Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

High Speed Operation and Testing of a Fault Tolerant Magnetic Bearing

Research activities undertaken to upgrade the fault-tolerant facility, continue testing high-speed fault-tolerant operation, and assist in the commission of the high temperature (1000 degrees F) thrust magnetic bearing as described. The fault-tolerant magnetic bearing test facility was upgraded to operate to 40,000 RPM. The necessary upgrades included new state-of-the art position sensors with high frequency modulation and new power edge filtering of amplifier outputs. A comparison study of the new sensors and the previous system was done as well as a noise assessment of the sensor-to-controller signals. Also a comparison study of power edge filtering for amplifier-to-actuator signals was done; this information is valuable for all position sensing and motor actuation applications. After these facility upgrades were completed, the rig is believed to have capabilities for 40,000 RPM operation, though this has yet to be demonstrated. Other upgrades included verification and upgrading of safety shielding, and upgrading control algorithms. The rig will now also be used to demonstrate motoring capabilities and control algorithms are in the process of being created. Recently an extreme temperature thrust magnetic bearing was designed from the ground up. The thrust bearing was designed to fit within the existing high temperature facility. The retrofit began near the end of the summer, 04, and continues currently. Contract staff authored a NASA-TM entitled "An Overview of Magnetic Bearing Technology for Gas Turbine Engines", containing a compilation of bearing data as it pertains to operation in the regime of the gas turbine engine and a presentation of how magnetic bearings can become a viable candidate for use in future engine technology.

DeWitt, Kenneth↗

Design of a near-IR coherent lidar for high spatial and velocity resolution wind measurement

A coherent Doppler lidar based on a CW diode-pumped, injection seeded, Th:YAG laser operating at approx. 2.02 microns is currently under development. This system is optimized for measurements of boundary layer winds with high spatial, temporal, and velocity resolution. Initially, the system will run alongside a new high repetition rate (5-10 kHz) CO2 mini-Master Oscillator Power Amplifier (mini-MOPA) Doppler lidar, which will provide simultaneous range-resolved Differential Absorption Lidar (DIAL) water vapor measurements. Water vapor DIAL operation of the 2 micron system is being considered as a future option. The anticipated specifications and the preliminary design are discussed.

Grund, Christian J.↗

Formation of Subwavelength Grating on Molybdenum Mirrors Using a Femtosecond Ti:sapphire Laser System Operating at 10 Hz

We report formation of subwavelength surface grating over large surface area of molybdenum mirror by multiple irradiation of amplified femtosecond laser pulses from a homemade Ti:sapphire oscillator-amplifier laser system in a raster scan configuration. The laser system delivered 2 mJ, 80 fs duration laser pulses at a pulse repetition rate of 10 Hz. Various parameters such as pulse fluence, number of pulses, laser polarization, scan speed, and scan steps were optimized to obtain uniform subwavelength gratings. Energy dispersive x-ray spectroscopy measurements were conducted to analyze the elemental composition of mirror surfaces before and after laser treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

805 Stepped Plan Project Description

The 805 MHz system utilizes 1.25 MW class klystron amplifiers. The Solid-State Amplifier (SSA) technology has been utilized in the SC accelerator technology, but more powerful sources are needed for use in the NC accelerator facilities such as LASNCE. The SSA topologies that are widely used need to be scaled and tested for reliability and operation in a high impact accelerator facility, such as the 805 MHz SCCL in Los Alamos. Operational experience with high power SSA needs to be assessed prior to installation of an SSA unit at LANSCE. The RFE group at LANSCE is looking for collaboration in the development of the Solid-State Amplifier.

43 PARTICLE ACCELERATORS↗

Recent development of the Multi-Grid detector for large area neutron scattering instruments

Most of the Neutron Scattering facilities are committed in a continuous program of modernization of their instruments, requiring large area and high performance thermal neutron detectors. Beside scintillators detectors, {sup 3}He detectors, like linear PSDs (Position Sensitive Detectors) and MWPCs (Multi-Wires Proportional Chambers), are the most current techniques nowadays. Time Of Flight instruments are using {sup 3}He PSDs mounted side by side to cover tens of m{sup 2}. As a result of the so-called '{sup 3}He shortage crisis{sup ,} the volume of 3He which is needed to build one of these instruments is not accessible anymore. The development of alternative techniques requiring no 3He, has been given high priority to secure the future of neutron scattering instrumentation. This is particularly important in the context where the future ESS (European Spallation Source) will start its operation in 2019-2020. Improved scintillators represent one of the alternative techniques. Another one is the Multi-Grid introduced at the ILL in 2009. A Multi-Grid detector is composed of several independent modules of typically 0.8 m x 3 m sensitive area, mounted side by side in air or in a vacuum TOF chamber. One module is composed of segmented boron-lined proportional counters mounted in a gas vessel; the counters, of square section, are assembled with Aluminium grids electrically insulated and stacked together. This design provides two advantages: First, magnetron sputtering techniques can be used to coat B{sub 4}C films on planar substrates, and second, the neutron position along the anode wires can be measured by reading out individually the grid signals with fast shaping amplifiers followed by comparators. Unlike charge division localisation in linear PSDs, the individual readout of the grids allows operating the Multi-Grid at a low amplification gain, hence this detector is tolerant to mechanical defects and its production accessible to laboratories equipped with standard equipment. Prototypes of different configurations and sizes have been developed and tested. A demonstrator, with a sensitive area of 0.8 m x 3 m, has been studied during the CRISP European project; it contains 1024 grids, and a surface of isotopically enriched B{sub 4}C film close to 80 m{sup 2}. Its size represented a challenge in terms of fabrication and mounting of the detection elements. Another challenge was to make the gas chamber mechanically compatible with operation in a vacuum TOF chamber. Optimal working condition of this detector was achieved by flushing Ar-CO{sub 2} at a pressure of 50 mbar, and by applying 400 Volts on the anodes. This unusual gas pressure allows to greatly simplifying the mechanics of the gas vessel in vacuum. The detection efficiency has been measured with high precision for different film thicknesses. 52% has been measured at 2.5 Angstrom, in good agreement with the MC simulation. A high position resolution has been achieved by centre of gravity measurement of the TOT (Time-Over-Threshold) signals between neighbouring grids. These results, as well as other detection parameters, including gamma sensitivity and spatial uniformity, will be presented. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Communication Activities Through the Laser-Enhanced Mission Communications Navigation and Operational Services (LEMNOS) Office

The Laser-Enhanced Mission Communications Navigation and Operational Services (LEMNOS) office at Goddard Space Flight Center (GSFC) manages two NASA optical communication related projects, the Orion EM-2 Optical Communications Terminal (O2O) and the Integrated Laser Communications Relay Demonstration (LCRD) Low-Earth Orbit (LEO) User Modem and Amplifier Terminal (ILLUMA-T) projects. The main goal of LEMNOS project is to implement optical communications technologies on NASA missions starting with demonstrations of operational utility on Orion EM-2 and the International Space Station.

Seas, Antonios A.↗

On Compatible Transfer Operators in Nonsymmetric Algebraic Multigrid

The standard goal for an effective algebraic multigrid (AMG) algorithm is to develop relaxation and coarse-grid correction schemes that attenuate complementary error modes. In the nonsymmetric setting, coarse-grid correction Π will almost certainly be nonorthogonal (and divergent) in any known standard product, meaning ∥Π∥ > 1. This introduces a new consideration, that one wants coarse-grid correction to be as close to orthogonal as possible, in an appropriate norm. In addition, due to nonorthogonality, Π may actually amplify certain error modes that are in the range of interpolation. Relaxation must then not only be complementary to interpolation, but also rapidly eliminate any error amplified by the nonorthogonal correction, or the algorithm may diverge. Here this paper develops analytic formulae on how to construct “compatible” transfer operators in nonsymmetric AMG such that ∥Π∥ = 1 in some standard matrix-induced norm. Discussion is provided on different options for the norm in the nonsymmetric setting, the relation between “ideal” transfer operators in different norms, and insight into the convergence of nonsymmetric reduction-based AMG.

97 MATHEMATICS AND COMPUTING↗

Cryocooled terahertz photoconductive detector system with background-limited performance in 1.5–4 THz frequency range

We describe a 4-K-cryocooled dual-band terahertz (THz) photoconductive detector system with background-limited performance. The detector system comprises two THz photoconductive detectors covering a response in a wide frequency range from 1.5 to 4 THz, low noise amplifiers, optical low-pass filters to eliminate input radiation of higher frequencies, and a mechanical 4 K Gifford-McMahon refrigerator that provides practical and convenient operation without a liquid He container. The electrical and optical performances of the THz detector system were evaluated at a detector temperature of 4 K under 300 K background radiation. We proved that the detector system can achieve background-limited noise-equivalent-power on the order of 10{sup −14} W/Hz{sup 1/2} in the frequency range from 1.5 to 4 THz even if the vibration noise of the mechanical refrigerator is present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Induction-detection electron spin resonance with spin sensitivity of a few tens of spins

Electron spin resonance (ESR) is a spectroscopic method that addresses electrons in paramagnetic materials directly through their spin properties. ESR has many applications, ranging from semiconductor characterization to structural biology and even quantum computing. Although it is very powerful and informative, ESR traditionally suffers from low sensitivity, requiring many millions of spins to get a measureable signal with commercial systems using the Faraday induction-detection principle. In view of this disadvantage, significant efforts were made recently to develop alternative detection schemes based, for example, on force, optical, or electrical detection of spins, all of which can reach single electron spin sensitivity. This sensitivity, however, comes at the price of limited applicability and usefulness with regard to real scientific and technological issues facing modern ESR which are currently dealt with conventional induction-detection ESR on a daily basis. Here, we present the most sensitive experimental induction-detection ESR setup and results ever recorded that can detect the signal from just a few tens of spins. They were achieved thanks to the development of an ultra-miniature micrometer-sized microwave resonator that was operated at ∼34 GHz at cryogenic temperatures in conjunction with a unique cryogenically cooled low noise amplifier. The test sample used was isotopically enriched phosphorus-doped silicon, which is of significant relevance to spin-based quantum computing. The sensitivity was experimentally verified with the aid of a unique high-resolution ESR imaging approach. These results represent a paradigm shift with respect to the capabilities and possible applications of induction-detection-based ESR spectroscopy and imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of a time-resolved x-ray scattering instrument utilizing the full-repetition rate of x-ray pulses at the Pohang Light Source

We report on the development of a new experimental instrument for time-resolved x-ray scattering (TRXS) at the Pohang Light Source (PLS-II). It operates with a photon energy ranging from 5 to 18 keV. It is equipped with an amplified Ti:sappahire femtosecond laser, optical diagnostics, and laser beam delivery for pump-probe experiments. A high-speed single-element detector and high trigger-rate oscilloscope are used for rapid data acquisition. While this instrument is capable of measuring sub-nanosecond dynamics using standard laser pump/x-ray probe techniques, it also takes advantage of the dense 500 MHz standard fill pattern in the PLS-II storage ring to efficiently record nano-to-micro-second dynamics simultaneously. We demonstrate this capability by measuring both the (fast) impulsive strain and (slower) thermal recovery dynamics of a crystalline InSb sample following intense ultrafast laser excitation. Exploiting the full repetition rate of the storage ring results in a significant improvement in data collection rates compared to conventional bunch-tagging methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional simulation of the University of Hawai‘i FEL oscillator with cavity desynchronization

In this paper, we present three-dimensional, time-dependent simulations of the University of Hawai‘i (UH) at Mānoa free-electron laser (FEL) oscillator. Using beam parameters from the UH facility, we study the pass-by-pass evolution of the radiation field, including its temporal, spectral, and transverse properties. At nominal bunch length, the radiation pulse develops temporal spiking near saturation, together with sideband formation and increased sensitivity to machine timing jitter. Our results show that modest cavity desynchronization can enhance the radiation energy by 63%. Large cavity desynchronization, on the other hand, can effectively suppress the spiking instabilities and improve robustness to timing fluctuations. Finally, we simulate a short-bunch operational mode with a bunch length comparable to the slippage length, which accelerates saturation and further amplifies the FEL power. Overall, these results provide a quantitative foundation for pulse control studies in the UH FEL oscillator and a critical benchmark for future experimental validation and machine optimization.

free-electron lasers↗

High-repetition rate, CEP-stable shortwave infrared source with two-cycle pulses for field-resolved spectroscopy

We report on a passively carrier-envelope phase (CEP)-stable optical parametric amplifier generating two-cycle pulses at 2060 nm with energies of up to 2.25 µJ operating at a repetition rate of 400 kHz, specifically designed for applications in field-resolved spectroscopy. The measured pulse duration is 13.6 fs, resulting in two cycles of the carrier wave. Due to the robust CEP-stable front-end design, we achieve an open-loop CEP stability of 250 mrad (rms) and the capability for fast CEP modulation.

47 OTHER INSTRUMENTATION↗

Progress Towards RF Conditioning of Low-Loss Couplers for a Conduction-Cooled Cryomodule

This work presents current progress on the conditioning of two new 25 kW couplers optimized for use in a compact, conduction-cooled SRF cryomodule. A connecting waveguide, previously used for conditioning the 805 MHz SNS couplers, was altered for use at 915 MHz. The necessary modifications were determined via RF modeling, while thermal analysis results identified additional cooling requirements during RF conditioning and provided insight about potential higher-power operation. Initial low-power conditioning will be performed with a 2.5 kW solid-state amplifier, with plans to use an industrial magnetron for RF conditioning at 25 kW in the near future.

Stilin, N. [Thomas Jefferson National Accelerator ↗

PROGRESS TOWARDS RF CONDITIONING OF LOW-LOSS COUPLERS FOR A CONDUCTION-COOLED CRYOMODULE

This work presents current progress on the conditioning of two new 25 kW couplers optimized for use in a compact, conduction-cooled SRF cryomodule. A connecting waveguide, previously used for conditioning the 805 MHz SNS couplers, was altered for use at 915 MHz. The necessary modifications were determined via RF modeling, while thermal analysis results identified additional cooling requirements during RF conditioning and provided insight about potential higher-power operation. Initial low-power conditioning will be performed with a 2.5 kW solid-state amplifier, with plans to use an industrial magnetron for RF conditioning at 25 kW in the near future.

Wilson, Christiana [Thomas Jefferson National Acce↗

Pyrotechnic shock measurement and data analysis requirements

An investigation is described into the laboratory measurement and analysis of pyrotechnic shock which was prompted at JPL when two separate facilities generated discrepant pyrotechnic shock data while testing Mariner Jupiter/Saturn 1977 spacecraft hardware. Both of the testing facilities were surveyed. The only difference noted was in the FM tape recorders used to record the data. One facility used a tape recorder operating at 60 in./sec with a frequency response of 20 kHz; the other used a tape recorder operating at 120 in./sec with a frequency response of 80 kHz. The accelerometers, cables, charge amplifiers, and mechanical setups were identical.

Albers, L.↗

The Viking seismometer

The Viking seismometer, operating on the Martian surface in the region of Utopia Planitia, includes three inertial velocity transducers, amplifiers, filters, automatic event detectors, data compactors, and temporary data storage capability within a unit weighing 2.2 kg. The seismometer functions at a peak magnification of 218,000 with a ground resolution of 2 nanosec and 3 Hz. Since the telemetry capacities associated with the system are limited, the seismometer instrument package employs three data processing modes: a high sampling rate mode; a heavily filtered background monitoring mode; and a frequently-used data compacting mode.

Miller, W. F.↗

High sensitivity operation of discrete solid state detectors of 4 K

Techniques are described to allow operation of discrete solid state detectors at 4 K with optimized junction field effect transistor (JFET) amplifiers. Three detector types cover the 0.6-4 micron spectral range with a noise equivalent power (NEP) of approximately 10 to the -16th per sq rt Hz for two of the types and potential improvement to this performance for the third. Lower NEPs can be anticipated at longer IR wavelengths.

Rieke, G. H.↗

High power singlemode edge-emitting master oscillator power amplifier

An edge-emitting monolithically integrated master oscillator power amplifier (M-MOPA) has been fabricated by integrating a distributed Bragg reflector laser with a 500 microns long single mode amplifier. The M-MOPA contains a strained InGaAs quantum well in the active region and operates at about 981.5 nm in an edge-emitting fashion with maximum powers in excess of 175 mW. Single longitudinal and transverse mode operation is maintained to powers in excess of 110 mW CW.

O'Brien, S.↗