Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid stabilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Research Trends and Applications of PMUs

This work is a survey of current trends in applications of PMUs. PMUs have the potential to solve major problems in the areas of power system estimation, protection, and stability. A variety of methods are being used for these purposes, including statistical techniques, mathematical transformations, probability, and AI. The results produced by the techniques reviewed in this work are promising, but there is work to be performed in the context of implementation and standardization. As the smart grid initiative continues to advance, the number of intelligent devices monitoring the power grid continues to increase. PMUs are at the center of this initiative, and as a result, each year more PMUs are deployed across the grid. Since their introduction, myriad solutions based on PMU-technology have been suggested. The high sampling rates and synchronized measurements provided by PMUs are expected to drive significant advancements across multiple fields, such as the protection, estimation, and control of the power grid. This work offers a review of contemporary research trends and applications of PMU technology. Most solutions presented in this work were published in the last five years, and techniques showing potential for significant impact are highlighted in greater detail. Being a relatively new technology, there are several issues that must be addressed before PMU-based solutions can be successfully implemented. This survey found that key areas where improvements are needed include the establishment of PMU-observability, data processing algorithms, the handling of heterogeneous sampling rates, and the minimization of the investment in infrastructure for PMU communication. Solutions based on Bayesian estimation, as well as those having a distributed architectures, show great promise. The material presented in this document is tailored to both new researchers entering this field and experienced researchers wishing to become acquainted with emerging trends.

42 ENGINEERING↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Three-dimensional direct numerical simulation of a turbulent lifted hydrogen jet flame in heated coflow: flame stabilization and structure

Direct numerical simulation (DNS) of the near field of a three-dimensional spatially developing turbulent lifted hydrogen jet flame in heated coflow is performed with a detailed mechanism to determine the stabilization mechanism and the flame structure. The DNS was performed at a jet Reynolds number of 11,000 with over 940 million grid points. The results show that auto-ignition in a fuel-lean mixture at the flame base is the main source of stabilization of the lifted jet flame. A chemical flux analysis shows the occurrence of near-isothermal chemical chain branching preceding thermal runaway upstream of the stabilization point, indicative of hydrogen auto-ignition in the second limit. The Damköhler number and key intermediate-species behaviour near the leading edge of the lifted flame also verify that auto-ignition occurs at the flame base. At the lifted-flame base, it is found that heat release occurs predominantly through ignition in which the gradients of reactants are opposed. Downstream of the flame base, both rich-premixed and non-premixed flames develop and coexist with auto-ignition. In addition to auto-ignition, Lagrangian tracking of the flame base reveals the passage of large-scale flow structures and their correlation with the fluctuations of the flame base. In particular, the relative position of the flame base and the coherent flow structure induces a cyclic motion of the flame base in the transverse and axial directions about a mean lift-off height. This is confirmed by Lagrangian tracking of key scalars, heat release rate and velocity at the stabilization point.

Mechanics↗

Robust Stabilization of Inverter-Based Resources Using Virtual Resistance-Based Control

This letter proposes a virtual resistance-based nonlinear control to stabilize and robustify the current layer of inverter-based resources, subject to the grid voltage disturbances, and the grid parameter uncertainties. A class of virtual resistances is proposed and analyzed using concepts from dissipative systems theory. Moreover, specific nonlinear virtual resistance-based controllers are derived, with their corresponding performance analytically bounded. Here, the theoretical and simulation results show that the proposed nonlinear virtual resistance-based controllers significantly reduce the L 2 gain of the closed-loop error system to grid voltage variation and parametric uncertainties. Significant improvements of the transient and steady-state current responses are also demonstrated over linear virtual resistance counterparts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Forced Oscillation Grid Vulnerability Analysis and Mitigation Using Inverter-Based Resources: Texas Grid Case Study

Forced oscillation events have become a challenging problem with the increasing penetration of renewable and other inverter-based resources (IBRs), especially when the forced oscillation frequency coincides with the dominant natural oscillation frequency. A severe forced oscillation event can deteriorate power system dynamic stability, damage equipment, and limit power transfer capability. This paper proposes a two-dimension scanning forced oscillation grid vulnerability analysis method to identify areas/zones in the system that are critical to forced oscillation. These critical areas/zones can be further considered as effective actuator locations for the deployment of forced oscillation damping controllers. Additionally, active power modulation control through IBRs is also proposed to reduce the forced oscillation impact on the entire grid. The proposed methods are demonstrated through a case study on a synthetic Texas power system model. The simulation results demonstrate that the critical areas/zones of forced oscillation are related to the areas that highly participate in the natural oscillations and the proposed oscillation damping controller through IBRs can effectively reduce the forced oscillation impact in the entire system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables: Preprint

This paper performs a transient stability study of a real-world microgrid with 100% renewables to fully understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, the full-scale electromagnetic transient modeling of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid, which gives good references for the field deployment in terms of inverter configuration and coordination as well as the capabilities of black start and unplanned islanding.

100% renewable microgrid↗

Factors that Influence the Formation and Stability of Thin, Cryo-EM Specimens

Poor consistency of the ice thickness from one area of a cryo-electron microscope (cryo-EM) specimen grid to another, from one grid to the next, and from one type of specimen to another, motivates a reconsideration of how to best prepare suitably thin specimens. We first review the three related topics of wetting, thinning, and stability against dewetting of aqueous films spread over a hydrophilic substrate. Furthermore, we then suggest that the importance of there being a surfactant monolayer at the air-water interface of thin, cryo-EM specimens has been largely underappreciated. In fact, a surfactant layer (of uncontrolled composition and surface pressure) can hardly be avoided during standard cryo-EM specimen preparation. Thus it is suggested that better control over the composition and properties of the surfactant layer may result in more reliable production of cryo-EM specimens with the desired thickness.

59 BASIC BIOLOGICAL SCIENCES↗

An Open-Source Parallel EMT Simulation Framework

As the integration level of inverter-based resources (IBRs) increases, ensuring the reliable operation of the bulk power systems requires the use of electromagnetic transient (EMT) simulation tools to identify and mitigate system-wide stability risks. Conducting EMT studies for large-scale, IBR-rich grids, however, is challenging due to the inherent computational bottleneck caused by the underlying high-fidelity models and required small time steps. This paper introduces ParaEMT: an open-source, generic EMT simulation framework designed to accelerate simulations by leveraging advanced parallel computational technologies, such as high-performance computers. This paper presents a comprehensive exposition of ParaEMT, covering its modeling library, simulation strategy, framework structure, operational procedures, and auxiliary features, alongside its extensible parallel computational architecture. Notably, ParaEMT is a publicly accessible and modularized framework written in Python, thereby facilitating future development and the integration of new models and algorithms. The accuracy and efficiency of ParaEMT are demonstrated by rigorous validations via multiple case studies.

electromagnetic transient simulation↗

Large-Signal Impedance Modeling of Three-Phase Voltage Source Converters

Resonance problems have become a major hurdle in the large-scale grid integration of renewable energy. It is important to be able to predict the amplitude of resonance-induced distortions for the protection and control design of power electronic converters. We recently presented an impedance-based approach for the prediction of resonance amplitude. It was shown that the impedance response of a converter starts changing with the amplitude of resonance; this blocks the amplitude growth beyond a certain point where the converter forms a limit cycle mode of sustained oscillations. The large-signal impedance of a converter captures the change in its impedance response with the resonance amplitude, and it can be used to predict the resonance amplitude under different operation conditions. This paper presents large-signal sequence impedance modeling for three-phase voltage source converters (VSC) with dq-current control and PLL. Modeling challenges encountered in the absence of the small-signal approximation are addressed by a) leveraging the dominating influence of hard nonlinearities such as pulse-width modulation saturation and limiters over soft nonlinearities in shaping the converter large-signal behavior and b) modeling the large-signal gain of hard nonlinearities using appropriate describing functions. Developed large-signal impedance models are validated using numerical simulations. Measurements of the large-signal impedance responses of a commercial 1-MW VSC-based inverter are also presented to experimentally demonstrate the effects of the injected perturbation amplitude on impedance response as predicted by the developed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Forming Inverters: Project Demonstrations and Pilots

Power system operators around the world are pushing the limits of integrating inverter-based resources (IBRs) to very high levels, approaching 100% instantaneous penetration under certain operating conditions. This often applies to smaller power systems with very little or no ac interconnections to other neighboring regions or sometimes to fringes of large balancing areas, such as Denmark or Portugal, within the mainland European power system. These jurisdictions have identified the potential of grid-forming (GFM) technology as a key enabler to support the energy transition with very few or no synchronous generators online. Until recently, practical applications of GFM inverters were limited to microgrids and isolated grids and in smaller grid applications on the order of a few tens of megawatts (MW).

Australia↗

Adaptive Load Shedding for Grid Emergency Control via Deep Reinforcement Learning

Emergency control, typically such as under-voltage load shedding (UVLS), is broadly used to grapple with low voltage and voltage instability issues in real-world power systems under contingencies. However, existing emergency control schemes are rule-based and cannot be adaptively applied to uncertain and floating operating conditions. Here, we propose an adaptive UVLS algorithm for emergency control via deep reinforcement learning (DRL) and expert systems. We first construct dynamic components for picturing the power system operation as the environment. The transient voltage recovery criteria, which poses time-varying requirements to UVLS, is integrated into the states and reward function to advise the learning of deep neural networks. The proposed method has no tuning issue of coefficients in reward functions, and this issue was regarded as a deficiency in the existing DRL-based algorithms. Case studies illustrate that the proposed method outperforms the traditional UVLS relay in both the timeliness and efficacy for emergency control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. GFM inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generators) and follow the change in the load demand; however, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help grid operators better manage their inverter-based resources (IBRs) to improve operation efficiency and reliability; therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and synchronous generators) to output the target power in both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters.

dispatching↗

TISCC: A Surface Code Compiler and Resource Estimator for Trapped-Ion Processors

We introduce the Trapped-Ion Surface Code Compiler (TISCC), a software tool that generates circuits for a universal set of surface code patch operations in terms of a native trapped-ion gate set. To accomplish this, TISCC manages an internal representation of a trapped-ion system where a repeating pattern of trapping zones and junctions is arranged in an arbitrarily large rectangular grid. Surface code operations are compiled by instantiating surface code patches on the grid and using methods to generate transversal operations over data qubits, rounds of error correction over stabilizer plaquettes, and/or lattice surgery operations between neighboring patches. Beyond the implementation of a basic surface code instruction set, TISCC contains corner movement functionality and a patch translation that is implemented using ion movement alone. Except in the latter case, all TISCC functionality is extensible to alternative grid-like hardware architectures. TISCC output has been verified using the Oak Ridge Quasi-Clifford Simulator (ORQCS).

LeBlond, Tyler↗

ORNL-QCI/TISCC

We introduce the Trapped-Ion Surface Code Compiler (TISCC), a software tool that generates circuits for a universal set of surface code patch operations in terms of a native trapped-ion gate set. To accomplish this, TISCC manages an internal representation of a trapped-ion system where a repeating pattern of trapping zones and junctions is arranged in an arbitrarily large rectangular grid. Surface code operations are compiled by instantiating surface code patches on the grid and using methods to generate transversal operations over data qubits, rounds of error correction over stabilizer plaquettes, and/or lattice surgery operations between neighboring patches. Beyond the implementation of a basic surface code instruction set, TISCC contains corner movement functionality and a patch translation that is implemented using ion movement alone. Except in the latter case, all TISCC functionality is extensible to alternative grid-like hardware architectures. TISCC output has been verified using the Oak Ridge Quasi-Clifford Simulator (ORQCS).

LeBlond, Tyler↗

A Statistical Evaluation of WRF-LES Trace Gas Dispersion Using Project Prairie Grass Measurements

In recent years, new measurement systems have been deployed to monitor and quantify methane emissions from the natural gas sector. Large-eddy simulation (LES) has complemented measurement campaigns by serving as a controlled environment in which to study plume dynamics and sampling strategies. However, with few comparisons with controlled-release experiments, the accuracy of LES for modeling natural gas emissions is poorly characterized. In this paper, we evaluate LES from the Weather Research and Forecasting (WRF) Model against Project Prairie Grass campaign measurements and surface layer similarity theory. Using WRF-LES, we simulate continuous emissions from 30 near-surface trace gas sources in two stability regimes: strong convection and weak convection. We examine the impact of grid resolutions ranging from 6.25 to 52 m in the horizontal dimension on model results. We evaluate performance in a statistical framework, calculating fractional bias and conducting Welch’s t tests. WRF-LES accurately simulates observed surface concentrations at 100 m and beyond under strong convection; simulated concentrations pass t tests in this region irrespective of grid resolution. However, in weakly convective conditions with strong winds, WRF-LES substantially overpredicts concentrations—the magnitude of fractional bias often exceeds 30%, and all but one t test fails. The good performance of WRF-LES under strong convection correlates with agreement with local free convection theory and a minimal amount of parameterized turbulent kinetic energy. The poor performance under weak convection corresponds to misalignment with Monin–Obukhov similarity theory and a significant amount of parameterized turbulent kinetic energy.

17 WIND ENERGY↗

Operational and Strategic Implementation of Dynamic Line Rating for Optimized Wind Energy Generation Integration

One primary goal of rendering today’s transmission grid “smarter” is to optimize and better manage its power transfer capacity in real time. Power transfer capacity is affected by three main elements: stability, voltage limits, and thermal ratings. All three are critical, but thermal ratings represent the greatest opportunity to quickly, reliably and economically utilize the grid’s true capacity. With the “Smarter Grid”, new solutions have been sought to give operators a better grasp on real time conditions, allowing them to manage and extend the usefulness of existing transmission infrastructure in a safe and reliable manner. The objective of the INL Wind Program is to provide industry a Dynamic Line Rating (DLR) solution that is state of the art as measured by cost, accuracy and dependability, to enable human operators to make informed decisions and take appropriate actions without human or system overloading and impacting the reliability of the grid. In addition to mitigating transmission line congestion to better integrate wind, DLR also offers the opportunity to improve the grid with optimized utilization of transmission lines to relieve congestion in general. As wind-generated energy has become a bigger part of the nation’s energy portfolio, researchers have learned that wind not only turns turbine blades to generate electricity, but can cool transmission lines and increase transfer capabilities significantly, sometimes up to 60 percent. INL’s DLR development supports EERE and The Wind Energy Technology Office’s goals by informing system planners and grid operators of available transmission capacity, beyond typical Static Line Ratings (SLR). SLRs are based on a fixed set of conservative environmental conditions to establish a limit on the amount of current lines can safely carry without overheating. Using commercially available weather monitors mounted on industry informed custom brackets developed by INL in combination with Computational Fluid Dynamics (CFD) enhanced weather analysis and DLR software, INL’s project offers the potential of safely providing line ampacities up to 40 percent or more above existing SLRs, by using real time information rather than overly conservative SLR.

17 WIND ENERGY↗