Two-stage nonlinear compression of high-power femtosecond laser pulses

Two-stage compression of laser pulses with a power of 250 TW is experimentally realised by broadening their spectrum during self-phase modulation in fused silica and subsequent dispersion compensation upon reflection from chirping mirrors. A five-fold decrease in the duration is demonstrated, from 75 to 15 fs, with a B-integral value of about 5 at each stage. It is possible to avoid small-scale self-focusing due to self-filtering of the laser beam during free propagation in vacuum. With optimal parameters of the dispersive mirror, the pulse can be compressed to a duration of less than 5 fs. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interference effects in the formation of the light bullet spectrum under axicon focusing

Specific features of the anti-Stokes band of the light bullet supercontinuum spectrum under filamentation of 1900-nm femtosecond pulses, focused by an axicon in fused silica and calcium fluoride, have been experimentally, numerically, and analytically investigated. It is found that the formation of two or more light bullets in a filament leads to modulation of spectral components’ intensity. The oscillation period of spectral components, defined as the wavelength interval between adjacent intensity minima, decreases with decreasing their wavelength. On a logarithmic scale, the relative change in the oscillation period in the spectrum is proportional to the spectral component wavelength and is independent of the pulse energy and the position of the light bullet formation region in the filament. It is established that the modulation in the spectrum is due to the interference of the broadband supercontinuum emitted by light bullets, and its period decreases with increasing interval between them. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

OH density, flux and loss probability measurements in a room temperature atmospheric pressure surface discharge by microscopic laser induced fluorescence

Many applications involving atmospheric pressure plasma-substrate interactions are enabled by the large fluxes of short-lived reactive species such as OH radicals to the substrate, nonetheless, the accurate measurement of radical densities and fluxes at substrates at atmospheric pressure has received little attention to date, particularly for surface ionization waves. We report the measurement of the OH density distribution in a surface discharge on a fused silica (quartz) substrate generated by an impinging atmospheric pressure plasma jet in dry and humid helium. The OH density is measured by microscopic laser induced fluorescence with a spatial resolution of 10 µm in the direction perpendicular to the quartz substrate. The measured OH diffusive flux varied for the investigated experimental conditions by almost three orders of magnitude and had a maximum value of 1.7 × 10 15 cm -2 s -1 . The corresponding surface loss probability of OH on the quartz surface was determined to be ~0.01. The high spatial resolution was required to accurately resolve the near surface gradient of OH radicals.

plasma-surface interactions↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

Upgrades of the ATLAS zero degree calorimeter system for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1, were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with H_2-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; a new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new “Reaction Plane Detectors” (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run 3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run 3.

43 PARTICLE ACCELERATORS↗

Sound velocities in shock-compressed soda lime glass: Melting and liquid-state response

Longitudinal sound velocities (and elastic moduli) were determined in soda lime glass (SLG) at peak shock stresses ranging between 40 and 90 GPa. Laser interferometry was used to obtain particle velocity histories and sound velocities by impacting SLG samples on lithium fluoride (LiF) optical windows. In all experiments, the SLG response consists of a sharp jump to a constant state followed by a release wave. The measured longitudinal sound velocities and moduli showed a marked decrease between 52 and 58 GPa, providing experimental evidence for the transformation from an amorphous solid to a liquid in shock-compressed SLG. Furthermore, the stress threshold (~55 GPa) for melting in SLG is considerably lower than the threshold reported in shock-compressed fused silica (~72 GPa), showing the effect of network-modifying cations on the onset of melting. The relative values of sound velocities, shock velocities, and the Hugoniot slopes—between 58 and 90 GPa—are fully consistent with the thermodynamic response of a shock-compressed liquid. Using the experimental results, the Grüneisen parameter (Γ) values were determined for liquid SLG to 90 GPa and then used to provide the Mie-Grüneisen equation of state for liquid SLG.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Glass 3D Printing of Microfluidic Pressure Sensor Interrogated by Fiber-Optic Refractometry

This letter reports a novel fused silica microfluidic device with pressure sensing capability that is fabricated by integrated additive and subtractive manufacturing (IASM) method. The sensor consists of a capillary and a 3D printed glass reservoir, where the reservoir volume change under pressure manifests liquid level deviation inside the capillary, thus realizing the conversion between small pressure change into large liquid level variation. Thanks to the design flexibility of this unique IASM method, the proposed microfluidic device is fabricated with liquid-in-glass thermometer configuration, where the reservoir is sealed following a novel 3D printing assisted glass bonding process. And liquid level is interrogated by a fiber-optic sensor based on multimode interference (MMI) effect. This proposed microfluidic device is attractive for chemical and biomedical sensing because it is flexible in design, and maintains good chemical and mechanical stability, and adjustable sensitivity and range.

42 ENGINEERING↗

Laser-damage performance of gallium-alloy liquid metal mirrors

We explore the characteristics and laser-damage behavior of gallium-based liquid metal alloy mirrors under exposure to ns laser pulses. One of the key advantages of using liquid metal mirrors is the self-healing potential following perturbations arising from exposure to high-power laser pulses. In this work, key performance metrics, such as reflectivity and the laser-damage initiation mechanism and initiation threshold, were investigated using fused-silica cells filled with three different liquid metal Ga alloys. The results suggest that irreversible modification (damage) under 355-nm, 6-ns pulses are associated with the formation of gallium oxide, taking place at a fluence significantly higher than that for damage initiation in conventional metal mirrors. This behavior is believed to arise from the different damage initiation mechanism in liquid metal mirrors requiring increased laser absorbed energy for an irreversible modification of the material surface to occur. As a result, this exploratory work is the first of its kind and highlights some favorable performance characteristics of gallium-alloy metal mirrors.

47 OTHER INSTRUMENTATION↗

Exploring self-healing liquid metal mirrors for high-power laser applications

Here we explore the laser-damage behavior of gallium alloy-based liquid metal mirrors for their potential to provide higher damage-threshold performance. One of the key advantages of using liquid metal mirrors is the self-healing potential following perturbations arising from exposure to high-power laser pulses. In this work, key performance metrics, such as reflectivity and the laser-damage initiation mechanism and initiation threshold, were investigated using fused-silica cells filled with three different Ga liquid metal alloys. The results suggest that irreversible modification (damage) under 355- nm, 6-ns pulses are associated with the formation of gallium oxide, taking place at a fluence significantly higher than that for damage initiation in conventional metal mirrors. This exploratory work is the first of its kind and highlights the strong performance of gallium alloy metal mirrors.

47 OTHER INSTRUMENTATION↗

Effect of workpiece curvature on the tool influence function during hemispherical sub-aperture tool glass polishing

The influence of workpiece curvature on the tool influence function spot during polishing of fused silica glass with cerium oxide slurry, while using a rotating hemispherical pad-foam tool for a wide variety of process conditions (tool displacement, inclination angle, and rotation rate), has been investigated. (Workpiece curvature ranged from 500 mm radius concave to 43 mm radius convex.) The TIF spot decreases in diameter and increases in the peak removal rate on more convex workpieces. In contrast, the TIF spot increases both in diameter and peak removal rate on more concave workpieces. For the range of workpiece curvatures investigated, both the spot size and the peak removal rate changed significantly, as much as 2 times. An elastic sphere–sphere contact mechanics model, which utilizes both a modified displacement (that leads to a change in the applied load) as well as a mismatch factor (that influences the pressure distribution shape), has been developed. Furthermore, the model was validated using both offline load-displacement measurements and finite-element analysis simulations. The model quantitatively describes the measured change in the relative contact diameter and relative pressure distribution, as well as semiquantitively describes the change in the relative volumetric removal rate on a large variety of TIF spots. The change in the volumetric removal rate for convex workpieces is a result of the balance between a decreasing spot size (reducing removal) and an increasing peak pressure (increasing removal), which usually results in relatively small changes in volumetric removal. In the case of concave workpieces, the volumetric removal rate change is also governed by a similar balance, but the spot size increase contribution dominates, resulting in a significant increase in volumetric removal rate. Understanding these trends can enable methods to add greater determinism during the fabrication of freeform optics by adjusting polishing parameters (such as dwell time) while the tool translates along a workpiece surface with different local curvatures.

47 OTHER INSTRUMENTATION↗

Understanding and reducing mid-spatial frequency ripples during hemispherical sub-aperture tool glass polishing

We report during sub-aperture tool polishing of glass optics, mid-spatial surface ripples are generated because of material removal non-uniformities during tool linear translation (resulting in feed ripples) and tool pathway step overlaps (resulting in pitch ripples). A variety of tool influence function (TIF) spots, trenches, and patches were created to understand and minimize such ripples on fused silica workpieces after polishing with cerium oxide slurry using a rotating hemispherical pad-foam tool. The feed ripple amplitude can be decreased by reducing the non-uniformities in the pad texture and/or by minimizing a derived feed ripple metric ($r_f = V^{0.5}_{max}V_f/R_t$) via adjustments in processing parameters. Pitch ripples can be minimized by reducing relative step distance to spot radius ratio ($x_s/a_t$) and by achieving a flat bottom trench shape cross section or by reducing the material removal per pass. Using the combined methods, an overall ripple error of ~1.2nm rms has been achieved.

47 OTHER INSTRUMENTATION↗

Understanding the tool influence function during sub-aperture belt-on-wheel glass polishing

The tool influence function (TIF) during sub-aperture belt-on-wheel polishing has been evaluated as a function of various process conditions (belt use/wear, dwell time, displacement, belt velocity, and wheel modulus and diameter) on fused silica glass workpieces using C e O 2 polishing media. TIF spots are circular or elliptical in shape with a largely flat bottom character. Furthermore, the volumetric removal rate varies significantly with belt use (or wear), stabilizing after ~<!-- ~ --> 15 m i n of use. A modified Preston model, where the pressure dependence is adjusted using a different scaling of the wheel modulus ( E w 0.5 ), largely predicts the volumetric removal rate over the range of process conditions evaluated. The relatively high volumetric removal rate of 30 -<!-- - --> 60 m m 3 / h using a fixed C e O 2 -in-resin-host belt offers a rapid, and hence, more economical, initial polish of aspheric and freeform optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Milliradian precision ultrafast pulse control for spectral phase metrology

A pulse-shaper-based method for spectral phase measurement and compression with milliradian precision is proposed and tested experimentally. Measurements of chirp and third-order dispersion are performed and compared to theoretical predictions. The single-digit milliradian accuracy is benchmarked by a group velocity dispersion measurement of fused silica.

Stamm, Jacob↗

Tamper performance for confined laser drive applications

The shock imparted by a laser beam striking a metal surface can be increased by the presence of an optically transparent tamper plate bonded to the surface. We explore the shock produced in an aluminum slab, for a selection of tamper materials and drive conditions. The experiments are conducted with a single-pulse laser of maximum fluence up to 100 J/cm 2 . The pressure and impulse are measured by photon doppler velocimetry, while plasma imaging is used to provide evidence of nonlinear tamper absorption. We demonstrate a pressure enhancement of 50x using simple commercially available optics. We compare results from hard dielectric glasses such as fused silica to soft plastics such as teflon tape. We discuss the mechanism of pressure saturation observed at high pulse fluence, along with some implications regarding applications. Below saturation, overall dependencies on pulse intensity and material parameters such as mechanical impedances are shown to correlate with a model by Fabbro et al .

36 MATERIALS SCIENCE↗

Non-destructive identification of absorptive damage sites by photoluminescence brightening

We present a non-destructive photoluminescence (PL) imaging strategy for probing damage growth behavior in fused silica under laser irradiation. Transient wide-field PL image measurements were conducted at varying excitation intensities to investigate the dynamics of radiative defect generation and annihilation in laser-induced damage sites. Our results reveal that, while low excitation intensities predominantly induce PL quenching due to defect annihilation, high-intensity excitation (>0.3 GW/cm 2 at 532 nm) triggers pronounced PL brightening (PLB), indicative of radiative defect generation. Image analysis demonstrates that PLB events are strongly correlated with subsequent damage growth (10 J/cm 2 at 351 nm), whereas overall PL intensity is not. No optically detectable morphological changes were observed during PLB, confirming the non-destructive nature of the technique. We propose that PLB arises from defect-assisted absorption of multiple photons at pre-existing absorptive centers, which enhances local absorptivity and initiates further defect formation. These findings establish PLB monitoring as a sensitive diagnostic tool for identifying damage sites with elevated absorptivity, enabling targeted maintenance and improved laser damage management in optical materials.

Materials science↗

Dual-mode fiber-optic refractive-index gas thermometry with primary anchoring and continuous temperature tracking

Extending fiber-optic refractive-index gas thermometry beyond primary-only operation, we report a dual-mode argon-filled Fabry-Perot thermometer in which the same cavity first establishes a primary temperature anchor and then performs continuous secondary-mode tracking. The primary anchor is obtained from two-pressure fringe shifts using a virial-coefficient refractivity model. During secondary operation, pressure cycling is stopped, and temperature is recovered from the monitored fringe wavelength and gas pressure using a model that includes argon refractivity, pressure-induced cavity strain, and fused-silica thermal expansion. From 310 to 1013 K, secondary-mode temperatures agreed with a reference thermocouple with 0.21 K RMSE and 0.47 K maximum error; 45-min natural furnace cooldowns were also tracked from nearby anchors with close agreement. The dual-mode method retains the empirical-calibration-free primary measurement as an in-situ reference while enabling simpler continuous tracking between anchors, addressing a practical limitation of primary-only fiberoptic refractive-index gas thermometry for hightemperature applications.

Syed, Musaddeque [Michigan State University, East ↗

Enhancing the performance of solvent-borne poly(ethyl methacrylate) coatings for high-power laser applications via low-temperature drying

Organic polymers are a versatile class of materials employed in a broad range of optical coating applications. However, their use as coatings in high-power laser applications, particularly in the UV spectral region, has been limited in scope due to their relatively low laser-induced damage thresholds (LIDTs), which decrease further with exposure to multiple pulses. This study explores the effect of post-deposition drying temperature and residual solvent on the LIDT of solvent-borne polymer coatings. In this work, poly(ethyl methacrylate) (PEMA) coatings were deposited by first spin coating solutions of PEMA (dissolved in 2,2,2-trichloroethanol (TCE)) onto fused silica substrates, then baking at temperatures of either 130°C (soft-bake) or 180°C (hard-bake). Analysis of the two coatings revealed that the soft-bake coating retained a significant amount of TCE within the polymer matrix, which functioned to plasticize the coating and reduce internal stress. The laser-induced damage resistance of the two coatings was evaluated using 351-nm, 1-ns laser pulses. The testing protocols included single-pulse (1-on-1), 1-pulse ramp (R-on-1), and a 1000-pulse ramp (1000R-on-1) test. The results showed that the plasticized, soft-bake coating exhibits a significantly increased LIDT, especially for multipulse irradiation conditions.

36 MATERIALS SCIENCE↗

Estimating Beam-Target Heating

At Los Alamos National Laboratory, two high-current linear induction accelerators (LIAs) are used to produce bremsstrahlung source spots for flash radiography of high-explosive driven hydrodynamic experiments at the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility. Measurements of the electron-beam current density profile are valuable for understanding the beam dynamics in order to improve the quality of the radiography source spot. A technique commonly used at DARHT is to image the profile in Cerenkov or Optical Transition Radiation (OTR) light created by the beam striking a thin target inserted into the beam line. Target materials include aluminized dielectrics and titanium foils for OTR, and fused silica wafers for Cerenkov radiation. A practical complication with this technique is heating of the target by the electron beam. If the beam density is too great, the target can be destroyed. Moreover, even if the beam density is kept low enough to be nondestructive, the beam can heat the target to a high enough temperature to desorb gas from the surface. In that case, direct impact ionization of the gas by beam electrons can partially neutralize the beam, causing it to over-focus, thereby spoiling the data, if not destroying the target. The purpose of this note is to review some of the fundamental physics of electron beam heating in order to provide some elementary guidance for design of these imaging experiments to avoid overheating the target. Some specific examples for materials that we often use for imaging targets and beam-target experiments are provided.

43 PARTICLE ACCELERATORS↗