Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design, Construction, and Initial Test of High Spatial Resolution Thermometry Arrays for Detection of Surface Temperature Profiles on SRF Cavities in Super Fluid Helium

We designed and built two high resolution (0.6-0.55mm special resolution [1.1-1.2mm separation]) thermometry arrays prototypes out of the Allen Bradley 90-120 ohm 1/8 watt resistor to measure surface temperature profiles on SRF cavities. One array was designed to be physically flexible and conform to any location on a SRF cavity; the other was modeled after the common G-10/stycast 2850 thermometer and designed to fit on the equator of an ILC (Tesla 1.3GHz) SRF cavity. We will discuss the advantages and disadvantages of each array and their construction. In addition we will present a case study of the arrays performance on a real SRF cavity TB9NR001. TB9NR001 presented a unique opportunity to test the performance of each array as it contained a dual (4mm separation) cat eye defect which conventional methods such as OST (Oscillating Superleak second-sound Transducers) and full coverage thermometry mapping were unable to distinguish between. We will discuss the new arrays ability to distinguish between the two defects and their preheating performance.

43 PARTICLE ACCELERATORS↗

Mapping ephemeral stream networks in desert environments using very-high-spatial-resolution multispectral remote sensing

In this paper, understanding the spatial patterns of ephemeral streams is crucial for understanding how hydrologic processes influence the abundance and distribution of wildlife habitats in desert regions. Available methods for mapping ephemeral streams at the watershed scale typically underestimate the size of channel networks. Although remote sensing is an effective means of collecting data and obtaining information on large, inaccessible areas, conventional techniques for extracting channel features are not sufficient in regions that have small topographic gradients and subtle target-background spectral contrast. By using very high resolution multispectral imagery, we developed a new algorithm that applies landscape information to map ephemeral channels in desert regions of the Southwestern United States where utility-scale solar energy development is occurring. Knowledge about landscape features and structures was integrated into the algorithm using a series of spectral transformation and spatial statistical operations to integrate information about landscape features and structures. The algorithm extracted ephemeral stream channels at a local scale, with the result that approximately 900% more ephemeral streams was identified than what were identified by using the U.S. Geological Survey’s National Hydrography Dataset. The accuracy of the algorithm in detecting channel areas was as high as 92%, and its accuracy in delineating channel center lines was 91% when compared to a subset of channel networks that were digitized by using the very high resolution imagery. Although the algorithm captured stream channels in desert landscapes across various channel sizes and forms, it often underestimated stream headwaters and channels obscured by bright soils and sparse vegetation. While further improvement is warranted, the algorithm provides an effective means of obtaining detailed information about ephemeral streams, and it could make a significant contribution toward improving the hydrological modelling of desert environments.

47 OTHER INSTRUMENTATION↗

High spatial resolution and contrast radiography of hydrodynamic instabilities at the National Ignition Facility

In this work, we are developing techniques for studying the Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high-energy-densities at the National Ignition Facility (NIF). In particular, through the improvement of experimental imaging quality, we are progressing toward the study of the turbulent regime of the mixing regions in capsule implosion experiments for inertial confinement fusion, which requires few micrometers resolution. Using 60 NIF beams, a solid shock tube is driven launching a shock wave that crosses the interface between a dense and a light material pre-machined in the target to obtain sinusoidal ripples, which results in RM and RT instabilities that are imaged using the NIF Crystal Backlighter Imager. High-quality images were obtained with a mean resolution of 7 μm and improved contrast. While the obtained resolution does not allow the observation of the smallest scale of the “turbulent” energy spectrum, the generated image encompasses 63% of the total flow energy, a 50% improvement over previous studies, which is observed for the first time a roll-up feature in a high energy density-type RT experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Nonlinear Optical Polarimetry with High Spatial Resolution

Nonlinear optical microscopy such as in the optical second-harmonic generation (SHG) modality has become a popular tool today for probing materials in the physical and biological sciences. While imaging and spectroscopy are widely used in the microscopy mode, nonlinear polarimetry, which can shed light on materials’ symmetry and microstructure, is relatively underdeveloped. This is partly because quantitative analytical modeling of the optical SHG response for anisotropic crystals and films largely assumes low-numerical aperture (NA) focusing of light, where the plane-wave approximation is sufficient. Tight focusing provides unique benefits in revealing out-of-plane polarization responses, which cannot be detected by near-plane-wave illumination at normal incidence. Here, we outline a method for quantitatively analyzing SHG polarimetry measurements obtained under high-NA focusing within a microscope geometry. Experiments and simulations of a variety of standard samples, from single crystals to thin films, are in good agreement, including measured and simulated spatial SHG maps of ferroelectric domains. A solution to the inverse problem is demonstrated, where the spatial distribution of an SHG tensor with unknown tensor coefficient magnitudes is determined by experimentally measured polarimetry. The ability to extract the out-of-plane component of the nonlinear polarization in normal incidence is demonstrated, which can be valuable for high-resolution polarimetry of 2D materials, thin films, heterostructures, and uniaxial crystals with a strong out-of-plane response.

36 MATERIALS SCIENCE↗

Aleurone Cell Walls of Wheat Grain: High Spatial Resolution Investigation Using Synchrotron Infrared Microspectroscopy

Infrared microspectroscopy and immunolabeling techniques were employed in order to obtain deeper insight into the biochemical nature of aleurone cell walls of wheat grain. The use of a synchrotron source, thanks to its intrinsic brightness, has provided unprecedented information at the level of a few micrometers and has allowed the discrimination of various polysaccharides in cell walls. The high spectral quality obtained in the small analyzed domain has been beneficial in estimating the relative proportions of {Beta}-glucan and arabinoxylan, through the use of principal component analysis (PCA). The highest amount of {Beta}-glucan is found in periclinal cell walls close to the starchy endosperm. The junction regions between aleurone cells are enriched in arabinoxylan. At the early stage of wheat grain development (271 degrees D), the chemical composition along the cell walls is more heterogeneous than at the mature stage. Both synchrotron infrared microspectroscopy and immunolabeling experiments made it possible to reveal the spatial heterogeneity of the various chemical compositions of aleurone cell walls.

43 PARTICLE ACCELERATORS↗

Fluorescence intensity correlation imaging with high spatial resolution and elemental contrast using intense x-ray pulses

We theoretically investigate the fluorescence intensity correlation (FIC) of Ar clusters and Mo-doped iron oxide nanoparticles subjected to intense, femtosecond, and sub-femtosecond x-ray free-electron laser pulses for high-resolution and elemental contrast imaging. We present the FIC of Kα and Kαh emission in Ar clusters and discuss the impact of sample damage on retrieving high-resolution structural information and compare the obtained structural information with those from the coherent diffractive imaging (CDI) approach. We found that, while sub-femtosecond pulses will substantially benefit the CDI approach, few-femtosecond pulses may be sufficient for achieving high-resolution information with the FIC. Furthermore, we show that the fluorescence intensity correlation computed from the fluorescence of the Mo atoms in Mo-doped iron oxide nanoparticles can be used to image dopant distributions in the nonresonant regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Facile and high spatial resolution ratio-metric luminescence thermal mapping in microfluidics by near infrared excited upconversion nanoparticles

A local area temperature monitor is important for precise control of chemical and biological processes in microfluidics. In this work, we developed a facile method to realize micron spatial resolution of temperature mapping in a microfluidic channel quickly and cost effectively. Based on the temperature dependent fluorescence emission of NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+} upconversion nanoparticles (UCNPs) under near-infrared irradiation, ratio-metric imaging of UCNPs doped polydimethylsiloxane can map detailed temperature distribution in the channel. Unlike some reported strategies that utilize temperature sensitive organic dye (such as Rhodamine) to achieve thermal sensing, our method is highly chemically inert and physically stable without any performance degradation in long term operation. Moreover, this method can be easily scaled up or down, since the spatial and temperature resolution is determined by an optical imaging system. Our method supplied a simple and efficient solution for temperature mapping on a heterogeneous surface where usage of an infrared thermal camera was limited.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-FG-204-09: High Spatial Resolution and Artifact-Free CT Bone Imaging at Off-Centered Positions: An Application of Model-Based Iterative Reconstruction

Purpose: Although the anatomy of interest should be positioned as close as possible to the isocenter of CT scanners, off-centering may be inevitable during certain exams in clinical practice such as lumbar spine and elbow imaging. Off-centering degrades image sharpness, generates streak artifacts, and sometimes creates blooming artifacts due to truncation. The purpose of this work was to investigate whether the use of model-based image reconstruction (MBIR) can alleviate the negative impacts of off-centering to achieve high quality CT bone imaging. Methods: Both an anthropomorphic phantom and an ex vivo swine elbow sample were scanned at centered and off-centered positions using clinical CT bone scan protocols. The magnitude of off-centering was determined from localizer radiographs. Both FBP and MBIR reconstructions were performed. For FBP, both standard and Bone Plus kernels commonly used in bone imaging were used. Objective assessment of image sharpness, noise standard deviation, and noise nonuniformity were performed. Additionally, we retrospectively analyzed human subject data acquired under off-centered conditions as a validation study. Results: In FBP images of the phantom, off-centering by 10 cm led to a 14% increase in noise (p<1e-3) and a 68% increase in noise nonuniformity (p<0.02). A visible drop in bone sharpness was observed. In contrast, no significant difference in the noise magnitude or the noise nonuniformity between the centered and off-centered MBIR images was found. The image sharpness of off-centered MBIR images outperformed that of FBP images reconstructed with the Bone Plus kernel. In images of the swine elbow off-centered by 20 cm, not only was the noise and spatial resolution performance improved by MBIR, truncation artifacts were also elliminated. The human subject study generated similar results, in which the visibility of the off-centered lumbar spine was significantly improved. Conclusion: High quality CT bone imaging at off-centered positions can be achieved using MBIR. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX. A. Budde, J. Hsieh: Employee, GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Inverse modeling of pan-Arctic methane emissions at high spatial resolution: what can we learn from assimilating satellite retrievals and using different process-based wetland and lake biogeochemical models?

Understanding methane emissions from the Arctic, a fast-warming carbon reservoir, is important for projecting future changes in the global methane cycle. Here we optimized methane emissions from north of 60° N (pan-Arctic) regions using a nested-grid high-resolution inverse model that assimilates both high-precision surface measurements and column-average SCanning Imaging Absorption spectroMeter for Atmospheric CHartogrphY (SCIAMACHY) satellite retrievals of methane mole fraction. For the first time, methane emissions from lakes were integrated into an atmospheric transport and inversion estimate, together with prior wetland emissions estimated with six biogeochemical models. In our estimates, in 2005, global methane emissions were in the range of 496.4–511.5 Tg yr –1 , and pan-Arctic methane emissions were in the range of 11.9–28.5 Tg yr –1 . Methane emissions from pan-Arctic wetlands and lakes were 5.5–14.2 and 2.4–14.2 Tg yr –1 , respectively. Methane emissions from Siberian wetlands and lakes are the largest and also have the largest uncertainty. Our results indicate that the uncertainty introduced by different wetland models could be much larger than the uncertainty of each inversion. We also show that assimilating satellite retrievals can reduce the uncertainty of the nested-grid inversions. The significance of lake emissions cannot be identified across the pan-Arctic by high-resolution inversions, but it is possible to identify high lake emissions from some specific regions. In contrast to global inversions, high-resolution nested-grid inversions perform better in estimating near-surface methane concentrations.

58 GEOSCIENCES↗

Estimating global and North American methane emissions with high spatial resolution using GOSAT satellite data

We use 2009–2011 space-borne methane observations from the Greenhouse Gases Observing SATellite (GOSAT) to estimate global and North American methane emissions with 4° × 5° and up to 50 km × 50 km spatial resolution, respectively. GEOS-Chem and GOSAT data are first evaluated with atmospheric methane observations from surface and tower networks (NOAA/ESRL, TCCON) and aircraft (NOAA/ESRL, HIPPO), using the GEOS-Chem chemical transport model as a platform to facilitate comparison of GOSAT with in situ data. This identifies a high-latitude bias between the GOSAT data and GEOS-Chem that we correct via quadratic regression. Our global adjoint-based inversion yields a total methane source of 539 Tg a &minus;1 with some important regional corrections to the EDGARv4.2 inventory used as a prior. Results serve as dynamic boundary conditions for an analytical inversion of North American methane emissions using radial basis functions to achieve high resolution of large sources and provide error characterization. We infer a US anthropogenic methane source of 40.2–42.7 Tg a &minus;1 , as compared to 24.9–27.0 Tg a &minus;1 in the EDGAR and EPA bottom-up inventories, and 30.0–44.5 Tg a &minus;1 in recent inverse studies. Our estimate is supported by independent surface and aircraft data and by previous inverse studies for California. We find that the emissions are highest in the southern–central US, the Central Valley of California, and Florida wetlands; large isolated point sources such as the US Four Corners also contribute. Using prior information on source locations, we attribute 29–44 % of US anthropogenic methane emissions to livestock, 22–31 % to oil/gas, 20 % to landfills/wastewater, and 11–15 % to coal. Wetlands contribute an additional 9.0–10.1 Tg a &minus;1 .

54 ENVIRONMENTAL SCIENCES↗

Mass spectrometric imaging as a high-spatial resolution tool for functional genomics: Tissue-specific gene expression of TT7 inferred from heterogeneous distribution of metabolites in Arabidopsis flowers

Laser desorption/ionization (LDI) mass spectrometry imaging (MSI) was used to acquire chemical images of flavonoid metabolites on the surface of wild-type and mutant (tt7) Arabidopsis thaliana flowers. Flavonoids were localized to the petals and carpels of flowers, with tissue heterogeneity in the petals. Specifically, kaempferol and/or its glycosides were abundant in the distal region of petals and quercetin and its downstream flavonoids were highly enriched in the more proximal region of petals. As a result of a mutation in the TT7 gene which blocks the conversion of dihydrokaempferol to dihydroquercetin, the downstream metabolites, quercetin, isohamnetin, and their glycosides, were not observed in the mutant flowers. Instead, the metabolites in an alternative pathway, kaempferol and/or its glycosides, were as highly abundant on the proximal region of the petals as in the distal region. In addition, the combined flavonoid amounts on the proximal region of petals in the wild-type are almost equivalent to the amounts of kaempferol and/or its glycosides in the mutant. This strongly suggests that the expression of the TT7 gene is localized on the proximal part of the petal while the other genes in the upper stream pathway are evenly expressed throughout the petal. Most importantly, this work demonstrates MSI of metabolites can be utilized for the localization of gene expression.

47 OTHER INSTRUMENTATION↗

Variable location channels to improve efficiency and precision for direct ∇ T e measurements and high spatial resolution T e -profile measurements using electron cyclotron emission

Electron cyclotron emission (ECE) diagnostics that use variable location channels based on yttrium iron garnet (YIG) bandpass filters improve the precision and the efficiency of measurements of electron temperature (T e ) profiles and fluctuations (δT e ). These variable frequency filters were substituted for fixed frequency filters in the intermediate frequency section to achieve the required higher resolution over a target radial range, just before the experiment. In this paper, we present the proof-of-principle for high temporal resolution measurement of the electron temperature gradient, via real-time slewing of a YIG filter for relocation of an ECE channel during a long pulse. The key component is the application of YIG tunable filters with their narrow bandwidth and capability for a high slew rate of their center frequency. This application permits fast relocation of the ECE channels for direct measurement of the gradient and close spacing of channels to investigate the magnetic island’s dynamic behavior.

47 OTHER INSTRUMENTATION↗

Predicting vehicular emissions in high spatial resolution using pervasively measured transportation data and microscopic emissions model

Air pollution related to traffic emissions pose an especially significant problem in cities; this is due to its adverse impact on human health and well-being. Previous studies which have aimed to quantify emissions from the transportation sector have been limited by either simulated or coarsely resolved traffic volume data. Emissions inventories form the basis of urban pollution models, therefore in this study, Global Positioning System (GPS) trajectory data from a taxi fleet of over 15,000 vehicles were analyzed with the aim of predicting air pollution emissions for Singapore. This novel approach enabled the quantification of instantaneous drive cycle parameters in high spatio-temporal resolution, which provided the basis for a microscopic emissions model. Carbon dioxide (CO2), nitrogen oxides (NOx), volatile organic compounds (VOCs) and particulate matter (PM) emissions were thus estimated. Highly localized areas of elevated emissions levels were identified, with a spatio-temporal precision not possible with previously used methods for estimating emissions. Relatively higher emissions areas were mainly concentrated in a few districts that were the Singapore Downtown Core area, to the north of the central urban region and to the east of it. Daily emissions quantified for the total motor vehicle population of Singapore were found to be comparable to another emissions dataset Results demonstrated that high resolution spatio-temporal vehicle traces detected using GPS in large taxi fleets could be used to infer highly localized areas of elevated acceleration and air pollution emissions in cities, and may become a complement to traditional emission estimates, especially in emerging cities and countries where reliable fine-grained urban air quality data is not easily available. This is the first study of its kind to investigate measured microscopic vehicle movement in tandem with microscopic emissions modeling for a substantial study domain.

54 ENVIRONMENTAL SCIENCES↗

WORKSHOP ON URBAN SCALE PROCESSES AND THEIR REPRESENTATION IN HIGH SPATIAL RESOLUTION EARTH SYSTEM MODELS

It is essential that numerical models used to study physics, chemistry, and biology affecting the Earth system at regional and global scales represent the effects of urban areas on climate and the effects of changing the climate on urban areas. At the same time, it is essential to develop state of the art, simple and accurate urban models to better understand the relevant processes and also toaddress issues related to urban security against the spectra of chemical, biological and radiological (CBR) hazards. Towards bringing these communities together, a 2.5-day international workshop was held at Argonne National Laboratory (ANL) in the Chicago area on May 22-24, 2019. This workshop brought together national and international experts to develop a roadmap for a better understanding of the issues associated with urban areas and at enhancing the capabilities of regional and global Earth System models (ESMs) in representing the atmospheric dynamics and chemistry, unique aspects of the biosphere and land use, and human dimensions of the urban environment. This workshop was especially important to those developing very high-resolution versions of regional and global models. The workshop also discussed existing datasets, including in situ and satellite observations, and the emerging smart city sensing technologies and their possible use in model development (e.g., the NSF-funded Array of Things network currently operating in Chicago and expanding to other cities).

54 ENVIRONMENTAL SCIENCES↗

A poly(dimethylsiloxane)-based device enabling time-lapse imaging with high spatial resolution

We have developed a regulator-free device that enables long-term incubation of mammalian cells for epi-fluorescence imaging, based on a concept that the size of sample to be gassed and heated is reduced to observation scale. A poly(dimethylsiloxane) block stamped on a coverslip works as a long-lasting supplier of CO{sub 2}-rich gas to adjust bicarbonate-containing medium in a tiny chamber at physiological pH, and an oil-immersion objective warms cells across the coverslip. A time-lapse imaging experiment using HeLa cells stably expressing fluorescent cell-cycle indicators showed that the cells in the chamber proliferated with normal cell-cycle period over 2 days.

60 APPLIED LIFE SCIENCES↗