5}){sub 100−x}Nb{sub (x=0,1,2,3)} bulk metallic glass matrix/tungsten wire composites were fabricated by a gas pressure infiltration process at temperature 950 °C for 5 min. Microstructural studies and mechanical behaviors of the materials have been investigated by scanning electron microscopy, transmission electron microscopy and pullout tests. The mechanical results showed that the interface shear strength in the composite sample with X = 2 increased more than twice compared to the composite sample with X = 0. Based on the microstructural results, the addition of two atomic percent Nb in the matrix composite causes an increase in the diffusion band thickness during the melt infiltration and change in the interface fracture mode as a result of pullout test.

36 MATERIALS SCIENCE↗