Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Library”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Parameterizable Library Components for SAW Devices

To facilitate quick fabrication of Surface Acoustic Wave (SAW) sensors we have found it necessary to develop a library of parameterizable components. This library is the first module in our strategy towards a design tool that is integrated into existing Electronic Design Automation (EDA) tools. This library is similar to the standard cell libraries found in digital design packages. The library cells allow the user to input the design parameters which automatically generate a detailed layout of the SAW component. This paper presents the results of our development of parameterizable cells for an InterDigitated Transducer (IDT), reflector, SAW delay line, and both one and two port resonators.

Wilson, William C.↗

All-Digital Baseband 65nm PLL/FPLL Clock Multiplier using 10-cell Library

PLLs for clock generation are essential for modern circuits, to generate specialized frequencies for many interfaces and high frequencies for chip internal operation. These circuits depend on analog circuits and careful tailoring for each new process, and making them fault tolerant is an incompletely solved problem. Until now, all digital PLLs have been restricted to sampled data DSP techniques and not available for the highest frequency baseband applications. This paper presents the design and preliminary evaluation of an all-digital baseband technique built entirely with an easily portable 10-cell digital library. The library is also described, as it aids in research and low volume design porting to new processes. The advantages of the digital approach are the wide variety of techniques available to give varying degrees of fault tolerance, and the simplicity of porting the design to new processes, even to exotic processes that may not have analog capability. The only tuning parameter is digital gate delay. An all-digital approach presents unique problems and standard analog loop stability design criteria cannot be directly used. Because of the quantization of frequency, there is effectively infinite gain for very small loop error feedback. The numerically controlled oscillator (NCO) based on a tapped delay line cannot be reliably updated while a pulse is active in the delay line, and ordinarily does not have enough frequency resolution for a low-jitter output.

Shuler, Robert L., Jr.↗

ALL-Digital Baseband 65nm PLL/FPLL Clock Multiplier Using 10-Cell Library

PLLs for clock generation are essential for modern circuits, to generate specialized frequencies for many interfaces and high frequencies for chip internal operation. These circuits depend on analog circuits and careful tailoring for each new process, and making them fault tolerant is an incompletely solved problem. Until now, all digital PLLs have been restricted to sampled data DSP techniques and not available for the highest frequency baseband applications. This paper presents the design and preliminary evaluation of an all-digital baseband technique built entirely with an easily portable 10-cell digital library. The library is also described, as it aids in research and low volume design porting to new processes. The advantages of the digital approach are the wide variety of techniques available to give varying degrees of fault tolerance, and the simplicity of porting the design to new processes, even to exotic processes that may not have analog capability. The only tuning parameter is digital gate delay. An all-digital approach presents unique problems and standard analog loop stability design criteria cannot be directly used. Because of the quantization of frequency, there is effectively infinite gain for very small loop error feedback. The numerically controlled oscillator (NCO) based on a tapped delay line cannot be reliably updated while a pulse is active in the delay line, and ordinarily does not have enough frequency resolution for a low-jitter output.

Schuler, Robert L., Jr.↗

Three-Function Logic Gate Controlled by Analog Voltage

The figure is a schematic diagram of a complementary metal oxide/semiconductor (CMOS) electronic circuit that performs one of three different logic functions, depending on the level of an externally applied control voltage, V(sub sel). Specifically, the circuit acts as A NAND gate at V(sub sel) = 0.0 V, A wire (the output equals one of the inputs) at V(sub sel) = 1.0 V, or An AND gate at V(sub sel) = -1.8 V. [The nominal power-supply potential (VDD) and logic "1" potential of this circuit is 1.8 V.] Like other multifunctional circuits described in several prior NASA Tech Briefs articles, this circuit was synthesized following an automated evolutionary approach that is so named because it is modeled partly after the repetitive trial-and-error process of biological evolution. An evolved circuit can be tested by computational simulation and/or tested in real hardware, and the results of the test can provide guidance for refining the design through further iteration. The evolutionary synthesis of electronic circuits can now be implemented by means of a software package Genetic Algorithms for Circuit Synthesis (GACS) that was developed specifically for this purpose. GACS was used to synthesize the present trifunctional circuit. As in the cases of other multifunctional circuits described in several prior NASA Tech Briefs articles, the multiple functionality of this circuit, the use of a single control voltage to select the function, and the automated evolutionary approach to synthesis all contribute synergistically to a combination of features that are potentially advantageous for the further development of robust, multiple-function logic circuits, including, especially, field-programmable gate arrays (FPGAs). These advantages include the following: This circuit contains only 9 transistors about half the number of transistors that would be needed to obtain equivalent NAND/wire/AND functionality by use of components from a standard digital design library. If multifunctional gates like this circuit were used in the place of the configurable logic blocks of present commercial FPGAs, it would be possible to change the functions of the resulting digital systems within shorter times. For example, by changing a single control voltage, one could change the function of thousands of FPGA cells within nanoseconds. In contrast, typically, the reconfiguration in a conventional FPGA by use of bits downloaded from look-up tables via a digital bus takes microseconds.

Zebulum, Ricardo↗

Implementation of Fiducial-Based Image Registration in the Cyberknife Robotic System

Fiducial-based image registration methodology as implemented in the Cyberknife system is explored. The Cyberknife is a radiosurgery system that uses image guidance technology and computer-controlled robotics to determine target positions and adjust beam directions accordingly during the dose delivery. The image guidance system consists of 2 x-ray sources mounted on the ceiling and a detection system mounted on both sides of the treatment couch. Two orthogonal live radiographs are taken prior to and during patient treatment. Fiducial markers are identified on these radiographs and compared to a library of digital reconstructed radiographs (DRRs) using the fiducial extraction software. The fiducial extraction software initially sets an intensity threshold on the live radiographs to generate white areas on black images referred to as 'blobs.' Different threshold values are being used and blobs at the same location are assumed to originate from the same object. The number of blobs is then reduced by examining each blob against a predefined set of properties such as shape and exposure levels. The remaining blobs are further reduced by examining the location of the blobs in the inferior-superior patient axis. Those blobs that have the corresponding positions are assumed to originate from the same object. The remaining blobs are used to create fiducial configurations and are compared to the reference configuration from the computed tomography (CT) image dataset for treatment planning. The best-fit configuration is considered to have the appropriate fiducial markers. The patient position is determined based on these fiducial markers. During the treatment, the radiation beam is turned off when the Cyberknife changes nodes. This allows a time window to acquire live radiographs for the determination of the patient target position and to update the robotic manipulator to change beam orientations accordingly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Raman Digital Twin of Monolayer Janus Transition Metal Dichalcogenides

Monolayer transition metal dichalcogenides (TMDs) are a key class of two-dimensional (2D) materials with broad technological potential. Their Janus counterparts exhibit unique properties due to broken out-of-plane symmetry and further enrich the functionalities of TMDs. However, experimental synthesis and identification of Janus TMDs remain challenging. It is thus highly desirable to have a rapid, simple, and in situ characterization technique to monitor, in real time, the conversion process from the parent to Janus structure. Raman spectroscopy stands out for such a task as it is a powerful, nondestructive, and very commonly used tool to characterize 2D materials both in situ and ex situ. To realize the full potential of Raman spectroscopy on rapid characterization of Janus TMDs, we present a computational “Raman digital twin” library for various monolayer Janus TMDs in both 2H and Td phases. We focus on group-6 TMDs: MoS 2 , WS 2 , MoSe 2 , WSe 2 , MoTe 2 , WTe 2 and their Janus variants: MoSSe, MoSTe, MoSeTe, WSSe, WSTe, and WSeTe. Using first-principles density functional theory (DFT), we calculate their vibrational properties and predict distinct Raman fingerprints. These phonon and Raman signatures reflect each material’s structural symmetry and atomic composition, enabling clear identification via Raman spectroscopy. Our theoretical work supports experimental efforts by providing benchmarks for material identification, structural analysis, and quality control. In conclusion, the computational library expedites the discovery and development of Janus 2D materials, facilitating tighter integration between theoretical predictions and experimental validation.

Chalcogenides↗

MO-C-17A-13: Uncertainty Evaluation of CT Image Deformable Registration for H and N Cancer Adaptive Radiotherapy

Purpose: To evaluate uncertainties of organ specific Deformable Image Registration (DIR) for H and N cancer Adaptive Radiation Therapy (ART). Methods: A commercial DIR evaluation tool, which includes a digital phantom library of 8 patients, and the corresponding “Ground truth Deformable Vector Field” (GT-DVF), was used in the study. Each patient in the phantom library includes the GT-DVF created from a pair of CT images acquired prior to and at the end of the treatment course. Five DIR tools, including 2 commercial tools (CMT1, CMT2), 2 in-house (IH-FFD1, IH-FFD2), and a classic DEMON algorithms, were applied on the patient images. The resulting DVF was compared to the GT-DVF voxel by voxel. Organ specific DVF uncertainty was calculated for 10 ROIs: Whole Body, Brain, Brain Stem, Cord, Lips, Mandible, Parotid, Esophagus and Submandibular Gland. Registration error-volume histogram was constructed for comparison. Results: The uncertainty is relatively small for brain stem, cord and lips, while large in parotid and submandibular gland. CMT1 achieved best overall accuracy (on whole body, mean vector error of 8 patients: 0.98±0.29 mm). For brain, mandible, parotid right, parotid left and submandibular glad, the classic Demon algorithm got the lowest uncertainty (0.49±0.09, 0.51±0.16, 0.46±0.11, 0.50±0.11 and 0.69±0.47 mm respectively). For brain stem, cord and lips, the DVF from CMT1 has the best accuracy (0.28±0.07, 0.22±0.08 and 0.27±0.12 mm respectively). All algorithms have largest right parotid uncertainty on patient #7, which has image artifact caused by tooth implantation. Conclusion: Uncertainty of deformable CT image registration highly depends on the registration algorithm, and organ specific. Large uncertainty most likely appears at the location of soft-tissue organs far from the bony structures. Among all 5 DIR methods, the classic DEMON and CMT1 seem to be the best to limit the uncertainty within 2mm for all OARs. Partially supported by research grant from Elekta.

60 APPLIED LIFE SCIENCES↗

Standard Transistor Array (STAR). Volume 1: Placement technique

A large scale integration (LSI) technology, the standard transistor array uses a prefabricated understructure of transistors and a comprehensive library of digital logic cells to allow efficient fabrication of semicustom digital LSI circuits. The cell placement technique for this technology involves formation of a one dimensional cell layout and "folding" of the one dimensional placement onto the chip. It was found that, by use of various folding methods, high quality chip layouts can be achieved. Methods developed to measure of the "goodness" of the generated placements include efficient means for estimating channel usage requirements and for via counting. The placement and rating techniques were incorporated into a placement program (CAPSTAR). By means of repetitive use of the folding methods and simple placement improvement strategies, this program provides near optimum placements in a reasonable amount of time. The program was tested on several typical LSI circuits to provide performance comparisons both with respect to input parameters and with respect to the performance of other placement techniques. The results of this testing indicate that near optimum placements can be achieved by use of the procedures incurring severe time penalties.

Cox, G. W.↗

Processing MAGSAT data for comparison with geoid anomalies

A digital data library of MAGSAT data consisting of 1,615,636 measurements from the quiet data set, is geographically sorted, and allows rapid analysis and processing of all the quiet magnetic data about any selected location. Because this library of MAGSAT data is compatible with existing gravity and geoid data library processing and display system software, correlations between MAGSAT, surface gravity, GEOS-3 radar altimeter geoid and bathymetric data sets can be conveniently detected and analyzed. Polynomial trends from each half-orbit were removed as an effective way of estimating and removing ring current effects following estimation of the core field contribution. It was found that a third order polynomial is the lowest polynomial order that appears to provide the best consistency of residual anomalies between coincident orbits.

Bowin, C. O.↗

MAGSAT correlations with geoid anomalies

A digital data library of MAGSAT data is described and its applications and capabilities are reviewed. Polynomial trends were removed from each half-orbit in order to estimate and remove ring current effects from the data. The MAGSAT data in the Gulf of Mexico region was analyzed to define better the possible relation of the negative MAGSAT anomaly there to the negative residual geoid anomaly in the western Gulf of Mexico. Since the shape and location of the negative magnetic anomaly are variable depending upon the particular polynomial surface and curve orders used, no definitive conclusion as to the degree of correspondance between the residual geoid and MAGSAT lithosphere anomalies is offered.

Bowin, C. O.↗

Documentation for the machine-readable version of A Library of Stellar Spectra (Jacoby, Hunter and Christian 1984)

The machine readable library as it is currently being distributed from the Astronomical Data Center is described. The library contains digital spectral for 161 stars of spectral classes O through M and luminosity classes 1, 3 and 5 in the wavelength range 3510 A to 7427 A. The resolution is approximately 4.5 A, while the typical photometric uncertainty of each resolution element is approximately 1 percent and broadband variations are 3 percent. The documentation includes a format description, a table of the indigenous characteristics of the magnetic tape file, and a sample listing of logical records exactly as they are recorded on the tape.

Warren, W. H., Jr.↗

Midinfrared (2.5-13.5 microns) reflectance spectra of powdered stony meteorites

Asteroid spectral measurements are presently approached via comparisons with reflectance spectra from 60 powdered meteorite samples representing 50 different meteorites. While the powdered meteorites have undergone alteration by exposure to water vapor and by hydrocarbon contamination characterized by absorption bands near 3.45 microns, they retain various other spectral features which render them useful for identification. While these features can be used independently to ascertain mineralogy and meteorite type, the use of the entire spectrum in a digital search library is preferred for successful identification.

Salisbury, John W.↗

Infrared (2.08-14 micron) spectra of powered stony meteorites

Infrared biconical reflectance spectra of 60 powdered meteorite samples, representing 50 different stony meteorites, were measured as analogues of asteroidal regolith. Representative samples were measured in directional hemispherical reflectance to assure that Kirchhoff's Law can be used to predict relative emissivity from the reflectance spectra. These spectral data confirm that the O-H fundamental absorption band near 2.9 microns is an extremely sensitive indicator of incipient alteration, which often has taken place in powdered meteorite samples exposed only to water vapor in the air. Such non-carbonaceous samples typically contain less than 1 percent water by weight. Likewise, the C-H fundamental absorption bands near 3.4 and 3.5 microns are equally sensitive indicators of contamination with volatile hydrocarbons, which can also be absorbed from the air. The heavy, macromolecular hydrocarbons native to chondrites do not display such heavy bands, making detection of these bands in remote sensing of asteroids unlikely. Despite the spectral artifacts introduced by alteration and hydrocarbon contamination, powdered stony meteorites display a wide variety of real spectral features that can be used for their identification, including residual reststrahlen bands, absorption bands, and the Christiansen feature. Researchers found that the wavelengths of the peaks or troughs of each of these spectral features can be used independently to infer meteorite composition, but the best results are obtained when the entire spectral curve is used, or at least the portion of it encompassed by the 8 to 14 micron atmospheric window, in a digital search library.

Salisbury, J. W.↗

Automatic Keyword Extraction from Individual Documents

This paper introduces a novel and domain-independent method for automatically extracting keywords, as sequences of one or more words, from individual documents. We describe the method’s configuration parameters and algorithm, and present an evaluation on a benchmark corpus of technical abstracts. We also present a method for generating lists of stop words for specific corpora and domains, and evaluate its ability to improve keyword extraction on the benchmark corpus. Finally, we apply our method of automatic keyword extraction to a corpus of news articles and define metrics for characterizing the exclusivity, essentiality, and generality of extracted keywords within a corpus.

99 GENERAL AND MISCELLANEOUS↗

High-throughput characterization of stresses in thin film materials libraries using Si cantilever array wafers and digital holographic microscopy

We report the development of an advanced high-throughput stress characterization method for thin film materials libraries sputter-deposited on micro-machined cantilever arrays consisting of around 1500 cantilevers on 4-inch silicon-on-insulator wafers. A low-cost custom-designed digital holographic microscope (DHM) is employed to simultaneously monitor the thin film thickness, the surface topography and the curvature of each of the cantilevers before and after deposition. The variation in stress state across the thin film materials library is then calculated by Stoney's equation based on the obtained radii of curvature of the cantilevers and film thicknesses. DHM with nanometer-scale out-of-plane resolution allows stress measurements in a wide range, at least from several MPa to several GPa. By using an automatic x-y translation stage, the local stresses within a 4-inch materials library are mapped with high accuracy within 10 min. The speed of measurement is greatly improved compared with the prior laser scanning approach that needs more than an hour of measuring time. A high-throughput stress measurement of an as-deposited Fe-Pd-W materials library was evaluated for demonstration. The fast characterization method is expected to accelerate the development of (functional) thin films, e.g., (magnetic) shape memory materials, whose functionality is greatly stress dependent.

36 MATERIALS SCIENCE↗

INFRARED SPECTRAL SIGNATURES: CREATION OF REFERENCE DATA FOR VAPORS AND LIQUIDS

Two primary goals of infrared spectroscopic dection are chemical identification and quantification. In order to accomplish these goals, a comprehensive and quantitative spectral library suitable for digital manipulation is required. To a large degree, the contents of such a library depend on the application. Since the primary application of the PNNL/DOE spectral library is for environmental monitoring, we have focused our efforts on hazardous pollutants, as well as a large variety of natural and anthropogenic chemicals. As a spin-off project and in collaboration with Dugway Proving Ground, we also had the opportunity to analyze a limited set of chemical warfare agents (CWAs).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Transient Efficiency Flexibility and Reliability Optimization of Coal-Fired Power Plants (Model-Based Estimation Library Report)

This document pertains to the reporting requirements of DOE contract FE-0031767. The document covers the development of a model-based estimation (MBE) library for generating digital twins of coal-fired power plants (CFPPs). The models used by the MBE are transient and physics-based. Model classes in the library that correspond to different components in CFPPs are presented with physical explanations and representative results. MBE library provides Extended Kalman Filter (EKF), and Unscented Kalman Filter (UKF) algorithms. The MBE library is generic and can be used to represent a variety of CFPPs. A digital twin of a CFPP will be created as the reduced-order model of that CFPP is embedded in the developed MBE architecture.

20 FOSSIL-FUELED POWER PLANTS↗