Search NASASearch

SEARCH · Search NASA

Results for “12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3,403 records · Page 49

Shear and combustion characterization of printable ammonium perchlorate composite propellant formulations

Seven formulations of ammonium perchlorate composite propellant (APCP) are developed and their properties relevant for successful additive manufacture are characterized. Extrusion in a custom-built 3D printing system and spindle viscometry are used to collect viscosity measurements of curing primary and non-curing secondary versions of the formulations. The formulations that behave similarly to a Bingham plastic, with apparent viscosities between 4 and 8 thousand Pa*s at 30 minutes post-mix, are determined to be most suitable for printing applications. Measurements of one material show a yield stress of 1 kPa. Ambient pressure burn rates of 2.0–2.9 mm/s were measured for the compositions tested. All measured burn rates were comparable to the lower end of typical burn rates for APCP. In conclusion, the results of the characterization demonstrate a propellant suitable for use in a 3D printing system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Design, Build, and Testing of the Roman Space Telescope’s Wide Field Instrument Optical Stimulus System (SORC)

The Stimulus Of Ray Cones (SORC) is an optical stimulus system developed to verify, characterize, and calibrate the Roman Space Telescope’s (RST) Wide Field Instrument (WFI) under simulated operational conditions. SORC provides several critical test modes, the primary being point-source mode, which projects an image anywhere on the Focal Plane Assembly (FPA) detectors. This mode provides precise position knowledge of the FPA within WFI. Additional modes enable capturing WFI pupil alignment, evaluation of WFI’s selectable optical elements, and verification of focal plane fiber operation for higher-level system testing. The light source system incorporates a suite of narrowband and broadband fiber fed sources spanning the visible to near-infrared range, with options for pulsed or continuous wave illumination. SORC was designed and built at NASA’s Goddard Spaceflight Center (GSFC). Initial system-level testing occurred under ambient conditions in GSFC’s Spacecraft Systems Development and Integration Facility (SSDIF), followed by vacuum testing at operational temperatures (SORC at 214-222 K) in the Space Environment Simulator (SES). The system was then shipped to BAE Systems in Boulder, CO for post-shipment ambient and cryogenic testing before integration with WFI for two thermal vacuum test campaigns at cryogenic temperatures. This presentation will focus on design, development, and performance of SORC. Details of WFI verification and calibration using SORC, along with test results, have been published previously and will be referenced only as needed to describe SORC. The SORC ground test capability is critical to ensuring WFI meets stringent optical performance requirements, directly supporting the mission’s science objectives.

Stimulus of Ray Cones

Turbofan Engine Power Extraction Demonstration Final Report

As GE Aerospace advances toward a revolutionary step change in propulsion efficiency, the integration and demonstration of new engine architectures and technology systems are essential. The NASA Turbofan Engine Power Extraction Demonstration (PEx), conducted through the Hybrid Thermally Efficient Core (HyTEC) project, aims to develop and demonstrate megawatt-class hybrid electric capability on a modern commercial turbofan engine. The hybrid electric system is critical to meeting the needs of the U.S. aviation industry for next-generational propulsion systems with greater efficiency, durability, and range. This supports energy independence and helps ensure the security and resilience of one of America's largest export industries. The PEx project specifically targets three key objectives: mechanically integrating hybrid electric capability into a commercial turbofan engine, integrating electric machine control with turbofan control for advanced power management, and de-risking performance modeling of future hybrid electric architectures. To mature these technologies to Technology Readiness Level (TRL) 6, a series of electric power system component tests and a baseline engine performance test campaign were conducted. These efforts culminated in an integrated hybrid electric turbofan test campaign demonstrating power extraction, power insertion, and power transfer between spools. Tests of the electric power system were completed at GE Aerospace’s Electrical Power Integrated Systems Center in Dayton, Ohio and engine tests were completed at Peebles Test Operation in Peebles, Ohio. Hybrid electric trade studies extended the demonstrated capability to altitude using the validated cycle model from the PEx test campaigns, allowing for comments on expanded mission benefits not demonstrated in the ground campaign. The knowledge gained from PEx also supports GE Aerospace’s Compact Core Demonstrator as part of HyTEC Phase 2 and ultimately informs the implementation of hybrid electric systems in the next generation of GE Aerospace commercial engine products. This report provides a summary of the program background, test campaigns, trade studies, and insights into the technical maturation required to support future commercial products.

Hybrid Electric

Adsorption, charge transfer and a coverage-driven transition of alkali metals on rutile TiO 2 (110)

The interaction of alkali metals with metal oxide surfaces is central to tuning surface reactivity in heterogeneous catalysis and photocatalysis. Here we present a comprehensive DFT+U study of the adsorption of alkali metals (Li, Na, K, Rb, Cs) on the (110) surface of rutile TiO 2 . At low coverage (θ = 1/8), all alkali metals bind preferentially to bridging oxygen sites with adsorption energies in the range −4.06 to −3.33 eV, transferring nearly one full electron (0.92–0.99 |e|) to the substrate and inducing Ti 4+ → Ti 3+ reduction. The excess charge localizes preferentially at subsurface Ti sites in the form of small polarons. Diffusion barriers indicate facile motion along bridging-oxygen rows, whereas inter-row hopping is strongly hindered. Coverage effects were examined systematically for potassium: adsorption energy and charge transfer per K atom decrease monotonically with increasing θ. Strikingly, a sharp energy discontinuity occurs between θ = 4/8 and θ = 5/8 (ΔE ≈ 1 eV per atom), which we identify as a coverage-driven structural transition arising from steric packing constraints and enhanced K–K electrostatic repulsion once every (1×1) surface cell is occupied. This structural transition perfectly correlates with a dramatic drop in the work function down to an ultra-low minimum of 0.84 eV at θ=5/8, followed by a metallization- driven recovery at higher coverages. Ab initio molecular dynamics simulations confirm zigzag K arrangements at moderate coverage (θ = 1/3), while at high coverage (θ = 2/3) short-range K–K correlations emerge without long-range order. These results provide atomistic insight into the structure–activity relationships underlying alkali promotion effects on oxide-supported catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

The HEROIX Broadband X-Ray Space Telescope Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept envisions a next-generation broadband X-ray observatory designed to meet the astrophysics community’s need for high-angular-resolution studies of the Cosmic X-ray Background. Building on the science legacy of NASA’s NuSTAR mission and more than 30 years of advances in replicated NiCo shell technology at NASA Marshall, HEROIX proposes a space observatory comprising four co-aligned telescopes achieving 5 arcsecond half-power diameter (HPD) angular resolution. This capability, approached by the resolution demonstrated in the FOXSI-4 sounding rocket mission and under development through the SuperHERO balloon mission, will be extended to energies up to 80 keV through multilayer coatings. Marshall’s inhouse precision optics manufacturing enables an integrated effective area of 380 cm² at 30 keV, which, combined with high-resolution optics, opens new windows into extreme astrophysical non-thermal processes.

Nick Thomas

Workshop on Advances in NASA-Relevant, Minimally Invasive Instrumentation

The purpose of this meeting is to highlight those advances in instrumentation and methodology that can be applied to the medical problems that will be encountered as the duration of manned space missions is extended. Information on work that is presently being done by NASA as well as other approaches in which NASA is not participating will be exchanged. The NASA-sponsored efforts that will be discussed are part of the overall Space Medicine Program that has been undertaken by NASA to address the medical problems of manned spaceflight. These problems include those that have been observed in the past as well as those which are anticipated as missions become longer, traverse different orbits, or are in any way different. This conference is arranged in order to address the types of instrumentation that might be used in several major medical problem areas. Instrumentation that will help in the cardiovascular, musculoskeletal, and psychological areas, among others will be presented. Interest lies in identifying instrumentation which will help in learning more about ourselves through experiments performed directly on humans. Great emphasis is placed on non-invasive approaches, although every substantial program basic to animal research will be needed in the foreseeable future. Space Medicine is a rather small affair in what is primarily an engineering organization. Space Medicine is conducted throughout NASA by a very small skeleton staff at the headquarters office in Washington and by our various field centers. These centers include the Johnson Space Center in Houston, Texas, the Ames Research Center in Moffett Field, California, the Jet Propulsion Laboratory in Pasadena, California, the Kennedy Space Center in Florida, and the Langley Research Center in Hampton, Virginia. Throughout these various centers, work is conducted in-house by NASA's own staff scientists, physicians, and engineers. In addition, various universities, industries, and other government laboratories perform research that cannot be effectively carried out in-house. At the moment, approximately 50% of the work is performed in-house and 50% is extramural. The area of bioinstrumentation pervades every one of our problem areas. In each, equipment or procedures are being developed that will allow more clinical work to be done in a ground-based or spacecraft setting. Although work of this kind goes on throughout the NASA organization and through its grants and contracts in the community at large, the major thrust of it is concentrated at the Jet Propulsion Laboratory which plays a lead role in this type of research and acts as the lead center in bioinstrumentation for NASA. It is recognized that there is much additional research being pursued in this area which would be potentially valuable to NASA and could, with some stimulation from, be made more applicable to NASA's needs. It is hoped, therefore, that the proceedings of this conference will be used as the basis for developing research strategies to be used as a road map to point the way in which NASA's own sponsored program should proceed over the course of the next three years. Additionally, it is hoped that the conference will highlight additional areas in which NASA should be involved either in-house or through the sponsorship of non-NASA scientists. NASA would also like to get an idea of which areas should be emphasized or perhaps de-emphasized among those that it is currently pursuing. In considering these questions, the discussion should concern itself not so much with whether a particular procedure or piece of equipment would work in a spacecraft, but rather, with whether the procedures that are advocated are at the state-of-the-art or beyond the state-of-the-art and whether they hold promise of giving additional insight into the problems to be confronted as humans venture into space for longer and longer periods of time.

Source record

LES-Based Analysis of Film Cooling in a High-Pressure Turbine Rotor Including Effects of Purge and Tip Flow

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Secondary Flows

Development of an Additively Manufactured Subscale Secondary Sealed Container for the NASA FROSTE Project

This presentation details the development of an additively manufactured (AM) subscale test article for the secondary sealed container (SSC) as part of the NASA FROSTE project. FROSTE is focused on the collection of regolith samples from shadowed regions of the Moon and the preservation of those samples at cryogenic temperatures for return to Earth. Our team was integrated into the FROSTE program to leverage innovative design approaches and additive manufacturing capabilities in support of a scalable development strategy, where the subscale configuration serves as the development path toward a full-scale SSC. Scalmalloy was selected as the primary material for all AM components due to its favorable strength-to-weight ratio, thermal conductivity, and demonstrated performance in aerospace applications. Its aluminum-based composition supports robust mechanical behavior at cryogenic temperatures while enabling efficient heat transfer and control of thermal gradients within the containment system. The SSC architecture consists of an outer container assembly that houses a phase change material (PCM) tank, which in turn contains primary containers holding the regolith. Thermal management relies on controlled conductive and radiative heat transfer, including a thermal connection assembly that interfaces the PCM tank to an external cryocooler via a thermal strap, and IMLI surrounding the PCM tank to inhibit radiative heat transfer. The outer container assembly incorporates sealing interfaces, thermal connection ports, and I/O feedthroughs, with PTFE spring seals used at critical interfaces to maintain containment integrity. The PCM tank is manufactured as a single monolithic Scalmalloy component and incorporates an integral lattice structure to minimize thermal gradients, internal channels for thermocouple routing, and interface features for thermal connection assembly integration. The tank is centrally suspended within the outer container using support rings, with G10 insulating components employed to inhibit thermal leaks. This work describes the design methodology, AM approach, and key considerations used to inform the design.

regolith

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup

First in operando transient grating spectroscopy measurements on tungsten during high flux plasma operation in PISCES-RF

This work details the construction and first in operando transient grating spectroscopy measurements conducted on PISCES-RF during plasma operation. A preliminary study on a tungsten sample with varied plasma species (Ar and D 2 ), ion flux (4 × 10 21 to 6 × 10 22 ion/m 2 /s), ion energy (5 to 80 eV), and surface temperature (20 to 200 °C) is presented. Prior to plasma exposure, the thermal diffusivity and surface acoustic wave (SAW) speed, (6.9 ± 0.2) × 10 −5 m 2 /s and (2.66 ± 0.02) km/s, were measured in situ with a thermal grating period of 12.5 μm. During Ar plasma exposure, these two quantities vary according to the sample surface temperature. At low flux and varied ion energy, D 2 plasma exposure also results in thermal diffusivity and SAW speed varying with surface temperature alone. At high flux, D 2 plasma exposure results in no convincing change to the thermal diffusivity, but the SAW speed is reduced. After returning to 20 °C, post plasma exposures, the thermal diffusivity and SAW speed almost recover to the initial value prior to exposure.

Surface acoustic wave SAW

Cold Spray Cobalt Magnetostrictive Electromagnetic Acoustic Transducers for High Temperature Structure Monitoring

The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.

Glass, Samuel W.

Magnetically and optically active edges in phosphorene nanoribbons

Abstract Nanoribbons, nanometre-wide strips of a two-dimensional material, are a unique system in condensed matter. They combine the exotic electronic structures of low-dimensional materials with an enhanced number of exposed edges, where phenomena including ultralong spin coherence times 1,2 , quantum confinement 3 and topologically protected states 4,5 can emerge. An exciting prospect for this material concept is the potential for both a tunable semiconducting electronic structure and magnetism along the nanoribbon edge, a key property for spin-based electronics such as (low-energy) non-volatile transistors 6 . Here we report the magnetic and semiconducting properties of phosphorene nanoribbons (PNRs). We demonstrate that at room temperature, films of PNRs show macroscopic magnetic properties arising from their edge, with internal fields of roughly 240 to 850 mT. In solution, a giant magnetic anisotropy enables the alignment of PNRs at sub-1-T fields. By leveraging this alignment effect, we discover that on photoexcitation, energy is rapidly funnelled to a state that is localized to the magnetic edge and coupled to a symmetry-forbidden edge phonon mode. Our results establish PNRs as a fascinating system for studying the interplay between magnetism and semiconducting ground states at room temperature and provide a stepping-stone towards using low-dimensional nanomaterials in quantum electronics.

Science & Technology - Other Topics

Mechanics and Cooling of the CMS Phase-II Tracker Barrel

The CMS upgrade for the High-Luminosity LHC (HL-LHC) era will allow for an incredibly high rate of data collection, to be used in the next generation of precision measurements and searches for beyond the standard model physics. A key element of this upgrade is the full replacement of the silicon strip tracker to enable level-1 triggering on track level primitives, produced by pixel-strip (PS) and strip-strip (2S) modules, tiled together to form the new detector. Mechanically supporting and cooling these modules is not trivial, as material budget in the tracker volume is highly constrained, and as the modules accrue radiation damage they risk becoming entirely non-functional if the silicon sensors are not sufficiently cooled. To address this, each region of the tracker has a bespoke solution for housing and cooling their modules, mostly depending on carbon-fiber and carbon-foam structures, with dual phase CO2 cooling. For the most central part of the tracker, the Flat Barrel with PS modules (Flat TBPS) covers the pseudorapidity range out to $|\eta|=0.4$, and the mechanical structures are manufactured, assembled, and tested entirely by Fermilab and UC Davis. This presentation will describe the intense design and testing requirements for these components, and how they will ensure strong performance of the tracker through the HL-LHC era.

Cosby, Christopher [Fermilab]

Impact of the Annealing Temperature on the Local Se Distribution and Optical Properties in CdSexTe1-x Solar Cells by Multimodal X-ray Microscopy

The introduction of Se in CdTe solar-cell absorbers has led to multiple beneficial effects in the devices, including an increased short-circuit current and an extended charge-carrier lifetime. A critical manufacturing step of CdSexTe1-x solar cells is CdCl2 annealing at high temperatures, during which Se diffuses through the absorber layer. Understanding the local Se distribution in the absorber and its impact on optical properties of the material is key for the further development of this thin-film solar cell technology. In a multimodal x-ray scanning microscopy approach, we investigated the impact of the annealing temperature of CdSexTe1-x solar cells on the Se distribution and on optical characteristics of the material. For this purpose, we exploited an upgraded x-ray excited optical luminescence (XEOL) detection unit that enables simultaneous spectrally and temporally resolved XEOL mapping at synchrotron facilities that are ideal for studying thin-film solar-cell materials with hard x-rays featuring high penetration depth and lateral resolution.

14 SOLAR ENERGY

Divergent carbon use efficiency-growth rate tradeoff in popular biological growth models

Carbon use efficiency (CUE) is an important trait emerging from processes regulating biological growth. CUE can be computed either based on the growth of structural biomass or total biomass divided by substrate uptake rate. Nonequilibrium thermodynamics and observations suggest that, for an exponentially growing population of cells, structural biomass CUE should first increase, then peak, and finally decrease with specific growth rate; meanwhile, total biomass CUE increases asymptotically with specific growth rate. We compared predictions from six popular models that are often used for plant and microbial growth in existing ecosystem models. We found that, for an exponentially growing population of biological cells, (1) the source-driven Pirt and Compromise models predict that structural biomass CUE increase asymptotically with growth rate; (2) the apparent sink-driven modified Droop model predicts that structural biomass CUE decreases with growth rate; and (3) the sink-driven variable internal storage model and two dynamic energy budget models predict that structural biomass CUE first increases, then peaks, and finally decreases with growth rate. Moreover, the modified Droop model predicts that total biomass CUE is constant with growth rate, while all other five models predict that total biomass CUE increases with growth rate asymptotically. For non-exponential biological growth, we show that there is no static relationship between total biomass CUE or structural biomass CUE with respect to either growth rate or temperature. Therefore, we contend that biological growth models should explicitly represent interactions between substrate acquisition, substate transformation, and maintenance respiration to better capture observed CUE dynamics, and the sink-driven model should be preferred for general ecosystem biogeochemistry modeling.

Tang, Jinyun [Lawrence Berkeley National Laborator