Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

Elucidating the Role of Hydroxide Electrolyte on Anion-Exchange-Membrane Water Electrolyzer Performance

Many solid-state devices, especially those requiring anion conduction, often add a supporting electrolyte to enable efficient operation. The prototypical case is that of anion-exchange-membrane water electrolyzers (AEMWEs), where addition of an alkali metal solution improves performance. However, the specific mechanism of this performance improvement is currently unknown. This work investigates the functionality of the alkali metal solution in AEMWEs using experiments and mathematical models. The results show that additional hydroxide plays a key role not only in ohmic resistance of the membrane and catalyst layer but also in the reaction kinetics. The modeling suggests that the added liquid electrolyte creates an additional electrochemical interface with the electrocatalyst that provides ion-transport pathways and distributes product gas bubbles; the total effective electrochemical active surface area in the cell with 1 M KOH is 5 times higher than that of the cell with DI water. In the cell with 1 M KOH, more than 80% of the reaction current is associate with the liquid electrolyte. These results indicate the importance of high pH of electrolyte and catalyst/electrolyte interface in AEMWEs. The understanding of the functionality of the alkali metal solution presented in this study should help guide the design and optimization of AEMWEs.

25 ENERGY STORAGE↗

High temperature water electrolysis testing of gold-based electrodes for H 2 production

The Hybrid Sulfur (HyS) process is a promising thermochemical water-splitting cycle with global scale hydrogen production potential. The SO 2 -depolarized electrolyzer (SDE) is a critical component of the cycle. At the core of the SDE is the membrane-electrode assembly (MEA), which consists of a polymer electrolyte membrane (PEM) sandwiched between two electrocatalyst layers. New electrocatalyst and membrane materials are being developed with the goals of improving the electrolyzer performance and extending the lifetime of the MEA. In this work, we evaluated the performance of three different membranes and optimized operating conditions, resulting is one of the highest performances in the literature.

08 HYDROGEN↗

Non-visual analysis of miniaturized melt wire arrays for in-pile measurement of peak irradiation temperature

As a part of the in-pile instrumentation program, the Idaho National Laboratory (INL) has established in-house capabilities to fabricate and test new advanced manufactured printed sensors for measurement of peak temperature inside the harsh environment of a nuclear test reactor. Although nuclear test reactors may use standard methods that can provide real-time temperature information, such as thermocouples, the need for feedthroughs for real-time measurements greatly increases the cost of the experiment. Some experiments also present the problem of limited space available for instrumentation. To address this need, INL is working to improve temperature detection options for such applications. The lab is developing advanced manufactured melt wire arrays to determine peak temperatures in experiments with limited space. Furthermore, capabilities to print multiple melt wires with different melting properties on a single miniaturized unit is being established. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing.

36 MATERIALS SCIENCE↗

Laser-based Adhesion Strength Measurements for Advanced Manufactured Sensor Adhesion Characterization

As part of the advanced manufacturing (AM) focus of the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) Program, new in-house capabilities to fabricate and test novel active and passive in-pile sensors are being developed at the Idaho National Laboratory (INL). These advanced-manufactured sensors, such as peak temperature monitors and strain gauges, must be miniaturized and be able to provide real-time feedback, all while withstanding the coupled extremes of temperature and radiation typically observed in the environment of a nuclear test reactor. Fabricating durable and robust in-pile sensors with high fidelity requires a fundamental understanding of the optimal process parameters required in the AM technique, as well as the effect of deviations from optimal process parameters on the sensor-substrate adhesion and the ultimate robustness of the sensor. This report presents the use of a laser-based, non-contact approach for characterizing the adhesion of sensors manufactured using aerosol jet printing (AJP) that comprise of silver nanoparticle inks deposited and sintered on austenitic stainless steel (SS) 316L substrates. The effect of substrate surface roughness, surface energy, ink sintering time and sintering temperature on the printed sensor topography and the sensor-substrate adhesion has been systematically investigated. The sensor-substrate interfacial adhesion strength was determined from the critical laser pulse energy required to ablate/ detach the printed sensor from the substrate. Measurements of the sensor topography using optical profilometry revealed that post-deposition sintering at 400°C for 60 minutes resulted in a reduced sensor thickness, while plasma treating the substrate prior to printing yielded sensors with uniform thickness profiles transverse to the print direction. Sintering temperature and time were found to be the dominant parameters that affected sensor-substrate adhesion, followed by substrate surface roughness. The laser-based and locally-destructive approach for adhesion strength measurements shows promise in overcoming the challenges and limitations of current standardized peel tests and can be developed into a post-fabrication process control protocol for evaluating the durability of AM printed sensors in a high throughput fashion. Future studies will investigate the use of laser-induced spallation techniques as well as non-destructive laser ultrasonic methods for sensor-substrate adhesion characterization on sensors manufactured using AJP and other AM techniques such as plasma jet printing (PJP).

42 ENGINEERING↗

Design Optimization for Printed Melt Wire Arrays Encapsulation

As part of the Nuclear Energy Enabling Technology (NEET) Advanced Sensor and Instrumentation (ASI) Program, Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced-manufactured sensors for measuring peak irradiation temperature within a nuclear test reactor. Although methods of real-time temperature monitoring, such as thermocouples, may be used, the complexity of feedthroughs and attachments to collect real-time measurements greatly increases the cost of the experiment. Instead, passive monitoring techniques may be used for peak- temperature measurement that exploit the melting point of well-characterized materials (standard melt wires) to infer peak reactor temperatures. However, limited available space for instrumentation during experiments introduces an additional challenge. To accommodate this, INL has expanded its temperature- detection instrumentation capabilities to include advanced manufactured (AM) melt wires for peak irradiation temperature measurements. These melt wires can determine peak temperatures while also accommodate space limitations in irradiation experiments. In an effort to improve performance reliability of AM meltwire capabilities, a process was developed and tested to identify the significance of entrapping a high purity inert atmosphere within the packaging of printed melt wire arrays. The materials used in this study were aluminum, zinc, and tin encapsulated in high purity helium within a stainless steel (SS) 316 container. Tin, with a low melting point of approximately 230°C, Zn with a mid-melting point of approximately 420°C, and Al with a high melting point of approximately 660°C. This report describes the design, fabrication process, furnace testing and X-ray Computed Tomography (XCT) evaluation. Results show a successful outcome in creating an inert gas encapsulation and high-resolution evaluation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Temperature Testing of Advanced Manufactured Melt Wire Package

As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 °C) and solder (melting temperature of ~160 °C), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bi-metallic Nanoparticle Synthesis for Advanced Manufactured Melt Wires

Science Undergraduate Laboratory Internship (SULI) Program Report: Additive manufacturing (AM) based on direct-write technologies has emerged as the predominant method for the fabrication of passive sensors for the harsh operating environments seen in a nuclear reactor. Through the modification of previous methods, Idaho National Laboratory and Villanova University have improved the synthesis process for AM feedstock, which will allow for the improvement of advanced nuclear sensors and instrumentation. A major part of this work includes the synthesis process of relevant AM compatible feedstock to support the development, fabrication, and testing of AM sensors for peak temperature detection. For this report, bismuth, bismuth/platinum, tin, tin/silver, tin/zinc, indium, and indium/silver bi-metallic nanoparticles were synthesized using the polyol method, which will enhance temperature sensitivity and allow for miniaturization. To characterize the synthesized nanoparticles, we used x-ray fluorescence to evaluate the elemental composition of the nanoparticles and differential scanning calorimetry and thermogravimetric analysis to determine the melting point and mass loss of the samples. Results show that bi-metallic nanoparticles are a viable option for the fabrication of high-resolution AM melt wires. The temperature sensitivity can be brought to within 5°C and melt wires can be fabricated that are in the micrometer scale. This will expand the range of irradiation experiments melt wires can be used for and the measured temperature will be significantly more accurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Quality Control Methods for Robust and Reliable Sensor Design

The successful adoption of additive manufacturing for the rapid prototyping of printed sensors requires the establishment of quantifiable metrics that can interrogate device performance. One measure of performance is the adhesion strength between the substrate and sensor interface, which is critical since the strength of this interface can dictate the accuracy and reliability of the printed sensor. In this work, a non-contact laser-induced spallation technique was used to quantify the adhesion of silver prints on an aluminum alloy substrate. The laser-based method was compared to a standardized pull-off adhesion test, which provided baseline measurements of adhesion strength. The sintering conditions were shown to play an important role in the film-substrate adhesion strength, as well as the cohesion and ductility of the film itself. The methods and results described in this work supports the establishment of process control steps that are necessary for verifying the reliability of printed devices prior to its deployment in critical experiments.

36 MATERIALS SCIENCE↗

Summary of GAIN BWR Off-Gas Study: Effect of Charcoal on Kr and Xe Delay

This is a summary of a more extensive report, written in collaboration with the GE-Hitachi BWR Owner's Group, detailing a study of BWR off-gas treatment. The study determined that aged charcoal continues to be effective for the delay of Kr and Xe through BWR off-gas treatment systems. It demonstrates the over-sized nature of existing charcoal beds, and highlights potential areas of improvement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Xe Concentration Activity

INL conducted extensive studies to understand how the Xe capacity of AgZ-PAN changes under various conditions including flowrate, temperature, concentration, carrier gas, and irradiation of the sorbent. Therefore, it is well understood that AgZ-PAN can capture Xe under a wide range of conditions. While these studies were performed to prove that Xe can be completely desorbed from the column, the ability to concentrate Xe during desorption was not studied. Concentrating Xe during desorption would be ideal so as to produce Xe that can be used for commercial and research applications. This report investigates the Xe concentrating potential of AgZ-PAN by running multiple Xe adsorption-desorption cycles, collecting the desorbed effluent from a saturated AgZ-PAN column, and then loading it onto a fresh column.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗