Raman enhancement induced by exciton hybridization in molecules and 2D materials

Abstract Surface-enhanced Raman spectroscopy (SERS) is a powerful technique for trace-level fingerprinting. Recently, layered two-dimensional (2D) materials have gained significant interest as SERS substrates for providing stable, uniform, and reproducible Raman enhancement with the potential for trace-level detection. Yet, the development of effective 2D SERS substrates is still hindered by the lack of fundamental understanding of the coupling mechanism between target molecules and substrates. Here, we report a systematic excitation-dependent Raman spectroscopy investigation on the coupling between 2D materials such as SnS 2 , MoS 2 , WSe 2 , and graphene and small organic molecules like rhodamine 6G (Rh 6G). Strong coupling between SnS 2 and Rh 6G is found due to their degenerate excitons through Raman excitation profiles (REP), leading to the enhancement of Rh 6G vibrational modes that are observable down to 10 −13 M. Our study shows that exciton coupling in the substrate-adsorbate complex plays a vital role in the Raman enhancement effect, opening a new route for designing SERS substrates for high sensitivity.

Materials Science

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION

RadioGalaxyNET: Dataset and novel computer vision algorithms for the detection of extended radio galaxies and infrared hosts

Abstract Creating radio galaxy catalogues from next-generation deep surveys requires automated identification of associated components of extended sources and their corresponding infrared hosts. In this paper, we introduce RadioGalaxyNET, a multimodal dataset, and a suite of novel computer vision algorithms designed to automate the detection and localization of multi-component extended radio galaxies and their corresponding infrared hosts. The dataset comprises 4 155 instances of galaxies in 2 800 images with both radio and infrared channels. Each instance provides information about the extended radio galaxy class, its corresponding bounding box encompassing all components, the pixel-level segmentation mask, and the keypoint position of its corresponding infrared host galaxy. RadioGalaxyNET is the first dataset to include images from the highly sensitive Australian Square Kilometre Array Pathfinder (ASKAP) radio telescope, corresponding infrared images, and instance-level annotations for galaxy detection. We benchmark several object detection algorithms on the dataset and propose a novel multimodal approach to simultaneously detect radio galaxies and the positions of infrared hosts.

Astronomy & Astrophysics

Theoretical design and performance of three-dimensional, pillared FeS 2 cathodes

Three-dimensional (3D) electrode design can provide improved capacities and rate capabilities over conventional two-dimensional electrodes by enhancing electrical and ionic transport. Here, expanding upon our previous modeling efforts for conversion chemistry lithium-ion batteries, we develop a pseudo-four-dimensional (P4D) approach that is subsequently used to investigate the design of a pillared FeS 2 electrode. The model considers transport in three dimensions with an additional “fourth” dimension corresponding to the solid-state lithium transport within the active material particles. Additionally, we allow for expansion of the active material during the conversion reaction to understand how internal stresses impact the electrochemical performance of the cell. By optimizing the model with respect to areal capacity, we are able to predict areal capacities up to 16.8 mAh/cm 2 for an areal current density of 1.78 mA/cm 2 and a 103% improvement for the three-dimensional electrodes over planar electrodes of equal volume. Despite the promising results, our simulations suggest that 3D design may be difficult for conversion cathode materials due to the large internal stresses that arise during conversion. Nevertheless, the model is robust and adaptable to other materials that may be more suitable for 3D electrodes due to a lesser change in volume during discharge.

Conversion cathode materials

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Change Detection Analysis in Urban and Suburban Areas Using Landsat Thematic Mapper data: Case of Huntsville, Alabama

Two Landsat Thematic Mapper (TM) images, from July 1984 and July 1992, were used to identify land use/cover changes in the urban and suburban fringe of the city of Huntsville, Alabama. Image difference was the technique used to quantify the change between the two dates. The eight-year period showed a 16% change, mainly from agricultural lands to urban areas generated by the settlement of industrial, commercial, and residential areas. Visual analysis of the change map (i.e., difference image) supported this phenomenon by showing that most changes were occurring in the vicinity of the major roads and highways across the city.

Dana Kuan

Advanced Model Development for Large Eddy Simulation of Oxy-Combustion and Supercritical Carbon Dioxide Power Cycles

A joint experimental and numerical study is performed to observe the characteristics of a supercritical carbon dioxide turbulent mixing layer in the presence of strong nonlinearities in the thermodynamic and transport properties. A bespoke experimental setup is designed and employed for this purpose and provides insight into macroscopic mixing behavior. The mixing is experimentally observed using two techniques: shadowgraphy and spontaneous Raman scattering. Qualitative and quantitative intensity fields obtained via these techniques yield instantaneous and mean density data. Spanwise temperature data is also collected using analogue resistance temperature detectors. These measurements are used to quantify the level of mixed material within the field. The experimental data are supplemented by a companion high-fidelity numerical study. The numerical results are obtained through fully resolved, three-dimensional direct numerical simulation. The numerical dataset permits observation of the near-field mixing characteristics, which are difficult to measure experimentally due to the rapid dynamics and sharp thermophysical gradients in this area. Qualitative field visualizations are presented, followed by quantitative mixed material results and observations regarding thermodynamic property trends at select locations within the field. One-dimensional spectra of the turbulent kinetic energy and solenoidal dissipation are provided to observe the spectral characteristics of the flow. Reynolds stress anisotropy is analyzed graphically through anisotropy invariance maps (Lumley triangles). The mixing quantification, spectral data and anisotropy analysis of a flow at these thermodynamic conditions represent the main outcomes of the work.

20 FOSSIL-FUELED POWER PLANTS

Atacama Cosmology Telescope A Measurement of Galaxy Cluster Temperatures Through Relativistic Corrections to the Thermal Sunyaev-Zeldovich Effect

The high electron temperature in galaxy clusters (> 1 keV or > 107 K) leads to corrections at the level of a few percent in their thermal Sunyaev-Zeldovich effect signatures. Both the size and frequency dependence of these corrections, which are known as relativistic temperature corrections, depend upon the temperature of the objects. In this work we exploit this effect to measure the average temperature of a stack of Compton-y selected clusters. Specifically, we apply the “spectroscopic method” and search for the temperature that best fits the clusters’ signal measured at frequencies from 30 to 545 GHz by the Atacama Cosmology Telescope and Planck satellite. We measure the average temperature of clusters detected in the Atacama Cosmology Telescope maps to be 8.5 2.4 keV, with an additional systematic error of comparable amplitude dominated by passband uncertainty. Upcoming surveys, such as the Simons Observatory and CMB-S4, have the potential to dramatically improve upon these measurements and thereby enable precision studies of cluster temperatures with millimeter observations. The key challenge for future observations will be mitigating instrumental systematic effects, which already limit this analysis.

William R Coulton

Three-Dimensional, Multi-Phase Unsteady Flow of Water Undergoing Multiple Flow Regimes (Free Surface, Droplet, and Fluid Film)

Upgrades to the Mobile Launcher Rainbird nozzles were implemented for the Artemis II launch to increase water flow rates and improve the mobile launcher deck water coverage while minimizing the water throw distance to avoid impacting the Space Launch System (SLS) rocket nozzles. This analysis describes the use of a three-dimensional, multi-phase, free surface transient computational fluid dynamics (CFD) model to simulate the water flowing out through the Rainbird nozzle and ensure compliance with current Artemis requirements. Flow rates, pressures, velocities, nozzle throw distances and coverage areas were analyzed to ensure that system requirements are met. The completed results were used to make necessary modifications to the Ignition Overpressure Protection and Sound Suppression (IOP/SS) system Rainbird design by reshaping the nozzle used in the system.

CFD

Dirac Fermions and Flat Bands in Phosphorus Carbide Nanotubes: Structural and Quantum Phase Transitions in a Quasi-One-Dimensional Material

Chemically realistic quasi-one-dimensional (1D) materials in which Dirac Fermions and highly degenerate flat bands coexist intrinsically at the Fermi level are exceedingly rare, while representing a highly desirable platform for correlated and topological quantum phenomena. Here, in this work, using specialized symmetry-adapted first-principles calculations we predict a new class of nanomaterials─phosphorus carbide nanotubes (P 2 C 3 NTs)─obtained by rolling monolayer P 2 C 3 , a two-dimensional material shown in a previous letter to host “double Kagome bands”. Both armchair and zigzag P 2 C 3 NTs are stable at room temperature and feature the rare coexistence of Dirac crossings and multiple flat bands at the Fermi level inherited from the underlying honeycomb–Kagome lattice, with the flat bands resilient to elastic deformations. Under large strain, the structure transforms from honeycomb–Kagome to “brick-wall”, accompanied by multiple coupled structural and quantum phase transitions. We also uncover localized edge states, spin splitting from vacancies and dopants, and strain-tunable magnetism. Together, these results establish P 2 C 3 NTs as a chemically specific and mechanically tunable 1D material platform with potential applications in quantum hardware and spintronics.

carbon nanotubes

Autonomous Detection and Classification of Lunar Minerals Using a Convolutional Neural Network Based Framework for the SUCR DALI Project

NASA’s long-term goal is to deploy humans to the Moon and, from there, advance human exploration to Mars, with Artemis missions as pivotal milestones. Raman spectroscopy can uniquely identify minerals, compounds, water states, and other materials, providing distinctive fingerprints for classification. A Raman instrument has been successfully deployed and utilized on the Mars surface via the Perseverance rover, but has not yet been utilized at the lunar surface The SUCR DALI project is working towards developing a Raman spectroscopy instrument to be applied in various lunar mission concepts, including within the Artemis program. The objective of my research is to assist in the maturation of the proposed SUCR DALI lunar Raman instrument through the development of an autonomous detection and classification model capable of identifying minerals and water states on the Moon’s surface.

Convolutional Neural Networks

Twist Engineering of Anisotropic Excitonic and Optical Properties of a Two-Dimensional Magnetic Semiconductor

Two-dimensional (2D) van der Waals (vdW) magnetic semiconductors are a new class of quantum materials for studying the emergent physics of excitons and spins in the 2D limit. Twist engineering provides a powerful tool to manipulate the fundamental properties of 2D vdW materials. Here, in this work, we show that twist engineering of the anisotropic ferromagnetic monolayer semiconductor CrSBr leads to bilayer magnetic semiconductors with continuously tunable magnetic moment, dielectric anisotropy, exciton energy, and linear dichroism. We furthermore provide a model for exciton energy in the media with tunable anisotropy. These results advance fundamental studies of 2D vdW materials and open doors to applications to nano-optics, twistronics, and spintronics.

36 MATERIALS SCIENCE

Ares I-X Ground Diagnostic Prototype

The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.

Machine Learning

Space Shuttle Main Engine Propellant Path Leak Detection Using Sequential Image Processing

Initial research in this study using theoretical radiation transport models established that the occurrence of a leak is accompanies by a sudden but sustained change in intensity in a given region of an image. In this phase, temporal processing of video images on a frame-by-frame basis was used to detect leaks within a given field of view. The leak detection algorithm developed in this study consists of a digital highpass filter cascaded with a moving average filter. The absolute value of the resulting discrete sequence is then taken and compared to a threshold value to produce the binary leak/no leak decision at each point in the image. Alternatively, averaging over the full frame of the output image produces a single time-varying mean value estimate that is indicative of the intensity and extent of a leak. Laboratory experiments were conducted in which artificially created leaks on a simulated SSME background were produced and recorded from a visible wavelength video camera. This data was processed frame-by-frame over the time interval of interest using an image processor implementation of the leak detection algorithm. In addition, a 20 second video sequence of an actual SSME failure was analyzed using this technique. The resulting output image sequences and plots of the full frame mean value versus time verify the effectiveness of the system.