Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Application of transport techniques to the analysis of NERVA shadow shields

A radiation shield internal to the NERVA nuclear rocket reactor required to limit the neutron and photon radiation levels at critical components located external to the reactor was evaluated. Two significantly different shield mockups were analyzed: BATH, a composite mixture of boron carbide, aluminum and titanium hydride, and a borated steel-liquid hydrogen system. Based on the comparisons between experimental and calculated neutron and photon radiation levels, the following conclusions were noted: (1) The ability of two-dimensional discrete ordinates code to predict the radiation levels internal to and at the surface of the shield mockups was clearly demonstrated. (2) Internal to the BATH shield mockups, the one-dimensional technique predicted the axial variation of neutron fluxes and photon dose rates; however, the magnitude of the neutron fluxes was about a factor of 1.8 lower than the two-dimensional analysis and the photon dose rate was a factor of 1.3 lower.

Capo, M. A.↗

Nuclear Thermal Propulsion (NTP) Fission Product and Source Term Analysis

Nuclear thermal propulsion (NTP) is an in-space propulsion technology that uses a nuclear reactor to directly heat a propellant to provide high thrust, at higher efficiencies than achievable with conventional chemical propulsion systems. Due to the ability of NTP rockets to efficiently provide high thrust, this technology has been proposed for long duration space missions such as crewed missions to Mars and beyond. A primary hurdle for NTP technology development is the demonstration of an integrated reactor engine system to verify its functionality and performance. This primarily requires the manufacture and testing of candidate reactor and engine technologies to demonstrate the proposed design enables desired performance and exhibits acceptable response under all known operation modes. A major component in this testing is fission product accumulation, since after operation radioactive isotopes can be produced and pose radiological dose concerns. This paper explains the background behind fission product analysis and the methodology used to evaluate current reactor designs and identify the amount of fission products present and their radiological impact. Results of multiple thrust level engines at different time periods are discussed and highlight the need for additional experimental testing to confirm fractional release levels of fission products out of the system. Benchmarking of models and future paths of analysis are also discussed.

Fission↗

Nuclear Thermal Propulsion (NTP) Fission Product and Source Term Analysis

Nuclear thermal propulsion (NTP) is an in-space propulsion technology that uses a nuclear reactor to directly heat a propellant to provide high thrust, at higher efficiencies than achievable with conventional chemical propulsion systems. Due to the ability of NTP rockets to efficiently provide high thrust, this technology has been proposed for long duration space missions such as crewed missions to Mars and beyond. A primary hurdle for NTP technology development is the demonstration of an integrated reactor engine system to verify its functionality and performance. This primarily requires the manufacture and testing of candidate reactor and engine technologies to demonstrate the proposed design enables desired performance and exhibits acceptable response under all known operation modes. A major component in this testing is fission product accumulation, since after operation radioactive isotopes can be produced and pose radiological dose concerns. This paper explains the background behind fission product analysis and the methodology used to evaluate current reactor designs and identify the amount of fission products present and their radiological impact. Results of multiple thrust level engines at different time periods are discussed and highlight the need for additional experimental testing to confirm fractional release levels of fission products out of the system. Benchmarking of models and future paths of analysis are also discussed.

Nuclear Thermal Propulsion↗

Total body calcium analysis using the Ca-12(n, alpha) Ar-37 reaction

A low dose neutron activation technique was developed to measure total body calcium in vivo. The effort had included development of irradiation and processing facilities and conduction of human studies to determine the accuracy and precision of measurement attainable with the systems.

Lewellen, T. K.↗

An analysis of interplanetary space radiation exposure for various solar cycles

The radiation dose received by crew members in interplanetary space is influenced by the stage of the solar cycle. Using the recently developed models of the galactic cosmic radiation (GCR) environment and the energy-dependent radiation transport code, we have calculated the dose at 0 and 5 cm water depth; using a computerized anatomical man (CAM) model, we have calculated the skin, eye and blood-forming organ (BFO) doses as a function of aluminum shielding for various solar minima and maxima between 1954 and 1989. These results show that the equivalent dose is within about 15% of the mean for the various solar minima (maxima). The maximum variation between solar minimum and maximum equivalent dose is about a factor of three. We have extended these calculations for the 1976-1977 solar minimum to five practical shielding geometries: Apollo Command Module, the least and most heavily shielded locations in the U.S. space shuttle mid-deck, center of the proposed Space Station Freedom cluster and sleeping compartment of the Skylab. These calculations, using the quality factor of ICRP 60, show that the average CAM BFO equivalent dose is 0.46 Sv/year. Based on an approach that takes fragmentation into account, we estimate a calculation uncertainty of 15% if the uncertainty in the quality factor is neglected.

NASA Discipline Radiation Health↗

Modeling the effects of exercise during 100% oxygen prebreathe on the risk of hypobaric decompression sickness

BACKGROUND: Several previous studies indicated that exercise during prebreathe with 100% O2 decreased the incidence of hypobaric decompression sickness (DCS). We report a meta-analysis of these investigations combined with a new study in our laboratory to develop a statistical model as a predictive tool for DCS. HYPOTHESIS: Exercise during prebreathe increases N2 elimination in a theoretical 360-min half-time compartment decreasing the incidence of DCS. METHODS: A dose-response probability tissue ratio (TR) model with 95% confidence limits was created for two groups, prebreathe with exercise (n = 113) and resting prebreathe (n = 113), using nonlinear regression analysis with maximum likelihood optimization. RESULTS: The model predicted that prebreathe exercise would reduce the residual N2 in a 360-min half-time compartment to a level analogous to that in a 180-min compartment. This finding supported the hypothesis. The incidence of DCS for the exercise prebreathe group was significantly decreased (Chi-Square = 17.1, p < 0.0001) from the resting prebreathe group. CONCLUSIONS: The results suggested that exercise during prebreathe increases tissue perfusion and N2 elimination approximately 2-fold and markedly lowers the risk of DCS. Based on the model, the prebreathe duration may be reduced from 240 min to a predicted 91 min for the protocol in our study, but this remains to be verified. The model provides a useful planning tool to develop and test appropriate prebreathe exercise protocols and to predict DCS risks for astronauts.

NASA Program Environmental Health↗

Solar Variability and the Near-Earth Environment: Mining Enhanced Low Dose Rate Sensitivity Data From the Microelectronics and Photonics Test Bed Space Experiment

This effort is a detailed analysis of existing microelectronics and photonics test bed satellite data from one experiment, the bipolar test board, looking to improve our understanding of the enhanced low dose rate sensitivity (ELDRS) phenomenon. Over the past several years, extensive total dose irradiations of bipolar devices have demonstrated that many of these devices exhibited ELDRS. In sensitive bipolar transistors, ELDRS produced enhanced degradation of base current, resulting in enhanced gain degradation at dose rates <0.1 rd(Si)/s compared to similar transistors irradiated at dose rates >1 rd(Si)/s. This Technical Publication provides updated information about the test devices, the in-flight experiment, and both flight-and ground-based observations. Flight data are presented for the past 5 yr of the mission. These data are compared to ground-based data taken on devices from the same date code lots. Information about temperature fluctuations, power shutdowns, and other variables encountered during the space flight are documented.

Turflinger, T.↗

A Confidence-Based Approach to Including Survivors in a Probabilistic TID Failure Assessment

A probabilistic total ionizing dose (TID) failure assessment is extended to include survivor data, enabling the bounding of failure probability to a desired confidence level (CL) without failure data. The extension provides an avenue for analyzing microelectronics tested for TID without reaching a failure mode, a scenario often encountered by missions utilizing commercial-off-the-shelf (COTS) technologies. Using the type-I censored likelihood formulation and a realistic upper bound on expected device performance, the failure probability space is bounded by confidence contours within the context of a variable environment. The framework accommodates any type of distribution assumed for the part failure or the environment under consideration. Furthermore, the framework can be utilized pre-emptively to plan future device TID tests, minimizing costs while meeting survival requirements. Heritage data may also be used as survivors to further minimize testing costs when parts are from the same lot, but the amount of constraint derived from heritage is limited. Altogether, the framework enables a formal, mathematically rigorous analysis of radiation tolerant devices tested to a maximum dose, as well as flight heritage, in a hardness assurance methodology.

confidence↗

NASA GeneLab Platform Utilized for Biological Response to Space Radiation in Animal Models

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors that will impact the health of astronauts on extended missions outside the protective effects of Earth’s magnetic field. The NASA GeneLab project has detailed information on radiation exposure using animal models with curated dosimetry information for spaceflight experiments. We analyzed multiple GeneLab omics datasets associated with both ground-based and spaceflight radiation studies that included in vivo and in vitro approaches. A range of ions from protons to iron particles with doses from 0.1 Gy to 1.0 Gy for ground studies and samples flown in Low Earth Orbit (LEO) with total doses of 1.0 mGy to 30 mGy were utilized From this analysis we were able to identify distinct biological signatures associating specific ions with specific biological responses due to radiation exposure in space. For example, we discovered changes in mitochondrial function, ribosomal assembly, and immune pathways as a function of dose. We provided a summary of how the GeneLab’s rich database of omics experiments with animal models can be used to generate novel hypotheses to better understand human health risks from GCR exposures.

Afshin Beheshti↗

NASA GeneLab Platform Utilized for Space Radiation Dosimetry Biological Response Compared to Radiation Ground Studies

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors that will impact the health of astronauts on extended missions outside the protective effects of Earth’s magnetic field. The NASA GeneLab project has detailed information on radiation exposure using animal models with curated dosimetry information for spaceflight experiments. We analyzed multiple GeneLab omics datasets associated with both ground-based and spaceflight radiation studies that included in vivo and in vitro approaches. A range of ions from protons to iron particles with doses from 0.1 Gy to 1.0 Gy for ground studies and samples flown in Low Earth Orbit (LEO) with total doses of 1.0 mGy to 30 mGy were utilized From this analysis we were able to identify distinct biological signatures associating specific ions with specific biological responses due to radiation exposure in space. For example, we discovered changes in mitochondrial function, ribosomal assembly, and immune pathways as a function of dose. We provided a summary of how the GeneLab’s rich database of omics experiments with animal models can be used to generate novel hypotheses to better understand human health risks from GCR exposures.

Afshin Beheshti↗

Radiation-Hardness Data For Semiconductor Devices

Document presents data on and analysis of radiation hardness of various semiconductor devices. Data specifies total-dose radiation tolerance of devices. Volume 1 of report covers diodes, bipolar transistors, field effect transistors, silicon controlled rectifiers and optical devices. Volume 2 covers integrated circuits. Volume 3 provides detailed analysis of data in volumes 1 and 2.

Price, W. E.↗

Assessment of Evidence Base from Medical Debriefs Data on Space Motion Sickness Incidence and Treatment

An objective of this data compilation and analysis project is to examine incidence and treatment efficacy of common patho-physiological disturbances during spaceflight. Analysis of medical debriefs data indicated that astronauts used medications to alleviate symptoms of four major ailments for which astronauts received treatment for sleep disturbances, space motion sickness (SMS), pain (headache, back pain) and sinus congestion. In the present data compilation and analysis project on SMS treatment during space missions, subject demographics (gender, age, first-time or repeat flyer), incidence and severity of SMS symptoms and subjective treatment efficacy from 317 crewmember debrief records were examined from STS-1 through STS-89. Preliminary analysis of data revealed that 50% of crew members reported SMS symptoms on at least one flight and 22% never experienced it. In addition, there were 387 medication dosing episodes reported, and promethazine was the most commonly used medication. Results of analysis of symptom check lists, medication use/efficacy and gender and flight record differences in incidence and treatment efficacy will be presented. Evidence gaps for treatment efficacy along with medication use trend analysis will be identified.

Younker, D.R.↗

Effect of Sampling Schedule on Pharmacokinetic Parameter Estimates of Promethazine in Astronauts

Six astronauts on the Shuttle Transport System (STS) participated in an investigation on the pharmacokinetics of promethazine (PMZ), a medication used for the treatment of space motion sickness (SMS) during flight. Each crewmember completed the protocol once during flight and repeated thirty days after returned to Earth. Saliva samples were collected at scheduled times for 72 h after PMZ administration; more frequent samples were collected on the ground than during flight owing to schedule constraints in flight. PMZ concentrations in saliva were determined by a liquid chromatographic/mass spectrometric (LC-MS) assay and pharmacokinetic parameters (PKPs) were calculated using actual flight and ground-based data sets and using time-matched sampling schedule on ground to that during flight. Volume of distribution (V(sub c)) and clearance (Cl(sub s),) decreased during flight compared to that from time-matched ground data set; however, Cl(sub s) and V(sub c) estimates were higher for all subjects when partial ground data sets were used for analysis. Area under the curve (AUC) normalized with administered dose was similar in flight and partial ground data; however AUC was significantly lower using time-matched sampling compared with the full data set on ground. Half life (t(sub 1/2)) was longest during flight, shorter with matched-sampling schedule on ground and shortest when complete data set from ground was used. Maximum concentration (C(sub max)), time for C(sub max), (t(sub max)), parameters of drug absorption, depicted a similar trend with lowest and longest respectively, during flight, lower with time-matched ground data and highest and shortest with full ground data.

Boyd, Jason L.↗

NASA GeneLab Platform Utilized for Space Radiation Dosimetry Biological Response Compared to Radiation Ground Studies

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors factor that will impact health of astronauts on extended missions outside the protective effects of the Earth's magnetic field. Currently there are gaps in our knowledge of the health risks associated with chronic low dose, low dose rate ionizing radiation, specifically ions associated with high (H) atomic number (Z) and energy (E). The NASA GeneLab project (genelab.nasa.gov) aims to provide a detailed library of Omics datasets associated with biological samples exposed to HZE. The GeneLab Data System (GLDS) includes datasets from both spaceflight and ground-based studies, a majority of which involved exposure to ionizing radiation. Recently GeneLab has also assessed radiation dosimetry data with omics datasets associated with samples flown to the International Space Station (ISS). The combination of the detailed information on radiation exposure for ground-based studies and curated dosimetry information for spaceflight experiments allows GeneLab to be the first comprehensive Omics database for space related research from which an investigator can generate hypotheses to direct future experiments utilizing both ground and space biological radiation data. We demonstrate the usefulness of these datasets by analyzing multiple GeneLab datasets associated with both radiation ground-based studies and spaceflight studies. The radiation ground based studies we analyzed includes both in vivo and in vitro work with a range ions from protons to iron particles with doses from 0.1Gy to 2Gy. These datasets were compared to both in vivo and in vitro datasets from samples flown to the ISS and on shorter shuttle missions with total doses of 0.1 mGy to 30 mGys. From this analysis we were able to associate distinct biological signatures associating specific ions to specific biological response to radiation exposure in space. For example, we discovered radiation biological response related to cardiovascular effects from proton ground studies are the dominating response for samples related to cardiovascular effects on the ISS. With this work we will provide a summary of how different ions will impact different biological response in space and how this can be used in future studies to assess optimal ground experiments to simulate space radiation.

Beheshti, Afshin↗

Oculometric Analysis of Saccadic Compensation for Visual Motion Processing Impairment due to Alcohol and Sleep Disruption

The Visuomotor Control Laboratory at Ames Research Center has developed a 5-minute ocular tracking test that computes 21 largely independent metrics of visuomotor performance, reflecting neural signal processing along a number of distinct pathways through cortex, brainstem, and cerebellum. Human sensorimotor performance is resilient to the challenges and stressors of many operational environments, in part, because overall performance is achieved through multiple parallel systems. Our multidimensional oculometrics allow us to examine impacts on these sub-components separately. To illustrate this, we contrasted the effects of two mild neural stressors, acute sleep-deprivation and low-dose alcohol. We have previously shown that, in both cases, oculometric analysis is a highly sensitive indicator of impairment. Here we quantified not only the observed impact on the performance of one sub-system, smooth pursuit, which uses high-level cortical processing of visual motion to track a moving object, but also the observed (partial) compensation by an evolutionarily older mid-brain and brainstem subsystem, saccades, which generates jumps in eye position to catch up with the target when smooth pursuit is inadequate. Specifically, we examined the dose-response (effect size vs. dose size) of the ground lost (pursuit deficit) and the ground recouped (saccadic compensation) across three separate studies – acute low-dose alcohol administration (16 subjects), acute sleep loss (12 subjects), and acute sleep loss with caffeine intervention (9 subjects). We computed the dose-response slopes using linear regression. The figure below shows that, in the case of acute sleep deprivation, the resulting slopes for ground lost and ground recouped (mean ± SE across subjects) were significantly different (paired t-test, t(11) = 5.17, p < 0.001), indicating poor saccadic compensation. However, when sleep loss was coupled with caffeine ingestion, ground lost was decreased and ground recouped increased such that the slopes were no longer different (t(8) = -0.05, p = 0.965). With alcohol, the two slopes were large albeit not significantly different (t(15) = 0.96, p = 0.351), indicating significant pursuit impairment but effective saccadic compensation. Our findings show that sleep deprivation and alcohol affect oculomotor performance differently. Low-dose alcohol effects appear predominantly cortical, with effective brainstem compensation. Sleep loss and circadian disruption however appears to affect both cortical and brainstem pathways with caffeine providing an effective countermeasure to both effects. Beyond the mere detection of impairment, our oculometric assessment allows us to characterize the nature of the deficit, to provide insight into the neural substrate, and to assess the effectiveness of countermeasures.

pursuit↗

Impact of Gender on Pharmocokinetics of Intranasal Scopolamine

Introduction: An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS), which is commonly experienced by astronauts during space missions. The bioavailability and pharmacokinetics (PK) were evaluated under IND guidelines. Since information is lacking on the effect of gender on the PK of Scopolamine, we examined gender differences in PK parameters of INSCOP at three dose levels of 0.1, 0.2 and 0.4 mg. Methods: Plasma scopolamine concentrations as a function of time data were collected from twelve normal healthy human subjects (6 male/6 female) who participated in a fully randomized double blind crossover study. The PK parameters were derived using WinNonlin. Covariate analysis of PK profiles was performed using NONMEN and statistically compared using a likelihood ratio test on the difference of objective function value (OFV). Statistical significance for covariate analysis was set at P<0.05(ΔOFV=3.84). Results: No significant difference in PK parameters between male and female subjects was observed with 0.1 and 0.2 mg doses. However, CL and Vd were significantly different between male and female subjects at the 0.4 mg dose. Results from population covariate modeling analysis indicate that a onecompartment PK model with first-order elimination rate offers best fit for describing INSCOP concentration-time profiles. The inclusion of sex as a covariate enhanced the model fitting (ΔOFV=-4.1) owing to the genderdependent CL and Vd differences after the 0.4 mg dose. Conclusion: Statistical modeling of scopolamine concentration-time data suggests gender-dependent pharmacokinetics of scopolamine at the high dose level of 0.4 mg. Clearance of the parent compound was significantly faster and the volume of distribution was significantly higher in males than in females, As a result, including gender as a covariate to the pharmacokinetic model of scopolamine offers the best fit for PK modeling of the drug at dose of 0.4 mg or higher.

Putcha, L.↗

Total Ionizing Dose Test of Analog Devices’ AD654 Voltage to Frequency Converter

Analog Devices’ AD654 was tested for total ionizing dose (TID) response beginning on February 13, 2017. This device has the Radiation Effects and Analysis Group Identification (REAG ID) number 16-036. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

B. Freeman↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗