Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC WIRING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Developing a Novel Platform for Characterizing Thermoelectric Materials for Uncooled Detectors for Land Imaging Applications

Thermal land imaging (imaging at ~8-14 micron optical wavelength) is an essential tool for understanding and managing terrestrial freshwater resources. Current thermal imaging instruments employ low temperature detectors, which require cryocoolers. Consequently, cost-saving reductions in size, weight, and power can be achieved by employing uncooled detectors. One uncooled detector concept, which NASA is pursuing, is a thermopile detector with sub-micron thick doped-Si thermoelectric materials. In order to characterize the thermoelectric properties of the doped silicon, we designed and optimized a novel apparatus. This simple apparatus measures the Seebeck coefficient with thermally isolated stages and LABVIEW automation. We optimized thermal stability using PID tuning and optimized the thermal contact between the thin film samples and stages using electrically conductive springs. Utilizing our apparatus, we measured the Seebeck coefficient of 0.45 micron thick phosphorus-doped single crystal Si samples bonded to alumina substrates. Using these Seebeck coefficient measurements and four-wire electrical resistivity measurements, we determined the relationship between the thermoelectric figure of merit and dopant concentration. These characterization results for doped-Si will guide our thermopile detector design to provide an optimal and competitive detector alternative for future thermal imaging instruments.

Reid, Riley A.↗

Self-Healing Polymer Materials for Wire Insulation, Polyimides, Flat Surfaces, and Inflatable Structures

Materials based on low melt polyimide, polyurea, or polyurethane chemistry have been developed which exhibit self-healing properties. These high performance polymers can be utilized either by themselves or in combination with microcapsule technology to deliver self-healing properties to electrical wire insulation or in other high performance, thin wall technologies such as inflatable structures.

Jolley, Scott T.↗

Thermally Conductive Melt-Processable Polyimide HBN Micro-Composites for High Temperature Electrical Insulation Applications

Thermoplastic polymers exhibit excellent dielectric properties and manufacturing robustness. These properties mark thermoplastics as competitive material candidates for electrical insulation applications. However, the high-temperature performance of most thermoplastics is insufficient to meet the electrical wiring requirements for next-generation air and space transportation engineering designs, with continuous operation temperature requirements of up to 200 °C among other design requirements. Furthermore, the low thermal conductivity (κ) of polymers as a material class leads to heat trapping within wires which can amplify thermal stresses. As a result, there is a need to investigate candidate thermoplastic systems for their high temperature, dielectric, and κ performance.

polyimide↗

Next Generation Wiring

Wiring is a major operational component on aerospace hardware that accounts for substantial weight and volumetric space. Over time wire insulation can age and fail, often leading to catastrophic events such as system failure or fire. The next generation of wiring must be reliable and sustainable over long periods of time. These features will be achieved by the development of a wire insulation capable of autonomous self-healing that mitigates failure before it reaches a catastrophic level. In order to develop a self-healing insulation material, three steps must occur. First, methods of bonding similar materials must be developed that are capable of being initiated autonomously. This process will lead to the development of a manual repair system for polyimide wire insulation. Second, ways to initiate these bonding methods that lead to materials that are similar to the primary insulation must be developed. Finally, steps one and two must be integrated to produce a material that has no residues from the process that degrades the insulating properties of the final repaired insulation. The self-healing technology, teamed with the ability to identify and locate damage, will greatly improve reliability and safety of electrical wiring of critical systems. This paper will address these topics, discuss the results of preliminary testing, and remaining development issues related to self-healing wire insulation.

Medelius, Petro↗

Saran film is fire-retardant in oxygen atmosphere

Saran was tested for flammability as a wrapping on TFE-insulated electrical wire bundles in oxygen gas at pressures of 7.5 psia and 14.7 psia. It was found to be fire retardant or self-extinguishing in most instances.

Goodwin, J. T.↗

Color identification testing device

Testing device, which determines ability of a technician to identify color-coded electric wires, is superior to standard color blindness tests. It tests speed of wire selection, detects partial color blindness, allows rapid testing, and may be administered by a color blind person.

Brawner, E. L.↗

Electronic packaging and cabling

Testing electrical, mechanical, and handling properties and environmental characteristics of small gage electrical wire for interplanetary spacecraft

Source record↗

Ablation sensor Patent

Ablation sensor for measuring char layer recession rate using electric wires

Le Bel, P. J.↗

Microbiological sampling of returned Surveyor 3 electrical cabling

A piece of electrical wiring bundle running from the television camera to another part of the spacecraft was selected for microbiological examination. Sampling methods are discussed. The results presented show that no viable microorganisms were recovered from the part of the Surveyor 3 cable which was tested. Factors that could have contributed to the sterility of the cable are thermal vacuum testing, natural dieoff, change in pressure during launch, and lunar vacuum and temperature.

Knittel, M. D.↗

Reaction propagation test. Evaluation of the behavior of nonmetallic materials in hydrogen

Results of tests conducted to evaluate the behavior of nonmetallic materials in hydrogen are described. The reaction propagation test simulates the conditions resulting from the interaction of an electrical wire in an overload condition in contract with a material in the test medium. The test is designed to evaluate the behavior of a material subjected to an energy input (usually heat) sufficient to cause a reaction which propagates to consume larger quantities of the material. Ten nonmetallic materials were evaluated to establish baseline data on the behavior of nonmetallic materials in hydrogen and to characterize, on an initial basis, one mode of material failure considered to be a factor pertinent to the safe use of a material in hydrogen.

Smith, I. D.↗

Flammability control for electrical cables and connectors

Technique of covering fire-hazardous sections of electrical wiring with fireproof materials prevents fires from spreading in oxygen-enriched atmospheres and eliminates use of heavy metal enclosures. Materials used to cover potting on connectors and ground terminals are made from Teflon-coated Beta cloth and Fluorel, a nonflammable fully-saturated polymer.

Wick, W. O.↗

Design Modification of Electrophoretic Equipment

The improved design of a zone electrophoretic sampler is reported that can be used in mass screening for hemoglobin S, the cause of sickle cell anemia. Considered is a high voltage multicell cellulose acetate device that requires 5 to 6 minutes electrophoresis periods; cells may be activitated individually or simultaneously. A multisample hemoglobin applicator standardizes the amount of sample applied and transfers the homolysate to the electrical wires.

Reddick, J. M.↗

Direct thrust measurement of a 30-cm ion thruster

A direct thrust measurement of a 30-cm diameter ion thruster was accomplished by means of a laser interferometer thrust stand. The thruster was supported in a pendulum manner by three 3.65-m long wires. Electrical power was provided by means of 18 mercury filled pots. A movable 23-button planar probe rake was used to determine thrust loss due to ion beam divergence. Values of thrust, thrust loss due to ion beam divergence, and thrust loss due to multiple ionization were measured for ion beam currents ranging from 0.5 A to 2.5 A. Measured thrust values indicate an accuracy of approximately 1% and are in good agreement with thrust values calculated by indirect measurements.

Banks, B.↗

Direct thrust measurement of a 30-cm ion thruster

A direct thrust measurement of a 30-cm diameter ion thruster was accomplished by means of a laser interferometer thrust stand. The thruster was supported in a pendulum manner by three 3.65-m long wires. Electrical power was provided by means of 18 mercury filled pots. A movable 23-button planar probe rake was used to determine thrust loss due to ion beam divergence. Values of thrust, thrust loss due to ion beam divergence, and thrust loss due to multiple ionization were measured for ion beam currents ranging from 0.5 to 2.5 A. Measured thrust values indicate an accuracy of approximately 1% and are in good agreement with thrust values calculated by indirect measurements.

Banks, B.↗

NASA technology utilization house

Following systems and features, which are predicted to save approximately $20,000 in utility costs over twenty year period, are incorporated into single-level, contemporarily designed, energy efficient residential structure: solar heating and cooling; energy efficient appliances; water recycling; security, smoke, and tornado detectors; and flat conductor electrical wiring.

Source record↗

Nondestructive pull tester

Quality control of welded electric wires is improved with easy-to-use tool applying small constant pull force to weldment (typically less than one-twentieth force required to pull weld apart).

Levy, A.↗

Simple circuit monitors "third wire" in ac lines

Device detects interruption of ground connection in three-wire electrical equipment and shuts off ac power to prevent shock hazard. Silicon-controlled rectifiers detect floating ground, and deenergize optoelectric relays thereby breaking power connections. Circuit could be incorporated into hand tools, appliances, and other electrical equipment.

Kojima, T. T.↗

3-D Manipulator for Mass Spectrometer

Small mass-spectrometer specimens are positioned in three dimensions by manipulator that employs two bellows to provide vacuum seal and accommodate movement of specimen holder. Inner bellows and outer bellows accommodate vertical and horizontal motion, respectively. Y-axis movement is in and out of plane of page. Specimen-holder column is hollow so electrical wires can pass through it to specimen.

Cirner, J. C.↗