Search NASASearch

SEARCH · Search NASA

Results for “Liquid Rocket Engine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

711 records · Page 5

Test Data Analysis of the Thermodynamic Vent System-Augmented Top Spray Injector Liquid Nitrogen Transfer Experiments

Traditionally, a cryogenic tank must be pre-chilled to some “target” temperature before the main vent valve can be closed to attempt a non-vented fill (NVF) of cryogenic liquid propellant. This methodology is particularly attractive for performing in-space transfer of cryogens due to the unknown location of the liquid/vapor interface in microgravity and the high likelihood of venting liquid if the vent valve is opened during transfer. This paper presents in-depth test data analysis of a Thermodynamic Vent System (TVS) augmented injector used for cryogenic tank chilldown and fill experiments of a thin-walled Titanium tank. Eight tests were conducted using liquid nitrogen across a range of inlet conditions and boundary conditions, and three different chilldown/fill methods. For four of the tests, the injector sprays liquid into the tank as normal, but also uses a TVS heat exchanger to cool the metallic injector itself as well as the main incoming liquid stream. Results show that using the TVS augmented injector simplifies transfer operation via enhanced condensation at the injector surface at the cost of sacrificing only a small amount of propellant.

Thermodynamic Vent System

Measurement of Interfacial Tension of Immiscible Liquid Pairs in Microgravity

A discussion is given of a containerless microgravity experiment aimed at measuring the interfacial tension of immiscible liquid pairs using a compound drop rotation method. The reasons for the failure to execute such experiments in microgravity are described. Also, the results of post-flight analyses used to confirm our arguments are presented.

Michael C Weinberg

Reflection and refraction of directrons at the interface

Reflection and refraction are ubiquitous phenomena with extensive applications, yet minimizing energy loss and information distortion during these processes remains a significant challenge. This study examines the behavior of structurally stable solitons, known as directrons, in nematic liquid crystals interacting with an interface where the director field orientation changes, despite identical physical properties, external potentials, and boundary anchoring in the two regions. During reflection and refraction, the directrons maintain nearly constant structure and velocity, ensuring energy conservation and information integrity. Microscopic analyses of the director field and macroscopic evaluations of effective potential are employed to elucidate the dependence of reflection and refraction probabilities on the directron’s incident angle and the orientation difference across the interface. The findings provide valuable insights into the dynamics of solitary waves in structured liquid crystal systems, offering significant implications for the development of tunable photonic devices, reconfigurable optical systems, and nanoscale material engineering.

Science & Technology - Other Topics

A Transient Hydrodynamic Model of Screen Channel Liquid Acquisition Devices for In-Space Cryogenic Propellant Management

Screen channel liquid acquisition devices (LADs) will play a crucial role in future deep space travel. It is essential that vapor-free delivery of propellants during tank-to-tank transfer is ensured to maximize yield from storage tanks and prevent potential combustion instabilities. The screen channel LAD utilizes a fine screen wire mesh that can separate phases in a low Bond number (i.e. microgravity) environment using surface tension forces. This study presents the development and verification of a new model for transient screen compliance, one of the influential factors for screen channel LAD design. Screen compliance is crucial during LAD channel outflow transients because the slight deflection of the screen can provide needed mass to satisfy rapid outflow demands and reduce the pressure difference across the screen. The model is successfully verified against CFD simulations. In addition, the characteristic speed for the governing screen compliance equations is derived which allows for numerical stability criteria to be established. As shown in this study, the transient maximum pressure difference across the screen can greatly exceed the steady state maximum pressure difference across the screen in many cases.

Hydrodynamics Simulations

Validation of Accurate Cryogenic Fluid Vapor-Liquid Boundary Conditions Via Molecular Simulations

Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.

Daniel Vigil

STS lithium/CF(x) battery

Lithium carbon fluoride batteries are used on Space Shuttle Rocket Boosters and external tanks. These batteries have been extremely successful in terms of mission reliability with the exception of cell yield variances. The function/system and battery descriptions are given. A description is given of the battery range safety system.

Gnacek, Dee

Reduced Order Models for Liquid Hydrogen Pooling and Vaporization Supported by Experiments

In the event of a leak of liquid hydrogen, a pool can form that vaporizes, disperses, and eventually dilutes to a non-flammable mixture. In this work, we describe fast-running models for the pooling and vaporization of liquid hydrogen in a steady cross-wind. Several pooling models from the literature are compared to solve for the flow and extent of the pool. The size of the pool can serve as the source for a separate dispersion model, which builds upon the existing one-dimensional Gaussian plume model in HyRAM+. Additional terms for the effects of a cross-wind on momentum and entrainment were added so that the model could handle the effects of a cross-wind on a low-speed flow. The models are compared to experimental data on pooling extent and downwind dispersion for steady flow rates of liquid hydrogen in a steady cross-wind. In the two compared experiments, liquid flow rates of 15 and 45 g/s were spilled onto concrete in cross-winds of approximately 1.8 m/s. The rate of growth of the pool and the downwind concentration boundaries are compared to the models, showing good agreement, although additional tuning is needed. These models can contribute to the advancement of codes and standards for liquid hydrogen systems.

dispersion

A Predictive Bubble Point Pressure Model for Porous Liquid Acquisition Device Screens

This article presents a simplified model for porous screen channel liquid acquisition devices based on a maximum bubble point pressure method from Adamson and Gast (1997). To validate the model, three 304 stainless steel (325 × 2300, 450 × 2750, and 510 × 3600) mesh samples were tested in methanol, acetone, isopropyl alcohol, and water. Screen pores are estimated based on analysis from scanning electron microscopy, historical data, and current test data. Results show that the bubble point pressure is proportional to the surface tension of the fluid only when accounting for nonzero contact angles. The previous assumption that bubble point pressure scales inversely with effective pore diameter is shown to be invalid, as the second finest 450 × 2750 produced the highest bubble point of the three screens. The simplified bubble point model can be used to make predictions for any pure fluid when pore diameters are based on bubble point tests and not SEM analysis.

Liquid Acquisition Device

Selective Binding and Light-Driven Release of Fluorous PF 6 – and Radioactive 99 TcO 4 – Anions for All-to-Nothing Liquid–Liquid Extraction

The removal of anions from aqueous media using molecular receptors in liquid–liquid extraction is a long-standing strategy to clean up contaminated water sources. Therein, high selectivity is needed to remove specific ions from mixtures of other ions, and high affinity provides extractions at low concentrations. However, the high affinity creates a conundrum by impeding the release of the ions in any stripping steps needed for further processing. To circumvent this problem, light-responsive receptors have been proposed as candidates for turning off the binding, but they are currently untested in liquid–liquid extraction. We tested the feasibility of light-driven release using a cyanostar macrocycle. We demonstrate the selective extraction of PF$^{–}_{6}$ anions over large excesses of competing anions (Cl – , NO$^{–}_{3}$, SO$^{2–}_{4}$) followed by photodriven release for quantitative isolation of the target. Release relies on photoisomerization of the macrocycle’s five stilbenes generating distorted isomers to turn off binding. With modest reversibility, only a single-shot release was demonstrated, akin to photodriven uncaging. These methods were extended to the capture and photodriven release of ReO$^{–}_{4}$ and radioactive 99 TcO$^{–}_{4}$ anions at ∼90% efficiency. Extraction was demonstrated down to the highly dilute 4 ppb levels of the 99 TcO$^{–}_{4}$ anion. Furthermore, this proof-of-concept demonstration verifies the use of a large change in affinity for the all-to-nothing capture and release of target anions between liquid phases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Bifurcation of Rotating Liquid Drops: Results From USML-1 Experiments in Space

Experiments on rotational bifurcation of liquid drops, in which the drops were levitated and spun using acoustic fields in a low-gravity environment, were conducted during the first United States Microgravity Laboratory (USML-1) Space Shuttle flight. The experiments have successfully resolved the discrepancies existing between the previous experimental results and the theoretical predictions. In the case of a spherical drop, for which theory exists, the results agree well with the predictions. In the case of flattened drops, the experiments have established a family of curves, with the spherical drop as the limiting case.

T G Wang

Analysis of Liquids Using the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER)

We developed a sensor called the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER) probe, which uses an atmospheric pressure glow discharge below the surface of liquids to excite species in the liquid. Through emission spectroscopy of molten salts, liquid metals, and heavy water, we demonstrated the SPIDER probe’s high resolution, accuracy, and versatility. We successfully identified trace concentrations of transition and rare-earth metals in molten salts and detected the isotopic shift of the H β → D β emission line. Our analysis revealed unconventional spectral alkali line shapes, indicating two competing excitation modes: film explosion and droplet vaporization. The film explosion mode, characterized by dense plasma, exhibited self-reversal and broadband continuum emission, while the droplet vaporization mode, associated with diffusive plasma, produced narrow-line emissions. Furthermore, by analyzing circuit transients alongside individual plasma events, we observed that film explosions generate higher currents, likely due to a shorter plasma length as the current preferentially flows through the thin liquid layer. Altogether, our results highlight the SPIDER probe’s efficacy and flexibility, making it well-suited for online material quantification of liquids in extreme environments.

AES

Insights into the thermo-hydraulic properties of compacted MX80 bentonite during hydration under elevated temperature

In high-level radioactive waste geological repositories, compacted bentonite undergoes coupled thermo-hydraulic processes due to heat released from a central waste canister and groundwater imbibition from the surrounding host rock. An understanding of these processes is essential for long-term simulations of radionuclide migration and canister corrosion, which requires an understanding of temperature effects on the coupled thermo-hydraulic properties governing these processes. In this study, a tank-scale radial infiltration test was used to investigate water imbibition processes in compacted bentonite under a central heater temperature of 200 °C that simulates high thermal gradients in a repository. Interpretation of this test focuses on evaluation of the liquid water wetting front during hydration and the interpretation of the temperature-dependent transient soil water retention curve (SWRC), thermal conductivity function (TCF), and hydraulic conductivity function (HCF). The SWRC during imbibition follows a temperature-dependent wetting path. Temperature effects on the hydraulic conductivity of bentonite in saturated conditions had the greatest effect on the shape of the HCF, with minimal temperature effects at higher suctions. The transient thermal conductivity data matched well with a new TCF linked with the SWRC shape. Although the bentonite layer was restrained, local deformations during hydration may have affected the shapes of the TCF and HCF.

Engineering