Search NASASearch

SEARCH · Search NASA

Results for “17 WIND ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

312 records · Page 5

High Temperature Dielectric Properties and Differential Scanning Calorimetry of Lunar Simulants

To guide development of microwave process technology that could be used during in situ construction on the Moon, we measured the high-temperature basic dielectric properties (εʹ and εʺ) of 17 lunar simulants and related materials. In order to confidently use these data one needs to understand the data’s strengths and weaknesses. Therefore, a goal of this publication is to provide insights into the comparative effects of sample composition, pre-treatments, experimental variables, high temperatures, and other factors on the measured response. The dielectric measurements were performed using the cavity perturbation method over a temperature range between room temperature to 1000 °C, or higher, and provided the real and imaginary components of permittivity at six frequencies. The utility of the original values was limited by the varying density of the pellets used in the measurement. Therefore, all of the εʹ and εʺ measurements at the frequency of 2466 MHz have been scaled to a constant density, 1.75 g/cm 3 . Here the data are presented as graphs chosen to aid analysis within and across simulant groups. To gain additional insight into the processes happening at the elevated temperatures in the dielectric measurements, heat capacity data was obtained using differential scanning calorimetry (DSC) on several of the simulant materials. Our data show that over the frequency range 397 MHz – 2985 MHz a material’s behavior does not greatly change, as compared to the scale of differences observed between lunar mare and highland simulants at high temperatures. For example at 1000 °C, the mare simulant JSC-1A absorbs 10 times more power than the highland simulant NUW-LHT-5M. We observe that as melting temperatures are reached both permittivity and dielectric loss rise non-linearly, helping to explain thermal runaway during microware heating. Our data show that even less than a few weight % of many non-lunar minerals, and the use of mixtures in simulants can affect the dielectric behavior at higher temperatures. A comparison of our results with published dielectric data for Apollo samples and with remote sensing of the Moon supports the conclusion the simulants and lunar material at room temperature have very similar dielectric values.

Differential Scanning Calorimetry

Reliability Models and Demonstration of a Fault-Tolerant Motor Concept for Vertical Takeoff and Landing Vehicles

This report documents the completion of the Revolutionary Vertical Lift Technology Project Annual Performance Indicator 24-3.2.4.1: “Apply and document reliability prediction for high reliability motor concept.” Two modeling tools were completed for calculation of reliability of fault-tolerant (FT) motors, and key FT operations of a modular FT motor were demonstrated experimentally. The two models are complementary tools for the stakeholder and user community. Both models employ Markov chain theory. The first model is a time-homogeneous Markov chain model, and the second is a time-inhomogeneous Markov-Weibull model. This report’s main sections are as follows: 1.0 Introduction, 2.0 Theory, 3.0 Motor Reliability Models, 4.0 Validation of FT Operation by Hardware Demonstration, and 5.0 Concluding Remarks. Novel contributions to the field include development of a modular FT motor concept for electrified vertical takeoff and landing (eVTOL) application, solution methods to solve the reliability calculations, development of figures of merit, and the introduction of “linked chains” to formulate a building-block approach for time-inhomogeneous Markov-Weibull modeling of motor reliability. Example case studies have been completed, and results are provided and discussed herein. A four-module FT motor concept was developed to a preliminary-design level of detail. This eVTOL FT motor concept was designed for galvanic, magnetic, and thermal isolation of stator winding faults. The reliability of the concept motor was calculated using a time-inhomogeneous Markov chain model. Employing average failure rate as a metric, 570 times greater reliability was achieved as compared to a baseline motor without fault tolerance. A demonstrator motor was built and tested. The testing demonstrated the key features of FT operation and validated the essential premises of the FT motor concepts presented herein. The experiments included successful demonstration of the feasibility of the following four key FT features: (1) terminal open-circuit operation, (2) thermal isolation after fault, (3) terminal short-circuit operation, and (4) internal short-circuit operation. These works indicate that FT modular motor drives offer promise for addressing the daunting reliability gap that electric aircraft propulsor drives are facing relative to the best conventional motor drive technology that is available today.

Electric Motor

Hellas, Ken and Me: Adventures in Exhumation and Inundation

Hellas is the largest and deepest basin on Mars. A 1993 study by Moore and Edgett (GRL, 20, 1599-1602) noted that Hellas undergoes net dust erosion. Thus, the exposed surface must represent whatever lag or rock surface and could not be removed by the strong winds blowing at these low elevations. The particle size distributions and particularly the rock or boulder population in this lag was thought to be potentially useful for distinguishing between processes that formed the lithologic units that comprise Hellas Planitia. Earlier studies had suggested the Hellas floor might be paved with basalt or glacial deposits. Ken, who at the time was working with Viking Orbiter IRTM data knew that there were late mission observations of the Hellas floor acquired though clear skies. His derived thermal inertia from these observations strongly suggested that the abundance of particles larger than coarse sand was very low. Hence, our study concluded that the floor deposits were, among other possibilities, ancient loess or lacustrine deposits. In 2001 a subsequent study on the Hellas basin by Moore and Wilhelms (Icarus, 54, 258-276) proposed that the basin was once a site of an ice covered sea, based on a series of circum-basin scarps that follow constant elevations as well as other landforms seen my Mars Global Surveyor’s MOC (an instrument that Ken played a major role in daily operations and data analysis) and topography derived from MOLA. Subsequently the best contiguous observations of the Hellas basin have been acquired from the Mars Reconnaissance Orbiter’s Context Camera, which again Ken has been a central player in its operations. Much of what we know about the grain-scale sedimentology of martian lacustrine deposits comes from the Curiosity Rover’s Mars Hand Lens Imager (which Ken was the PI through development and original operations within Gale crater). Under Ken’s watch several members of the Murray Formation were determined to be deposited in a lacustrine environment. A conclusion strongly demonstrated by MHLI imaging. My personal relationship with Hellas isn’t over. The Europa Clipper flew directly over the Hellas basin including its deepest regions. Ther REASON Ice Penetrating Radar system collected data during this flyby ostensibly for calibration, yet the quality of the observations may yet provide new discoveries from Hellas.

Jeffrey M Moore

First N 2 Profile for Venus’ Deep Lower Atmosphere

We present the first N 2 profile for Venus’ deep lower atmosphere (<15 km) and a constrained isotopic composition for cloud N 2 [1]. This work directly addresses unresolved questions for Venus using legacy observations. Prior to this work, there were no reported measurements for N 2 abundances at <15 km and the isotopic composition remained unconstrained [2]. The N 2 parameters are critical to understanding the evolution and thermal properties of the atmosphere [3-7]. Our N 2 results were obtained by re-analysis of data acquired in 1978 by the Pioneer Venus Large Probe Neutral Mass Spectrometer (LNMS) [8]. The archived mass spectra from 64.2 to 0.2 km were treated using the analytical procedures specifically developed for the LNMS [9-11]. Judicious peak fitting permitted disambiguation of (A) N 2 + and CO + at 28 u and (B) 14 N 15 N+, 13 CO + , and C 2 H 5 + at 29 u. Quality controls included comparing the (A) LNMS CO + /CO 2 + ratios to the NIST database and literature and (B) fitted counts for CO + to the expected counts of CO + calculated from C 18 O + and 13 CO + using the LNMS 16 O/ 18 O and 12 C/ 13 C ratios (obtained from CO 2 ). Our results show that N 2 is uniformly mixed across the deep lower atmosphere between ~0.2 and 15 km (2.49 ± 0.10 v%). In contrast, N 2 is non-uniformly mixed across the sub-cloud atmosphere and clouds (~15–59 km), where N 2 abundances increase by ~ 2-fold between ~15 km (2.45 ± 0.32 v%) and ~59-51 km (5.21 ± 0.18 v%). Using the cloud data, we also obtained a constrained 15 N/ 14 N ratio (2.93×10 -3 ± 0.13×10 -3 ) and δ 15 N value (-204 ± 35‰). Thus, the LNMS results [1] suggest that (A) the atmosphere is unstable at <15 km, (B) N 2 is not well-mixed >15 km, and (C) the cloud δ 15 N falls between Earth and the solar wind [12, 13]. Comparisons of the N 2 abundances and isotopic compositions for nitrogen, carbon, and oxygen to other Venus measurements will be discussed.

deep lower atmosphere

Using Open Innovation in Reducing Risk to Crews

In the exploration of destinations outside of Earth's neighborhood, specifically Mars, scientific and engineering inquiries have occurred by two means; observations from satellites and observations by landed spacecraft. Satellite observations (Mariner, MRO, Mars Odyssey, provide global-scale spatial and temporal data while landed spacecraft (Viking, Mars Pathfinder, Spirit, Opportunity, Phoenix Mars Lander) investigate highly localized areas of the surface of the planet. In preparation for human exploration, extensive knowledge of the surface and atmospheric environments should be known before the first human leaves Earth. The primary goal of performing reconnaissance on Mars on a sub-global scale is to know as much as possible about the environment to which crews will be subjected. At the current rate of launching and landing probes to Mars, it will take a very long time to understand the surface and atmospheric conditions associated with the regions where prospective crews may land. Meanwhile electronics and electrical systems are rapidly getting smaller. One can argue that to acquire the knowledge of the region, one must take hundreds, maybe thousands of measurements simultaneously. One means to perform such a task is to deploy a swarm of sensors. Such a swarm would perform an in-situ assessment of the region. Imagine a close flyby mission to Mars for example, where mini- to micro-sensors are deposited into the atmosphere over half an orbit or more. The sensors, captured by the atmospheric drag and Martian gravity slowly descend buffeted about by Martian winds and weather until they settle on the surface a great time later (think of how long dust takes to settle). As they descend they communicate a vast array of data; temperature, chemistry, pressure, radiation dose, electric or magnetic properties from a region of the planet and an individual sensor need not measure the same quantity as its neighbors. Initially, they could move at the whim of the environment but later versions could have locomotion or propulsion mechanisms. Humans wouldn't need to decide where the sensors go, the sensors do that for themselves. This is a key strength of a sensor swarm. The intelligence relies on the group not on a decision maker on earth. Real time sensor inputs direct what the swarm considers most interesting to investigate resulting in emergent behavior. We issued a $20,000 challenge to the global innovators to provide solutions as to how such a swarm could be initialized and by what protocols and methodologies by which they operate. Over 400 innovators from 49 countries took a look at the problem, with three receiving partial awards for solutions.

Mel Ferebee

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

RTV

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

silicone intumescence

Adaptive Curation at NASA Johnson Space Center: Preparing for Artemis Samples by Leveraging Proven Practices and Innovative Solution

The proper curation of returned astromaterial samples is essential to ensure that high-quality scientific investigations can be conducted for decades, enabling future generations to address evolving research questions. The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is responsible for curating all of NASA’s extraterrestrial samples. Under the governing document, NASA Procedural Requirement (NPR) 7100.5 “Curation of Extraterrestrial Materials”, JSC Curation is charged with “The curation of all extraterrestrial material under NASA control, including future NASA missions.” The Directive goes on to define Curation as including “...documentation, preservation, preparation, and distribution of samples for research, education, and public outreach.” JSC Curation has a long-standing legacy of curating extraterrestrial materials, including but not limited to Apollo and Luna lunar samples, Genesis solar wind samples, Stardust comet samples, asteroid samples (Hayabusa1, Hayabusa2, and OSIRIS-REx), and Antarctic Meteorite samples from a variety of parent bodies. Building on this foundation, the Artemis program introduces new challenges and opportunities for sample curation, requiring both the application of proven practices and the development of innovative solutions. The Artemis Collection will be curated using established protocols refined through decades of experience with Apollo and subsequent sample collections, including but not limited to the utilization of cleanrooms, custom nitrogen gloveboxes, specialized storage containers and tools; all of which have strict material utilization and prohibition requirements. These practices provide a robust framework for contamination control, documentation, and long-term preservation. However, Artemis samples may present unique scientific and operational requirements, including enhanced contamination control measures (relative to Apollo) driven by evolving science objectives. To meet these needs, JSC Curation is actively developing new technologies and protocols that extend beyond traditional approaches, ensuring that the integrity of samples is maintained under increasingly stringent standards. One critical area of innovation is the development of cold sample curation capabilities. Certain Artemis samples, particularly those from Permanently Shadowed Regions (PSRs) and cold environments, are expected to contain ices and volatile components that require preservation and handling at sub-zero or even cryogenic temperatures. JSC Curation is leveraging best practices from the cold and cryogenic sample industries, as well as other government agencies and academic experts, to design facilities and handling procedures that maintain sample integrity while enabling scientific access. The goal is to develop capabilities to allow researchers to investigate volatiles and other temperature-sensitive materials while minimizing chemical and physical alterations from their returned state. In summary, adaptive curation at JSC combines the reliability of proven methodologies with forward-looking innovations to meet the scientific and operational demands of Artemis. Through enhanced contamination control, advanced cold curation capabilities, and an understanding of known and evolving future science priorities, NASA is preparing to maximize the scientific return from Artemis samples and preserve their value for generations of researchers.

Andrea D Harrington

Erosion Results of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4)

Polymers and other oxidizable materials on the exterior of spacecraft in the low Earth orbit (LEO) space environment can be eroded from reaction with atomic oxygen (AO). Therefore, in order to design durable spacecraft it is important to know the extent of erosion that will occur during a mission. This can be determined by knowing the LEO AO erosion yield, E y (volume loss per incident oxygen atom), of materials susceptible to AO reaction. In addition, recent flight experiments have shown that the AO E y can vary with the AO fluence and/or solar exposure. Therefore, obtaining AO E y data for materials flown on various spaceflight missions is important. NASA Glenn Research Center has flown numerous experiments as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS) to characterize the LEO E y of polymers, composites, protective coatings, and other spacecraft materials. Recently, four Glenn experiments with 365 flight (F) samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Although each experiment had numerous sample objectives, the primary objective was to determine the LEO AO E y of various spacecraft materials as a function of solar irradiation and AO fluence. This paper provides a summary of the erosion data for the PCE 1-4 AO E y samples. The AO E y for 150 samples flown in either the LEO ram, wake, zenith or nadir directions are provided. The AO ram fluence varied from 2.97×10 20 atoms/cm 2 after 0.89 years of direct space exposure (with relatively high levels of Si contamination) on MISSE 12 to 3.93×10 20 atoms/cm 2 after 1.17 years of direct space exposure on MISSE-10. The ram AO E y values for uncoated polymers range from 3.81×10 –25 cm 3 /atom for polytetrafluoroethylene (M9R-C20 F) exposed to an AO fluence of 3.44×10 20 atoms/cm 2 on MISSE-9 to 4.43×10 –23 cm 3 /atom for AO etched low density polyimide aerogel (M12R-C21 F) exposed to an AO fluence of 2.97×10 21 atoms/cm 2 on MISSE-12. Because of the low AO fluence and relatively high Si contamination, a number of PCE-3 wake samples experienced mass gain. Thus, AO E y values are not provided for these samples. Although there are calculated AO E y values for the zenith, wake and nadir samples, the ram AO E y for a particular material is a more reliable value in terms of AO exposure because the zenith, wake and nadir directions were exposed to either no or very little AO fluence and thus other space environmental factors (i.e. vacuum, thermal extremes and thermal cycling, and/or various types of radiation) are responsible for the mass loss.

Erosion yield

Some Experiments on the Passage of High-Energy Protons in Dense Matter

A series of experiments designed to study the nuclear cascade resulting from the passage of 1 to 3 GeV protons in matter has been in progress at the Brookhaven Cosmotron. Preliminary results on the fluxes of fast neutrons (upper limits) and of strongly interacting particles above 50 MeV are summarized here (Fig. 1 and Table 1). The four cases studied are: 1-GeV protons on Fe, on chondritic material, and on C 5 H 8 O 2 , and 3-GeV protons on Fe.

Proton Irradiation