Search NASA⌕ Search

SEARCH · Search NASA

Results for “LAPSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Temperature lapse rate and methane in Titan's troposphere

We have reanalyzed the Voyager radio occultation data for Titan, examining two alternative approaches to methane condensation. In one approach, methane condensation is facilitated by the presence of nitrogen because nitrogen lowers the condensation level of a methane/nitrogen mixture. The resulting enhancement in methane condensation lowers the upper limit on surface relative humidity of methane obtained from the Voyager occultation data from 0.7 to 0.6. We conclude that in this case the surface relative humidity of methane lies between 0.08 and 0.6, with values close to 0.6 indicated. In the other approach, methane is allowed to become supersaturated and reaches 1.4 times saturation in the troposphere. In this case, surface humidities up to 100% are allowed by the Voyager occultation data, and thus the upper limit must be set by other considerations. We conclude that if supersaturation is included, then the surface relative humidity of methane can be any value greater than 0.08--unless a deep ocean is present, in which case the surface relative humidity is limited to less than 0.85. Again, values close to 0.6 are indicated. Overall, the tropospheric lapse rate on Titan appears to be determined by radiative equilibrium. The lapse rate is everywhere stable against dry convection, but is unstable to moist convection. This finding is consistent with a supersaturated atmosphere in which condensation-and hence moist convection-is inhibited.

Methane/analysis↗

Time-lapse analysis of gravitropism in Ceratodon protonemata

The tip cell of the protonema of the moss Ceratodon purpureus (Hedw.) Brid. is negatively gravitropic when grown in the dark on supplemented agar. Gravitropism, plastid distribution, and plastid movement were studied in living cells using time-lapse video microscopy and infrared light. A wrong-way (downward) curvature preceded upward curvature and was detected as early as 2 minutes after reorientation. Upward curvature began 30-45 minutes after reorientation to the horizontal. Cell division temporarily reversed upward curvature, but did not inhibit wrong-way curvature. Since significant amyloplast sedimentation always occurred before the start of upward curvature, it is possible that these amyloplasts function as statoliths for upward curvature. However, no significant amyloplast sedimentation occurred before wrong-way curvature. Thus, this early phase of gravitropism cannot require plastid sedimentation for gravity sensing. Most plastids moved within and between zones, and plastid zonation was highly dynamic. Plastids moved toward the apex and toward the base of the cell at rates much slower than cytoplasmic streaming. Despite the dynamic nature of plastid movement and zonation, during upward curvature the distance between sedimented plastids and the apex stayed constant. Time-lapse analysis has revealed intriguing events not readily seen previously using destructive sampling.

NASA Discipline Number 40-50↗

3D Time-Lapse Geophysical Imaging Evaluation of Contaminant Migration at the Hanford BY Cribs Site

Changes in bulk electrical conductivity are governed in large part by two diagnostic parameters concerning the state of vadose zone contamination: saturation and pore fluid conductivity. As a robust, remote, non-invasive, three-dimensional, and scalable imaging tool, time-lapse electrical resistivity tomography (ERT) can provide extensive diagnostic information concerning vadose zone contaminant distribution and migration by imaging changes in bulk electrical conductivity. We demonstrate long-term surface ERT monitoring of a ~70-m-thick contaminated vadose zone to investigate whether rising groundwater nitrate levels are caused by unanticipated vadose zone flux. A three-dimensional time-lapse image spanning 10 years (2007-2017) reveals the impacts of meteoric surface infiltration events, but ultimately supports the adequacy of current conceptual understanding by indicating that rising nitrate levels are not sourced in the vadose zone.

resisitivity, geophysics, contamination, monitorin↗

Time Lapse Charged Wellbore Casing Controlled Source Electromagnetic Surveys for Monitoring Injected Carbon Dioxide

Carbon dioxide (CO2) injection for enhanced oil recovery (EOR) and long-term carbon storage extends the life of an oil field while keeping CO2 out of the atmosphere. Monitoring CO2 migration during EOR operations is critical to maximizing production and detecting unexpected CO2 migration quickly. In this project, we monitor CO2 migration using time-lapse charged well casing controlled source electromagnetics (CSEM) at an active EOR site undergoing CO2 injection. Since the electrical conductivity of the reservoir changes as CO2 displaces other fluids, this novel survey technique aims to monitor CO2 injection effectively and unobtrusively from the surface via electromagnetic field measurements. Of four time-lapse field campaigns spaced over two years, we have completed two. Each campaign consists of a CSEM survey supplemented by magnetotelluric and time-domain electromagnetic surveys. In the CSEM survey, a transmitter delivers alternating current to the subsurface at frequencies from 0.125 Hz to 16 Hz using steel well casings as electrodes. Charged well casing surveys detect deeper conductivity contrasts than surveys that use only surface electrodes, allowing CO2 movement at the depth of the reservoir to be imaged more clearly. We transmit on two well pairs. One pair is oriented in the east-west direction, and the other is oriented in the northeast-southwest direction. Receiver stations measure orthogonal components of the electric and magnetic fields. The measurements are repeated at the same locations in each field campaign. Data differences between campaigns provide information about changes in the electrical conductivity of the subsurface. We present the latest results from this ongoing project, including modeling, survey design, data processing techniques, and preliminary results from the field campaigns.

Magnetic and electrical methods, Geomagnetic induc↗

3D Time-Lapse Geophysical Imaging Evaluation of Contaminant Migration at the Hanford BY Cribs Site - 18504

Changes in bulk electrical conductivity are governed in large part by two diagnostic parameters concerning the state of vadose zone contamination: saturation and pore fluid conductivity. As a robust, remote, non-invasive, three-dimensional, and scalable imaging tool, time-lapse electrical resistivity tomography (ERT) can provide extensive diagnostic information concerning vadose zone contaminant distribution and migration by imaging changes in bulk electrical conductivity. We demonstrate long-term surface ERT monitoring of a ∼70-m-thick contaminated vadose zone to investigate whether rising groundwater nitrate levels are caused by unanticipated vadose zone flux. A three-dimensional time-lapse image spanning 10 years (2007-2017) reveals the impacts of meteoric surface infiltration events, but ultimately supports the adequacy of current conceptual understanding by indicating that rising nitrate levels are not sourced in the vadose zone. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coda-wave interferometry analysis of time-lapse VSP data for monitoring geological carbon sequestration

Injection and movement/saturation of carbon dioxide (CO2) in a geological formation will cause changes in seismic velocities. We investigate the capability of coda-wave interferometry technique for estimating CO2-induced seismic velocity changes using time-lapse synthetic vertical seismic profiling (VSP) data and the field VSP datasets acquired for monitoring injected CO2 in a brine aquifer in Texas, USA. Synthetic VSP data are calculated using a finite-difference elastic-wave equation scheme and a layered model based on the elastic Marmousi model. A possible leakage scenario is simulated by introducing seismic velocity changes in a layer above the CO2 injection layer. We find that the leakage can be detected by the detection of a difference in seismograms recorded after the injection compared to those recorded before the injection at an earlier time in the seismogram than would be expected if there was no leakage. The absolute values of estimated mean velocity changes, from both synthetic and field VSP data, increase significantly for receiver positions approaching the top of a CO2 reservoir. Our results from field data suggest that the velocity changes caused by CO2 injection could be more than 10% and are consistent with results from a crosswell tomogram study. This study demonstrates that time-lapse VSP with coda-wave interferometry analysis can reliably and effectively monitor geological carbon sequestration.

54 ENVIRONMENTAL SCIENCES↗

Updated - Research Support Facility (RSF) construction time lapse

Haselden Construction and RNL built the 222,000 square-foot Research Support Facility (RSF) for the U.S. Department of Energy (DOE) on the National Renewable Energy Laboratory (NREL) campus. This time lapse video begins on July 23, 2009 and the last shot was taken in June 2010. The building is designed to be a model for sustainable, high-performance building design, and will provide DOE-owned work space for administrative staff who currently occupy leased space in the nearby Denver West Office Park. The engineers and scientists from NREL's Building Technology Program set the energy criteria and the energy design strategies that are making it possible for the RSF to use no more carbon-based energy than is produced by renewables. The RSF was designed by RNL. Stantec Consulting served as the project's engineering, energy modeling and sustainability consultant.

99 GENERAL AND MISCELLANEOUS↗

New Siemens Research Turbine - time lapse

The National Renewable Energy Laboratory (NREL) and Siemens Energy Inc. recently commissioned a new 2.3 megawatt Siemens wind turbine at NREL's National Wind Technology Center. This video shows a time lapse of the installation. The turbine is the centerpiece of a multi-year project to study the performance and aerodynamics of a new class of large, land-based machines — in what will be the biggest government-industry research partnership for wind power generation ever undertaken in the U.S.

17 WIND ENERGY↗

3D Time-Lapse Electrical Resistivity Imaging of Rock Damage Patterns and Gas Flow Paths Resulting from Two Underground Chemical Explosions

Abstract Rock damage from underground nuclear explosions (UNEs) has a strong influence on sub-surface gas movement and on seismic waveform characteristics, both of which are used to detect UNEs. Although advanced numerical simulation capabilities exist to predict rock damage patterns and corresponding detection signals, those predictions are dependent on (generally) unknown properties of the host rock. For example, the effects of in-situ mechanical heterogeneities on the explosively generated damage/fractures that provide gas flow pathways to the surface are not well understood, due largely to the difficulty in accessing and characterizing the near-source region. In this paper we demonstrate the emerging use of electrical resistivity tomography (ERT) for imaging rock damage and gas flow patterns resulting from two relatively small-scale underground chemical explosions. Pre-explosion ERT and crosshole seismic imaging revealed a natural fracture zone within the test bed. Post-explosion imaging revealed that the damage zone was non-symmetric and was focused primarily within the pre-existing fracture zone, located 10 m above the first explosion and 5 m above the second explosion. Time-lapse ERT imaging of heated air injected into the detonation borehole revealed the primary gas flow paths to be within the upper margin of the same primary damage zone. These results point to the utility of ERT imaging for understanding rock damage and gas flow patterns under experimental conditions, and to the importance of understanding the effects of geologic heterogeneity on UNE detection signals, particularly gas surface breakthrough times.

58 GEOSCIENCES↗

A poly(dimethylsiloxane)-based device enabling time-lapse imaging with high spatial resolution

We have developed a regulator-free device that enables long-term incubation of mammalian cells for epi-fluorescence imaging, based on a concept that the size of sample to be gassed and heated is reduced to observation scale. A poly(dimethylsiloxane) block stamped on a coverslip works as a long-lasting supplier of CO{sub 2}-rich gas to adjust bicarbonate-containing medium in a tiny chamber at physiological pH, and an oil-immersion objective warms cells across the coverslip. A time-lapse imaging experiment using HeLa cells stably expressing fluorescent cell-cycle indicators showed that the cells in the chamber proliferated with normal cell-cycle period over 2 days.

60 APPLIED LIFE SCIENCES↗

Time-lapse 3-D electrical resistance tomography inversion for crosswell monitoring of dissolved and supercritical CO 2 flow at two field sites: Escatawpa and Cranfield, Mississippi, USA

In this study, we advance the understanding of three-dimensional (3-D) electrical resistivity tomography (ERT) for monitoring long-term CO 2 storage by analyzing two previously published field time-lapse data sets. We address two important aspects of ERT inversion-the issue of resolution decay, a general impediment to the ERT method, and the issue of potentially misleading imaging artifacts due to 2-D model assumptions. The first study analyzes data from a shallow dissolved-CO 2 injection experiment near Escatawpa (Mississippi), where ERT data were collected in a 3-D crosswell configuration. Here, we apply a focusing approach designed for crosswell configurations to counteract resolution loss in the inter-wellbore area, with synthetic studies demonstrating its effectiveness. The 3-D field data analysis reveals an initially southwards-trending flow path development and a dispersing plume development in the downgradient inter-well region. The second data set was collected during a deep (over 3 km) injection of supercritical CO 2 near Cranfield (Mississippi). Comparative 2-D and 3-D inversions reveal the projection of off-planar anomalies onto the cross-section, a typical artifact introduced by 2-D model assumptions. Conforming 3-D images from two different algorithms support earlier hydrological investigations, indicating a conduit system where flow velocity variations lead to a circumvention of a close observation well and an onset of increased CO 2 saturation downgradient from this well. We relate lateral permeability variations indicated by an independently obtained hydrological analysis to this consistently observed pattern in the CO 2 spatial plume evolution.

3-D inversion↗

Time-lapse approach to correct deficiencies of 2D soil zymography

Membrane zymography is commonly used in rhizosphere ecology to map enzyme activities in intact soil samples and plant roots. The method consists of incubating a membrane saturated with an enzyme-specific fluorogenic substrate on the soil/root surface followed by measurements of fluorescence intensity of the product in the membrane. The traditional zymography is based on assumptions that fluorescence on membrane images is linearly increasing with time during zymography and an increase in product content is numerically equal to enzyme activity in soil below the membrane. These assumptions are unlikely to hold in experimental settings. In this work we introduce a new zymography technique, time-lapse zymography (TLZ); the approach that eliminates the need for assumptions of the traditional zymography and provides more realistic estimates of enzymatic activities. We assessed the new technique in a series of laboratory and modeling experiments, including quantification of the fluorescent product diffusion (e.g. MUF: 4-methylumbelliferone) from plant roots, enzyme activity measurements on the roots, and HYDRUS-2D & HP2 software calibration with obtained data. The calibrated model was used to analyze the processes governing spatial and temporal dynamics of MUF contents in the membrane. The results indicated that the enzyme diffusion within the membrane-soil system was negligible, and measured zymograms were adequately reproduced solely by accounting for substrate and product diffusions and for catalytic enzyme reaction described by the Michaelis-Menten equation. TLZ enabled identifying and using linear parts on MUF time series and accounting for MUF losses in each zymogram pixel, considerably improving the accuracy as compared to the traditional method. Results demonstrated that enzymatic activity from only a thin soil layer (~0.2 mm) is adequately represented in zymograms.

54 ENVIRONMENTAL SCIENCES↗

Application of quantitative time-lapse imaging (QTLI) for evaluation of Mrp2-based drug–drug interaction induced by liver metabolites

We previously reported a quantitative time-lapse imaging (QTLI)-based analysis method to assess drug–drug interactions (DDI) at multidrug resistance-associated protein 2 (Mrp2) in rat sandwich-cultured hepatocyte (SCH) system, utilizing the fluorescent Mrp2 substrate, 5-(and 6)-carboxy-2′,7′-dichlorofluorescein (CDF). Here, we aimed to examine the feasibility of using QTLI to evaluate DDI involving drug metabolite(s) generated in hepatocytes. We used estradiol (E2) and bilirubin as model compounds; both are not substrates of MRP2, whereas their hepatic metabolites, estradiol-17β-glucuronide (E17G) or bilirubin glucuronides, are known to be its substrates as well as inhibitors. When rat SCHs were pre-exposed with E2, fluorescence of CDF accumulated in bile canaliculi decreased depending upon both the duration of pre-exposure and the concentration of extracellular E2. The decrease corresponded with the increase in intracellular concentration of E17G in hepatocytes. Furthermore, cytotoxicity of vinblastine, a substrate of MRP2, was enhanced in SCHs treated with E2. Similarly, CDF accumulated in bile canaliculi was significantly reduced in rat SCHs pre-exposed with bilirubin. In conclusion, these results suggest that phase II biotransformation of a competitor is reflected in alteration of MRP2-mediated CDF transport detected in QTLI. The QTLI might provide a convenient platform to evaluate transporter-based DDIs involving hepatic metabolites of drug candidates without the need to identify the metabolites. -- Highlights: ► Mrp2-mediated CDF transport is inhibited by E2, but not E17G in vesicle study. ► Both E2 and E17G do not compromise CDF formation from CDFDA in hepatocytes. ► CDF accumulation in bile canaliculi is inhibited by E2 or E17G in QTLI. ► Increasing exposure to E2 decreases CDF accumulation in bile canaliculi in QTLI. ► QTLI is feasible to assess Mrp2-based DDI involving drug metabolite in hepatocytes.

60 APPLIED LIFE SCIENCES↗

Stochastic inversion of permeability and dispersivities from time lapse self‐potential measurements: A controlled sandbox study

We test the ability of the self‐potential method to provide information that can be used to invert the permeability and the dispersivities of a porous material. We first formulate the semi‐coupled system of equations describing the occurrence of self‐potential signals associated with the transport of salt in a porous material like sand. Two contributions in the source current density arise from the electrokinetic coupling associated with the flow of the pore water and the diffusion potential due to the gradient in the activity of the salt. A controlled laboratory sandbox experiment is performed to show that time‐lapse self‐potential measurements can be used to invert, in a Bayesian framework, the permeability and dispersivities.

self-potential, dispersivity, permeability↗

Inversion of Time-Lapse Seismic Reservoir Monitoring Data Using CycleGAN: A Deep Learning-Based Approach for Estimating Dynamic Reservoir Property Changes

Carbon capture and storage is being pursued globally as a geoengineering measure for reducing the emission of anthropogenic CO 2 the atmosphere. Comprehensive monitoring, verification, and accounting programs must be established for demonstrating the safe storage of injected CO 2 . One of the most commonly deployed monitoring techniques is time-lapse seismic reservoir monitoring (also known as 4-D seismic), which involves comparing 3-D seismic survey data taken at the same study site but over different times. Analyses of 4-D seismic data volumes can help improve the quality of storage reservoir characterization, track the movement of injected CO 2 plume, and identify potential CO 2 spillover/leakage from the storage reservoirblue. However, the derivation of high-resolution CO 2 saturation maps from 4-D seismic data is a highly nonlinear and ill-posed inverse problem, often requiring significant computational effort. In this research, we apply a physics-based deep learning method to facilitate the solution of both the forward and inverse problems in seismic inversion while honoring physical constraints. A cycle generative adversarial neural network (CycleGAN) model is trained to learn the bidirectional functional mappings between the reservoir dynamic property changes and seismic attribute changes, such that both forward and inverse solutions can be obtained efficiently from the trained model. We show that our CycleGAN-based approach not only improves the reliability of 4-D seismic inversion but also expedites the quantitative interpretation. Our deep learning-based workflow is generic and can be readily used for reservoir characterization and reservoir model updates involving the use of 4-D seismic data.

58 GEOSCIENCES↗

Coupled Time-Lapse Full-Waveform Inversion for Subsurface Flow Problems Using Intrusive Automatic Differentiation

We describe a novel framework for estimating subsurface properties, such as rock permeability and porosity, from time-lapse observed seismic data by coupling full-waveform inversion (FWI), subsurface flow processes, and rock physics models. For the inverse modeling, we handle the back propagation of gradients by an intrusive automatic differentiation strategy that offers three levels of user control: (1) At the wave physics level, we adopted the discrete adjoint method in order to use our existing high-performance FWI code; (2) at the rock physics level, we used built-in automatic differentiation operators from the TensorFlow backend; (3) at the flow physics level, we implemented customized partial differential equation (PDE) operators for the multiphase flow equations. The three-level coupled inversion strategy strikes a good balance between computational efficiency and programming efforts, and when the gradients are chained together, it constitutes a coupled inverse system. Our numerical experiments demonstrate that the three-level coupled inverse problem is superior in terms of accuracy to a traditional decoupled inversion strategy. Additionally, our method is able to simultaneously invert for parameters in empirical relationships such as the rock physics models. Our proposed inverted model can be used for reservoir performance prediction and reservoir management/optimization purposes.

54 ENVIRONMENTAL SCIENCES↗

Live Cells as Dynamic Laboratories: Time Lapse Raman Spectral Microscopy of Nanoparticles with Both IgE Targeting and pH-Sensing Functions

This review captures the use of live cells as dynamic microlaboratories through implementation of labeled nanoparticles (nanosensors) that have both sensing and targeting functions. The addition of 2,4-ε-dinitrophenol-L-lysine (DNP) as a FcεRI targeting ligand and 4-mercaptopyridine (4-MPy) as a pH-sensing ligand enables spatial and temporal monitoring of FcεRI receptors and their pH environment within the endocytic pathway. To ensure reliability, the sensor is calibrated in vivo using the ionophore nigericin and standard buffer solutions to equilibrate the external [ H + ] concentration with that of the cell compartments. This review highlights the nanosensors, ability to traffic and respond to pH of receptor-bound nanosensors (1) at physiological temperature ( 37 ° C ) versus room temperature ( 25 ° C ) , (2) after pharmacological treatment with bafilomycin, an H + ATPase pump inhibitor, or amiloride, an inhibitor of Na + / H + exchange, and (3) in response to both temperature and pharmacological treatment. Whole-cell, time lapse images are demonstrated to show the ability to transform live cells into dynamic laboratories to monitor temporal and spatial endosomal pH. The versatility of these probes shows promise for future applications relevant to intracellular trafficking and intelligent drug design.

59 BASIC BIOLOGICAL SCIENCES↗