Search NASASearch

SEARCH · Search NASA

Results for “PACE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

PACE-2 and Beyond

• Payload Accelerator for CubeSat Endeavors (PACE) goals are to mature Payloads through the NASA Space Technology Mission Directorate (STMD) Small Spacecraft Technology Program (SSTP) and Flight Opportunities Program (FOP) • The PACE series of projects will support flight demonstrations of new technologies, capabilities and applications for small spacecraft and reduces the cost, risk, complexity and/or time required to advance the state -of-the-art utilizing both suborbital and orbital launches

CubeSat Technology Demonstration

Pre-Launch Characterization of the Hyperspectral Ocean Color Instrument on NASA’s Pace Mission

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. Like its predecessors, OCI provides two day global coverage of top-of-atmosphere radiances. Unlike its predecessors, OCI covers a spectral range from 340 nm to 2260 nm. Below 900 nm, OCI provides hyperspectral radiances sampled every 2.5 nm or 1.25nm, with a bandwidth of 5 nm for each channel. Its spatial resolution is about 1.2km. The high radiometric accuracy of OCI was made possible by a thorough and extensive prelaunch characterization campaign, conducted at NASA’s Goddard Space Flight Center. This presentation describes the prelaunch radiometric characterization (approach and results) of OCI, such as e.g. the linearity correction, signal to noise ratio, polarization, IFOV, relative spectral response, radiometric gain, temperature sensitivity, optical crosstalk, and response versus scan angle.

Gerhard Meister

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration

Characterization of ELM pacing via vertical jogs on DIII-D

Edge localized mode (ELM) pacing via vertical plasma oscillations or jogging has been successfully demonstrated on DIII-D. Rapid vertical movement of the plasma toward the X-point has been shown to effectively trigger ELMs. By vertically oscillating the plasma at a rate of 10 Hz, the ELM frequency increased from ~5 Hz, the natural ELM frequency in similar DIII-D discharges, to 20 Hz. Downward jogs have been observed to trigger multiple ELMs in one cycle. ELMs triggered at higher than natural frequencies lead to smaller decreases in stored energy, from 8% to as little as below 1%. As a consequence, the peak heat flux to the divertor has been observed to be reduced by a factor of ~2. In addition, a reduction in the carbon impurity concentration has been observed. During downward jogs in the lower single null (LSN) configuration, the X-point movement is slower and smaller than the top of the plasma. As a result, a reduction in the plasma cross-section and hence volume has been observed. To understand the mechanism of ELM triggering by jogging, a toy model of the edge toroidal current has been built and tested with DIII-D experiment data. The experimental data and model suggest that when the plasma moves down toward the X-point, a net positive toroidal current is locally induced in the edge region. ELITE stability analysis suggests that this current pushes the plasma state across the peeling side of the peeling–ballooning stability boundary into the unstable region triggering ELMs.

ELM pacing

Simulating response versus scan angle characterization on OCI for the upcoming PACE mission

The Plankton, Aerosol, Cloud ocean Ecosystem (PACE) mission Ocean Color Instrument (OCI) is the next generation ocean color sensor following on from the SeaWiFS and VIIRS designs, to be launched into low Earth orbit in 2022. Like those heritage sensors, OCI has cross track scanning fore-optics, the reflectivity of which (referred to here as the response versus scan angle or RVS) must be characterized prior to launch. The expected test setup, component reflectivity measurements, instrument model, and heritage sensor testing were used to generate simulated RVS data. This simulated data set was then used to verify the functionality of the analysis software in preparation for the upcoming ground test campaign. The analysis software is designed to characterize the RVS for all OCI bands over the full range of scan angles to be measured on orbit as well as verify compliance with the sensor design requirements in near real-time.

PACE

Progressive TDI Measurements with the PACE OCI ETU

The Plankton Aerosol Cloud ocean Ecosystem (PACE) Ocean Color Instrument (OCI) has completed the ground test program for its engineering unit (ETU) and testing of the flight unit will begin in the near future. OCIis a grating spectrometer with hyperspectral coverage from about 340 nm to 885 nm with 9 additional filtered channels in the SWIR. Two CCDs are used as detectors for the hyperspectral channels. One important operating mode of the CCDs on OCI is progressive time delay integration (or PTDI). In this mode, the charge in the CCD can be held for multiples of the nominal integration times. A series of these measurements can be made with progressively increasing multiples of the nominal integration time as the instrument scans across a uniform source. Ground testing with this operating mode on OCI ETU has shown promising results. This work will present measurements taken with the PTDI mode and the analysis of OCI ETU linearity and dynamic range

PACE

PACE OCI Pre-launch ETU Spectral Characterization and Performance

The Ocean Color Instrument (OCI) is the primary sensor on the upcoming Plankton, Aerosol, Cloud ocean Ecosystem (PACE) mission. OCI is a new type of sensor compared to NASA’s ocean color heritage sensors VIIRS, MODIS, and SeaWiFs. Unlike its heritage sensors, OCI has two slit grating hyperspectral spectrographs in addition to a fiber-coupled multiband filter spectrograph. The two hyperspectral spectrographs provide continuous coverage from 340nm to 885nm in the UV to NIR range. These spectrographs use programmable CCD detectors that aggregate multiple CCD pixels that can effectively provide various spectral resolutions. The fiber-coupled multiband filter spectrograph provides seven discrete spectral bands from 940nm to 2260nm. OCI completed system level testing of the Engineering Test Unit (ETU) in June 2021 at the Goddard Space Flight Center (GSFC). The ETU contains one of the slit grating spectrographs (600nm to 885nm) and the fiber-coupled spectrograph. The ETU was tested in thermal vacuum (TVAC) in February 2020 and January 2021 to assess characterization and performance compliance to design requirements. This paper presents an overview of the spectral performance of the OCI ETU for relative spectral response (RSR), integrated Out-of-Band response (IOOB), system gain, band centers, and bandwidths.

PACE

PACE OCI Short-Wave Infrared Detection Assembly Optical System Design, Alignment, and Environmental Test

The Ocean Color Instrument (OCI), which will be integrated with the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) satellite, will collect science data that will be used to monitor the health of Earth’s oceans and atmosphere. The Short-Wave Infrared (SWIR) Detection Assembly (SDA), built and characterized by Utah State University Space Dynamics Laboratory (SDL), is a subsystem of OCI consisting of 32 channels covering seven discrete optical bands of interest. A total of 16 SWIR Detection Subassemblies (SDSs) compose the SDA and house the cold optical system. The science data optical input for each SDS is supplied by a 0.22 NA multimode fiber interfacing with a fiber adapter. The diverging light from the fiber is collimated, split by a dichroic beamsplitter to two separate channels, filtered by the science filter, and then reimaged onto the single-element detectors with a final 0.76 NA. Aspheric, diamond-turned powered elements are used throughout the optical design. Fabrication and alignment tolerance analysis/budgets are balanced to ensure the optical system meets throughput requirements. All systems are aligned at ambient temperature using an InSb camera and an in-line illumination microscope system to directly image the active detector area through the science filters. Compensators used during alignment are detector focus and decenter, which are adjusted via photoetched shims in increments of 25 µm. Average focus and centering errors were less than 8 µm among all 32 flight and 10 flight spare detectors. Each SDS spectral response and conversion gain was verified at operational temperature of -65°C in vacuum.

OCI

Spatial Characterization of PACE OCI ETU Using Time-Delay Mode

The OCI (Ocean Color Instrument) is the main sensor on the upcoming PACE (Plankton Aerosol Cloud ocean Ecosystem) mission. OCI has two hyperspectral CCD sensors covering 340nm to 885nm and 9 SWIR (Short Wave IR) bands from 940nm to 2260nm. SWIR bands have nominal 1km ground pixel size and CCD bands have native 1/8 km ground pixel size in diagnostic mode that will be aggregated into 1km pixels to improve SNR and meet the data rate constraints. OCI has a rotating telescope that is synchronized to the readout of the CCD and SWIR detectors. Full pre-launch system level testing for the OCI ETU (Engineering Test Unit) was completed in June 2021.With time-delayed scan mode, a sub-pixel level time-delay step is applied to the detector readout. This sub-pixel level time-delay step causes a sub-pixel level shift in the start of the data collection. After collecting time-delay step scans with different step sizes, a scan profile with sub-pixel resolution can be constructed. 1/8 and 1/4 of CCD pixel resolutions were achieved using this mode. In this paper, the OCI time-delayed scan mode will be described as well as how it was used to calculate OCI’s high spatial resolution PSF (Point Spread Function), IFOV (instantaneous Field of View), MTF (Modulation Transfer Function), and BBR (Band to Band Registration).

PACE

Spectral Responses of the PACE OCI Short-Wave Infrared Detection Assembly

The Ocean Color Instrument (OCI) to go on the Plankton, Aerosol, Cloud, ocean Ecology (PACE) Earth-observing satellite has a Short-wave infrared (SWIR) Detection Assembly (SDA). This SDA is used to measure upwelling radiation in seven discrete bands from 940 to 2260 nm. There are redundant measurements of each band for a total of 32 physical channels, which includes optical components through to detection. The relative spectral response (RSR) is measured for each channel, which is needed when accounting for the spectral distribution of sensed radiance. From the RSR, single-value performance metrics are computed including the center wavelength, the full width at half of the maximum (FWHM), and the full width at 1% of the maximum (FW1P). Besides in-band responses, the out-of-band rejection ratio (OOBRR) is also calculated for each of the channels, which is a measure of the sensitivity outside the band of interest. We find that all 32 SDA detection channels meet the spectral response requirements at the qualification temperatures at which tests were conducted.

PACE

PACE OCI Polarization Sensitivity Based on Pre-launch Testing

The Ocean Color Instrument (OCI) is a sensor on the upcoming Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, scheduled for launch in early 2024. OCI is a grating spectrometer with hyperspectral coverage from the ultraviolet (about 310 nm) to near-infrared (about 900 nm), with additional filtered channels in the short-wave infrared (940 nm – 2260 nm). This instrument will provide ocean color science data to continue the data sets collected by heritage sensors MODIS, SeaWiFs, and VIIRS, but with increased spectral coverage and improved accuracy. In order to achieve the high levels of accuracy demanded by the science community, a rigorous ground test program was conducted to calibrate the instrument and ensure that the calibration can be transferred to on-orbit operations. Some calibration parameters can only be measured during pre-launch testing; one such parameter is the polarization sensitivity. Polarization testing measured the Mueller matrix components needed to determine the polarization sensitivity for all spectral bands for a series of telescope scan angles covering the expected on-orbit scan range. Results indicate that the sensitivity is below 0.6 % except at the shortest wavelengths (less than 340 nm) and was characterized to better than 0.1 % above 340 nm. This indicates that any polarized scenes measured on orbit can be corrected for with a high degree of confidence.

PACE

PACE OCI Polarization Sensitivity Based on Pre-launch Testing

The Ocean Color Instrument (OCI) is a sensor on the upcoming Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, scheduled for launch in early 2024. OCI is a grating spectrometer with hyperspectral coverage from the ultraviolet (about 310 nm) to near-infrared (about 900 nm), with additional filtered channels in the short-wave infrared (940 nm – 2260 nm). This instrument will provide ocean color science data to continue the data sets collected by heritage sensors MODIS, SeaWiFs, and VIIRS, but with increased spectral coverage and improved accuracy. In order to achieve the high levels of accuracy demanded by the science community, a rigorous ground test program was conducted to calibrate the instrument and ensure that the calibration can be transferred to on-orbit operations. Some calibration parameters can only be measured during pre-launch testing; one such parameter is the polarization sensitivity. Polarization testing measured the Mueller matrix components needed to determine the polarization sensitivity for all spectral bands for a series of telescope scan angles covering the expected on-orbit scan range. Results indicate that the sensitivity is below 0.6 % except at the shortest wavelengths (less than 340 nm) and was characterized to better than 0.1 % above 340 nm. This indicates that any polarized scenes measured on orbit can be corrected for with a high degree of confidence.

PACE

Pulse Response of the Short-Wave Infrared Detection System of the Ocean Color Instrument for the NASA PACE Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a hyperspectral Earth imager with a spatial resolution of 1 km x 1 km and a spectral resolution of 5 nm in 2.5 nm steps over 342-887 nm. In addition, OCI provides 7 discrete bands in the 940-2260 nm Short-Wave InfraRed (SWIR) range. The front-end optical imager is a rotating mirror-based system that images the ground scene onto a slit with an instantaneous field of view of 16 km x 1 km. For the SWIR bands, the slit-image is re-imaged onto a 16x1 micro-lens array that effectively acts as the focal plane since each lens element is fiber coupled to wavelength filtered InGaAs and HgCdTe Photo Diodes (PDs). The pulse response of the detection system is critical to OCI SWIR performance. We find that PDs introduce an inherent slow tail in the pulse response due to slow diffusion moving carriers in their n and p regions. We show that this introduces response errors ranging from 1 down to 0.01 % for up to tens of science pixels after the pulse depending on the PD design and materials. It is shown that the response is distinctly different for the InGaAs and HgCdTe PDs. We explain how the front-end design can further increase this error. Finally, we detail the cause of the slow pulse response tail, how to model it, its impact on OCI performance and how it is characterized and corrected to meet OCI requirements.

ocean color

Pulse Response of the Short-Wave Infrared Detection System of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a hyperspectral Earth imager with a spatial resolution of 1 km x 1 km and a spectral resolution of 5 nm in 2.5 nm steps over 342-887 nm. In addition, OCI provides 7 discrete bands in the 940-2260 nm Short-Wave InfraRed (SWIR) range. The front-end optical imager is a rotating mirror-based system that images the ground scene onto a slit with an instantaneous field of view of 16 km x 1 km. For the SWIR bands, the slit-image is re-imaged onto a 16x1 micro-lens array that effectively acts as the focal plane since each lens element is fiber coupled to wavelength filtered InGaAs and HgCdTe Photo Diodes (PDs). The pulse response of the detection system is critical to OCI SWIR performance. We find that PDs introduce an inherent slow tail in the pulse response due to slow diffusion moving carriers in their n and p regions. We show that this introduces response errors ranging from 1 down to 0.01 % for up to tens of science pixels after the pulse depending on the PD design and materials. It is shown that the response is distinctly different for the InGaAs and HgCdTe PDs. We explain how the front-end design can further increase this error. Finally, we detail the cause of the slow pulse response tail, how to model it, its impact on OCI performance and how it is characterized and corrected to meet OCI requirements.

ocean color

Pace OCI Crosstalk Characterization Based on Pre-Launch Testing

Scheduled to launch in 2024, the Ocean Color Instrument (OCI) onboard the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission will collect hyperspectral data from 315 nm – 895 nm via two grating spectrometers (in both the blue and red spectral regions) and 9 multi-spectral bands in the short-wave infrared (940 nm – 2260 nm). The increased spectral resolution and radiometric accuracy is expected to improve upon data collected by heritage sensors such as SeaWiFs, MODIS, and VIIRS, allowing new applications in ocean color, aerosol, and cloud science. During ground testing, higher than expected spatial-spectral crosstalk was measured for the hyperspectral bands in the blue spectrograph. Using a monochromatic-collimated light source, light from a single science pixel (1km x 1km) was found to produce crosstalk signals over 31 pixels in the cross-track direction. This spatial augmentation is caused by the spectral crosstalk’s asynchronous spatial movement during Time Delay Integration (TDI). To fully characterized the magnitude and spectral dependency from this, a crosstalk model was developed by synthesizing data collected from monochromatic-collimated light and monochromatic light that filled the OCI optical aperture. The model was validated by showing good agreement between predicted values and other relevant test data collected using both monochromatic and white light sources.

PACE