Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple scattering effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Use of Multipass Recirculation and Energy Recovery In CW SRF X-FEL Driver Accelerators

We discuss the use of multipass recirculation and energy recovery in CW SRF drivers for short wavelength FELs. Benefits include cost management (through reduced system footprint, required RF and SRF hardware, and associated infrastructure - including high power beam dumps and cryogenic systems), ease in radiation control (low drive beam exhaust energy), ability to accelerate and deliver multiple beams of differing energy to multiple FELs, and opportunity for seamless integration of multistage bunch length compression into the longitudinal matching scenario. Issues include all those associated with ERLs compounded by the challenge of generating and preserving the CW electron drive beam brightness required by short wavelength FELs. We thus consider the impact of space charge, BBU and other environmental wakes and impedances, ISR and CSR, potential for microbunching, intra-beam and beam-residual gas scattering, ion effects, RF transients, and halo, as well as the effect of traditional design, fabrication, installation and operational errors (lattice aberrations, alignment, powering, field quality). Context for the discussion is provided by JLAMP, the proposed VUV/X-ray upgrade to the existing Jefferson Lab FEL.

43 PARTICLE ACCELERATORS↗

Spectator Proton Detection and Reconstruction in Deep Inelastic D(E,EPS) Scattering

A Radial Time Projection Chamber (RTPC) was designed and installed in Jefferson Lab's Hall B as part of the BONuS12 (Barely Off-shell Nucleon Structure) experiment. The goal of BONuS12 is to accurately measure the structure function of the neutron by scattering 11 GeV electrons and detecting them with the CLAS12 spectrometer. Deuterium gas was used as an effective neutron target, and the new RTPC was used to detect low momentum spectator protons. Protons follow a curved path in the 5 Tesla solenoid that is part of CLAS12, ionizing the He-CO2 gas in an annular drift region surrounding the target. These ionization electrons are radially drifted outwards, amplified using cylindrical GEM (Gaseous Electron Multiplication) foils and recorded using readout pads located along the entire outer face of the cylindrical detector. The particle track reconstruction software discussed in detail in this thesis uses the signals from these pads to build tracks, which are reconstructed into the drift region using the arrival times of the signals and the positions of the pads. The proton momentum is measured from the track?s curvature and thus used to extract information about the struck neutron. This thesis introduces the theory of spectator tagging as an effective strategy for measuring neutron structure, by minimizing nuclear effects in the absence of a free neutron target. Along with discussing the many detectors that make up the CLAS12 spectrometer, the RTPC will be covered in detail, along with the tracking software designed to interpret the electronic signals to rebuild the low-momentum particle tracks, and fit them to extract the relevant kinematics. The results of the software, and preliminary analysis will be shown in the final chapter, as well as the discussion of possible improvements which could be made to the tracking software.

Payette, David↗

SU-E-T-110: Development of An Independent, Monte Carlo, Dose Calculation, Quality Assurance Tool for Clinical Trials

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Purpose: To commission a multiple-source Monte Carlo model of Elekta linear accelerator beams of nominal energies 6MV and 10MV. Methods: A three source, Monte Carlo model of Elekta 6 and 10MV therapeutic x-ray beams was developed. Energy spectra of two photon sources corresponding to primary photons created in the target and scattered photons originating in the linear accelerator head were determined by an optimization process that fit the relative fluence of 0.25 MeV energy bins to the product of Fatigue-Life and Fermi functions to match calculated percent depth dose (PDD) data with that measured in a water tank for a 10x10cm2 field. Off-axis effects were modeled by a 3rd degree polynomial used to describe the off-axis half-value layer as a function of off-axis angle and fitting the off-axis fluence to a piecewise linear function to match calculated dose profiles with measured dose profiles for a 40×40cm2 field. The model was validated by comparing calculated PDDs and dose profiles for field sizes ranging from 3×3cm2 to 30×30cm2 to those obtained from measurements. A benchmarking study compared calculated data to measurements for IMRT plans delivered to anthropomorphic phantoms. Results: Along the central axis of the beam 99.6% and 99.7% of all data passed the 2%/2mm gamma criterion for 6 and 10MV models, respectively. Dose profiles at depths of dmax, through 25cm agreed with measured data for 99.4% and 99.6% of data tested for 6 and 10MV models, respectively. A comparison of calculated dose to film measurement in a head and neck phantom showed an average of 85.3% and 90.5% of pixels passing a 3%/2mm gamma criterion for 6 and 10MV models respectively. Conclusion: A Monte Carlo multiple-source model for Elekta 6 and 10MV therapeutic x-ray beams has been developed as a quality assurance tool for clinical trials.

60 APPLIED LIFE SCIENCES↗

Retrievals of Aerosol and Cloud Particle Microphysics Using Polarization and Depolarization Techniques

The recent availability of theoretical techniques for computing single and multiple scattering of light by realistic polydispersions of spherical and nonspherical particles and the strong dependence of the Stokes scattering matrix on particle size, shape, and refractive index make polarization and depolarization measurements a powerful particle characterization tool. In this presentation I will describe recent applications of photopolarimetric and lidar depolarization measurements to remote sensing characterization of tropospheric aerosols, polar stratospheric clouds (PSCs), and contrails. The talk will include (1) a short theoretical overview of the effects of particle microphysics on particle single-scattering characteristics; (2) the use of multi-angle multi-spectral photopolarimetry to retrieve the optical thickness, size distribution, refractive index, and number concentration of tropospheric aerosols over the ocean surface; and (3) the application of the T-matrix method to constraining the PSC and contrail particle microphysics using multi-spectral measurements of lidar backscatter and depolarization.

Mishchenko, Michael↗

Probing late-stage hadronic interactions at high baryon density via $K^{⁎0}$ production in the RHIC beam energy scan program

A precision measurement of the $K^{⁎0}$ meson yield is reported in Au+Au collisions at $\sqrt{s_{NN}}$ = 7.7, 11.5, 14.6, 19.6, and 27 GeV using the high-statistics data sample collected by the STAR experiment during the Beam Energy Scan II (BES-II) program at RHIC. The transeverse momentum (p T )-integrated yield ratios $\large{(}K^{⁎0} + \overline{K^{⁎0}}\large{)}/(K^+ + K^{-})$ in central collisions show a suppression relative to peripheral collisions at the (1.7–3.6) σ level, while a thermal model without final-stage rescattering overpredicts this ratio with a deviation of (6.9–8.2) σ. These results indicate a loss of the measured $K^{⁎0}$ signal in central collisions due to re-scattering of its hadronic decay products in the hadronic phase. The p T -integrated yield of charged kaons exhibits an approximate scaling with charged-particle multiplicity, independent of collision energy and system size. A similar trend is observed for the short-lived $K^{⁎0}$ resonance, although significant deviations emerge at lower energies. At BES energies, the $K^{⁎0}/K$ ratio shows stronger suppression than at the highest RHIC and LHC energies within a given multiplicity bin, particularly in central and mid-central collisions. This behavior is consistent with changes in the effective hadronic interaction cross section and is supported by transport model calculations, which indicate dominant meson–baryon interactions at lower energies and meson–meson interactions at higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interaction of 0.53 {mu}m laser pulse with millimeter-scale plasmas generated by gasbag target

Detailed research on the interaction of a 0.53 {mu}m laser pulse with millimeter-scale plasmas produced by a gasbag target on the Shengguang-II facility is presented. The x-ray pinhole images confirm that millimeter-scale plasmas are generated and the x-ray framing images show a temporal window of 0.6-1.1 ns during which the millimeter-scale plasmas exist. The electron temperature is measured with a collective Thomson scattering system, providing 0.64 keV for C{sub 5}H{sub 12} and 1.8 keV for Xe plasmas. The electron density is inferred from the stimulated Raman scattering spectra. The experimental spectra show large differences for C{sub 5}H{sub 12}- and Xe-filled gasbags. A one-dimensional code based upon steady-state, kinetic linear theory is applied to calculate the stimulated Raman scattering spectra. Excellent agreement between the calculated and experimental results shows that the plasma parameters, especially the electron density and the temperature, dominate the disruption behavior of stimulated Raman scattering. The results also indicate that stimulated Raman scattering is probably located within specific region of the gasbag. The time-integrated reflectivity of both the stimulated Raman and Brillouin scattering is at a low level, even in the conditions of high laser intensity (1.5 Multiplication-Sign 10{sup 15} W/cm{sup 2}) and no beam-smoothing. The experimental results are promising for future ignition experiments with a 0.53 {mu}m laser as the driver.

2-METHYLBUTANE↗

Effect of Polymer Chain Length on the Superlattice Assembly of Functionalized Gold Nanoparticles

We report on the assembly of gold nanoparticle (AuNPs) superlattices at the liquid/vapor interface and in the bulk of their suspensions. Interparticle distances in the assemblies are achieved on multiple length scales by varying chain lengths of surface grafted AuNPs by polyethylene glycol (PEG) with molecular weights in the range 2000–40,000 Da. Crystal structures and lattice constants in both 2D and 3D assemblies are determined by synchrotron-based surface-sensitive and small-angle X-ray scattering. Here, assuming knowledge of grafting density, we show that experimentally determined interparticle distances are adequately modeled by spherical brushes close to the θ point (Flory–Huggins parameter, x ≈ 1/2) for 2D superlattices at a liquid interface and a nonsolvent (χ = ∞) for the 3D dry superlattices.

36 MATERIALS SCIENCE↗

Iterative stability analysis of spatial domain decomposition based on block Jacobi algorithm for the diamond-difference scheme

Here, we study convergence of the integral transport matrix method (ITMM) based on a parallel block Jacobi (PBJ) iterative strategy for solving particle transport problems. The ITMM is a spatial domain decomposition method proposed for massively parallel computations. AFourier analysis of the PBJ-based iterations applied to SN diamond-difference equations in 1D slab and 2D Cartesian geometries is performed. It is carried out for infinite-medium problems with homogeneous material properties. To analyze the performance of the ITMM with the PBJ algorithm and evaluate its potential in scalability we consider a limiting case of one spatial cell per subdomain. The analysis shows that in such limit the spectral radius of the iteration method is one without regard to values of the scattering ratio and optical thickness of the spatial cells. This implies lack of convergence in infinite medium. Numerical results of finite-medium problems are presented. They demonstrate effects of finite size of spatial domain on the performance of the iteration algorithm as well as its asymptotic behavior when the extent of the spatial domain increases. Finally, these numerical experiments also show that for finite domains iterative convergence to a finite criterion is achievable in a multiple of the sum of number of cells in each dimension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gluon polarization in the nucleon

Gluons can contribute to the nucleon spin and may provide the part missing when only quark spins are taken into account. The gluon helicity distribution can be obtained from QCD fits or from direct measurements in experiments selecting processes sensitive to gluons. Recently several important measurements were completed and others are in progress in fixed target lepton nucleon scattering as well as in collider experiments with polarized protons. Asymmetries are obtained in processes with significant contributions from gluons such as in lepton nucleon scattering the production of D mesons and production of hadrons with high transverse momentum, and in polarized pp scattering the production of jets, {pi}{sup 0} mesons and direct photons. These results are interpreted in terms of universal gluon helicity distribution, using assumptions and approximations specific for each analysis. The complementarity of the approaches is very important in controlling systematic effects and in establishing the present conclusion and interpretation that the data show no signature of very high gluon polarization in the kinematic region of observations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interwoven atypical quantum states in CeLiBi 2

Here we report the discovery of CeLiBi 2 , the first example of a material in the tetragonal CeTX 2 ( T = transition metal; X = pnictogen) family wherein an alkali cation replaces the typical transition metal. Magnetic susceptibility and neutron powder diffraction measurements are consistent with a crystal-field Γ 6 ground-state Kramers doublet that orders antiferromagnetically below T N = 3.4 K with an incommensurate propagation wave vector k = ( 0, 0.0724(4), 0.5) that generates a nanometric modulation of the magnetic structure. The best model of the ordered state is an elliptical cycloid with Ce moments primarily residing in the ab plane. This is highly unusual, as all other Γ 6 CeTX 2 members order ferromagnetically. Further, we observe an atypical hard-axis metamagnetic transition at 2 T in magnetostriction, magnetization, and resistivity measurements. CeLiBi 2 is a rare example of a highly conductive material with dominant skew scattering leading to a large anomalous Hall effect. Quantum oscillations with five frequencies arise in magnetostriction and magnetic susceptibility data to T = 30 K and μ 0 H = 55 T, which indicate small Fermi pockets of light carriers with effective masses as low as 0.07 m e . Density functional theory calculations indicate that square-net Dirac-like Bi-p bands are responsible for these ultralight carriers. Together, our results show that CeLiBi 2 enables multiple atypical magnetic and electronic properties in a single clean material.

36 MATERIALS SCIENCE↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle

Purpose: The purposes of this study were to validate a discrete spot scanning proton beam nozzle using the Monte Carlo (MC) code MCNPX and use the MC validated model to investigate the effects of a low-dose envelope, which surrounds the beam's central axis, on measurements of integral depth dose (IDD) profiles. Methods: An accurate model of the discrete spot scanning beam nozzle from The University of Texas M. D. Anderson Cancer Center (Houston, Texas) was developed on the basis of blueprints provided by the manufacturer of the nozzle. The authors performed simulations of single proton pencil beams of various energies using the standard multiple Coulomb scattering (MCS) algorithm within the MCNPX source code and a new MCS algorithm, which was implemented in the MCNPX source code. The MC models were validated by comparing calculated in-air and in-water lateral profiles and percentage depth dose profiles for single pencil beams with their corresponding measured values. The models were then further tested by comparing the calculated and measured three-dimensional (3-D) dose distributions. Finally, an IDD profile was calculated with different scoring radii to determine the limitations on the use of commercially available plane-parallel ionization chambers to measure IDD. Results: The distance to agreement, defined as the distance between the nearest positions of two equivalent distributions with the same value of dose, between measured and simulated ranges was within 0.13 cm for both MCS algorithms. For low and intermediate pencil beam energies, the MC simulations using the standard MCS algorithm were in better agreement with measurements. Conversely, the new MCS algorithm produced better results for high-energy single pencil beams. The IDD profile calculated with cylindrical tallies with an area equivalent to the area of the largest commercially available ionization chamber showed up to 7.8% underestimation of the integral dose in certain depths of the IDD profile. Conclusions: The authors conclude that a combination of MCS algorithms is required to accurately reproduce experimental data of single pencil beams and 3-D dose distributions for the scanning beam nozzle. In addition, the MC simulations showed that because of the low-dose envelope, ionization chambers with radii as large as 4.08 cm are insufficient to accurately measure IDD profiles for a 221.8 MeV pencil beam in the scanning beam nozzle.

60 APPLIED LIFE SCIENCES↗

High-speed digitization readout of silicon photomultipliers for time of flight positron emission tomography

We report on work to develop a system with about 100 picoseconds (ps) time resolution for time of flight positron emission tomography [TOF-PET]. The chosen photo detectors for the study were Silicon Photomultipliers (SiPM's). This study was based on extensive experience in studying timing properties of SiPM's. The readout of these devices used the commercial high speed digitizer DRS4. We applied different algorithms to get the best time resolution of 155 ps Guassian (sigma) for a LYSO crystal coupled to a SiPM. We consider the work as a first step in building a prototype TOF-PET module. The field of positron-emission-tomography (PET) has been rapidly developing. But there are significant limitations in how well current PET scanners can reconstruct images, related to how fast data can be acquired, how much volume they can image, and the spatial and temporal resolution of the generated photons. Typical modern scanners now include multiple rings of detectors, which can image a large volume of the patient. In this type of scanner, one can treat each ring as a separate detector and require coincidences only within the ring, or treat the entire region viewed by the scanner as a single 3 dimensional volume. This 3d technique has significantly better sensitivity since more photon pair trajectories are accepted. However, the scattering of photons within the volume of the patient, and the effect of random coincidences limits the technique. The advent of sub-nanosecond timing resolution detectors means that there is potentially much better rejection of scattered photon events and random coincidence events in the 3D technique. In addition, if the timing is good enough, then the origin of photons pairs can be determined better, resulting in improved spatial resolution - so called 'Time-of-Flight' PET, or TOF-PET. Currently a lot of activity has occurred in applications of SiPMs for TOF-PET. This is due to the devices very good time resolution, low profile, lack of high voltage needed, and their non-sensitivity to magnetic fields. While investigations into this technique have begun elsewhere, we feel that the extensive SiPM characterization and data acquisition expertise of Fermilab, and the historical in-depth research of PET imaging at University of Chicago will combine to make significant strides in this field. We also benefit by a working relationship with the SiPM producer STMicroelectronics (STM).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contributions of anharmonic phonon interactions to thermal boundary conductance.

Continued reduction of characteristic dimensions in nanosystems has given rise to increasing importance of material interfaces on the overall system performance. With regard to thermal transport, this increases the need for a better fundamental understanding of the processes affecting interfacial thermal transport, as characterized by the thermal boundary conductance. When thermal boundary conductance is driven by phononic scattering events, accurate predictions of interfacial transport must account for anharmonic phononic coupling as this affects the thermal transmission. In this paper, a new model for phononic thermal boundary conductance is developed that takes into account anharonic coupling, or inelastic scattering events, at the interface between two materials. Previous models for thermal boundary conductance are first reviewed, including the Diffuse Mismatch Model, which only consdiers elastic phonon scattering events, and earlier attempts to account for inelastic phonon scattering, namely, the Maximum Transmission Model and the Higher Harmonic Inelastic model. A new model is derived, the Anharmonic Inelastic Model, which provides a more physical consideration of the effects of inelastic scattering on thermal boundary conductance. This is accomplished by considering specific ranges of phonon frequency interactions and phonon number density conservation. Thus, this model considers the contributions of anharmonic, inelastically scattered phonons to thermal boundary conductance. This new Anharmonic Inelastic Model shows excellent agreement between model predictions and experimental data at the Pb/diamond interface due to its ability to account for the temperature dependent changing phonon population in diamond, which can couple anharmonically with multiple phonons in Pb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of a coherent soft x-ray beamline for coherent scattering experiments at NSLS-II

The coherent soft x-ray and full polarization control (CSX) beamline at the National Synchrotron Light Source - II (NSLS-II) will deliver 1013 coherent photons per second in the energy range of 0.2-2 keV with a resolving power of 2000. The source, a dual elliptically polarizing undulator (EPU), and beamline optics should be optimized to deliver the highest possible coherent flux in a 10-30 {micro}m spot for use in coherent scattering experiments. Using the computer code Synchrotron Radiation Workshop (SRW), we simulate the photon source and focusing optics in order to investigate the conditions which provide the highest usable coherent intensity on the sample. In particular, we find that an intermediate phasing magnet is needed to correct for the relative phase between the two EPUs and that the optimum phase setting produces a spectrum in which the desired wavelength is slightly red-shifted thus requiring a larger aperture than originally anticipated. This setting is distinct from that which produces an on-axis spectrum similar to a single long undulator. Furthermore, partial coherence calculations, utilizing a multiple electron approach, indicate that a high degree of spatial coherence is still obtained at the sample location when such an aperture is used. The aperture size which maximizes the signal-to-noise ratio of a double-slit experiment is explored. This combination of high coherence and intensity is ideally suited for x-ray ptychography experiments which reconstruct the scattering density from micro-diffraction patterns. This technique is briefly reviewed and the effects on the image quality of proximity to the beamline focus are explored.

36 MATERIALS SCIENCE↗

Multiple origins of extra electron diffractions in fcc metals

Diffuse intensities in the electron diffraction patterns of concentrated face-centered cubic solid solutions have been widely attributed to chemical short-range order, although this connection has been recently questioned. This article explores the many nonordering origins of commonly reported features using a combination of experimental electron microscopy and multislice diffraction simulations, which suggest that diffuse intensities largely represent thermal and static displacement scattering. A number of observations may reflect additional contributions from planar defects, surface terminations incommensurate with bulk periodicity, or weaker dynamical effects.

36 MATERIALS SCIENCE↗

Strong-field Gravitational Effects in the Timing and Spectroscopy of X-Ray Binaries

Using the ray-tracing code described, we developed additional features to the hot spot model to explain the broadening of the quasi-periodic oscillation (QPO) peaks as well as the damping of higher frequency harmonics in the power spectrum. We derived a number of analytic results that agree closely with more detailed numerical calculations. Three primary pieces are developed: the superposition of multiple hot spots with finite lifetimes and random phases, a width in the radial distribution of geodesic orbits, and the scattering of photons from the hot spot through a corona around the black hole. The complete model is used to fit the observed power spectra of both type A and type B QPOs seen in XTE 51550-564, giving confidence limits on each of the model parameters. These results were presented in a conference paper and in a refereed publication. We also explored the possibility of using higher-order statistics, particularly the bispectrum and bicoherence, to distinguish between competing QPO models. These methods were applied to the hot spot model and a method was proposed to map out the spacetime metric around Kerr black holes in Ref. 3 below.

Bertschinger, Edmund↗

WE-E-18C-01: Multi-Energy CT: Current Status and Recent Innovations

Conventional computed tomography (CT) uses a single polychromatic x-ray spectrum and energy integrating detectors, and produces images whose contrast depends on the effective attenuation coefficient of the broad spectrum beam. This can introduce errors from beam hardening and does not produce the optimal contrast-to-noise ratio. In addition, multiple materials can have the same effective attenuation coefficient, causing different materials to be indistinguishable in conventional CT images. If transmission measurements at two or more energies are obtained, even with polychromatic beams, more specific information about the object can be obtained. If the object does not contain materials with k-edges in the spectrum, the x-ray attenuation can be well-approximated by a linear combination of two processes (photoelectric absorption and Compton scattering) or, equivalently, two basis materials. For such cases, two spectral measurements suffice, although additional measurements can provide higher precision. If K-edge materials are present, additional spectral measurements can allow these materials to be isolated. Current commercial implementations use varied approaches, including two sources operating a different kVp, one source whose kVp is rapidly switched in a single scan, and a dual layer detector that can provide spectral information in every reading. Processing of the spectral information can be performed in the raw data domain or in the image domain. The process of calculating the amount of the two basis functions implicitly corrects for beam hardening and therefore can lead to improvements in quantitative accuracy. Information can be extracted to provide material specific information beyond that of conventional CT. This additional information has been shown to be important in several clinical applications, and can also lead to more efficient clinical protocols. Recent innovations in x-ray sources, detectors, and systems have made multi-energy CT much more practical and improved its performance. In addition, this is a very active area of research and further improvements are expected through further technological improvements. Learning Objectives: Basic principles of multi-energy CT Current implementations of mutli-energy CT Data and image analysis methods in multi-energy CT Current clinical applications of dual energy CT5. recent innovations and anticipated advances in multi-energy CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗