76 records · Page 5

Interfacial engineering via laser ablation for high-performing PEM water electrolysis

A rationalized interfacial design strategy was applied to tailor the porous transport layer (PTL)-catalyst layer (CL) contact and the PTL bulk-phase architecture. Particularly, at the PTL-CL interface, our results reveal that laser ablated sintered titanium power-based PTLs improve electrolyzer performance at both the H2NEW Consortium baseline catalyst loading of 0.4 mgIr cm -2 as well as at the ultra-low catalyst loading of 0.055 mgIr cm -2 . Under ultra-low catalyst loadings, the laser ablated PTL demonstrates maximum reduction of 230 mV compared to the commercial PTL at 4 A cm -2 , and reduces by 68 mV at 3.2 A cm -2 under H2NEW baseline loading. Laser ablation alters the titanium phase at the interface, so it forms more uniform structure like a microporous layer or a backing layer, leading to an increase in the surface area in contact with the catalyst layer while preventing the membrane from deforming into the PTL. Moreover, we reveal that bulk-phase architecture modification of the PTL by ablating patterned pores at the flow field-PTL interface improves mass transport without sacrificing contact at the CL-PTL interface. Overall, laser ablation of the PTL is an effective method to customize interfacial design to enhance proton exchange membrane electrolyzer performance.

08 HYDROGEN↗

Advanced PGM-free Cathode Engineering for High Power Density and Durability

Polymer electrolyte fuel cells (PEFCs) are among the most promising technologies for future electric vehicles by using clean H2 with much-improved energy conversion efficiency, longer range, and rapid refueling. However, due to a large amount of platinum group metal (PGM) catalyst used in their electrodes, their prohibitively high cost hinders broad commercialization of PEFCs for transportation. Therefore, there is a critical need to develop low-cost, high-performance PGM-free cathode catalysts that have the potential to dramatically transform the economics of PEFC commercialization by reducing catalyst costs by one to two orders of magnitude. However, before PGM-free cathodes become viable, several technical challenges associated with PGM-free cathodes must be addressed, including insufficient activity and stability of the catalysts, as well as severe water flooding and large transport losses in the electrodes. Overcoming those barriers and ultimately meeting the challenging automotive PEFC performance targets was the focus of this comprehensive research and development effort on new PGM-free cathodes. To this end, we assembled a team including leading researchers from universities and industry with different but complementary expertise and capabilities. The project combined three novel and promising approaches: Advanced metal-organic framework (MOF)-derived M-N-C catalysts with a high activity and impressive durability, Novel PGM-free specific cathode architectures and fabrication strategies capable of addressing the substantial flooding and transport resistances in thicker cathodes by introducing engineered hydrophobicity through additives and support layers, and Advanced electrode ionomers with high proton conductivity for low ohmic losses across the electrode and more uniform catalyst utilization. The implementation of these new materials and electrode designs was supported by a suite of advanced experimental and simulation tools that allows us to identify performance and durability bottlenecks, devise solutions, and establish rational material design and synthesis targets. These methods include advanced electrochemical characterization, high-resolution imaging, and multi-scale modeling. In addition, the project team leveraged a broad cross-section of the ElectroCat consortium’s national laboratory facilities and expertise in advancing these materials and design strategies. Finally, the industry partners on the project facilitated the evaluation of scaled-up synthesis and manufacturing in the United States. Over its four-year period, the project made significant year-over-year advances in PGM-free cathode performance and viability. A combination of high activity and highly durable catalysts were developed through novel catalyst synthesis strategies, which met several performance and durability targets. More specifically, a catalyst prepared from MOFs and Fe2O3 nanoparticles with ammonium chloride and chemical vapor deposition treatments yielded a significant advancement in PGM-free cathode durability. Several novel strategies for fabricating cathodes were demonstrated, including those designed to reduce flooding and thickness of the cells for significantly increased volumetric power density. An optimized cathode with high conductivity ionomer and tuned ink processing for hydrophobicity yielded high fuel cell performance with new levels power density and maximum current. The scientific studies and modeling assessment also provided an outlook for future efforts, including a focus on catalysts with an increased density of the highly stable active sites developed in this project.

08 HYDROGEN↗

NREL 25-cm2 High-Pressure Low-Temperature Electrolysis Cell Hardware (Open Source)

This data resource describes an open-source cell hardware that enables low temperature electrolysis (LTE) testing at elevated pressures. Existing commercial options have several downsides when it comes to R&D testing. They are often not designed for repeated reassembly, may not be able to accommodate porous transport layers with different thicknesses, and do not give state-of-the-art performance. Therefore, this hardware was developed specifically with LTE R&D in mind and its design is being made available to the global LTE community. This work was planned and funded by the U.S. Department of Energy's H2NEW consortium (https://h2new.energy.gov/). The hardware design package (.zip file) details the drawings, auxiliary materials, and procedures required to fabricate, assemble, and operate the National Renewable Energy Laboratory's (NREL's) high-pressure low-temperature electrolysis cells. While the hardware itself—end plates, current collectors, flow fields, bolts and washers, tube fittings—is always the same, the assembly and operating procedures may change depending on the active materials being tested, especially for the membrane. Material-specific assembly and operating procedures will be posted to the H2NEW website as they are developed and validated. Disclaimer: The documents and drawings included in this download package describe a design for a low temperature electrolysis hardware that is intended to comply with leak testing according to ASME B31.1. Safe operation at ambient and elevated pressures is the sole responsibility of the end user, which should be evaluated on a case-by-case basis for each individual cell. Factors affecting the sealing capability may depend on, for example, machining quality, cell assembly components, operating conditions, and operating history. Operation at pressure should only be performed on qualified test stands by qualified operators. NREL/ALLIANCE FOR SUSTAINABLE ENERGY, LLC/DOE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND MAKES NO WARRANTY AS TO THE ACCURACY, COMPLETENESS, OR USEFULNESS OF ANY INFORMATION PROVIDED HEREIN. USE OF THIS PACKAGE IS AT THE USER’S OWN RISK.

08 HYDROGEN↗

Mitigation and Diagnosis of Pin-Hole Formation in Polymer Electrolyte Membrane Fuel Cells

In this work, we implement a calendering technique to flatten stray fibers within the gas diffusion media, thereby mitigating pin-hole formation in the hot-pressed MEAs. We have investigated the influence of calendering on the long-term durability for several types of gas diffusion electrodes (GDEs) using a combined chemical and mechanical accelerated stress test (AST). The calendered MEAs demonstrate an average AST lifetime improvement of 77% relative to the as-fabricated MEAs.

AMR↗