Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS SPECTROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Identification of Unique Fragmentation Patterns of Fentanyl Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

The opioid crisis in the United States is being fueled by the rapid emergence of new fentanyl analogs and precursors that can elude traditional library-based screening methods, which require data from known reference compounds. Since reference compounds are unavailable for new fentanyl analogs, we examined if fentanyls (fentanyl + fentanyl analogs) could be identified in a reference-free manner using a combination of electrospray ionization (ESI), high-resolution ion mobility (IM) spectrometry, high-resolution mass spectrometry (MS), and higher-energy collision-induced dissociation (MS/MS). We analyzed a mixture containing nine fentanyls and W-15 (a structurally similar molecule) and found that the protonated forms of all fentanyls uniquely exhibited two baseline separated IM distributions that produced different MS/MS patterns. Upon fragmentation, both IM distributions of all fentanyls produced two high intensity fragments resulting from amine site cleavages. The higher mobility distributions of all fentanyls also produced several low intensity fragments, but surprisingly, these same fragments exhibited much greater intensities in the lower mobility distributions. This observation demonstrates that many fragments of fentanyls predominantly originate from one of two different gas-phase structures (suggestive of protomers). Furthermore, increasing the water concentration in the ESI solution increased the intensity of the lower mobility distribution relative to the higher mobility distribution, which further supports that fentanyls exist as two gas-phase protomers. In conclusion, our new observations on the IM and MS/MS properties of fentanyls can be exploited to positively identify them as fentanyls without requiring reference libraries and will hopefully assist first responders and law enforcement in combating new and emerging fentanyls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chimera Spectrum Diagnostics for Peptides Using Two-Dimensional Partial Covariance Mass Spectrometry

The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.

47 OTHER INSTRUMENTATION↗

Internal Fragments Generated by Electron Ionization Dissociation Enhance Protein Top-Down Mass Spectrometry

Top-down proteomics by mass spectrometry (MS) involves the mass measurement of an intact protein followed by subsequent activation of the protein to generate product ions. Electron-based fragmentation methods like electron capture dissociation and electron transfer dissociation are widely used for these types of analyses. Recently, electron ionization dissociation (EID), which utilizes higher energy electrons (>20 eV) has been suggested to be more efficient for top-down protein fragmentation compared to other electron-based dissociation methods. In this paper, we demonstrate that the use of EID enhances protein fragmentation and subsequent detection of protein fragments. Protein product ions can form by either single cleavage events, resulting in terminal fragments containing the C-terminus or N-terminus of the protein, or by multiple cleavage events to give rise to internal fragments that include neither the C-terminus nor the N-terminus of the protein. Conventionally, internal fragments have been disregarded, as reliable assignments of these fragments were limited. Here, we demonstrate that internal fragments generated by EID can account for ~20–40% of the mass spectral signals detected by top-down EID-MS experiments. By including internal fragments, the extent of the protein sequence that can be explained from a single tandem mass spectrum increases from ~50 to ~99% for 29 kDa carbonic anhydrase II and 8.6 kDa ubiquitin. When searching for internal fragments during data analysis, previously unassigned peaks can be readily and accurately assigned to confirm a given protein sequence and to enhance the utility of top-down protein sequencing experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Liquid Chromatography Mass Spectrometry Instrumentation and Methodology

This report reviews instrumentation and techniques utilized in liquid chromatography mass spectrometry (LC-MS). The analytical advantages and disadvantages of each major component of different LC-MS systems are discussed, along with a comparison between LC-MS, liquid chromatography tandem mass spectrometry (LC-MS/MS), and gas chromatography mass spectrometry (GC-MS). This report also details future work regarding the use of LC-MS/MS to analyze and identify degradation products from an extensive accelerated aging process of nitroplasticizer (NP). This report is the first of a series on the use of LC-MS to understand the degradation mechanisms of NP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Determination of the Spatial Distribution of Indigenous Lipid Biomarkers in an Immature Jurassic Sediment Using Time-of-Flight–Secondary Ion Mass Spectrometry

The ability to detect and map lipids, including potential lipid biomarkers, within a sedimentary matrix using mass spectrometry (MS) imaging may be critical to determine whether potential lipids detected in samples returned from Mars are indigenous to Mars or are contaminants. Here, we use gas chromatography–mass spectrometry (GC-MS) and time-of-flight–secondary ion mass spectrometry (ToF-SIMS) datasets collected from an organic-rich, thermally immature Jurassic geologic sample to constrain MS imaging analysis of indigenous lipid biomarkers in geologic samples. GC-MS data show that the extractable fractions are dominated by C 27 –C 30 steranes and sterenes as well as isorenieratene derivatives. ToF-SIMS spectra from organic matter-rich laminae contain a strong, spatially restricted signal for ions m/z 370.3, m/z 372.3, and m/z 386.3, which we assign to C 27 sterenes, cholestane (C 27 ), and 4- or 24-methyl steranes (C 28 ), respectively, as well as characteristic fragment ions of isorenieratene derivatives, including m/z 133.1, m/z 171.1, and m/z 237.1. We observed individual steroid spatial heterogeneity at the scale of 10's to 100's of microns. The fine-scale heterogeneity observed implies that indigenous lipid biomarkers concentrated within specific regions may be detectable via ToF-SIMS in samples with even low amounts of organic carbon, including in samples returned from Mars.

59 BASIC BIOLOGICAL SCIENCES↗

Data and scripts associated with a manuscript investigating impacts of solid phase extraction on freshwater organic matter optical signatures and mass spectrometry pairing

This data package is associated with the publication “Investigating the impacts of solid phase extraction on dissolved organic matter optical signatures and the pairing with high-resolution mass spectrometry data in a freshwater system” submitted to “Limnology and Oceanography: Methods.” This data is an extension of the River Corridor and Watershed Biogeochemistry SFA’s Spatial Study 2021 (https://doi.org/10.15485/1898914). Other associated data and field metadata can be found at the link provided. The goal of this manuscript is to assess the impact of solid phase extraction (SPE) on the ability to pair ultra-high resolution mass spectrometry data collected from SPE extracts with optical properties collected on ambient stream samples. Forty-seven samples collected from within the Yakima River Basin, Washington were analyzed dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), absorbance, and fluorescence. Samples were subsequently concentrated with SPE and reanalyzed for each measurement. The extraction efficiency for the DOC and common optical indices were calculated. In addition, SPE samples were subject to ultra-high resolution mass spectrometry and compared with the ambient and SPE generated optical data. Finally, in addition to this cross-platform inter-comparison, we further performed and intra-comparison among the high-resolution mass spectrometry data to determine the impact of sample preparation on the interpretability of results. Here, the SPE samples were prepared at 40 milligrams per liter (mg/L) based on the known DOC extraction efficiency of the samples (ranging from ~30 to ~75%) compared to the common practice of assuming the DOC extraction efficiency of freshwater samples at 60%. This data package folder consists of one main data folder with one subfolder (Data_Input). The main data folder contains (1) readme; (2) data dictionary (dd); (3) file-level metadata (flmd); (4) final data summary output from processing script; and (5) the processing script. The R-markdown processing script (SPE_Manuscript_Rmarkdown_Data_Package.rmd) contains all code needed to reproduce manuscript statistics and figures (with the exception of that stated below). The Data_Input folder has two subfolders: (1) FTICR and (2) Optics. Additionally, the Data_Input folder contains dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data (SPS_NPOC_Summary.csv) and relevant supporting Solid Phase Extraction Volume information (SPS_SPE_Volumes.csv). Methods information for the optical and FTICR data is embedded in the header rows of SPS_EEMs_Methods.csv and SPS_FTICR_Methods.csv, respectively. In addition, the data dictionary (SPS_SPE_dd.csv), file level metadata (SPS_SPE_flmd.csv), and methods codes (SPS_SPE_Methods_codes.csv) are provided. The FTICR subfolder contains all raw FTICR data as well as instructions for processing. In addition, post processed FTICR molecular information (Processed_FTICRMS_Mol.csv) and sample data (Processed_FTICRMS_Data.csv) is provided that can be directly read into R with the associated R-markdown file. The Optics subfolder contains all Absorbance and Fluorescence Spectra. Fluorescence spectra have been blank corrected, inner filter corrected, and undergone scatter removal. In addition, this folder contains Matlab code used to make a portion of Figure 1 within the manuscript, derive various spectral parameters used within the manuscript, and used for parallel factor analysis (PARAFAC) modeling. Spectral indices (SPS_SpectralIndices.csv) and PARAFAC outputs (SPS_PARAFAC_Model_Loadings.csv and SPS_PARAFAC_Sample_Scores.csv) are directly read into the associated R-markdown file. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected some of these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Isotopic Heterogeneity Imaged in a Uranium Fuel Pellet with Extreme Ultraviolet Laser Ablation and Ionization Time-of-Flight Mass Spectrometry

We use extreme ultraviolet laser ablation and ionization time-of-flight mass spectrometry (EUV TOF) to map uranium isotopic heterogeneity at the nanoscale (=100 nm). Using low-enriched uranium fuel pellets that were made by blending two isotopically distinct feedstocks, we show that EUV TOF can map the 235U/238U content in 100 nm-sized pixels. The two-dimensional (2D) isotope maps reveal U ratio variations in sub-microscale to =1 µm areas of the pellet that had not been fully exposed by microscale or bulk mass spectrometry analyses. Compared to the ratio distribution measured in a homogeneous U reference material, the ratios in the enriched pellet follow a ~3× wider distribution. These results indicate U heterogeneity in the fuel pellet from incomplete blending of the different source materials. EUV TOF results agree well with those obtained on the same enriched pellets by nanoscale secondary ionization mass spectrometry (NanoSIMS), which reveals a comparable U isotope ratio distribution at the same spatial scale. EUV TOF’s ability to assess and map isotopic heterogeneity at the nanoscale makes it a promising tool in fields such as nuclear forensics, geochemistry, and biology that could benefit from uncovering sub-microscale sources of chemical modifications.

Rush, Lydia A.↗

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

High and Ultra-High Temperature Reaction Kinetics by Single Nanoparticle Mass Spectrometry

Methodology is presented for non-destructive, optically-detected single nanoparticle (NP) mass spectrometry, with the goal of extracting surface reaction kinetics for single NPs at high temperatures. Methods for determining the NP charge, mass, and temperature as a function of time are discussed, and the data are used to extract both the absolute kinetics for mass change, as well as the efficiencies of the surface processes that cause them. Factors that contribute to the uncertainties in absolute and relative mass determination, and in the resulting kinetic parameters, are discussed. The method allows the NP-to-NP variations in initial reactivity to be measured directly, along with the time evolution of reactivity resulting from NP structural/compositional changes that occur under reaction conditions. The strengths and limitations of single nanoparticle mass spectrometry as a high temperature surface kinetics tool are discussed in the context of sublimation and O2 oxidation kinetics experiments for single hafnium (Hf) NPs at temperatures ranging above 2400 K. The Hf oxidation kinetics are compared to analogous oxidation experiments for silicon, graphite, and carbon black NPs. In all four cases, the oxidation chemistry was dominated by processes that result in net mass loss, and the distinct mechanisms responsible are discussed. All four NPs also eventually passivated, i.e., the efficiencies for oxidative etching decreased by at least two orders of magnitude, relative to the initial efficiencies. Furthermore, the passivation mechanisms, which are quite different for carbon, compared to silicon or hafnium, are discussed. Carbon NP passivation is attributed to structural isomerization leading to fully coordinated, fullerene-like NP surfaces, while for silicon and hafnium, passivation results from delayed formation of an oxide layer, triggered by accumulation of oxygen in the NP sub-surface region.

36 MATERIALS SCIENCE↗

DEIMoS GUI: An Open-Source User Interface for a High-Dimensional Mass Spectrometry Data Processing Tool

In this paper, we report the creation of a graphical user interface (GUI) for the Data Extraction for Integrated Multidimensional Spectrometry (DEIMoS) tool. DEIMoS is a Python package to process data from high-dimensional mass spectrometry measurements. It is divided into several modules, each representing a data processing step, such as peak detection, alignment, and tandem mass spectra extraction and deconvolution. The inputs for and outputs from DEIMoS can include millions of N-dimensional data points, which can be challenging to visualize in a way that is interactive, informative, and responsive. Here, we used the HoloViz Python data stack, including DataShader and Param, to create an interactive visualization of mass spectrometry data. We believe the GUI will increase the accessibility of DEIMoS, and the visualization methods could be useful for other open-source mass spectrometry tools.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid quantification of alcohol production in microorganisms based on nanostructure-initiator mass spectrometry (NIMS)

We described a mass spectrometry-based assay to rapidly quantify the production of primary alcohols directly from cell cultures. This novel assay used the combination of TEMPO-based oxidation chemistry and oxime ligation, followed by product analysis based on Nanostructure-Initiator Mass Spectrometry. This assay enables quantitative monitor both C5 to C18 alcohols as well as glucose and gluconate in the growth medium to support strain characterization and optimization. We find that this assay yields similar results to gas chromatography for isoprenol production but required much less acquisition time per sample. We applied this assay to gain new insights into P. Putida's utilization of alcohols and find that this strain largely could not grow on heptanol and octanol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

National User Resource for Biological Accelerator Mass Spectrometry (Annual Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry Annual Report

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH-funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pharmacokinetics, Metabolite Measurement, and Biomarker Identification of Dermal Exposure to Permethrin Using Accelerator Mass Spectrometry

Impregnating military uniforms and outdoor clothing with the insecticide permethrin is an approach to reduce exposure to insect borne diseases and to repel pests and disease vectors such as mosquitos and sandflies, but the practice exposes wearers to prolonged dermal exposure to the pesticide. Key metabolite(s) from a low dose dermal exposure of permethrin were identified using accelerator mass spectrometry. Metabolite standards were synthesized and a high performance liquide chromatography (HPLC) elution protocol to separate individual metabolites in urine was developed. Six human subjects were exposed dermally on the forearm to 25 mg of permethrin containing 1.0 µCi of 14 C for 8 h. Blood, saliva and urine samples were taken for 7d. Absorption/elimination rates and metabolite concentrations varied by individual. Average absorption was 0.2% of the dose. Serum concentrations rose until 12–24 h postdermal application then rapidly declined reaching predose levels by 72 h. Maximum saliva excretion occurred 6 h postdosing. The maximum urinary excretion rate occurred during 12–24 h; average elimination half-life was 56 h. 3-Phenoxybenzyl alcohol glucuronide was the most abundant metabolite identified when analyzing elution fractions, but most of the radioactivity was in still more polar fractions suggesting extensive degradative metabolism and for which there were no standards. Finally, analyses of archived urine samples with the ultra performance liquid chromatography-accelerator mass spectrometry-mass spectrometry (UPLC-AMS-MS) system isolated a distinct polar metabolite but it was much diminished from the previous analyses a decade earlier.

59 BASIC BIOLOGICAL SCIENCES↗

Ion Mobility – Mass Spectrometry Rapid Imaging of Special Nuclear Materials

Robot Nose will use new fast data throughput methods and experience with laser microfocus to dramatically improve the speed and spatial resolution of an established instrument, making it a useful tool for imaging special nuclear materials (SNM). Mass spectrometry imaging instruments have traditionally been too slow and mass alone is generally an insufficient measurement for organic analyses. This situation was markedly improved by Ionwerks Inc., who pioneered the combination of ion mobility with mass spectrometry imaging. In 2D mobility-mass plots, clearly identifiable trend lines can be selected and reduced to 1D mass spectra without isobaric interferences. This is a major advantage over other imaging mass spectrometers that generally cannot distinguish isobars without custom-built lasers or high voltage accelerators. Special nuclear material (SNM) contains substantial fissile isotopes, particularly 233U, 235U, and 239Pu. A complete forensic analysis of SNM therefore requires quantitative isotopic measurement – often through some form of mass spectrometry. SNM contaminated with inclusions such as pollen grains can help identify its prior locations. The project team is presently working on an approach to allow rapid screening of 1-3 cm diameter thin samples of such material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zero voltage mass spectrometry probes and systems

The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗