Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Simulation of Radiation-Induced DNA Damage With the Code RITRACKS

INTRODUCTION DNA damage is one of the most physiologically important effects of ionizing radiation. Clustered DNA damage events, like double-strand breaks (DSBs), have the most notable biological consequences. DNA damage types depend on both the track structure of the radiation and the spatial organization of the DNA. High linear energy transfer (LET) charged nuclei, found in galactic cosmic rays (GCR), are known to produce large numbers of complex DNA damage events. The human genome is packaged into chromatin, which can take on locus-dependent and cell type-dependent spatial conformations that correspond to epigenetic states, such as more open, extended structures in transcriptionally active chromatin. These epigenetic differences can affect DNA break patterns in response to ionizing radiation, potentially creating distinct DNA repair and signaling outcomes across the genome in different cells. MATERIAL AND METHODS The code RITRACKS (Relativistic Ion Tracks), which simulates stochastic radiation track structures and radiation chemistry, was used to model damage on isolated and histone-bound DNA by various types of ions and photons. The changes made to the code to perform radiation-induced DNA damage, and simulation results on single nucleosomes are given in our recent paper. In this work, the DNA building capabilities of RITRACKS have been extended to simulate more complex DNA structures build on the coarse-grain simulation framework meso-WLCsim. This code can sample generic chromatin fiber conformation ensembles based on the geometry of nucleosomes and mechanical properties of DNA. Using RITRACKS, we simulated the fragment length distributions (FLD) of irradiated DNA structures built using the chromatin conformations of WLCsim and obtained results representative of those obtained with Radiation-Induced Correlated Cleavage with sequencing (RICC-Seq) experiments [6]. We have also performed Fe ion and photon irradiations of K562, IMR90, BJ and RPE-1 cells at NSRL to experimentally validate results. Sample processing and data analysis are in progress and any available preliminary results will be discussed. DISCUSSION The recent updates in the code RITRACKS allow the calculation of several quantities such as the DNA damage yield and the FLD. This approach can be used to model epigenetic state-specific chromatin structure parameters to leverage the epigenetic state data available for many human cell types to infer relative DNA damage sensitivity among genomic loci.

I Plante↗

Impact of Storage Conditions on the Quality and Viability of Switchgrass as a Bioenergy Crop

With growing energy demands and climate concerns, advancements in bioenergy have become imperative. Biofuels promote energy independence, reduce fossil fuel reliance, and cut greenhouse gas emissions. Switchgrass (Panicum virgatumis) is an ideal bioenergy crop due to its ability to thrive on marginal lands unsuitable for food crops and its drought tolerance, rendering it a low-maintenance, high-yield option. In the bioenergy industry, energy crops are typically stored to facilitate supply chain management and ensure a continuous supply despite seasonal availability. However, the effective utilization of bioenergy crops is typically contingent upon addressing the challenges associated with biomass storage. These challenges include high moisture content that promotes biological degradation of the biomass leading to increased risk of pathogenic microbes, and chemical degradation that increases the ratio of inconvertible, inorganic materials. These issues lead to a reduction of feedstock value, diminishing the biomass-to-biofuel conversion efficacy, making switchgrass and other bioenergy crops less effective as fuel sources. This project aims to improve the storage of purpose-grown energy crops. Aerobic storage trials were conducted under varying moisture contents to stimulate real-world environmental exposure. Switchgrass samples were rewetted to 30% or 35% and stored in a bioreactor for approximately one month, or until cellular respiration ceased. Degradation indicators, such as dry matter loss, temperature changes, and cellular respiration, were measured throughout this process. Samples for compositional analysis, 16S, and ITS were taken at three different time points: before, during, and after storage, to monitor changes in biomass, microbial communities, and metabolites over time. Preliminary data indicate that dry matter loss is proportional to cellular respiration, with higher moisture content (35%) leading to higher temperatures and elevated dry matter loss. Compositional analysis and microbial community analysis are in progress. This research will provide a comprehensive understanding of storage, helping to identify stability factors in energy crops and improve best management practices for biomass producers.

09 - BIOMASS FUELS↗

Design and Development of a Miniaturized Double Latching Solenoid Valve for the Sample Analysis at Mars Instrument Suite

The development of the in-house Miniaturized Double Latching Solenoid Valve, or Microvalve, for the Gas Processing System (GPS) of the Sample Analysis at Mars (SAM) instrument suite is described. The Microvalve is a double latching solenoid valve that actuates a pintle shaft axially to hermetically seal an orifice. The key requirements and the design innovations implemented to meet them are described.

Smith, James T.↗

Sample processor for chemical analysis

An apparatus is provided which can process numerous samples that must be chemically analyzed by the application of fluids such as liquid reagents, solvents and purge gases, as well as the application of dumps for receiving the applied fluid after they pass across the sample, in a manner that permits numerous samples to be processed in a relatively short time and with minimal manpower. The processor includes a rotor which can hold numerous cartridges containing inert or adsorbent material for holding samples, and a pair of stators on opposite sides of the rotor. The stators form stations spaced along the path of the cartridges which lie in the rotor, and each station can include an aperture in one stator through which a fluid can be applied to a cartridge resting at that station, and an aperture in the other stator which can receive the fluid which has passed through the cartridge. The stators are sealed to the ends of the cartridges lying on the rotor, to thereby isolate the stations from one another.

Boettger, Heinz G.↗

Demonstration and Validation of a Portable Raman Sensor for In-Situ Detection and Monitoring of Perchlorate (ClO 4 - )

Costs for environmental analysis and monitoring are increasing at a rapid rate and represent a significant percentage of the total and future remedial expenses at many U.S. Department of Defense (DoD) contaminated sites. It has been reported that about 30 to 40% of the remediation budget is usually spent on long-term monitoring (LTM), of which a large percentage represents laboratory analytical costs. Energetics such as perchlorate (ClO 4 - ) are among the most frequently detected contaminants in groundwater and surface water at or near military installations due to their persistence and mobility. Currently, the standard protocol entails collecting samples in the field, packaging them, and shipping them overnight to a designated laboratory for analysis. This process requires significant sample preparation and handling, and analytical results may not be available for several days to weeks. In this project, we developed and demonstrated a portable Raman sensor based on surface enhanced Raman scattering (SERS) technology to detect ClO 4 - in contaminated water. We summarize major accomplishments as follows: • A SERS sensor based on elevated gold (Au) nano-ellipse dimer architectures was designed and developed for ClO 4 - with a detection limit of ~10 -6 M (or 100 μg/L); The performance of these sensors was evaluated and optimized through variation of their geometric characteristics (i.e., dimer aspect ratio, dimer separation, etc.). • Large-scale commercial production of SERS substrate sensors via nanoimprinting by Nanova Inc. and Nanoimprint lithography (NIL) technology was successfully demonstrated. This is a substantial step forward toward the commercialization of the SERS sensors and may potentially lead to significantly reduced fabrication costs of SERS substrates. • Commercially produced SERS sensors were demonstrated to detect ClO 4 - at levels above 10 -6 M using a portable Raman analyzer. The performance of the commercial SERS sensors for ClO 4 - detection in the presence and absence of interferences was determined for a series of standard solutions. Sulfate (SO 4 2- ) was found to exhibit the greatest interference for the anions tested, which included Cl-, NO 3 - , and SO 4 2- . • Field demonstration of the portable Raman sensor with commercially produced SERS substrates was completed at two Department of Defense (DoD) sites; twice at the Indian Head Naval Surface Warfare Center, Indian Head, MD, and once at Redstone Arsenal, Huntsville, AL. Multiple wells were sampled at both DoD sites, where a standard addition method was employed using the sensor to determine the ClO 4 - 4 - and possibly other energetics that are both important for environmental monitoring and of interest for national security. However, we point out that SERS technology is also prone to interferences due to its sensitivity and responses to other ionic species, such as NO 3 - , SO 4 2- , and dissolved organics or co-contaminants present in the groundwater, which could potentially mask the SERS signal of the target analyte (i.e., ClO 4 - ). As such, SERS analysis was subject to significant variations (e.g., ±20% or more), and its detection limit for ClO 4 - -8 M) and was substantially higher than what we anticipated from laboratory studies. However, despite these complications, the portable Raman sensor developed in this project could be used as a rapid screening tool for ClO 4 - at concentrations above 10 -6 M. Future studies are warranted to further develop the technology and to optimize its performance, and eventually to bring the technology to the market. With additional development and demonstration, the sensor has the potential to reduce analytical costs by eliminating shipping and typical costs associated with laboratory analysis. A cost savings of 30–45% may be realized during a typical sampling event and, more importantly, the technology could allow rapid turn-around of information to decision makers for site characterization and remediation.

47 OTHER INSTRUMENTATION↗

Sample processing approach for detection of ricin in surface samples

With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80 mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. Here, the procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required.

54 ENVIRONMENTAL SCIENCES↗

A method for processing the Confidential Carload Waybill Sample for railroad freight analysis

Freight transportation research is often constrained by the availability of appropriate data. Within the context of freight rail research, use of traditional freight datasets present some critical challenges. Aggregating freight data to geographic areas diminishes the ability to perform nuanced analysis. More challenging, the complexity of railroad operations limits the usability of publicly available freight flow data which do not account for which rail company is economically and legally responsible for the movement of the goods or for the contractual arrangements between infrastructure owners and carriers. Finally, detailed data are usually privately owned and not readily-accessible for analysis outside the individual rail companies. As part of their regulatory authority, the Surface Transportation Board has developed the Confidential Carload Waybill Sample, a stratified sample representing 1% to 3% of all rail traffic in the United States for a particular year. While the sample is rich with data, it is limited in spatial information as well as in its implementation in geospatial analysis. This paper introduces a methodology for geospatially enabling the Confidential Carload Waybill Sample which can then be used to generate rail routes based on a topological representation of the U.S. railroad network. As a result, this methodology is applied using two case studies, a freight diversion analysis and transporting hazardous materials.

42 ENGINEERING↗

Materials processing in low gravity

Activities of the Materials Processing in Low Gravity Program in which the University of Alabama in Huntsville (UAH) designed, fabricated, and performed various low gravity experiments in materials processing between October 26, 1988 through October 25, 1989 are discussed. Details of low gravity experiments using the Drop Facilities at the Marshall Space Flight Center (MSFC) and the KC-135 aircraft at Ellington Field are discussed. This effort included the defining of experimental requirements and equipment, experiment-facility integration requirements, building/assembling the necessary experiment apparatus, and conducting experiments which will contribute to the knowledge base for commercialization of materials processing in low gravity. UAH also performed logistical support needed to execute the experimentation, the necessary sample preparation, metallography analysis, and physical properties measurements of the processed samples.

Workman, Gary L.↗

Advanced Techniques for Sample Processing of the Reusable Metal-Containing Raw Material (Review)

A review of the sample processing of different types of reusable metal-containing material (catalytic agents, e-wastes, cuttings, etc.) is given in the article; the purpose of the sample processing is the further analysis in the form of solutions: dilution in the mineral acid mix, alloying with different fluxes, leaching, etc. Increase in the temperature and pressure, ultrasonic impact, and microwave radiation are applied for the purpose of sample processing intensification. Methods of sample processing with application of sorbate concentration for the further definition of not only the noble, nonferrous, and rare metals but also the toxic elements are described. The review shows that the stage of sample processing is very important for achieving the potential of the applied analytical methods.

36 MATERIALS SCIENCE↗

Investigating Amino Acid Heterogeneity in Milligram-Scale Samples of the Murchison CM2 Carbonaceous Chondrite

Analyses of different aliquots of the Tagish Lake meteorite have resulted in amino acid abundance variations of an order of magnitude or more, even when performed using the same techniques, by the same personnel, in the same laboratories (e.g., Simkus et al. 2019). Up to ~five-fold variations have been observed for specific amino acids in different samples of the same meteorite, such as α aminoisobutryic acid (AIB) in Murchison. These variations are often attributed differing sample composition or differing alteration history, neither of which is mutually exclusive. Distinguishing between these two explanations is challenging and time consuming, requiring detailed mineralogical analyses to be performed in conjunction with high precision organics analysis. The potential for innate sample-level heterogeneity presents a significant complication when parsing the effects of different processes or conditions during preparation of meteorite samples for analysis, as differences in organic yields or abundances could be due to differences in laboratory processing or differences among the samples themselves. In this work, we investigated the degree of innate organic heterogeneity present in a single ~250 mg chip of divided into 21 samples.

A. S. Burton↗

Site 200 #1400 Block Area New Trailers Project, Soil Sampling and Analysis Plan/Quality Assurance Plan

Lawrence Livermore National Laboratory's (LLNL) Project Management Office (PMO) is proposing to install a series of modular trailers and install associated underground utilities in the 1400 Block at the Livermore Site. This Sampling and Analysis Plan (SAP) outlines the processes and procedures to collect environmental and geotechnical soil samples from the project area and to send the samples to the appropriate laboratory or laboratories for analysis or testing. The resulting environmental laboratory data will determine whether excavated soils can be reused on the project, or which type of landfill or landfills the soils may be sent for disposal. This SAP has been prepared and is organized to be consistent with LLNL's Soils Screening and Management Plan (SSMP) (LLNL, 2019), as well as the U.S. Environmental Protection Agency's (EPA) Data Quality Objectives programs (EPA, 2006).

54 ENVIRONMENTAL SCIENCES↗

Towards a Theory of Sampled-Data Piecewise-Deterministic Markov Processes

The analysis and design of practical control systems requires that stochastic models be employed. Analysis and design tools have been developed, for example, for Markovian jump linear continuous and discrete-time systems, piecewise-deterministic processes (PDP's), and general stochastic hybrid systems (GSHS's). These model classes have been used in many applications, including fault tolerant control and networked control systems. This paper presents initial results on the analysis of a sampled-data PDP representation of a nonlinear sampled-data system with a jump linear controller. In particular, it is shown that the state of the sampled-data PDP satisfies the strong Markov property. In addition, a relation between the invariant measures of a sampled-data system driven by a stochastic process and its associated discrete-time representation are presented. As an application, when the plant is linear with no external input, a sufficient testable condition for the convergence in distribution to the invariant delta Dirac measure is given.

Herencia-Zapana, Heber↗

Facility Improvements and Modifications to Extend the Operational Life of the Modular Caustic-Side Solvent Extraction Process - 16082

Savannah River Remediation, LLC (SRR) is working to remove, stabilize, and dispose of approximately 36.7 million gallons (138.9 million liters) of liquid radioactive waste currently stored in 43 underground waste tanks, and ultimately close waste tanks. In 2008, as an interim salt treatment system to remove cesium from high level waste salt solutions prior to the Salt Waste Processing Facility start up, the Modular Caustic-Side Solvent Extraction Unit (MCU) initiated the removal of cesium from liquid radioactive salt waste prior to disposal. The MCU was designed and built for an expected three-year operational life and five-year design life. The first MCU cold runs began in June 2007 and hot startup was completed in April 2008. MCU remains in hot operation to this day, aiding in multiple, high-level tank closures. In an effort to continue liquid waste disposition at the Savannah River Site (SRS), equipment upgrades and operational improvements have been made to extend the life of the MCU beyond the original three years. Several pieces of fixed equipment have been converted into removable equipment which reduces the downtime associated with equipment change-outs and thereby reduces the dose to workers and processing impacts. Multiple pumps and filters have been upgraded to more robust designs. Process monitoring and controls have been upgraded to improve process performance. Redundant centrifugal contactor vibration equipment has been installed on each contactor in order to better assess the reliability, processing performance, and lifetime of the contactors. A new Solvent Hold Tank (SHT) Sampler has been installed to minimize the organic cross-contamination within the sampler, dose to workers, and sample analysis time. To increase processing availability and aid in visually obtained data, camera port has been added to the Salt Solution Feed Tank (SSFT). In order to decrease the overall background dose to the workers, the Process Vessel Ventilation (PVV) duct work now has the capability to be flushed to remove contamination. The caustic wash addition system has been modified to be a once-through system to improve equipment reliability, decrease downtime, and decrease dose to workers. In addition, the solvent that MCU utilizes to extract Cesium out of salt waste has been upgraded to Next Generation Solvent (NGS) which is based on MaxCalix extractant instead of a BobCalix extractant. Further, these upgrades and improvements have allowed MCU to be able to process at higher flow rates (up to 8.5 GPM) and with increased throughput (as high as 1.3 million gallons in FY13 and 5.3 million gallons since hot operations initiated) that have allowed SRR to continue the disposition of nuclear salt waste. The continued operation of MCU ensures more curies are stabilized into a glass matrix at SRS's Defense Waste Processing Facility (DWPF) and less curies are retained within South Carolina at SRS's Saltstone Disposal Facility (SDF). Unique challenges associated with modifying and improving a demonstration plant that is in hot operations and was designed to be temporary with a limited plant footprint have been successfully overcome. Further, creative strategies for removing old equipment have been utilized given the limited decontamination agents available for use that will not interfere with the organic solvent. This paper presents and discusses the deployment of these upgrades and operational improvements to MCU in order to allow continued, increased salt waste processing beyond the initial design life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chapter 4.2 - Preparation of nanoparticles for surface analysis

A variety of methods used to prepare nano-objects for surface analysis are described along with information about when they might be best applied. Intrinsic properties of NPs that complicate their characterization and need to be considered when planning for surface or other analyses of NPs are identified, including challenges associated with reproducible synthesis and functionalization of the particles as well as their dynamic nature. Information about the sample preparation processes, along with analysis data, that need to be added to the collection of material provenance information is identified and examples of protocols that have been successfully used for preparation of nano-objects for surface analysis are included in an annex.

characterization challenges↗

Recent Results of the Investigation of a Microfluidic Sampling Chip and Sampling System for Hot Cell Aqueous Processing Streams

A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and microfluidics sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The microfluidic-based robotic sampling system’s mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of microfluidic sampling chips.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent results of the investigation of a micro-fluidic sampling chip and sampling system for hot cell aqueous processing streams

A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and micro-fluidic sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. Different sampling volumes have been tested. It appears that the 10 μl volume has produced data that had much smaller relative standard deviations than the 2 μl volume. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The micro-fluidic-based robotic sampling system's mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of micro-fluidic sampling chips. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗