Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

THREE-DIMENSIONAL STRUCTURE OF MICROWAVE SOURCES FROM SOLAR ROTATION STEREOSCOPY VERSUS MAGNETIC EXTRAPOLATIONS

We use rotation stereoscopy to estimate the height of a steady-state solar feature relative to the photosphere, based on its apparent motion in the image plane recorded over several days of observation. The stereoscopy algorithm is adapted to work with either one- or two-dimensional data (i.e., from images or from observations that record the projected position of the source along an arbitrary axis). The accuracy of the algorithm is tested on simulated data, and then the algorithm is used to estimate the coronal radio source heights associated with the active region NOAA 10956, based on multifrequency imaging data over seven days from the Siberian Solar Radio Telescope near 5.7 GHz, the Nobeyama Radio Heliograph at 17 GHz, as well as one-dimensional scans at multiple frequencies spanning the 5.98-15.95 GHz frequency range from the RATAN-600 instrument. The gyroresonance emission mechanism, which is sensitive to the coronal magnetic field strength, is applied to convert the estimated radio source heights at various frequencies, h(f), to information about magnetic field versus height B(h), and the results are compared to a magnetic field extrapolation derived from photospheric magnetic field observations obtained by Hinode and Michelson Doppler Imager. We found that the gyroresonant emission comes from heights exceeding the location of the third gyrolayer irrespective of the magnetic extrapolation method; implications of this finding for coronal magnetography and coronal plasma physics are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Distributed fiber-optic sensing in a subscale high-temperature superconducting dipole magnet

High-temperature superconductors, such as REBa2Cu3O7−x (REBCO, RE = rare earth), are becoming pivotal for high-field magnet technology for future circular colliders and compact fusion reactors. The U.S. Magnet Development Program, in collaboration with industry, is developing REBCO magnet technology using round conductors consisting of multiple REBCO tapes. For these multi-tape cables, traditional instrumentation, such as voltage taps and resistive strain gauges, become insufficient to help measure and understand the performance-limiting factors in these model magnets. Distributed fiber-optic sensing (DFOS) is a potential solution to address this challenge. Although DFOS is well established for various applications, measuring temperature and strain in high-temperature superconducting magnets is in its infancy. Here we report the detailed implementation and test results of DFOS based on Rayleigh scattering in a subscale canted cosθ (CCT) dipole magnet using high-temperature superconducting CORC® wires. We co-wound optical fibers in each layer of the CCT magnet and compared different types of commercial fibers and mold-release agents to reduce the power attenuation in the fibers. The DFOS allowed us to measure mechanical deformation and temperature along the conductor during tests at 77 and 4.2 K. The measured strain agreed quantitively with a finite-element mechanical model of the subscale magnet. Our results indicate that DFOS can effectively identify locations of strain and temperature changes, offering unique insight into magnet performance that can advance our understanding and development of the REBCO magnet technology for high-energy physics and fusion applications.

Luo, Linqing↗

Turbulence in the TORE SUPRA Tokamak: Measurements and Validation of Nonlinear Simulations

Turbulence measurements in TORE SUPRA tokamak plasmas have been quantitatively compared to predictions by nonlinear gyrokinetic simulations. For the first time, numerical results simultaneously match within experimental uncertainty (a) the magnitude of effective heat diffusivity, (b) rms values of density fluctuations, and (c) wave-number spectra in both the directions perpendicular to the magnetic field. Moreover, the nonlinear simulations help to revise as an instrumental effect the apparent experimental evidence of strong turbulence anisotropy at spatial scales of the order of ion-sound Larmor radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High sensitivity pump–probe measurements of magnetic, thermal, and acoustic phenomena with a spectrally tunable oscillator

We describe an optical pump/probe system for sensitive measurements of time-resolved optical measurements of material dynamics. The instrument design is optimized for time-resolved magneto-optic Kerr effect (TR-MOKE) measurements of dynamics in magnetic materials. The system also allows for time-domain thermoreflectance (TDTR) measurements of thermal transport properties and picosecond acoustic measurements of film thickness and/or elastic constants. The system has several advantages over the conventional designs for TRMOKE and/or TDTR systems. Measurements of pump-induced changes to the probe beam intensity are shot-noise limited. The system’s design allows for MOKE and/or thermoreflectance measurements of both sides of a sample. Pumping and probing the sample on opposite sides allows nanoscale flash diffusivity measurements of transport properties. The wavelengths of the pump and probe beams are straightforward to tune between 350–525 nm and 690–1050 nm. A tunable wavelength allows for optical resonances in a wide array of materials to be excited and/or probed. Finally, the setup is calibrated to allow for the real and imaginary components of Kerr signals to be separately quantified.

47 OTHER INSTRUMENTATION↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

DESIGN AND TESTING OF A DIGITAL REGULATOR FOR FERMILAB MAGNET POWER SYSTEMS

In this thesis, the design of a digitally controlled DC power system for testing conventional and superconducting magnets is proposed. The designed PID controller performances have been tested by the 30kA test stand for superconducting magnets, Vertical Magnet Test Facility (VMTF), which is hosted at the Fermilab Magnet Test Facility (MTF). The system is implemented on a National Instruments CompactRIO and both real-time and FPGA targets are programmed. A full 24-bit PID algorithm is coded and successfully tested by a manual tuning approach. An automated tuning algorithm is then introduced. As it will be shown by simulation and experimental results, the proposed system meets all design specifications. The current loop stability is up to 14 times better than the existing regulator and a control accuracy less than 4 ppm is achieved. Shorted-bus tests of the PID regulator have been successfully performed on the VMTF power system. In order to test the generalization capability of the designed system towards different types of magnets, the system has been easily adapted to and tested on the 10kA conventional magnet test stand (Stand C at Fermilab). As shown by experimental results, the designed PID controller features really high performancesin terms of steady-state accuracy and effectiveness of the tuning algorithm.

43 PARTICLE ACCELERATORS↗

Solving the auroral-arc-generator question by using an electron beam to unambiguously connect critical magnetospheric measurements to auroral images

Here, an active mapping mission is described that unambiguously connects measurements in the Earth's magnetosphere to visible aurora in the atmosphere. The core of the mission is an electron-beam source operated on a spacecraft in the equatorial magnetosphere, with the electron beam traveling along the Earth's magnetic-field lines to the atmosphere, depositing its energy to create an optical beam-spot in the atmosphere at the footpoint of the spacecraft's magnetic-field line. This optical spot can be imaged by ground-based cameras, putting the location of the spacecraft's magnetic footpoint into the context of the optical aurora. Scientific instruments carried on the spacecraft make critical measurements of the properties of the magnetosphere at the locations where the magnetosphere powers the aurora, allowing the determination of the plasma-physics mechanisms by which the magnetosphere drives the aurora, in particular answering the outstanding question of how the magnetosphere drives low-latitude auroral arcs. Long-standing questions in magnetosphere-ionosphere coupling that have not been answered because we could not unambiguously connect locations in the magnetosphere with their image in the ionosphere will finally be addressed. In this paper the properties of a “standard” growth-phase auroral arc are collected, theories of the magnetospheric generation of auroral arcs are reviewed, and critical magnetospheric measurements to discern the mechanisms that drive auroral arcs are determined. Further, the plasma physics of the experiment is investigated, including spacecraft-charging mitigation, beam stability, beam scattering, and electron orbit theory. Tradeoffs (keV versus MeV) concerning the energy of the electron beam are enumerated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-situ synthesis of magnetic (NiFe{sub 2}O{sub 4}/CuO/FeO) nanocomposites

In-situ synthesis of magnetic nanocomposites with (NiFe{sub 2}O{sub 4}/CuO/FeO) crystal phases has been done using a sol-gel method by taking a non-stoichiometric composition of the precursors. The average particle size of the nanocomposites was calculated using X-ray diffraction (XRD) and high resolution tunneling electron microscope (HR-TEM) and it turns out to be {approx}20 nm. The vibrating sample magnetometer (VSM) measurements demonstrate the ferromagnetic nature of the nanocomposites. The synthesized nanocomposite was used to prepare magnetic fluid using tetramethylammonium hydroxide as a surfactant and its stability in the solution was also discussed. -- Graphical abstract: Magnetic nanocomposites containing (NiFe{sub 2}O{sub 4}/CuO/FeO) phases having particle size {approx}17 nm were synthesized by a sol-gel method. The synthesized nanocomposites exhibit ferromagnetic nature with small value of coercivity.

36 MATERIALS SCIENCE↗

AMS-100: The next generation magnetic spectrometer in space – An international science platform for physics and astrophysics at Lagrange point 2

The next generation magnetic spectrometer in space, AMS-100, is designed to have a geometrical acceptance of 100 m 2 sr and to be operated for at least ten years at the Sun–Earth Lagrange Point 2. Compared to existing experiments, it will improve the sensitivity for the observation of new phenomena in cosmic rays, and in particular in cosmic antimatter, by at least a factor of 1000. The magnet design is based on high temperature superconductor tapes, which allow the construction of a thin solenoid with a homogeneous magnetic field of 1 Tesla inside. The inner volume is instrumented with a silicon tracker reaching a maximum detectable rigidity of 100 TV and a calorimeter system that is 70 radiation lengths deep, equivalent to four nuclear interaction lengths, which extends the energy reach for cosmic-ray nuclei up to the PeV scale, i.e. beyond the cosmic-ray knee. In conclusion, covering most of the sky continuously, AMS-100 will detect high-energy gamma-rays in the calorimeter system and by pair conversion in the thin solenoid, reconstructed with excellent angular resolution in the silicon tracker.

79 ASTRONOMY AND ASTROPHYSICS↗

Tunable electron beam pulser for picoseconds stroboscopic microscopy in transmission electron microscopes

For two decades, time-resolved transmission electron microscopes (TEM) have relied on pulsed-laser photoemission to generate electron bunches to explore sub-microsecond to sub-picosecond dynamics. Despite the vast successes of photoemission time-resolved TEMs, laser-based systems are inherently complex, thus tend not to be turn-key. In this paper, we report on the successful retrofit of a commercial 200 keV TEM, without an external laser, capable of producing continuously tunable pulsed electron beams with repetition rates from 0.1 GHz up to 12 GHz and a tunable bunch length from tens of nanoseconds down to 10 ps. This innovation enables temporal access into previously inaccessible regimes: i.e., high repetition rate stroboscopic experiments. Combination of a pair of RF-driven traveling wave stripline elements, quadrupole magnets, and a variable beam aperture enables operation of the instrument in (1) continuous waveform (CW) mode as though the instrument was never modified (i.e. convention TEM operation mode, where the electrons from the emission cathode randomly arrive at the sample without resolvable time information), (2) stroboscopic (pump-probe) mode, and (3) pulsed beam mode for dose rate sensitive materials. In order to analyze the effect of a pulsed beam on image quality, we examined Au nanoparticles using bright field, high-resolution TEM imaging and selected area diffraction in both continuous and pulsed-beam mode. Furthermore, in comparison of conventional TEMs, the add-on beam pulser enables the observation of ultrafast dynamic behavior in materials that are reversible under synchronized excitation.

36 MATERIALS SCIENCE↗

Gamma-ray superconducting detector based on Abrikosov vortices: Principle of operation

The high atomic number of some superconducting elements such as niobium (Z=41) and tantalum (Z=73) and a high material thickness (e.g., t=300 mum) are emphasized as essential properties for development of a gamma-ray solid state detector with high intrinsic detection efficiency in the energy range up to 100 keV. To exploit these properties, a new detection principle based on the interaction of a single gamma-ray photon with Abrikosov vortex is proposed. The interaction of gamma-ray photon with a superconductor is discussed in terms of the photoelectric absorption and a hot-spot formation, the last acts as a short-time pinning center on an Abrikosov vortex and activates its motion, namely, a jump or damped vibration. Both types of vortex motion lead to variation (either static or dynamic) in the magnetic field on the absorber surface. The high sensitivity of the Josephson tunneling to weak magnetic field can be exploited for revealing the magnetic field variation and to make the readout of the detector. Main intrinsic properties of a gamma-ray detector based on Abrikosov vortices are evaluated, including the possibility to measure the energy deposited in the detector. A single Josephson tunnel junction configuration or a superconducting quantum interference device (SQUID) configuration is proposed and discussed as possible realization of working gamma-ray detector both in the counter operation mode and in the radiation spectroscopy operation mode.

36 MATERIALS SCIENCE↗

Status of MICE

The Muon Ionization Cooling Experiment (MICE) is an experiment currently under construction at the Rutherford Appleton Laboratory (RAL) in the UK. The aim of the experiment is to demonstrate the concept of ionization cooling for a beam of muons, crucial for the requirements of a Neutrino Factory and a Muon Collider. Muon cooling is achieved by measuring the reduction of the four dimensional transverse emittance for a beam of muons passing through low density absorbers and then accelerating the longitudinal component of the momentum using RF cavities. The absorbers are maintained in a focusing magnetic field to reduce the beta function of the beam and the RF cavities are kept inside coupling coils. The main goal of MICE is to measure a fractional drop in emittance, of order -10% for large emittance beams, with an accuracy of 1%(which imposes a requirement that the absolute emittance be measured with an accuracy of 0.1%). This paper will discuss the status of MICE, including the progress in commissioning the muon beam line at the ISIS accelerator at RAL, the construction of the different detector elements in MICE and the prospects for the future.

43 PARTICLE ACCELERATORS↗

Moessbauer Study and Macroscopic/Global Magnetic Behavior of Powdered Ilmenite (FeTiO{sub 3}) Sample

In this article, the commercial synthetic powdered sample of ilmenite (FeTiO{sub 3}) has been re-examined by Moessbauer spectroscopy in the paramagnetic regime from 77 K to 280 K and in a magnetically ordered state below 57 K. The effective vibrating mass and the Debye temperature was found to be (78{+-}3) amu and (359{+-}27) K, respectively. The two sextet components were used for correct fitting of the Moessbauer spectra recorded at 5 K and 45 K in an external magnetic field of 5 T. Moreover, the macroscopic magnetic measurements were carried out by an MPMS XL-7 magnetometer to determine a temperature dependence of the molar susceptibility and hysteresis loops of this sample. The Moessbauer spectra and magnetization measurements confirm that below the ordering temperature of ilmenite, it behaves as a non-ideal antiferromagnetic material with a significant magnetic hardening at low temperatures. In addition, the magnetic molar susceptibility follows a Curie-Weiss law with C{sub m=5.8x10{sup -5}Km{sup 3}/mol}, and Weiss temperature {theta}{sub p} = 30.6 K.

36 MATERIALS SCIENCE↗

Dry calibration of electromagnetic flowmeters based on numerical models combining multiple physical phenomena (multiphysics)

This paper presents a method for dry calibration of an electromagnetic flowmeter (EMF). This method, which determines the voltage induced in the EMF as conductive liquid flows through a magnetic field, numerically solves a coupled set of multiphysical equations with measured boundary conditions for the magnetic, electric, and flow fields in the measuring pipe of the flowmeter. Specifically, this paper details the formulation of dry calibration and an efficient algorithm (that adaptively minimizes the number of measurements and requires only the normal component of the magnetic flux density as boundary conditions on the pipe surface to reconstruct the magnetic field involved) for computing the sensitivity of EMF. Along with an in-depth discussion on factors that could significantly affect the final precision of a dry calibrated EMF, the effects of flow disturbance on measuring errors have been experimentally studied by installing a baffle at the inflow port of the EMF. Results of the dry calibration on an actual EMF were compared against flow-rig calibration; excellent agreements (within 0.3%) between dry calibration and flow-rig tests verify the multiphysical computation of the fields and the robustness of the method. As requiring no actual flow, the dry calibration is particularly useful for calibrating large-diameter EMFs where conventional flow-rig methods are often costly and difficult to implement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetite Nanoparticles Coated with Rifampicin and Chlortetracycline for Drug Delivery Applications

Four types of biocompatible magnetic fluids based on superparamagnetic nanoparticles with Fe{sub 3}O{sub 4} cores were functionalized with antibiotics (rifampicin or chlortetracycline) as potential candidates for in vivo biomedical applications, such as magnetically controlled drug delivery. The synthesis consisted in coprecipitation of iron oxide in basic, as well as in acid medium, followed by the dispersion of the resulted magnetite nanoparticles in aqueous solution containing the antibiotic. The chosen method to prepare the magnetite-core/drug-shell systems avoided intermediate organic coating of the magnetic nanoparticles. Comparative analysis of the rheological features of the aqueous magnetic fluid samples was performed. The structural features of the coated magnetic particles were investigated by X-Ray Diffraction (XRD), Transmission Electron Microscopy (TEM) and Vibrating Sample Magnetometry (VSM). Good crystallinity and adequate stability in time were evidenced. Drug delivery curves were spectrophotometrically provided.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Precision measurement of {pi}{pi} scattering lengths at the NA48/2 experiment

The NA48/2 experiment at CERN [1] collected {approx}18{center_dot}10{sup 9} charged kaon decays during the years 2003/4. Along with the primary goals of the collaboration, i.e. the measurement of the CP-violating asymmetry in the K{sup {+-}}{yields}{pi}{sup {+-}}{pi}{sup +}{pi}{sup -} and K{sup {+-}}{yields}{pi}{sup {+-}}{pi}{sup 0}{pi}{sup 0} decays thanks to the simultaneous collection of K{sup +} and K{sup -} events, the collected data allowed to perform many other interesting analyses. In this paper two independent measurements of {pi}{pi} scattering lengths will be reviewed, using NA48/2 data from the K{sup {+-}}{yields}e{sup {+-}}{nu}{pi}{sup +}{pi}{sup -} decay and from the cusp effect in K{sup {+-}}{yields}{pi}{sup {+-}}{pi}{sup +}{pi}{sup -} respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

N- and P-Type Cluster Source

We describe our newest ClusterIon registered source, and show detailed data for B{sub 18}H{sub x}{sup +}, C{sub 7}H{sub 7}{sup +}, C{sub 16}H{sub x}{sup +}, P{sub 4}{sup +}, and As{sub 4}{sup +} beams. These species are derived from both low-temperature solids and gaseous sources. 2D beam profiles are presented, along with mass spectra, beam current performance, and long-term beam reproducibility. The data were collected using the injection stage of a commercial ion implanter equipped with a 120 degree analyzer magnet. Beam profiles at magnet entrance and exit planes were produced using a specially designed 2D profiler. Beam currents were measured after mass analysis using a Faraday cup over an effective energy range of 200 eV to 10 keV.

43 PARTICLE ACCELERATORS↗

Chemical stability of highly (0001) textured Sm(CoCu){sub 5} thin films with a thin Ta capping layer

With the highest magnetocrystalline anisotropy constant (Ku) among practical magnetic materials, SmCo{sub 5} could be a very attractive candidate for future high areal density magnetic recording. However, its corrosion resistance is always a concern in recording media applications. In this paper, the chemical stability and microstructures of highly (0001) textured Sm(CoCu){sub 5} thin films with and without a 3 nm Ta capping layer were reported. For Sm(CoCu){sub 5} thin films without a capping layer, the coercivity decreases significantly (from 8kOe to 1kOe) within one month. Sm(CoCu){sub 5} thin films capped with a thin Ta layer (3 nm) behave differently. Even exposed to a laboratory environment (25 deg. C) over 3 years, the Ta-capped Sm(CoCu){sub 5} thin films are stable in terms of structural and magnetic properties, i.e., there were no changes in X-ray diffraction peaks and vibrating sample magnetometer hysteresis loops. Microstructure of Ta-capped Sm(CoCu){sub 5} thin films showed that Sm(CoCu){sub 5} formed a domelike particle assembly structure on a smooth Ru underlayer and were well covered by partially oxidized Ta capping layer, as shown by TEM cross-section micrographs. Accelerated corrosion treatment (130 deg. C, 95% relative humidity, 6 h) was performed on Ta-capped Sm(CoCu){sub 5} thin films. X-ray photoelectron spectroscopy (XPS) results showed that no Co was detected on the sample surface before the corrosion treatment, but strong XPS signals of CoOx and Co(OH)x were observed after treatment. Therefore, none of our Sm(CoCu){sub 5} thin films can pass the accelerated corrosion test. Hcp-phased CoPt-alloys are proposed as better capping materials for Sm(CoCu){sub 5} thin films in future high-density magnetic recording applications.

36 MATERIALS SCIENCE↗