Search NASA⌕ Search

SEARCH · Search NASA

Results for “FINGER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Structures of CTCF–DNA complexes including all 11 zinc fingers

The CCCTC-binding factor (CTCF) binds tens of thousands of enhancers and promoters on mammalian chromosomes by means of its 11 tandem zinc finger (ZF) DNA-binding domain. In addition to the 12–15-bp CORE sequence, some of the CTCF binding sites contain 5' upstream and/or 3' downstream motifs. Here, we describe two structures for overlapping portions of human CTCF, respectively, including ZF1–ZF7 and ZF3–ZF11 in complex with DNA that incorporates the CORE sequence together with either 3' downstream or 5' upstream motifs. Like conventional tandem ZF array proteins, ZF1–ZF7 follow the right-handed twist of the DNA, with each finger occupying and recognizing one triplet of three base pairs in the DNA major groove. ZF8 plays a unique role, acting as a spacer across the DNA minor groove and positioning ZF9–ZF11 to make cross-strand contacts with DNA. We ascribe the difference between the two subgroups of ZF1–ZF7 and ZF8–ZF11 to residues at the two positions -6 and -5 within each finger, with small residues for ZF1–ZF7 and bulkier and polar/charged residues for ZF8–ZF11. ZF8 is also uniquely rich in basic amino acids, which allows salt bridges to DNA phosphates in the minor groove. Highly specific arginine–guanine and glutamine–adenine interactions, used to recognize G:C or A:T base pairs at conventional base-interacting positions of ZFs, also apply to the cross-strand interactions adopted by ZF9–ZF11. The differences between ZF1–ZF7 and ZF8–ZF11 can be rationalized structurally and may contribute to recognition of high-affinity CTCF binding sites.

59 BASIC BIOLOGICAL SCIENCES↗

Controlling Viscous Fingering Using Time-Dependent Strategies

Control and stabilization of viscous fingering of immiscible fluids impacts a wide variety of pressure-driven multiphase flows. Here, we report theoretical and experimental results on time-dependent control strategy by manipulating the gap thickness b(t) in a lifting Hele-Shaw cell in the power-law form b(t) = b 1 t 1/7 . Experimental results show good quantitative agreement with the predictions of linear stability analysis. Furthermore, by choosing the value of a single time-independent control parameter we can either totally suppress the viscous fingering instability or maintain a series of non-splitting viscous fingers during the fluid displacement process. Besides the gap thickness of a Hele-Shaw cell, in principle, time-dependent control strategies can also be placed on the injection rate, viscosity of the displaced fluid, and interfacial tensions between the two fluids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structures of three members of Pfam PF02663 (FmdE) implicated in microbial methanogenesis reveal a conserved α + β core domain and an auxiliary C-terminal treble-clef zinc finger

Examination of the genomic context for members of the FmdE Pfam family (PF02663), such as the protein encoded by the fmdE gene from the methanogenic archaeon Methanobacterium thermoautotrophicum, indicates that 13 of them are co-transcribed with genes encoding subunits of molybdenum formylmethanofuran dehydrogenase (EC 1.2.99.5), an enzyme that is involved in microbial methane production. Here, the first crystal structures from PF02663 are described, representing two bacterial and one archaeal species: B8FYU2_ DESHY from the anaerobic dehalogenating bacterium Desulfitobacterium hafniense DCB-2, Q2LQ23_SYNAS from the syntrophic bacterium Syntrophus aciditrophicus SB and Q9HJ63_THEAC from the thermoacidophilic archaeon Thermoplasma acidophilum. Two of these proteins, Q9HJ63_THEAC and Q2LQ23_SYNAS, contain two domains: an N-terminal thioredoxin-like + core domain (NTD) consisting of a five-stranded, mixed -sheet flanked by several -helices and a C-terminal zinc-finger domain (CTD). B8FYU2_ DESHY, on the other hand, is composed solely of the NTD. The CTD of Q9HJ63_THEAC and Q2LQ23_SYNAS is best characterized as a treble-clef zinc finger. Two significant structural differences between Q9HJ63_THEAC and Q2LQ23_SYNAS involve their metal binding. First, zinc is bound to the putative active site on the NTD of Q9HJ63_THEAC, but is absent from the NTD of Q2LQ23_SYNAS. Second, whereas the structure of the CTD of Q2LQ23_SYNAS shows four Cys side chains within coordination distance of the Zn atom, the structure of Q9HJ63_THEAC is atypical for a treble-cleft zinc finger in that three Cys side chains and an Asp side chain are within coordination distance of the zinc.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-171: Evaluation of the Analytical Anisotropic Algorithm in a Small Finger Joint Phantom Using Monte Carlo Simulation

Purpose: This study investigated the performance of the anisotropic analytical algorithm (AAA) in dose calculation in radiotherapy concerning a small finger joint. Monte Carlo simulation (EGSnrc code) was used in this dosimetric evaluation. Methods: Heterogeneous finger joint phantom containing a vertical water layer (bone joint or cartilage) sandwiched by two bones with dimension 2 × 2 × 2 cm{sup 3} was irradiated by the 6 MV photon beams (field size = 4 × 4 cm{sup 2}). The central beam axis was along the length of the bone joint and the isocenter was set to the center of the joint. The joint width and beam angle were varied from 0.5–2 mm and 0°–15°, respectively. Depth doses were calculated using the AAA and DOSXYZnrc. For dosimetric comparison and normalization, dose calculations were repeated in water phantom using the same beam geometry. Results: Our AAA and Monte Carlo results showed that the AAA underestimated the joint doses by 10%–20%, and could not predict joint dose variation with changes of joint width and beam angle. The calculated bone dose enhancement for the AAA was lower than Monte Carlo and the depth of maximum dose for the phantom was smaller than that for the water phantom. From Monte Carlo results, there was a decrease of joint dose as its width increased. This reflected the smaller the joint width, the more the bone scatter contributed to the depth dose. Moreover, the joint dose was found slightly decreased with an increase of beam angle. Conclusion: The AAA could not handle variations of joint dose well with changes of joint width and beam angle based on our finger joint phantom. Monte Carlo results showed that the joint dose decreased with increase of joint width and beam angle. This dosimetry comparison should be useful to radiation staff in radiotherapy related to small bone joint.

60 APPLIED LIFE SCIENCES↗

Vasomotion in Human Fingers

Introduction: We describe methods by which vasomotion can be recorded in awake and anesthetized human subjects without significant interference from other spontaneous vascular oscillations. Methods: In three separate studies, we used photoplethysmography (PPG) to record vasomotion in fingertips. In Study 1, we induced chemical sympathectomy in the studied hand of 11 awake subjects who received intravenous dexmedetomidine infusions. In Study 2, we administered four progressively increasing intravenous dexmedetomidine infusions to 16 awake volunteers. In Study 3, we recorded vasomotion simultaneously from 6 fingers of 7 patients who were under dexmedetomidine-based anesthesia. Five-minute epochs of PPG recordings that displayed slow vascular oscillations were analyzed for frequency and amplitude. Results: In Study 1, vasomotion frequencies were 0.025 ± 0.008 Hz. In Study 2, vasomotion frequencies were 0.033 ± 0.006 Hz, and 0.032 ± 0.008 Hz during the two highest dexmedetomidine infusion steps. In Study 3, vasomotion frequencies ranged from 0.020 to 0.037 Hz and were observed in all 6 fingers, with no synchrony between the six fingers. Conclusion: The vascular oscillations we observed without significant interference from other spontaneous oscillations are independent of neural activity (Study 1), local in nature (Study 3), and associated with alpha-2-adrenoceptor activation, consistent with known properties of vasomotion.

Cardiovascular System & Cardiology↗

Finger recording electrode system for electrical impedance plethysmograph

System facilitates location of recording electrodes of impedance plethysmograph that is used for measuring flow of blood in finger segment; electrodes can be relocated accurately and volume of finger segment under study can be determined precisely. System minimizes movement artifacts in plethysmograph trace because finger segment is held firmly.

Montgomery, L. D.↗

Effect of ambient temperature on the thermal profile of the human forearm, hand, and fingers

Forearm, hand, and finger skin temperatures were measured on the right and left sides of seven resting men. The purpose was to determine the bilateral symmetry of these segmental temperature profiles at ambient temperatures from 10 to 45 C. Thermistors placed on the right and left forearms, hands, and index fingers were used to monitor the subjects until equilibration was reached at each ambient temperature. Additionally, thermal profiles of both hands were measured with copper-constantan thermocouples. During one experimental condition (23 C ambient), rectal, ear canal, and 24 skin temperatures were measured on each subject. Average body and average skin temperatures are given for each subject at the 23 C ambient condition. Detailed thermal profiles are also presented for the dorsal, ventral, and circumferential left forearm, hand, and finger skin temperatures at 23 C ambient. No significant differences were found between the mean skin temperatures of the right and left contralateral segments at any of the selected ambient temperatures.

Montgomery, L. D.↗

An electrode system for tetrapolar electrical impedance plethysmography of the finger

A rigid band electrode system is described which facilitates location of the recording electrodes of a tetrapolar impedance plethysmograph used for measuring pulsations of blood in a finger segment. The electrodes can be relocated accurately, and the volume of the finger segment under study can be precisely defined. The new system ensures good electrical contact and minimizes movement artifacts in the plethysmograph trace by holding the finger segment in a firm position.

Montgomery, L. D.↗

Dendrites, viscous fingers, and the theory of pattern formation

Recent developments in the theory of pattern formation in dendritic crystal growth and viscous fingering in fluids are reviewed. Consideration is given to the discovery that weak capillary forces act as singular perturbations which lead to selection mechanisms in dendritic crystal growth and fingering patterns. Other topics include the conventional thermodynamic model of the solidification of a pure substance from its melt, fingering instability, pattern selection, the solvability theory, dendritic growth rates, the bubble effect discovered by Couder et al. (1986), the dynamics of pattern-forming systems, and snowflake formation.

Langer, J. S.↗

Prosthetic Hand With Two Gripping Fingers

Prosthetic hand developed for amputee who retains significant portion of forearm. Outer end of device is end effector including two fingers, one moved by rotating remaining part of forearm about its longitudinal axis. Main body of end effector is end member supporting fingers, roller bearing assembly, and rack-and-pinion mechanism. Advantage of rack-and-pinion mechanism enables user to open or close gap between fingers with precision and force.

Norton, William E.↗

Instrumented Glove Measures Positions Of Fingers

Glove instrumented with flat membrane potentiometers to obtain crude measurements of relative positions of fingers. Resistance of each potentiometer varies with position of associated finger; translator circuit connected to each potentiometer converts analog reading to 1 of 10 digital levels. Digitized outputs from all fingers fed to indicating, recording, and/or data-processing equipment. Gloves and circuits intended for use in biomedical research, training in critical manual tasks, and other specialized applications.

Bozeman, Richard J., Jr.↗

Man-equivalent telepresence through four fingered human-like hand system

The author describes a newly developed mechanical hand system. The robot hand is in human-like configuration with a thumb and three fingers, a palm, a wrist, and the forearm in which the hand and wrist actuators are located. Each finger and the wrist has its own active electromechanical compliance system, allowing the joint drive trains to be stiffened or loosened. This mechanism imitates the human muscle dual function of positioner and stiffness controller. This is essential for soft grappling operations. The hand-wrist assembly has 16 finger joints, three wrist joints, and five compliance mechanisms for a total of 24 degrees of freedom. The strength of the hand is roughly half that of the human hand and its size is comparable to a male hand. The hand is controlled through an exoskeleton glove controller that the operator wears. The glove provides the man-machine interface in telemanipulation control mode: it senses the operator's inputs to guide the mechanical hand in hybrid position and force control. The hand system is intended for dexterous manipulations in structured environments. Typical applications will include work in hostile environment such as space operations and nuclear power plants.

Jau, Bruno M.↗

Piezoelectric Actuators On A Cold Finger

Developmental system for active suppression of vibrations of cold finger includes three piezoelectric actuators bonded to outer surface. Actuators used to suppress longitudinal and lateral vibrations of upper end of cold finger by applying opposing vibrations. Cold finger in question is part of a cryogenic system associated with an infrared imaging detector. When fully developed, system would be feedback sensor/control/actuator system automatically adapting to changing vibrational environment and suppresses pressure-induced vibrations by imposing compensatory vibrations via actuators.

Kuo, Chin-Po↗

Finger-Circumference-Measuring Device

Easy-to-use device quickly measures circumference of finger (including thumb) on human hand. Includes polytetrafluoroethylene band 1/8 in. wide, bent into loop and attached to tab that slides on scale graduated in millimeters. Sliding tab preloaded with constant-force tension spring, which pulls tab toward closure of loop. Designed to facilitate measurements at various points along fingers to obtain data for studies of volumetric changes of fingers in microgravity. Also used in normal Earth gravity studies of growth and in assessment of diseases like arthritis.

Le, Suy↗

Pressure Balanced, Low Hysteresis Finger Seal Test Results

The purpose of this presentation is to demonstrate: low cost photoetching fabrication technique; pressure balanced finger seal design; and finger seal operation. The tests and analyses includes: finger seal air leakage analysis; rotor-run out and endurance tests; and extensive analytical work and rig testing.

Arora, Gul K.↗

High-Speed, High-Temperature Finger Seal Test Results

Finger seals have significantly lower leakage rates than conventional labyrinth seals used in gas turbine engines and are expected to decrease specific fuel consumption by over 1 percent and to decrease direct operating cost by over 0.5 percent. Their compliant design accommodates shaft growth and motion due to thermal and dynamic loads with minimal wear. The cost to fabricate these finger seals is estimated to be about half the cost to fabricate brush seals. A finger seal has been tested in NASA's High Temperature, High Speed Turbine Seal Test Rig at operating conditions up to 1200 F, 1200 ft/s, and 75 psid. Static, performance and endurance test results are presented. While seal leakage and wear performance are acceptable, further design improvements are needed to reduce the seal power loss.

Proctor, Margaret P.↗

Efficacy of Wrist/Palm Warming as an EVA Countermeasure to Maintain Finger Comfort in Cold Conditions During EVA

This study explored the effectiveness of local wrist/palm warming as a potential countermeasure for providing finger comfort during extended duration EVA. Methods: Six subjects (5 males and 1 female) were evaluated in a sagitally divided liquid cooling/warming garment (LCWG) with modified liquid cooling/warming (LCW) gloves in three different experimental conditions. Condition 1: Stage 1- no LCWG; chamber adaptation with LCW glove inlet water temperature 33 C; Stage 2-LCW glove inlet water temperature cooled to 8 C; Stage 3-LCW glove inlet water temperature warmed to 45 C; Condition 2: Stage1-LCWG and LCW glove inlet water temperature 33 C; Stage 2-LCWG inlet temperature cooled to 31 C, LCW gloves, 8 C; Stage 3-LCWG inlet water temperature remains at 31 C, LCW glove inlet water temperature warmed to 45 C; Condition 3: Stage l -LCWG and LCW gloves 33 C; Stage 2-LCWG inlet water temperature cooled to 28 C, LCW gloves, 8 C; Stage 3-LCWG remains at 28 C, LCW glove water temperature warmed to 45 C. Results: Wrist/palm area warming significantly increased finger temperature (Tfing) and blood perfusion in Stage 3 compared to Stage 2. The LCW gloves were most effective in increasing Stage 3 Tfing in Condition 1; and in increasing blood perfusion in Conditions 1 and 2 compared to Condition 3. Ratings of subjective perception of heat in the hand and overall body heat were higher at Stage 3 than Stage 2, with no significant differences across Conditions. Conclusions: Local wrist/palm warming was effective in increasing blood circulation to the distal extremities, suggesting the potential usefulness of this technique for increasing astronaut thermal comfort during EVA while decreasing power requirements. The LCW gloves were effective in heating the highly cooled fingers when the overall body was in a mild heat deficit.

Koscheyev, Victor S.↗

Two-Finger EKG Method of Detecting Evasive Responses

A system based on acquisition and processing of electrocardiographic (EKG) signals from two fingers has been proposed as a means of determining whether a person is answering questions evasively. The system -- in effect, a "lie detector" of sorts, would be used to gauge prospective passengers responses to questions at airport security checkpoints. The person to be interrogated would be required to put one finger from each hand onto two metal strips on a counter and would be instructed to relax and wait for the system to indicate that it is ready. Then a security person would ask the passenger a set of standard security questions. EKG signals acquired through contact with the fingers would be processed by an algorithm that would extract a single-value measure of the level of stress in the interrogated person. This measure would be used to determine whether the system should display a green or a red light to signify that the person is or is not, respectively, telling the truth. It has also been conjectured that the system may be useful for communicating with a person who is in a coma and, hence, unable to speak.

Oldham, Daniel↗