Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Instrumentation and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Preliminary Parallaxes of 40 L and T Dwarfs from the US Naval Observatory Infrared Astronometry Program

We present preliminary trigonometric parallaxes and proper motions for 22 L dwarfs and 18 T dwarfs measured using the ASTROCAM infrared imager on the US naval Observatory (USNO) 1.55 m Strand Astrometric Reflector. The results presented here are based on observations obtained between 2000 September and 2002 November; about half of the objects have an observational time baseline of t 1:3 yr and half t 2:0 yr. Despite these short time baselines, the astrometric quality is sufficient to produce significant new results, especially for the nearer T dwarfs. Seven objects are in common with the USNO optical CCD parallax program for quality control and seven in common with the European Southern Observatory 3.5 m New Technology Telescope parallax program. We compare astrometric quality with both of these programs. Relative to absolute parallax corrections are made by employing Two Micron All Sky Survey and/or Sloan Digital Sky Survey photometry for reference-frame stars. We combine USNO infrared and optical parallaxes with the best available California Institute of Technology (CIT) system photometry to determine MJ , MH, and MK values for 37 L dwarfs between spectral types L0 and L8 and 19 T dwarfs between spectral types T0.5 and T8 and present selected absolute magnitude versus spectral type and color diagrams, based on these results. Luminosities and temperatures are estimated for these objects. Of special interest are the distances of several objects that are at or near the L-T dwarf boundary so that this important transition can be better understood. The previously reported early to mid T dwarf luminosity excess is clearly confirmed and found to be present at J, H, and K. The large number of objects that populate this luminosity-excess region indicate that it cannot be due entirely to selection effects. The T dwarf sequence is extended to MJ 16:9 by 2MASS J041519 0935, which, at d 5:74 pc, is found to be the lluminous LOG (L=L )pa

L DWARFS↗

Second International Airborne Remote Sensing Conference and Exhibition

The conference provided four days of displays and scientific presentations on applications, technology, a science of sub-orbital data gathering and analysis. The twelve displayed aircraft equipped with sophisticated instrumentation represented a wide range of environmental and reconnaissance missions,including marine pollution control, fire detection, Open Skies Treaty verification, thermal mapping, hydrographical measurements, military research, ecological and agricultural observations, geophysical research, atmospheric and meterological observations, and aerial photography. The U.S. Air Force and the On-Site Inspection Agency displayed the new Open Skies Treaty verification Boeing OC 135B that promotes international monitoring of military forces and activities. SRl's Jetstream uses foliage and ground penetrating SAR for forest inventories, toxic waste delineation, and concealed target and buried unexploded ordnance detection. Earth Search Sciences's Gulfstream 1 with prototype miniaturized airborne hyperspectral imaging equipment specializes in accurate mineral differentiation, low-cost hydrocarbon exploration, and nonproliferation applications. John E. Chance and the U.S. Army Corps of Engineers displayed the Bell 2 helicopter with SHOALS that performs hydrographic surveying of navigation projects, coastal environment assessment, and nautical charting surveys. Bechtel Nevada and U.S. DOE displayed both the Beech King AIR B-200 platform equipped to provide first response to nuclear accidents and routine environmental surveillance, and the MBB BO-105 helicopter used in spectral analysis for environmental assessment and military appraisal. NASA Ames Research Center's high-altitude Lockheed ER-2 assists in earth resources monitoring research in atmospheric chemistry, oceanography, and electronic sensors; ozone and greenhouse studies and satellite calibration and data validation. Ames also showcased the Learjet 24 Airborne Observatory that completed missions in Venus cloud cover analysis, Quadantid meteor shower studies, extra-solar far infrared ionic structure lines measurement, Cape Kennedy launch support, and studies in air pollution, The Products and Services Exhibit showcased new sensor and image processing technologies, aircraft data collection services, unmanned vehicle technology, platform equipment, turn-key services, software a workstations, GPS services, publications, and processing and integration systems by 58 exhibitors. The participation of aircraft users and crews provided unique dialogue between those who plan data collection a operate the remote sensing technology, and those who supply the data processing and integration equipment. Research results using hyperspectral imagery, radar and optical sensors, lidar, digital aerial photography, a integrated systems were presented. Major research and development programs and campaigns we reviewed, including CNR's LARA Project and European Space Agency's 1991-1995 Airborne Campaign. The pre-conference short courses addressed airborne video, photogrammetry, hyperspectral data analysis, digital orthophotography, imagery and GIS integration, IFSAR, GPS, and spectrometer calibration.

Source record↗

Design and performance testing of a novel far field Gamma system to assay radioactive waste in 400 and 200 litre drums - 15339

A Far Field Gamma ray Measurement system has been developed for measuring and assaying both 400 and 200 litre waste drums with a wide range of activity at nuclear power stations. These include radioactive waste drums with surface dose-rates of less than 2 mSv/h (200 mrem/h) and, at the higher range of activity, 400 litre drums with surface dose-rates of up to 50 mSv/h (5 rem/h). The assay system incorporates an electro-mechanically cooled high purity Germanium profile detector and advanced digital spectroscopic analysis electronics. A novel optimised conical-trapezoidal collimator has been incorporated to reduce the effect of the radioactive background in addition to the conventional detector lead shield with tin and copper graded lining to reduce the effect of lead X-rays. Two features have been incorporated to reduce detector dead time and maintain detector resolution when measuring high activity drums. The first is the inclusion of two automated tungsten filters of different thickness as an integral part of the detector collimator. The filters are used in conjunction with an automated rail system on which the detector platform is mounted. The detector can be positioned at different distances from the drum surface in order to reduce detector dead time. The deployment of the filters and the adjustment of the drum - detector position are automatically controlled based on a user defined dose-rate limit table. The data is provided by two Geiger-Muller dose-rate detectors, which are used to measure the drum surface dose-rate. This data is subsequently used to adjust the detector position and in cases of higher dose-rate deploy one or other of the tungsten filters. The drum rotation platform incorporates a load cell to determine drum weight and hence the drum density. This information is used to calculate an attenuation correction based on the assumption of uniform drum density and uniform distribution of activity within the drum. Where the waste drums have a more complicated and known regular internal structure, such as a small radioactive region surrounded by an annulus of shielding material, the analysis algorithms incorporated into the far field geometry and attenuation correction spectroscopic data analysis code are able to make a more accurate determination of drum activity than would be possible assuming a completely uniform drum. The detector energy and efficiency calibration is achieved using a point source with multiple gamma ray energy peaks. The response of the high purity Germanium detector is also modelled using the Monte Carlo Neutron Photon code and the model is benchmarked using the measured point source calibration data. The performance of the instrument has been determined for a range of uniform density matrix drums containing a set of Eu-152 line or rod sources located in re-entrant tubes positioned on an equal volume basis. When rotated, the test drums with volume distributed line sources simulate waste drums of different density each with a uniformly distributed radioactive source. The measurements have been validated using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-FG-201-09: Predicting Accelerator Dysfunction

Purpose: To develop an integrated statistical process control (SPC) framework using digital performance and component data accumulated within the accelerator system that can detect dysfunction prior to unscheduled downtime. Methods: Seven digital accelerators were monitored for twelve to 18 months. The accelerators were operated in a ‘run to failure mode’ with the individual institutions determining when service would be initiated. Institutions were required to submit detailed service reports. Trajectory and text log files resulting from a robust daily VMAT QA delivery were decoded and evaluated using Individual and Moving Range (I/MR) control charts. The SPC evaluation was presented in a customized dashboard interface that allows the user to review 525 monitored parameters (480 MLC parameters). Chart limits were calculated using a hybrid technique that includes the standard SPC 3σ limits and an empirical factor based on the parameter/system specification. The individual (I) grand mean values and control limit ranges of the I/MR charts of all accelerators were compared using statistical (ranked analysis of variance (ANOVA)) and graphical analyses to determine consistency of operating parameters. Results: When an alarm or warning was directly connected to field service, process control charts predicted dysfunction consistently on beam generation related parameters (BGP)– RF Driver Voltage, Gun Grid Voltage, and Forward Power (W); beam uniformity parameters – angle and position steering coil currents; and Gantry position accuracy parameter: cross correlation max-value. Control charts for individual MLC – cross correlation max-value/position detected 50% to 60% of MLCs serviced prior to dysfunction or failure. In general, non-random changes were detected 5 to 80 days prior to a service intervention. The ANOVA comparison of BGP determined that each accelerator parameter operated at a distinct value. Conclusion: The SPC framework shows promise. Long term monitoring coordinated with service will be required to definitively determine the effectiveness of the model. Varian Medical System, Inc. provided funding in support of the research presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. Further, the NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C 3 ) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C 3 . The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.

47 OTHER INSTRUMENTATION↗

Work on Planetary Atmospheres and Planetary Atmosphere Probes

A summary final report of work accomplished is presented. Work was performed in the following areas: (1) Galileo Probe science analysis, (2) Galileo probe Atmosphere Structure Instrument, (3) Mars Pathfinder Atmosphere Structure/Meteorology instrument, (4) Mars Pathfinder data analysis, (5) Science Definition for future Mars missions, (6) Viking Lander data analysis, (7) winds in Mars atmosphere Venus atmospheric dynamics, (8) Pioneer Venus Probe data analysis, (9) Pioneer Venus anomaly analysis, (10) Discovery Venus Probe Titan probe instrument design, and (11) laboratory studies of Titan probe impact phenomena. The work has resulted in more than 10 articles published in archive journals, 2 encyclopedia articles, and many working papers. This final report is organized around the four planets on which there was activity, Jupiter, Mars, Venus, and Titan, with a closing section on Miscellaneous Activities. A major objective was to complete the fabrication, test, and evaluation of the atmosphere structure experiment on the Galileo probe, and to receive, analyze and interpret data received from the spacecraft. The instrument was launched on April 14, 1989. Calibration data were taken for all experiment sensors. The data were analyzed, fitted with algorithms, and summarized in a calibration report for use in analyzing and interpreting data returned from Jupiter's atmosphere. The sensors included were the primary science pressure, temperature and acceleration sensors, and the supporting engineering temperature sensors. Computer programs were written to decode the Experiment Data Record and convert the digital numbers to physical quantities, i.e., temperatures, pressures, and accelerations. The project office agreed to obtain telemetry of checkout data from the probe. Work to extend programs written for use on the Pioneer Venus project included: (1) massive heat shield ablation leading to important mass loss during entry; and (2) rapid planet rotation, which introduced terms of motion not needed on Venus. When the Galileo Probe encountered Jupiter, analysis and interpretation of data commenced. The early contributions of the experiment were to define (1) the basic structure of the deep atmosphere, (2) the stability of the atmosphere, (3) the upper atmospheric profiles of density, pressure, and temperature. The next major task in the Galileo Probe project was to refine, verify and extend the analysis of the data. It was the verified, and corrected data, which indicated a dry abiabatic atmosphere within measurement accuracy. Temperature in the thermosphere was measured at 900 K. Participation in the Mars atmospheric research included: (1) work as a team member of the Mars Atmosphere Working Group, (2) contribution to the Mars Exobiology Instrument workshop, (3) asssistance in planning the Mars global network and (4) assitance in planning the Soviet-French Mars mission in 1994. This included a return to the Viking Lander parachute data to refine and improve the definition of winds between 1.5 and 4 kilometer altitude at the two entry sites. The variability of the structure of Mars atmosphere was addressed, which is known to vary with season, latitude, hemisphere and dust loading of the atmosphere. This led to work on the Pathfinder project. The probe had a deployable meteorology mast that had three temperature sensors, and a wind sensor at the tip of the mast. Work on the Titan atmospheric probe was also accomplished. This included developing an experiment proposal to the European Space Agency (ESA), which was not selected. However, as an advisor in the design and preparation of the selected experiment the researcher interacted with scientist on the Huygens Probe Atmosphere Structure Experiment. The researcher also participated in the planning for the Venus Chemical Probe. The science objectives of the probe were to resolve unanswered questions concerning the minor species chemistry of Venus' atmosphere that control cloud formation, greenhouse effectiveness, and the thermal structure. The researcher also reviewed problems with the Pioneer Venus Probe, that caused anomalies which occurred on the Probes at and below 12.5 km level of the Venus' atmosphere. He convened and participated in a workshop that concluded the most likely hardware cause was insulation failure in the electrical harness outside the Probes' pressure vessels. It was discovered that the shrink tubing material failed at 600K. This failure could explain the anomalies experienced by the probes. The descent data of the Pioneer probes, and the Soviet Vega Lander was analyzed to evaluate the presence of small scale gravity waves in and below the Venus cloud layer.

Lester, Peter↗

MS/MS-Assisted Design of Sequence-Controlled Synthetic Polymers for Improved Reading of Encoded Information

In order to improve their MS/MS sequencing, structure of sequence-controlled synthetic polymers can be optimized based on considerations regarding their fragmentation behavior in collision-induced dissociation conditions, as demonstrated here for two digitally encoded polymer families. In poly(triazole amide)s, the main dissociation route proceeded via cleavage of the amide bond in each monomer, hence allowing the chains to be safely sequenced. However, a competitive cleavage of an ether bond in a tri(ethylene glycol) spacer placed between each coding moiety complicated MS/MS spectra while not bringing new structural information. Changing the tri(ethylene glycol) spacer to an alkyl group of the same size allowed this unwanted fragmentation pathway to be avoided, hence greatly simplifying the MS/MS reading step for such undecyl-based poly(triazole amide)s. In poly(alkoxyamine phosphodiester)s, a single dissociation pathway was achieved with repeating units containing an alkoxyamine linkage, which, by very low dissociation energy, made any other chemical bonds MS/MS-silent. Structure of these polymers was further tailored to enhance the stability of those precursor ions with a negatively charged phosphate group per monomer in order to improve their MS/MS readability. Increasing the size of both the alkyl coding moiety and the nitroxide spacer allowed sufficient distance between phosphate groups for all of them to be deprotonated simultaneously. Because the charge state of product ions increased with their polymerization degree, MS/MS spectra typically exhibited groups of fragments at one or the other side of the precursor ion depending on the original α or ω end-group they contain, allowing sequence reconstruction in a straightforward manner. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Low-Power Time-to-Digital Converter for the CMS Endcap Timing Layer (ETL) Upgrade

We present the design and test results of a Time-to-Digital-Converter (TDC). The TDC will be a part of the readout ASIC, called ETROC, to read out Low-Gain Avalanche Detectors (LGADs) for the CMS Endcap Timing Layer (ETL) of High-Luminosity LHC upgrade. One of the challenges of the ETROC design is that the TDC is required to consume less than 200 W for each pixel at the nominal hit occupancy of 1%. To meet the low-power requirement, we use a single delay line for both the Time of Arrival (TOA) and the Time over Threshold (TOT) measurements without delay control. A double-strobe self-calibration scheme is used to compensate for process variation, temperature, and power supply voltage. The TDC is fabricated in a 65 nm CMOS technology. The overall performances of the TDC have been evaluated. The TOA has a bin size of 17.8 ps within its effective dynamic range of 11.6 ns. The effective measurement precision of the TOA is 5.6 ps and 9.9 ps with and without the nonlinearity correction, respectively. The TDC block consumes 97 W at the hit occupancy of 1%. Over a temperature range from 23 C to 78 C and a power supply voltage range from 1.05 V to 1.35 V (the nominal value of 1.20 V), the self-calibrated bin size of the TOA varies within 0.4%. The measured TDC performances meet the requirements except that more tests will be performed in the future to verify that the TDC complies with the radiation-tolerance specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of Structural Health Monitoring Framework by Optimizing Vibro-Acoustic Modulation Technique to Localize Alkali-Silica Reaction Degradation in Medium-Sized Concrete Samples

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Health monitoring of concrete structures is performed to understand the current condition of a structure based on heterogeneous measurements and then produce high confidence actionable information regarding structural integrity. This information can then be used to support operational and maintenance decisions. The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, wells, placitas, and spratt) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Vibro-acoustic methods were used on these slabs to locate large pockets of ASR within the reactive samples and determine the effects of rebar using the non-reactive slabs. Vibro-acoustic modulation (VAM) is a vibration-based NDE method that utilizes signatures of nonlinear dynamic interactions on contact surfaces of crack or delamination damage to detect and localize the damage. VAM analysis was conducted on both Vanderbilt and Alabama’s samples using multiple variables for damage detection and localization. The results from the data analysis of the NDE vibro-acoustic techniques on concrete slabs cured at Vanderbilt University and the University of Alabama are discussed in detail in this report. The major outcome of the analysis suggests that the VAM method can be used to detect damage within the concrete samples by comparing the results found in different sections of the samples. Results for damage localization are dependent on multiple variables used in the vibro-acoustic modulation experiments. Digital image correlation (DIC) is a three-dimensional, full-field, optical NDE technique to measure contour, deformation, vibration, and strain. The application of the digital image correlation technique to study ASR-related degradation on a large concrete sample at the University of Tennessee Knoxville is discussed and observations are presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Patient Dose Reference Levels for Interventional Radiology: A National Approach

A set of patient dose reference levels (RLs) for fluoroscopically guided interventional procedures was obtained in a survey launched by the National Society of Interventional Radiology (IR), involving 10 public hospitals, as recommended by the European Medical Exposures Directive. A sample of 1391 dose values (kerma area product [KAP]) was collected randomly during clinical procedures for seven of the most frequent procedures. Third quartiles of the KAP distributions were used to set the RLs. A regular quality control of the X-ray systems and a calibration of the dose meters were performed during the survey. The fluoroscopy time and total number of digital subtraction angiography images per procedure were also analyzed. The RL values proposed were 12 Gy cm{sup 2} for fistulography (hemodialysis access; sample of 180 cases), 73 Gy cm{sup 2} for lower limb arteriography (685 cases), 89 Gy cm{sup 2} for renal arteriography (55 cases), 80 Gy cm{sup 2} for biliary drainage (205 cases), 289 Gy cm{sup 2} for hepatic chemoembolization (151 cases), 94 Gy cm{sup 2} for iliac stent (70 cases), and 236 Gy cm{sup 2} for uterine embolization (45 cases). The provisional national RL values are lower than those obtained in a similar survey carried out in the United States from 2002 to 2004. These new values could be used to improve the practice of centers consistently working with doses higher than the RLs. This national survey also had a positive impact, as it helped increase the awareness of the members of the National Society of IR on a topic as crucial as patient dose values and programs on radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SLAC microresonator RF(SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays

Here, we describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.

47 OTHER INSTRUMENTATION↗

3D parallel-detection microwave tomography for clinical breast imaging

A biomedical microwave tomography system with 3D-imaging capabilities has been constructed and translated to the clinic. Updates to the hardware and reconfiguration of the electronic-network layouts in a more compartmentalized construct have streamlined system packaging. Upgrades to the data acquisition and microwave components have increased data-acquisition speeds and improved system performance. By incorporating analog-to-digital boards that accommodate the linear amplification and dynamic-range coverage our system requires, a complete set of data (for a fixed array position at a single frequency) is now acquired in 5.8 s. Replacement of key components (e.g., switches and power dividers) by devices with improved operational bandwidths has enhanced system response over a wider frequency range. High-integrity, low-power signals are routinely measured down to −130 dBm for frequencies ranging from 500 to 2300 MHz. Adequate inter-channel isolation has been maintained, and a dynamic range >110 dB has been achieved for the full operating frequency range (500–2900 MHz). For our primary band of interest, the associated measurement deviations are less than 0.33% and 0.5° for signal amplitude and phase values, respectively. A modified monopole antenna array (composed of two interwoven eight-element sub-arrays), in conjunction with an updated motion-control system capable of independently moving the sub-arrays to various in-plane and cross-plane positions within the illumination chamber, has been configured in the new design for full volumetric data acquisition. Signal-to-noise ratios (SNRs) are more than adequate for all transmit/receive antenna pairs over the full frequency range and for the variety of in-plane and cross-plane configurations. For proximal receivers, in-plane SNRs greater than 80 dB are observed up to 2900 MHz, while cross-plane SNRs greater than 80 dB are seen for 6 cm sub-array spacing (for frequencies up to 1500 MHz). We demonstrate accurate recovery of 3D dielectric property distributions for breast-like phantoms with tumor inclusions utilizing both the in-plane and new cross-plane data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analog-to-digital converter based on voltage-controlled superconducting devices

The increasing demand for cryogenic electronics in superconducting and quantum computing systems calls for ultra-energy-efficient data conversion architectures that remain functional at deep cryogenic temperatures. Here, in this work, we present the first design of a voltage-controlled superconducting flash analog-to-digital converter (ADC) based on a voltage-controlled quantum-enhanced Josephson junction field-effect transistor (JJFET). Exploiting its strong gate tunability and transistor-like behavior, the JJFET offers a scalable alternative to conventional current-controlled superconducting devices while aligning naturally with CMOS-style design methodologies. Building on our previously developed Verilog-A compact model calibrated to experimental data, we design and simulate a three-bit JJFET-based flash ADC targeted for integration within cryogenic control and readout circuitry in quantum computing. The core comparator block is realized through careful bias current selection and augmented with a three-terminal nanocryotron to precisely define reference voltages. Cascaded JJFET comparators ensure robust voltage gain, cascadability, and logic-level restoration across stages. Simulation results demonstrate accurate quantization behavior with ultra-low power dissipation, underscoring the feasibility of voltage-driven superconducting mixed-signal circuits. This work establishes a critical step toward unifying superconducting logic and data conversion, paving the way for scalable cryogenic architectures in quantum–classical co-processors, low-power artificial intelligence accelerators, and next-generation energy-constrained computing platforms.

Analog-to-digital converter↗

Digitalization of an experimental electrochemical reactor via the smart manufacturing innovation platform

The exponential increase in data produced over the last two decades has revolutionized the way we collect, store, process, analyze, model, and interpret information to improve profitability. Manufacturing is no exception. How- ever, Smart Manufacturing, the digital practice, organization, workforce, and infrastructure transformation for collection and deployment of data and models at scale and at all levels of manufacturing, is a complex, costly, and labor-intensive journey that is still seeing slow adoption. The Clean Energy Smart Manufacturing Innovation Institute (CESMII), a national Manufacturing USA public-private partnership sponsored by the Department of Energy, is addressing this scaled use of data and modeling in manufacturing. CESMII has focused on how to col- lect and use operating data for numerous applications that improve productivity, precision, and performance of manufacturing operations from factory floor to supply chain using process simulation, predictive analytics, mon- itoring and control, and real-time optimization. Because contextualized data are key, CESMII has developed the Smart Manufacturing Innovation Platform (SMIP) to lower the barriers to the data that are needed to accelerate data-based model building, improve data visualization, and more quickly gain insights. Reusable, standards-based ways of doing data collection, ingestion, and contextualization are particularly important for scaling access and use of data. The SMIP uses a standards-based definition and construct for reusable information models called an SM Profile. When an SM Profile is used in conjunction with the SMIP, the SMIP ensures the availability of contextualized, operational data for model building. The present work demonstrates Smart Manufacturing and the application of the SMIP for building several data-centered models for the operation and control of an ex- perimental electrochemical reactor that reduces carbon dioxide (CO 2 ) gas to valuable liquid and gas chemicals, such as alcohols, olefins, and syngas. We describe how the SMIP plays a central role in more effective model building and we demonstrate how the electochemical reactor can be controlled and optimized for the desired products. Use of the SMIP involves the transmission of real-time sensor measurements to a cloud resource so that the operating data are available to all model building experts. The data collection and transmission process is fully automated to greatly reduce the need for manual manipulation of the data. Data-driven machine learning models are used for advanced real-time state estimation, real-time optimization, and model-based feedback control for the reactor. The application models are implemented as a system to monitor the data flow and control the electrochemical reactor with a single visualization interface. SM Profiles are used to demonstrate reusability of the information models for the reactor and the instrumentation. The application packages, algorithms, and user interfaces developed are cast as Docker images in a library to facilitate reusability of the application models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty Quantification in Vibro-Acoustics Diagnosis of Alkali-Silica Reaction Degradation in Medium-Sized Concrete Samples

The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, wells, placitas, and spratt) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Vibro-acoustic testing was used on these slabs to locate ASR damage within the reactive samples. Vibro-acoustic modulation (VAM) is a vibration-based NDE method that utilizes signatures of nonlinear dynamic interactions on contact surfaces of crack or delamination damage to detect and localize the damage. VAM analysis was conducted on both the Vanderbilt and Alabama samples using multiple variables for damage detection and localization. The results from the data analysis of the vibro-acoustic testing on concrete slabs cured at Vanderbilt University and the University of Alabama are discussed in detail in this report. Results for damage localization are dependent on multiple variables used in the vibro-acoustic modulation experiments. A major focus of this report is to quantify the uncertainty in the diagnosis due to multiple factors and uncertainty sources. The uncertainty quantification methodology presented in this report was applied to VAM-based diagnosis and prognosis. However, the methodology is general, and is capable of being applied to multiple technique that collect spatially distributed data. Future work needs to investigate the incorporation of uncertainty quantification in developing a robust Prognostics and Health Management framework. Digital image correlation is a three-dimensional, full-field, optical NDE technique to measure contour, deformation, vibration, and strain. The application of the digital image correlation technique to study ASR-related degradation on a large concrete specimen at the University of Tennessee is discussed and observations are presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast broad-band photon detector based on quantum well devices and charge-integrating electronics for non-invasive FEL monitoring

The recent evolution of free-electron lasers has not been matched by the development of adequate beam-monitoring instrumentation. However, for both experimental and diagnostics purposes, it is crucial to keep such photon beams under control, avoiding at the same time the absorption of the beam and the possible destruction of the detector. These requirements can be fulfilled by utilizing fast and non-invasive photon detectors operated in situ, upstream from the experimental station. From this perspective, sensors based on Quantum Well (QW) devices can be the key to detecting ultra-short light pulses. In fact, owing to their high electron mobility, InGaAs/InAlAs QW devices operated at room temperature exhibit sub-nanosecond response times. Their direct, low-energy band gap renders them capable of detecting photons ranging from visible to X-ray. Furthermore, the 2D electron gas forming inside the QW is responsible for a charge amplification mechanism, which increases the charge collection efficiency of these devices. In order to acquire the signals produced by these QW sensors, a novel readout electronics has been developed. It is based on a high-speed charge integrator, which allows short, low-intensity current pulses to be read within a 50-ns window. The integrated signal is acquired through an ADC and the entire process can be performed at a 10-MHz repetition rate. This work provides a detailed description of the development of the QW detectors and the acquisition electronics, as well as reporting the main experimental results, which show how these tools are well suited for the realization of fast, broad-band beam monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active-Interrogation Measurements of Induced-Fission Neutrons from Low-Enriched Uranium

Protection and control of nuclear fuels is paramount for nuclear security and safeguards; therefore, it is important to develop fast and robust controlling mechanisms to ensure the safety of nuclear fuels. Through both passive- and active-interrogation methods we can use fast-neutron detection to perform real-time measurements of fission neutrons for process monitoring. Active interrogation allows us to use different ranges of incident neutron energy to probe for different isotopes of uranium. With fast-neutron detectors, such as organic liquid scintillation detectors, we can detect the induced-fission neutrons and photons and work towards quantifying a sample’s mass and enrichment. Using MCNPX-PoliMi, a system was designed to measure induced-fission neutrons from U-235 and U-238. Measurements were then performed in the summer of 2010 at the Joint Research Centre in Ispra, Italy. Fissions were induced with an associated particle D-T generator and an isotopic Am-Li source. The fission neutrons, as well as neutrons from (n, 2n) and (n, 3n) reactions, were measured with five 5” by 5” EJ-309 organic liquid scintillators. The D-T neutron generator was available as part of a measurement campaign in place by Padova University. The measurement and data-acquisition systems were developed at the University of Michigan utilizing a CAEN V1720 digitizer and pulse-shape discrimination algorithms to differentiate neutron and photon detections. Low-enriched uranium samples of varying mass and enrichment were interrogated. Acquired time-of-flight curves and cross-correlation curves are currently analyzed to draw relationships between detected neutrons and sample mass and enrichment. In the full paper, the promise of active-interrogation measurements and fast-neutron detection will be assessed through the example of this proof-of-concept measurement campaign. Additionally, MCNPX-PoliMi simulation results will be compared to the measured data to validate the MCNPX-PoliMi code when used for active-interrogation simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An automatic input/output test experience of FPGA-based logic controller with I/O stimulator - 282

This paper describes an automatic testing approach instead of a traditional manual test for an FPGA-based Logic Controller (FLC). It mainly describes an automatic testing of FLC using an I/O stimulator with the initiated manual action. The FLC was developed by Doosan Heavy Industry and KAERI in S. Korea. We also developed a test-bed like I/O stimulator for a burning test based on the operational scenario. Signal sources from the I/O stimulator contain an analog input, an analog output, a digital input and a digital output, a programmable power supply, an RS232C serial interface, and a dual port Ethernet interface. LabVIEW Programming was used for the automatic testing. The FLC consists of a general processor module (FPM-01), a complex processor module (FPM-02), analog input modules (FAI-01), analog output modules (FAO-01), digital input modules (FDI-01), digital output modules (FDO-01), a data link module (FDL-01), and a network module (FNW-01). Among these, in this paper, automatic digital I/O testing and automatic analog I/O testing are described. In addition, for the accuracy of the automatic testing, two graphic recorders are used. One is the output results of general processor based testing, and the other is the output results of complex processor based testing. These are different company products. Redundancy recording was found in the test results. The test results were synchronized internally with the existing I/O stimulator and externally with two graphic recorders. Calibrations of all of the equipment were made before the system testing. Before the testing started, a test plan and the test procedure were set up in advance, and we performed test scenario-based automatic functional testing for the FLC as the qualification process. It can be several executed depending on the scenario and conditional parameters of the test. For validation of the accuracy and reliability in our automated test, manual testing was also performed. Manual tests were conducted in two ways. The first one was a manual test using Fluke 754 and Fluke 715. The other one was using embedded manual features of the I/O stimulator. By performing the automatic input and output testing using the I/O stimulator, the time and expense of FLC testing can be reduced significantly compared with a conventional manual test. We rechecked the automatic test results using Fluke754 manually. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗