Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Studies to Improve the Sensitivity to Low Energy Interactions in Dual-Phase Xenon Dark Matter Detectors. Department of Energy Office of Science Graduate Student Research (SCGSR) Program, Final project report

Noble liquid time projection chambers (TPCs) are some of the most sensitive particle detectors ever developed. They see use in searches for new physics with neutrinos, or for new particles like dark matter. They work by sensing light and charge signals left behind by particle interactions in a volume of liquified xenon or argon. TPCs are so sensitive that even a single electron liberated in an interaction can be readily detected. However this sensitivity to signals comes with a sensitivity to background noise, with one example being single electrons that arrive long after the signals from a true particle interaction. This type of noise has been the subject of multiple studies, which have concluded that single electron backgrounds are well correlated with prior events in the TPC, as well as impurities in the detection medium. At Lawrence Livermore National Laboratory (LLNL), the XeNu TPC is a testbed for a novel study of these backgrounds by generating data with new components made of aluminum and Shapal--the latter being an exotic ceramic which can be machined using standard tools. These materials were selected to replace plastic components which introduce impurities in the TPC during operation. Without plastic, the hope is that electron backgrounds will be reduced, leaving new opportunities for studying their origins and dependence on impurities. The SCGSR fellowship served as a springboard to help meet these objectives. Over the course of a year, the new components were designed, fabricated, and installed in XeNu. Following their installation, data was taken for use in a future study that will enable the electron background contributions from plastic components to be studied directly. In the interim, preliminary analysis results indicate that electron backgrounds with the new components are roughly 50% lower. This has established the efficacy of Shapal as a low-background replacement for plastic components where electrical and thermal stability are needed

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors

Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particle detectors. As these experiments seek to increase their sensitivity, novel and improved technologies will be needed to enhance the precision of their measurements and to broaden the reach of their physics programs. The areas of R&D in noble element instrumentation that have been identified by the HEP community in the Snowmass process are highlighted by five key messages: IF08-1) Enhance and combine existing modalities (scintillation and electron drift) to increase signal-to-noise and reconstruction fidelity; IF08-2) Develop new modalities for signal detection in noble elements, including methods based on ion drift, metastable fluids, solid-phase detectors and dissolved targets. Collaborative and blue-sky R&D should also be supported to enable advances in this area; IF08-3) Improve the understanding of detector microphysics and calibrate detector response in new signal regimes; IF08-4) Address challenges in scaling technologies, including material purification, background mitigation, large-area readout, and magnetization; and IF08-5) Train the next generation of researchers, using fast-turnaround instrumentation projects to provide the design-through-result training no longer possible in very-large-scale experiments. This topical group report identifies and documents recent developments and future needs for noble element detector technologies. In addition, we highlight the opportunity that this area of research provides for continued training of the next generation of scientists.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Noble Liquid Test Facility at Fermilab

The Noble Liquid Test Facility (NLTF) at Fermilab is a liquid argon detector R\&D facility open to the national and international HEP community. The facility consists of 4 permanent cryostats, ranging from 250L up to 3000L, open space for small open dewar testing, and an optical test stand facility capable of measuring the optical properties of materials and characterizing photon detectors. NLTF’s strongest advantage is its capability to provide ultra-pure LAr in a reliable manner. Its inline filters are capable of filtering all of the three biggest contaminants for standard LAr detectors, O$_2$ and H$_2$O down to $< 1$ppb and N$_2$ $< 1$ppm. This is critical for the users of the test stands as small levels of impurities can dramatically change the efficiency of LArTPCs for the collection of charge and light. The smallest cryostat is mainly used for material testing, a service provided to the international HEP community interested in understanding how the introduction of a specific material might affect the electron lifetime in LAr. The test stands can be equipped with a purity monitor, which allows measuring the electron lifetime in real time, as well as gas sampling and analyzing, and in the near future, local recirculation and filtering. The facility has hosted many successful R\&D projects, which have published their results in well-known journals and talks. A few examples of such projects are: NIR light production in LAr and GAr, the characterization of VUV metalenses, the testing of new filter media capable of filtering N$_2$ from LAr, high voltage studies and direct charge amplification in LAr, and various doping studies.

Blaszczyk, Flor María [Fermilab]↗

Characterization of the X-ARAPUCA Systems' Response for SBND's Light Detection

X-ARAPUCA waveform data, collected at a test stand at the Noble Liquid Test Facility (NLTF) and the Short Baseline Near Detector (SBND), were analyzed via python scripts. For the ARARA system, various distributions and correlations were studied, including the area and amplitude distributions of the waveform peaks for identifying single photoelectron peaks, as well as characterizing the behavior of the baseline artifact. The ARARA system is being studied in order to be implemented into SBND, just as the APSAIA X-ARAPUCAs have been.

Novotny, Andrew [U. Illinois, Chicago]↗

Characterization of the X-ARAPUCA systems' response for SBND's light detection

X-ARAPUCA waveform data, collected at a test stand at the Noble Liquid Test Facility (NLTF) and the Short Baseline Near Detector (SBND), were analyzed via python scripts. For the ARARA system, various distributions and correlations were studied, including the area and amplitude distributions of the waveform peaks for identifying single photoelectron peaks, which was able to be accomplished. The behavior of the baseline artifact was also characterized, which appeared only at high voltages/bright events, and separates further from the prompt peak as the voltage/brightness increases. The ARARA system is being studied in order to be implemented into SBND, just as the APSAIA X-ARAPUCAs have been.

Novotny, Andrew [Fermilab]↗

Readout of Large Capacitance SiPMs by Weak Coupling to Charge Sensitive Amplifier

Large area and large capacitance silicon photomultiplier (SiPM) arrays are employed to collect scintillation light in noble liquid time projection chambers (TPC) such as DarkSide, nEXO, MEGII, protoDUNE and DUNE. Light readout using ASICs designed for operation in noble liquids is a solution for large meter-scale photon detectors. However, conventional readout requires a high voltage decoupling capacitor larger than SiPM capacitance (in the range of tens of nF) to achieve full charge transfer to the preamplifier. Here, we demonstrate a readout concept by weakly coupling (via a capacitor lower by an order of magnitude than SiPM capacitance) to a charge sensitive amplifier, LArASIC in this case, without any loss in the signal to noise ratio (S/N). The single-photoelectron detection, signal-to-noise ratio, timing resolution, and coincidence detection are experimentally characterized.

47 OTHER INSTRUMENTATION↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers for the detection of sub-keV nuclear recoils. These detectors benefit from the electron recoil rejection inherent in moderately-superheated bubble chambers with the addition of energy reconstruction provided from the scintillation signal. The ability to measure low-energy nuclear recoils allows the search for GeV-scale dark matter and the measurement of coherent elastic neutrino-nucleus scattering on argon from MeV-scale reactor antineutrinos. The first physics-scale detector, SBC-LAr10, is in the commissioning phase at Fermilab, where extensive engineering and calibration studies will be performed. In parallel, a functionally identical low-background version, SBC-SNOLAB, is being built for a dark matter search underground at SNOLAB. SBC-SNOLAB, with a 10 kg-yr exposure, will have sensitivity to a dark matter–nucleon cross section of 2×10 –42 cm 2 at 1 GeV/c 2 dark matter mass, and future detectors could reach the boundary of the argon neutrino fog with a tonne-yr exposure. In addition, the deployment of an SBC detector at a nuclear reactor could enable neutrino physics investigations including measurements of the weak mixing angle and searches for sterile neutrinos, the neutrino magnetic moment, and the light Z’ gauge boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers to detect sub-keV nuclear recoils, allowing the search for low-mass (GeV-scale) dark matter and coherent elastic neutrino-nucleus scattering from low-energy (MeV-scale) neutrinos. The scintillating bubble chamber detectors benefit from the energy reconstruction that the scintillation signal gives in addition to the superior electron-recoil insensitivity that bubble chambers naturally provide. The high level of superheat achievable in noble liquids while being electron-recoil insensitive allows for lower nuclear recoil thresholds than in existing freon-based bubble chambers, potentially reaching the 100 eV threshold desired for reactor CEvNS measurements. To validate this lower threshold, the SBC collaboration is constructing two 10 kg detectors that are functionally identical. The SBC-LAr10, which is being commissioned at Fermilab, is intended for engineering and calibration research and has additional possibilities in assessing coherent elastic neutrino-nucleus scattering in argon. SBC-SNOLAB, the second detector for a low-background dark matter search, will be run at SNOLAB underground.

Pyda, Daniel [Unlisted, US]↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fundamental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr-based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared.

Gallego Ros, Ana↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fun- damental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr- based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared

Gallego-Ros, Ana↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Simulation to Interpret LArS's Results

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Noble Liquid Testing Facility (NLTF) at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced silicon photo multiplier (SiPM). With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.]↗

Gas electroluminescence in a dual phase xenon-doped argon detector

Noble element detectors using argon or xenon as the detection medium are widely used in the searches for rare neutrino and dark matter interactions. Xenon doping in liquid argon can preserve attractive properties of an argon target while enhancing the detectable signals with properties of xenon. Here, in this work, we deployed a dual-phase liquid argon detector with up to 4% xenon doping in the liquid and studied its gas electroluminescence properties as a function of xenon concentration. At ∼2% xenon doping in liquid argon, we measured ∼34 ppm of xenon in the gas and observed ∼2.5 times larger electroluminescence signals using vacuum ultraviolet silicon photomultipliers than those in pure argon. Analysis of signals of different wavelengths confirms that the argon gas electroluminescence process is strongly modified by the addition of xenon. We propose an analytical model to describe the underlying energy transfer mechanism in argon-xenon gas mixtures. Lastly, the implications of this measurement for low-energy ionization signal detection will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$\nu$NS Detection

The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering (CE$\nu$NS) of low-energy (MeV-scale) neutrinos. The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This device will calibrate the background discrimination power and sensitivity of superheated argon to nuclear recoils at energies down to 100 eV. A second functionally-identical detector with a focus on radiopure construction is being built for SBC's first dark matter search at SNOLAB. The projected spin-independent sensitivity of this search is approximately $10^{-43}$ cm$^2$ at 1 GeV$/c^2$ dark matter particle mass. The scalability and background discrimination power of the liquid-noble bubble chamber make this technique a compelling candidate for future dark matter searches to the solar neutrino fog at 1 GeV$/c^2$ particle mass (requiring a $\sim$ton-year exposure with non-neutrino backgrounds sub-dominant to the solar CE$\nu$NS signal) and for high-statistics CE$\nu$NS studies at nuclear reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗