Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fiber Bundle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Performance Comparison of Object Detection Networks for Shrapnel Identification in Ultrasound Images

Ultrasound imaging is a critical tool for triaging and diagnosing subjects but only if images can be properly interpreted. Unfortunately, in remote or military medicine situations, the expertise to interpret images can be lacking. Machine-learning image interpretation models that are explainable to the end user and deployable in real time with ultrasound equipment have the potential to solve this problem. We have previously shown how a YOLOv3 (You Only Look Once) object detection algorithm can be used for tracking shrapnel, artery, vein, and nerve fiber bundle features in a tissue phantom. However, real-time implementation of an object detection model requires optimizing model inference time. Here, we compare the performance of five different object detection deep-learning models with varying architectures and trainable parameters to determine which model is most suitable for this shrapnel-tracking ultrasound image application. We used a dataset of more than 16,000 ultrasound images from gelatin tissue phantoms containing artery, vein, nerve fiber, and shrapnel features for training and evaluating each model. Every object detection model surpassed 0.85 mean average precision except for the detection transformer model. Overall, the YOLOv7tiny model had the higher mean average precision and quickest inference time, making it the obvious model choice for this ultrasound imaging application. Other object detection models were overfitting the data as was determined by lower testing performance compared with higher training performance. In summary, the YOLOv7tiny object detection model had the best mean average precision and inference time and was selected as optimal for this application. Next steps will implement this object detection algorithm for real-time applications, an important next step in translating AI models for emergency and military medicine.

60 APPLIED LIFE SCIENCES↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Upgrades to the Thomson Scattering Diagnostic on the Lithium Tokamak eXperiment-Beta (LTX-$β$)

We describe the upgrades to the Thomson scattering (TS) diagnostic on the Lithium Tokamak eXperiment-beta (LTX- β ) to provide complete radial coverage of the plasma. LTX- β is a spherical tokamak with plasma limited at a major radius of R = 14 cm and R = 66 cm. Flat temperature profiles with peaked density were observed in LTX- β using an existing multipoint TS diagnostic with radial coverage of the plasma core. There is a need for more comprehensive core and edge TS measurements to thoroughly examine beam fueling, beam heating, and transport under low recycling conditions with liquid lithium walls and a lower collisionality scrape-off layer (SOL). The core TS set up provides plasma profiles from R = 40–60 cm. To extend the TS diagnostic coverage: 1) we added a TS viewing optics to cover the SOL region at five radial points from R = 57–64 cm, and 2) another TS viewing optics in the HFS region from R = 15–45 cm to obtain TS data from ten radial positions while making use of the original laser beam. The main focus of this article is on the new HFS TS setup that is equipped with better-matched collection optics located in the horizontal midplane where the laser polarization lies and views from a scattering angle of 130°–150° with respect to the laser path. A set of unequal-length Y-branched fiber bundles transports the TS light from two radial points to each polychromator. The new HFS view is better matched in spot size, scattering angle, and throughput to the laser and polychromators and has new V-grooved style viewing dumps. The new HFS TS view, along with the core and SOL TS views, will provide a full radial measurement coverage from R = 15–64 cm to explore the flat temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrasonic Fiber Waveguides for Measuring Spatially Distributed Environmental and Material Properties

We report using carbon fibers (<100 μm in diameter) as ultrasonic waveguides to measure spatial changes in the environment and material properties. We connected carbon fibers of different lengths to an ultrasonic transducer and measured changes in the times of flight in a pulse-echo mode in response to elevated temperatures. By simultaneously interrogating multiple fibers of different lengths and collectively analyzing the time of flight in each fiber, we demonstrated dynamic measurements of the temperature distribution along the fiber bundle during their heating.

Walton, Kenneth↗

DISCO GUI v.1

SAND2024-08619O The DISCO GUI software, written in MATLAB, allows for data calibration for X-ray diffraction work at Sandia National Labs’ Z Machine. The program manually identifies and manipulates images from seven fiber bundles based on a calibration reticle. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Smith, Anthony↗

Evaluation of a fiber-coupled x-ray diffraction detector for dynamic compression experiments

The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of critical defects in ablative heat shield systems for the space shuttle

Results are presented from an investigation to determine the effects of fabrication-induced defects on the performance of an ablative heat shield material in a simulated space shuttle reentry environment. Nondestructive methods for detecting the defects were investigated. The material considered is a fiber-filled, honeycomb-reinforced, low-density elastomer. Results were obtained for density variations, voids, fiber bundles, crushed honeycomb, undercut honeycomb, unbonded areas, face sheet delaminations, and cure variations. The data indicate that, within reasonable tolerances, the fabrication defects investigated are not critical in terms of reentry performance of the heat shield.

Thompson, R. L.↗

Design of an optical fiber cable link for lightning instrumentation

A lightning instrumentation system was designed to record current magnitudes of lightning strikes that hit a launch pad service structure at NASA's Kennedy Space Center. The instrumentation system consists of a lightning ground rod with a current sensor coil, an optical transmitter, an optical fiber cable link, a detector receiver, and a recording system. The transmitter is a wideband pulse transformer driving an IR LED emitter. The transmitter operates linearly as a transducer. A low loss fiber bundle provides isolation of the recorder system from the electromagnetic field of the lightning strike. The output of an optical detector receiver module is sampled and recorded in digital format. The significant factors considered in the design were dynamic range, linearity, mechanical configuration, electromagnetic isolation, and temperature compensation.

Grove, C. H.↗

Fiber-optics couple arthroscope to TV

Convenient, hand-held coupler images output of arthroscope onto coherent fiber bundle. Arthroscope allows surgeons to examine internal organs through any small opening in body. Coupler is also used for engine inspection, instrument repair, and around-corner visual inspection. Image from arthroscope travels along flexible bundle and appears at other cable end where it is recollimated by lens. Image is read from lens or projected on color TV camera.

Franke, J. M.↗

The Shuttle tile story

The structural problems associated with the reusable thermal protection system (TPS) of the Space Shuttle Orbiter are assessed. The ceramic insulation was placed on the aluminum in the form of about 30,000 tiles over approximately 70% of the Orbiter's exterior. The tiles were bonded to felt pads, and then the tile-pad structure was attached to the aluminum skin. As Orbiter design progressed, it was discovered that the TPS would have to withstand loads greater than initially predicted. The group tensile strength was less than that of the individual components. This was the primary factor contributing to the delay of the first flight. Values are given for Orbiter isotherms during a normal flight as well as the corresponding TPS distribution. The complete TPS assemblage is shown schematically, noting the sequence of assembling the tile components into a testing specimen. It is noted that tensile loads are applied to the strain-isolation path at discrete regions along transverse fiber bundles, causing a 50% reduction in system tensile strength. Procedures for strengthening the interface between the insulation and strain-isolation path are discussed and flight-simulation tests are outlined.

Cooper, P. A.↗

Solventless Fabrication of Reinforced Composites

Heat and pressure melt thermoplastic fibers, causing them to flow into voids around graphite reinforcement. On cooling, fiber bundle has been transformed into structural composite. Required temperature and pressure depend on properties of particular thermoplastic used.

Baucom, R. M.↗

Optical tip clearance sensor for aircraft engine controls

Aircraft gas turbine performance and efficiency are related to airfoil tip clearance. The possibility has been considered to obtain optimum performance and efficiency by reducing clearance to a safe minimum with the aid of a closed-loop tip clearance control system, which utilizes a tip clearance sensor. The use of optical sensing methods appears to represent a potential solution to the tip clearance measurement problem. Principles of sensor operation are discussed along with dimensional considerations and diffraction limitations. A description is presented of the study of the feasibility of a certain sensor, taking into account the test rig system, the optical components, and the mounting tube. Attention is also given to the operation of the feasibility-study sensor, performance estimations, the optical fiber bundle, light beam refraction, and aspects of aircraft engine implementation.

Poppel, G. L.↗

Robotic Vision for Welding

Vision system for robotic welder looks at weld along axis of welding electrode. Gives robot view of most of weld area, including yet-unwelded joint, weld pool, and completed weld bead. Protected within welding-torch body, lens and fiber bundle give robot closeup view of weld in progress. Relayed to video camera on robot manipulator frame, weld image provides data for automatic control of robot motion and welding parameters.

Richardson, R. W.↗

Autoclave processing for composite material fabrication. 1: An analysis of resin flows and fiber compactions for thin laminate

High quality long fiber reinforced composites, such as those used in aerospace and industrial applications, are commonly processed in autoclaves. An adequate resin flow model for the entire system (laminate/bleeder/breather), which provides a description of the time-dependent laminate consolidation process, is useful in predicting the loss of resin, heat transfer characteristics, fiber volume fraction and part dimension, etc., under a specified set of processing conditions. This could be accomplished by properly analyzing the flow patterns and pressure profiles inside the laminate during processing. A newly formulated resin flow model for composite prepreg lamination process is reported. This model considers viscous resin flows in both directions perpendicular and parallel to the composite plane. In the horizontal direction, a squeezing flow between two nonporous parallel plates is analyzed, while in the vertical direction, a poiseuille type pressure flow through porous media is assumed. Proper force and mass balances have been made and solved for the whole system. The effects of fiber-fiber interactions during lamination are included as well. The unique features of this analysis are: (1) the pressure gradient inside the laminate is assumed to be generated from squeezing action between two adjacent approaching fiber layers, and (2) the behavior of fiber bundles is simulated by a Finitely Extendable Nonlinear Elastic (FENE) spring.

Hou, T. H.↗

Side-Looking Viewer for Crevices

Side-looking optical viewer inserted into gap 1 mm wide to depth of 10 cm. Instrument allows human observer to inspect small crevices from comfortable viewing angle. Small mirror atop pair of thin, flat legs inserted into gap. Mirror reflects image of gap wall or other object into microscope, which magnifies image 20 times. Quartz/halogen lamp in separate unit provides light to illuminate gap via optical-fiber bundle. Observer looks directly through microscope or attaches photographic or video camera without disturbing setup.

Hagen, G. R.↗

Image Control In Automatic Welding Vision System

Orientation and brightness varied to suit welding conditions. Commands from vision-system computer drive servomotors on iris and Dove prism, providing proper light level and image orientation. Optical-fiber bundle carries view of weld area as viewed along axis of welding electrode. Image processing described in companion article, "Processing Welding Images for Robot Control" (MFS-26036).

Richardson, Richard W.↗

Optical-Fiber Temperature Sensor

Temperature measured in rotating machinery without speed-limiting mechanical sliprings. Gap widens as temperature rises and narrows as temperature falls. Light reflected from piston face and recaptured by fiber bundle varies accordingly.

Roschak, Edmund J.↗

IR optical fiber-based noncontact pyrometer for drop tube instrumentation

The design of a two color pyrometer with infrared optical fiber bundles for collection of the infrared radiation is described. The pyrometer design is engineered to facilitate its use for measurement of the temperature of small, falling samples in a microgravity materials processing experiment using a 100 meter long drop tube. Because the samples are small and move rapidly through the field of view of the pyrometer, the optical power budget of the detection system is severly limited. Strategies for overcoming this limitation are discussed.

May, R. G.↗