Miniature Joule Thomson (JT) CryoCoolers for Propellant Management

A proof-of-concept project is proposed here that would attempt to demonstrate how miniature cryocoolers can be used to chill the vacuum jacket line of a propellant transfer line and thus to achieve transfer line pre-chill, zero boil off and possible propellant densification. The project would be performed both at UCF and KSC, with all of the cryogenic testing taking place in the KSC cryogenic test bed. A LN2 line available in that KSC test facility would serve to simulate a LOX transfer line. Under this project, miniature and highly efficient cold heads would be designed. Two identical cold heads will be fabricated and then integrated with a JT-type cryogenic system (consisting of a common compressor and a common external heat exchanger). The two cold heads will be integrated into the vacuum jacket of a LN2 line in the KSC cryo lab, where the testing will take place.

Kapat, Jay↗

Current Pulses Momentarily Enhance Thermoelectric Cooling

The rates of cooling afforded by thermoelectric (Peltier) devices can be increased for short times by applying pulses of electric current greater than the currents that yield maximum steady-state cooling. It has been proposed to utilize such momentary enhancements of cooling in applications in which diode lasers and other semiconductor devices are required to operate for times of the order of milliseconds at temperatures too low to be easily obtainable in the steady state. In a typical contemplated application, a semiconductor device would be in contact with the final (coldest) somewhat taller stage of a multistage thermoelectric cooler. Steady current would be applied to the stages to produce steady cooling. Pulsed current would then be applied, enhancing the cooling of the top stage momentarily. The principles of operation are straightforward: In a thermoelectric device, the cooling occurs only at a junction at one end of the thermoelectric legs, at a rate proportional to the applied current. However, Joule heating occurs throughout the device at a rate proportional to the current squared. Hence, in the steady state, the steady temperature difference that the device can sustain increases with current only to the point beyond which the Joule heating dominates. If a pulse of current greater than the optimum current (the current for maximum steady cooling) is applied, then the junction becomes momentarily cooled below its lowest steady temperature until thermal conduction brings the resulting pulse of Joule heat to the junction and thereby heats the junction above its lowest steady temperature. A theoretical and experimental study of such transient thermoelectric cooling followed by transient Joule heating in response to current pulses has been performed. The figure presents results from one of the experiments. The study established the essential parameters that characterize the pulse cooling effect, including the minimum temperature achieved, the maximum temperature overshoot, the time to reach minimum temperature, the time while cooled, and the time between pulses. It was found that at large pulse amplitude, the amount of pulse supercooling is about a fourth of the maximum steady-state temperature difference. For the particular thermoelectric device used in one set of the experiments, the practical optimum pulse amplitude was found to be about 3 times the optimum steady-state current. In a further experiment, a pulse cooler was integrated into a small commercial thermoelectric threestage cooler and found to provide several degrees of additional cooling for a time long enough to operate a semiconductor laser in a gas sensor.

Snyder, G. Jeffrey↗

Temperature control in wafer-level testing of large multi-segment electromigration test structures

The paper describes two methods for maintaining a constant metallization temperature throughout a wafer-level isothermal electromigration test of large multisegment test structures where Joule-heating is high and chip to chuck thermal contact is poor. In the first method, an initial calibration of Joule heating versus metal temperature is carried out. During the isothermal electromigration test, the Joule heating is continuously monitored and the chuck temperature is adjusted based on the calibration results to maintain a constant metal temperature. In the second method, temperature sensors are fabricated on the chip and then the sensors are used to monitor the chip temperature directly. The chuck temperature is then adjusted as needed.

Zamani, Nasser↗

Energy dissipation in substorms

The energy dissipated by substorms manifested in several ways is discussed: the Joule dissipation in the ionosphere; the energization of the ring current by the injection of plasma sheet particles; auroral election and ion acceleration; plasmoid ejection; and plasma sheet ion heating during the recovery phase. For each of these energy dissipation mechanisms, a 'rule of thumb' formula is given, and a typical dissipation rate and total energy expenditure is estimated. The total energy dissipated as Joule heat (approximately) 2 x 10(exp 15) is found about twice the ring current injection term, and may be even larger if small scale effects are included. The energy expended in auroral electron precipitation, on the other hand, is smaller than the Joule heating by a factor of five. The energy expended in refilling and heating the plasma sheets is estimated to be approximately 5 x 10(exp 14)J, while the energy lost due to plasmoid ejection is between (approximately) (10 exp 13)(exp 14)J.

Weiss, Loretta A.↗

High-Latitude Thermosphere Neutral Density Response to Solar Wind Dynamic Pressure Enhancement

We examine the response of the thermosphere to the impact of solar wind dynamic pressure enhancements using observations and global magneto-hydrodynamics (MHD) simulations by the OpenGGCM model. Combining neutral density observations from the Challenging Minisatellite Payload (CHAMP) and the Gravity Recovery and Climate Experiment (GRACE) satellites with simultaneous Poynting flux measurements from the Defense Meteorological Satellite Program (DMSP) F16, we find that thermospheric density as well as downward Poynting flux intensified shortly after a sudden enhancement of the solar wind dynamic pressure. The intensification manifested mostly on the dayside high-latitude region with peak intensity in the vicinity of the noon and prenoon cusp. OpenGGCM modeling results show that the ionospheric Joule heating increased abruptly in response to the sudden enhancement of the dynamic pressure in the same region as the observed Poynting flux and neutral density enhancements. The modeling results show that the enhanced Joule heating coincides, both in time and location, with the appearance of a pair of high-latitude localized field-aligned currents (FACs) in the cusp region. The FACs intensified and extended azimuthally. Coincidental with the solar wind dynamic pressure enhancement, the y component of the interplanetary magnetic field (IMF) By became strongly positive and, in addition, had some large fluctuations. We explore the separate and combined effects of the dynamic pressure and IMF By perturbations, with specifically designed simulation experiments that isolate the effect of each solar wind parameter. We find that the dynamic pressure enhancement is the primary source for the Joule heating and neutral density enhancements, but the IMF By modulates the level of enhancement.

magneto-hydrodynamics↗

Apollo 13 Mission: Cryogenic Oxygen Tank 2 Anomaly Report

There were two investigative aspects associated with the loss of the cryogenic oxygen tank pressure during the Apollo 13 flight. First, what was the cause of the flight failure of cryogenic oxygen tank 2. Second, what possible contributing factors during the ground history of the tank could have led to the ultimate failure in flight. The first flight indication of a problem occurred when the quantity measurement in the tank went full scale about 9 hours before the incident. This condition in itself could not have contributed to ignition in the tank, since the energy in the circuit is restricted to about 7 milli-joules. Data from the electrical system provided the second indication of a problem when the fans in tank 2 were activated to reduce any stratification which might have been present in the supercritical oxygen in the tank. Several short-circuits were detected and have been isolated to the fan circuits of tank 2. The first short-circuit could have contained as much as 160 joules of energy, which is within the current-protection level of the fan circuits. Tests have shown that two orders of magnitude less energy than this is sufficient to ignite the polytetrafluoroethylene insulation on the fan circuits in the tank. Consequently, the evidence indicates that the insulation on the fan wiring was ignited by the energy in the short-circuit.

Source record↗

Magnetospheric processes and the behavior of the neutral atmosphere.

A review is given of the quiet time couplings which exist between the magnetosphere and the thermosphere. Joule heating arising from aurorae and the combination of Joule heating and ion drag arising from magnetospheric convection normally provide as much energy to the thermosphere as solar ultraviolet radiation. Ion drag is especially important for establishing wind systems in the thermosphere. Using the qualitative ideas of convective electric fields, a description of a possible model of the global wind system is given. It is pointed out that the existence of a convectively driven wind source at high latitudes consistent with magnetospheric convection leads to the possibility of a mean easterly wind, i.e., super-rotation.

Banks, P. M.↗

Low temperature mechanical properties, fractographic and metallographic evaluation of several alloy steels

The mechanical properties are presented of alloy steels, 4130, 4140, 4340, 6150, and 8740. Test specimens were manufactured from approximately 1.00 inch (2.54 cm) diameter bar stock which had been heat treated to two different hardness levels. The following mechanical tests were performed at temperatures of 80 F (+26.7 C), 0 F (-17.8 C), -100 F (-73 C), and -200 F (-129 C): (1) tensile test (Ultimate, yield, modulus, elongation, and reduction of area), (2) notched tensile test, (3) charpy V-notched impact test (impact energy), and (4) double shear strength test (ultimate and yield). The test data indicate excellent tensile strength, notched/unnotched tensile ratios, ductility, impact, and shear properties at all test temperatures, except at -200 F (-129 C) where the impact strength of the higher strength group of alloy steels, 4130 (Rc-37) and 4140 (Rc-44) decreased to approximately 9 ft. lbs. (12 joules) and 6 ft. lbs. (8 joules), respectively. Chemical, metallographic, and fractographic analyses were also performed to evaluate microstructure, microhardness and the effect of decrease in temperature on the ductile to brittle failure transition.

Montano, J. W.↗

A composite model for a class of electric-discharge shock tubes

A gasdynamic model is presented and analyzed for a class of shock tubes that utilize both Joule heating and electromagnetic forces to produce high-speed shock waves. The model consists of several stages of acceleration in which acceleration to sonic conditions is achieved principally through heating, and further acceleration of the supersonic flow is obtained principally through use of electromagnetic forces. The utility of the model results from the fact that it predicts a quasi-steady flow process, mathematical analysis is straightforward, and it is even possible to remove one or more component stages and still have the model related to a possible shock-tube flow. Initial experiments have been performed where the electrical discharge configuration and current level were such that Joule heating was the dominant form of energy addition present. These experiments indicate that the predictions of the model dealing with heat addition correspond quite closely to reality. The experimental data together with the theory show that heat addition to the flowing driver gas after diaphragm rupture (approach used in the model) is much more effective in producing high-speed shock waves than heating the gas in the driver before diaphragm rupture, as in the case of the arc-driven shock tube.

Elkins, R. T.↗

Preliminary design study of astronomical detector cooling system

The preliminary design of an astronomical detector cooling system for possible use in the NASA C-141 Airborne Infrared Observatory is presented. The system consists of the following elements: supercritical helium tank, Joule-Thomson supply gas conditioner, Joule-Thomson expander (JTX), optical cavity dewar, optical cavity temperature controller, adjustable J-T discharge gas pressure controller, and vacuum pump.

Norman, R. H.↗

Energetics of the magnetosphere

The approximate magnitudes of several power inputs and energies associated with the Earth's magnetosphere will be derived. They include: Solar wind power impinging on the dayside magnetopause approximately 1.4 10 to the 13th power watt; power input to cross tail current approximately 3 10 to the 11th power watt; energy of moderate magnetic storm approximately 2 10 to the 15th power joule; power related to the flow of j approximately 1 to 3 10 to the 11th power watt; average power deposited by the aurora approximately 2 10 to the 10th power watt. Stored magnetic energy: released in a substorm approximately 1.5 10 to the 14th power joule. Compared to the above, the rate at which energy is released locally in magnetospheric regions where magnetic merging occurs is probably small. Merging is essential, however, for the existence of open field lines, which provide the most likely explanation for some major energy inputs listed here. Merging is also required if part of the open flux of the tail lobes is converted into closed flux, as seems to happen during substorms. Again, most of the energy release becomes evident only beyond the merging region, though some particles may gain appreciable energy in that region itself, if the plasma sheet is completely squeezed out and the high latitude lobes interact directly.

Stern, D. P.↗

Prediction of residual tensile strength of transversely impacted composite laminates

The response to low velocity impact of graphite-epoxy T300/5208 composite laminates is discussed. Steel balls of 3/8 inch, 5/8 inch, and 1 inch diameter were the projectiles. Impact energy was limited to 1.2 joules. Impacted specimens were ultrasonically C scanned to determine the impact damaged region. The threshold value of impact energy for impact damage was found to be approximately 0.3 joules. A model was developed to predict the tensile residual strength of impact damaged specimens from fracture mechanics concepts. Impacted specimens were tested in tension to provide a fracture data base. The experimental results agreed well with the predictions from fracture mechanics. In this study, the maximum impact velocity used to simulate the low velocity transverse impact from common objects like tool drops was 10 m/s.

Lal, K. M.↗

Modeling of high-latitude currents in a substorm

The currents and electric fields in the area covered by the poleward set of field-aligned currents are computed by means of a quantitative model, in which the high-latitude band considered carries most of the poleward electrojet, and lies poleward of the region covering the inner magnetosphere and corresponding ionosphere. The Birkeland current and aurorally enhanced conductivity are assumed to be uniformly distributed across the band. The time-dependent conductivity model used is based on electron fluxes and mean energies measured from the S3-2 satellite. Joule heating of the upper atmosphere was found to be about 2 x 10 to the 11th W during the substorm period. Model values for the strength of the electrojet and the amount of Joule heating agree to within about 20% with results based on a simple Cowling conductivity band.

Karty, J. L.↗

Wind induced composition effects at high latitudes

The temperature and compositional structure of the upper atmosphere are discussed in relation to the impacts of wind-induced diffusion processes. Seasonal variations in thermospheric temperature and composition are explained by energy and mass transport from the summer to the winter hemisphere induced by preferential heating, with the winter oxygen bulge participating in a feedback mechanism which acts to dampen wind velocities and increase temperature contrast. Changes in the eddy diffusion coefficient are considered as a complementary mechanism of producing the seasonal anomalies. The role of winds induced by high-latitude heating by particles and Joule dissipation during magnetic storms and substorms in accounting for thermospheric density increases and N2 and Ar enhancements and O and He depletions at high latitudes are discussed, and the rather weak compositional signature of E x B momentum coupling is distinguished from the effects of Joule dissipation.

Mayr, H. G.↗

Energy sources of the high latitude upper atmosphere

Electrodynamic (Joule) dissipation and plasma wave heating are reviewed as sources of energy for the upper atmosphere at high latitudes. Electrodynamic heating in the thermosphere is described by a generalized energy balance equation taking into account a variety of inelastic processes and energy losses, and the use of height-integrated values of the Joule heating rate to estimate the importance of electrodynamic heating at high latitudes is discussed. Observations of electrons between 95 and 115 km altitude that are up to 1000 K hotter than the neutral atmosphere is presented as evidence for atmospheric heating due to unstable plasma waves arising from the Farley-Buneman modified two-stream instability.

Banks, P. M.↗