Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow path”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

Development of the Circulation Control Flow Scheme Used in the NTF Semi-Span FAST-MAC Model

The application of a circulation control system for high Reynolds numbers was experimentally validated with the Fundamental Aerodynamic Subsonic Transonic Modular Active Control semi-span model in the NASA Langley National Transonic Facility. This model utilized four independent flow paths to modify the lift and thrust performance of a representative advanced transport type of wing. The design of the internal flow paths highlights the challenges associated with high Reynolds number testing in a cryogenic pressurized wind tunnel. Weight flow boundaries for the air delivery system were identified at mildly cryogenic conditions ranging from 0.1 to 10 lbm/sec. Results from the test verified system performance and identified solutions associated with the weight-flow metering system that are linked to internal perforated plates used to achieve flow uniformity at the jet exit.

Jones, Gregory S.↗

Rotating-Pump Design Code

Pump Design (PUMPDES) is a computer program for designing a rotating pump for liquid hydrogen, liquid oxygen, liquid nitrogen, water, methane, or ethane. Using realistic properties of these fluids provided by another program called GASPAK, this code performs a station-by-station, mean-line analysis along the pump flow path, obtaining thermodynamic properties of the pumped fluid at each station and evaluating hydraulic losses along the flow path. The variables at each station are obtained under constraints that are consistent with the underlying physical principles. The code evaluates the performance of each stage and the overall pump. In addition, by judiciously choosing the givens and the unknowns, the code can perform a geometric inverse design function: that is, it can compute a pump geometry that yields a closest approximation of given design point. The code contains two major parts: one for an axial-rotor/inducer and one for a multistage centrifugal pump. The inducer and the centrifugal pump are functionally integrated. The code can be used in designing and/or evaluating the inducer/centrifugal-pump combination or the centrifugal pump alone. The code is written in standard Fortran 77.

Walker, James F.↗

Thermal Barrier/Seal for Extreme Temperature Applications

Large solid rocket motors, as found on the Space Shuttle, are fabricated in segments for manufacturing considerations, bolted together, and sealed using conventional Viton O-ring seals. Similarly the nine large solid rocket motor nozzles are assembled from several different segments, bolted together, and sealed at six joint locations using conventional O-ring seals. The 5500 F combustion gases are generally kept a safe distance away from the seals by thick layers of phenolic or rubber insulation. Joint-fill compounds, including RTV (room temperature vulcanized compound) and polysulfide filler, are used to fill the joints in the insulation to prevent a direct flow-path to the O-rings. Normally these two stages of protection are enough to prevent a direct flow-path of the 900-psi hot gases from reaching the temperature-sensitive O-ring seals. However, in the current design 1 out of 15 Space Shuttle solid rocket motors experience hot gas effects on the Joint 6 wiper (sacrificial) O-rings. Also worrisome is the fact that joints have experienced heat effects on materials between the RTV and the O-rings, and in two cases O-rings have experienced heat effects. These conditions lead to extensive reviews of the post-flight conditions as part of the effort to monitor flight safety. We have developed a braided carbon fiber thermal barrier to replace the joint fill compounds in the Space Shuttle solid rocket motor nozzles to reduce the incoming 5500 F combustion gas temperature and permit only cool (approximately 100 F) gas to reach the temperature-sensitive O-ring seals. Implementation of this thermal barrier provides more robust, consistent operation with shorter turn around times between Shuttle launches.

Steinetz, Bruce M.↗

Study of Critical Heat Flux and Two-Phase Pressure Drop Under Reduced Gravity

The design of the two-phase flow systems which are anticipated to be utilized in future spacecraft thermal management systems requires a knowledge of two-phase flow and heat transfer phenomena in reduced gravities. This program was funded by NASA headquarters in response to NRA-91-OSSA-17 and was managed by Lewis Research Center. The main objective of this program was to design and construct a two-phase test loop, and perform a series of normal gravity and aircraft trajectory experiments to study the effect of gravity on the Critical Heat Flux (CHF) and onset of instability. The test loop was packaged on two aircraft racks and was also instrumented to generate data for two-phase pressure drop. The normal gravity tests were performed with vertical up and downflow configurations to bound the effect of gravity on the test parameters. One set of aircraft trajectory tests was performed aboard the NASA DC-9 aircraft. These tests were mainly intended to evaluate the test loop and its operational performance under actual reduced gravity conditions, and to produce preliminary data for the test parameters. The test results were used to demonstrate the applicability of the normal gravity models for prediction of the two-phase friction pressure drop. It was shown that the two-phase friction multipliers for vertical upflow and reduced gravity conditions can be successfully predicted by the appropriate normal gravity models. Limited critical heat flux data showed that the measured CHF under reduced gravities are of the same order of magnitude as the test results with vertical upflow configuration. A simplified correlation was only successful in predicting the measured CHF for low flow rates. Instability tests with vertical upflow showed that flow becomes unstable and critical heat flux occurs at smaller powers when a parallel flow path exists. However, downflow tests and a single reduced gravity instability experiment indicated that the system actually became more stable with a parallel single-phase flow path. Several design modifications have been identified which will improve the system performance for generating reduced gravity data. The modified test loop can provide two-phase flow data for a range of operating conditions and can serve as a test bed for component evaluation.

Abdollahian, Davood↗

Development and Demonstration of an Ada Test Generation System

In this project we have built a prototype system that performs Feasible Path Analysis on Ada programs: given a description of a set of control flow paths through a procedure, and a predicate at a program point feasible path analysis determines if there is input data which causes execution to flow down some path in the collection reaching the point so that tile predicate is true. Feasible path analysis can be applied to program testing, program slicing, array bounds checking, and other forms of anomaly checking. FPA is central to most applications of program analysis. But, because this problem is formally unsolvable, syntactic-based approximations are used in its place. For example, in dead-code analysis the problem is to determine if there are any input values which cause execution to reach a specified program point. Instead an approximation to this problem is computed: determine whether there is a control flow path from the start of the program to the point. This syntactic approximation is efficiently computable and conservative: if there is no such path the program point is clearly unreachable, but if there is such a path, the analysis is inconclusive, and the code is assumed to be live. Such conservative analysis too often yields unsatisfactory results because the approximation is too weak. As another example, consider data flow analysis. A du-pair is a pair of program points such that the first point is a definition of a variable and the second point a use and for which there exists a definition-free path from the definition to the use. The sharper, semantic definition of a du-pair requires that there be a feasible definition-free path from the definition to the use. A compiler using du-pairs for detecting dead variables may miss optimizations by not considering feasibility. Similarly, a program analyzer computing program slices to merge parallel versions may report conflicts where none exist. In the context of software testing, feasibility analysis plays an important role in identifying testing requirements which are infeasible. This is especially true for data flow testing and modified condition/decision coverage. Our system uses in an essential way symbolic analysis and theorem proving technology, and we believe this work represents one of the few successful uses of a theorem prover working in a completely automatic fashion to solve a problem of practical interest. We believe this work anticipates an important trend away from purely syntactic-based methods for program analysis to semantic methods based on symbolic processing and inference technology. Other results demonstrating the practical use of automatic inference is being reported in hardware verification, although there are significant differences between the hardware work and ours. However, what is common and important is that general purpose theorem provers are being integrated with more special-purpose decision procedures to solve problems in analysis and verification. We are pursuina commercial opportunities for this work, and will use and extend the work in other projects we are engaged in. Ultimately we would like to rework the system to analyze C, C++, or Java as a key step toward commercialization.

Source record↗

Simplified, inverse, ejector design tool

A simple lumped parameter based inverse design tool has been developed which provides flow path geometry and entrainment estimates subject to operational, acoustic, and design constraints. These constraints are manifested through specification of primary mass flow rate or ejector thrust, fully-mixed exit velocity, and static pressure matching. Fundamentally, integral forms of the conservation equations coupled with the specified design constraints are combined to yield an easily invertible linear system in terms of the flow path cross-sectional areas. Entrainment is computed by back substitution. Initial comparison with experimental and analogous one-dimensional methods show good agreement. Thus, this simple inverse design code provides an analytically based, preliminary design tool with direct application to High Speed Civil Transport (HSCT) design studies.

Dechant, Lawrence J.↗

Thermo-Mechanical Processing in Friction Stir Welds

In Friction Stir Welding (FSW) a rotating pin-tool inserted into a weld seam literally stirs the edges of the seam together. In this study, two flow paths are proposed that define the FWS zone. Studies using a longitudinal tungsten wire (0.0025 dia.) were used to visualize and document the material flow. The material flow path is described using a mathematical model.

Schneider, J. A.↗

Gas-Tolerant Device Senses Electrical Conductivity of Liquid

The figure depicts a device for measuring the electrical conductivity of a flowing liquid. Unlike prior such devices, this one does not trap gas bubbles entrained in the liquid. Usually, the electrical conductivity of a liquid is measured by use of two electrodes immersed in the liquid. A typical prior device based on this concept contains large cavities that can trap gas. Any gas present between or near the electrodes causes a significant offset in the conductivity reading and, if the gas becomes trapped, then the offset persists. Extensive tests on two-phase (liquid/ gas) flow have shown that in the case of liquid flowing along a section of tubing, gas entrained in the liquid is not trapped in the section as long as the inner wall of the section is smooth and continuous, and the section is the narrowest tubing section along the flow path. The design of the device is based on the foregoing observation: The electrodes and the insulators separating the electrodes constitute adjacent parts of the walls of a tube. The bore of the tube is machined to make the wall smooth and to provide a straight flow path from the inlet to the outlet. The diameter of the electrode/insulator tube assembly is less than the diameter of the inlet or outlet tubing. An outer shell contains the electrodes and insulators and constitutes a leak and pressure barrier. Any gas bubble flowing through this device causes only a momentary conductivity offset that is filtered out by software used to process the conductivity readings.

O'Connor, Edward W.↗

Cooled Ceramic Matrix Composite Propulsion Structures Demonstrated

NASA's Next Generation Launch Technology (NGLT) Program has successfully demonstrated cooled ceramic matrix composite (CMC) technology in a scramjet engine test. This demonstration represented the world s largest cooled nonmetallic matrix composite panel fabricated for a scramjet engine and the first cooled nonmetallic composite to be tested in a scramjet facility. Lightweight, high-temperature, actively cooled structures have been identified as a key technology for enabling reliable and low-cost space access. Tradeoff studies have shown this to be the case for a variety of launch platforms, including rockets and hypersonic cruise vehicles. Actively cooled carbon and CMC structures may meet high-performance goals at significantly lower weight, while improving safety by operating with a higher margin between the design temperature and material upper-use temperature. Studies have shown that using actively cooled CMCs can reduce the weight of the cooled flow-path component from 4.5 to 1.6 lb/sq ft and the weight of the propulsion system s cooled surface area by more than 50 percent. This weight savings enables advanced concepts, increased payload, and increased range. The ability of the cooled CMC flow-path components to operate over 1000 F hotter than the state-of-the-art metallic concept adds system design flexibility to space-access vehicle concepts. Other potential system-level benefits include smaller fuel pumps, lower part count, lower cost, and increased operating margin.

Jaskowiak, Martha H.↗

Stemless Ball Valve

This invention utilizes a new method of opening and closing a ball valve. Instead of rotating the ball with a perpendicular stem (as is the case with standard ball valves), the ball is rotated around a fixed axis by two guide pins. This innovation eliminates the leak point that is present in all standard ball valves due to the penetration of an actuation stem through the valve body. The VOST (Venturi Off-Set-Technology) valve has been developed for commercial applications. The standard version of the valve consists of an off-set venturi flow path through the valve. This path is split at the narrowest portion of the venturi, allowing the section upstream from the venturi to be rotated. As this rotation takes place, the venturi becomes restricted as one face rotates with respect to the other, eventually closing off the flow path. A spring-loaded seal made of resilient material is embedded in the upstream face of the valve, making a leak-proof seal between the faces; thus a valve is formed. The spring-loaded lip seal is the only seal that can provide a class six, or bubble-tight, seal against the opposite face of the valve. Tearing action of the seal by high-velocity gas on this early design required relocation of the seal to the downstream face of the valve. In the stemless embodiment of this valve, inner and outer magnetic cartridges are employed to transfer mechanical torque from the outside of the valve to the inside without the use of a stem. This eliminates the leak path caused by the valve stems in standard valves because the stems penetrate through the bodies of these valves.

Burgess, Robert K.↗

Electrophoretic sample insertion

Two conductive screens located in the flow path of an electrophoresis sample separation apparatus are charged electrically. The sample is introduced between the screens, and the charge is sufficient to disperse and hold the samples across the screens. When the charge is terminated, the samples are uniformly distributed in the flow path. Additionally, a first separation by charged properties has been accomplished.

Mccreight, L. R.↗

Seeding Method for Velocimetry and Visualization of Supersonic Retropropulsion Nozzle Plumes

In the current work, the “Venturi seeder” method for nozzle plumes is improved and studied to determine suitability for particle image velocimetry. This seeding method involves independently pressurizing the primary flow path and a separate seed liquid reservoir, connecting them at the throat of a Venturi contraction upstream of the nozzle. The pressure differential at the throat causes the liquid to enter the nozzle channel where it is atomized into particles by strong shearing forces. This new seeding system was characterized by conducting a series of diagnostics using different exit nozzle pressure ratios and seed reservoir pressures. Shadowgraph imaging confirmed the nozzle plumes to be underexpanded jets. A particle sizing device determined that generated DEHS oil particles had median aerodynamic diameters of 0.67, 0.69, and 0.73 μm for seed liquid reservoir pressure supplies of 0.67, 0.60, and 0.93 MPa and primary flow path pressures of 0.67, 0.76, and 0.93 MPa measured downstream of the Venturi throat, respectively. These diameters were within the threshold for acceptable response time in typical gas flows (≤ 1 μm). PIV experiments were conducted on the nozzle plume for all presented cases; mean axial and transverse velocities appeared as expected for the underexpanded jet structure, including the Mach disk and re-acceleration regions. Additional sizing analysis based on the particle response times across the normal shock again showed particle diameters to be well less than 1 μm for all cases. The results suggest that this method is an inexpensive and relatively simple solution to the problem of seeding nozzle plumes. The method will be used in testing of supersonic retropropulsion models in the Unitary Plan Wind Tunnel at The NASA Langley Research Center in 2022.

particle image velocimetry↗

Turbulence Model Effects on RANS Simulations of the HIFiRE Flight 2 Ground Test Configurations

The Wind-US Reynolds-averaged Navier-Stokes solver was applied to the Hypersonic International Flight Research Experimentation (HIFiRE) Flight 2 scramjet ground test configuration. Two test points corresponding to flight Mach numbers of 5.9 and 8.9 were examined. The emphasis was examining turbulence model effects on the prediction of flow path pressures. Three variants of the Menter k-omega turbulence model family were investigated. These include the baseline (BSL) and shear stress transport (SST) as well as a modified SST model where the shear stress limiter was altered. Variations in the turbulent Schmidt number were also considered. Choice of turbulence model had a substantial effect on prediction of the flow path pressures. The BSL model produced the highest pressures and the SST model produced the lowest pressures. As expected, the settings for the turbulent Schmidt number also had significant effects on predicted pressures. Small values for the turbulent Schmidt number enabled more rapid mass transfer, faster combustion, and in turn higher flowpath pressures. Optimal settings for turbulence model and turbulent Schmidt number were found to be rather case dependent, as has been concluded in other scramjet investigations.

Georgiadis, Nicholas J.↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

Providing adequate carbon dioxide (CO2) washout is essential to the reduction of risk in performing suited operations. Long term CO2 exposure can lead to symptoms such as headache, lethargy, dizziness, and in severe cases can lead to unconsciousness and death. Thus maintaining adequate CO2 washout in both ground testing and during in flight EVAs is a requirement of current and future suit designs. It is necessary to understand the inspired CO2 of suit wearers such that future requirements for space suits appropriately address the risk of inadequate washout. Testing conducted by the EVA Physiology Laboratory at the NASA Johnson Space Center aimed to characterize a method for noninvasively measuring inspired oronasal CO2 under pressurized suited conditions in order to better inform requirements definition and verification techniques for future CO2 washout limits in space suits. Prior work conducted by the EPL examined several different wearable, respirator style, masks that could be used to sample air from the vicinity surround the nose and mouth of a suited test subject. Previously published studies utilized these masks, some being commercial products and some novel designs, to monitor CO2 under various exercise and flow conditions with mixed results for repeatability and/or consistency between subjects. Based on a meta-analysis of those studies it was decided to test a nasal cannula as it is a commercially available device that is placed directly in the flow path of the user as they breathe. A nasal cannula was used to sample air inhaled by the test subjects during both rest and exercise conditions. Eight subjects were tasked with walking on a treadmill or operating an arm ergometer to reach target metabolic rates of 1000, 2000, and 3000 BTU/hr. Suit pressure was maintained at 4.3 psid for all tests, with supply flow rates of 6, 4, and 2 actual cubic feet per minute depending on the test condition. Each test configuration was conducted twice with subjects breathing either through their nose only, or however they felt comfortable. By restricting breathing through a single orifice, we are able to more accurately define exactly what flow stream the sampled CO2 is taken from. Oronasal CO2 was monitored using real time infrared gas analyzers fed via sample tubes connected to the nasal cannula within the suit. Two additional sampling tubes were placed at the head and chin of the test subject, in an effort to capture CO2 concentrations across the entire flow stream of the Mark-III vent system (flow path is head to neck). Metabolic rate was calculated via the exhaust CO2 concentration and used to adjust subject workload on either the treadmill or arm ergometer until the target was reached. Forward work will aim to characterize the historically accepted minimum ppCO2 in suit during EVA by repeating this study in the Extravehicular Mobility Unit (EMU) space suit. This will help to define washout requirements for future suits, be they NASA (e.g. Z-2) or Commercial Crew designed. Additionally it is important to determine the functional consequences of CO2 exposure during EVA. Severe CO2 symptoms are a result of very high concentration, acute exposures. While long term, low concentration exposures have been shown to result in slight cognitive decline, symptoms resolve upon quickly returning to nominal concentrations and it remains unknown the impact that minor deficits in cognitive performance can have on EVA performance.

Norcross, J.↗

Overview of the Turbine Based Combined Cycle Discipline

The NASA Fundamental Aeronautics Hypersonics project is focused on technologies for combined cycle, airbreathing propulsions systems to enable reusable launch systems for access to space. Turbine Based Combined Cycle (TBCC) propulsion systems offer specific impulse (Isp) improvements over rocket-based propulsion systems in the subsonic takeoff and return mission segments and offer improved safety. The potential to realize more aircraft-like operations with expanded launch site capability and reduced system maintenance are additional benefits. The most critical TBCC enabling technologies as identified in the National Aeronautics Institute (NAI) study were: 1) mode transition from the low speed propulsion system to the high speed propulsion system, 2) high Mach turbine engine development, 3) transonic aero-propulsion performance, 4) low-Mach-number dual-mode scramjet operation, 5) innovative 3-D flowpath concepts and 6) innovative turbine based combined cycle integration. To address several of these key TBCC challenges, NASA s Hypersonics project (TBCC Discipline) initiated an experimental mode transition task that includes an analytic research endeavor to assess the state-of-the-art of propulsion system performance and design codes. This initiative includes inlet fluid and turbine performance codes and engineering-level algorithms. This effort has been focused on the Combined Cycle Engine Large-Scale Inlet Mode Transition Experiment (CCE LIMX) which is a fully integrated TBCC propulsion system with flow path sizing consistent with previous NASA and DoD proposed Hypersonic experimental flight test plans. This experiment is being tested in the NASA-GRC 10 x 10 Supersonic Wind Tunnel (SWT) Facility. The goal of this activity is to address key hypersonic combined-cycle-engine issues: (1) dual integrated inlet operability and performance issues unstart constraints, distortion constraints, bleed requirements, controls, and operability margins, (2) mode-transition constraints imposed by the turbine and the ramjet/scramjet flow paths (imposed variable geometry requirements), (3) turbine engine transients (and associated time scales) during transition, (4) high-altitude turbine engine re-light, and (5) the operating constraints of a Mach 3-7 combustor (specific to the TBCC). The model will be tested in several test phases to develop a unique TBCC database to assess and validate design and analysis tools and address operability, integration, and interaction issues for this class of advanced propulsion systems. The test article and all support equipment is complete and available at the facility. The test article installation and facility build-up in preparation for the inlet performance and operability characterization is near completion and testing is planned to commence in FY11.

Thomas, Scott R.↗

Advanced Single Phase Thermal Radiator for Moon-to-Mars Exploration

Pumped loop radiators are commonly used to reject large amounts of heat associated with crewed systems. The State-of-the-Art (SOA) for crewed systems is represented by the International Space Station (ISS) External Heat Rejection System (HRS) Thermal Radiators. The ISS HRS utilizes a manifold design with many parallel flow paths coupled to thin face-sheets and low viscosity ammonia as the working fluid, which may not be preferred due to toxicity concerns. Although contemporary coolant choices provide lower freezing points, the current SOA design may not be well positioned to provide both sufficient heat transfer and manageable pressure drop due to very different fluid thermo-physical properties, including higher viscosities. The planned development of an advanced single phase, pumped loop thermal radiator utilizing a serpentine flow path with high thermally conductive face-sheets is presented herein.

In-Space Active Thermal Control↗

Digital Valve for High Pressure High Flow Applications

To address the challenges, which are involved with the development of flow control valves that can meet the requirements of deep oil wells such as high pressure, high flow rate, limited power and limited space, the authors have conceived a novel design configuration [1]. This design consists of a digitalized flow control valve with multipath and multistage pressure reduction structures. Specifically, the valve is configured as a set of parallel flow paths from the inlet to the outlet. A choke valve controls the total flow rate by digitally opening different paths or different combination of the paths. Each path is controlled by a poppet cap valve basically operated in on-off states. The number of flow states is 2N where N is the number of flow paths. To avoid erosion from sand in the oil and high speed flow, the seal area of the poppet cap valve is located at a distance from the flow inlet away from the high speed flow and the speed is controlled to stay below a predefined erosion safe limit. The path is a multistage structure composed of a set of serial nozzles-expansion chambers that equally distribute the total pressure drop to each stage. The pressure drop of each stage and, therefore, the flow speed at the nozzles and expansion chambers is controlled by the number of stages. The paths have relatively small cross section and could be relatively long for large number of stages and still fit in the strict annular space limit of a typical downhole region of an oil well. The paper will present the design configuration, analysis and preliminary test results.

downhole↗