Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Full-Array Noise Performance of Deployment-Grade SuperSpec mm-Wave On-Chip Spectrometers

SuperSpec is an on-chip filter bank spectrometer designed for wideband moderate-resolution spectroscopy at millimeter wavelengths, employing TiN kinetic inductance detectors. SuperSpec technology will enable large-format spectroscopic integral field units suitable for high-redshift line intensity mapping and multi-object spectrographs. In previous results, we have demonstrated noise performance in individual detectors suitable for photon noise-limited ground-based observations at excellent mm-wave sites. Here, we present the noise performance of a full R similar to 275 spectrometer measured using deployment-ready RF hardware and software. We report typical noise equivalent powers through the full device of similar to 3x10 -16 W Hz -1/2 at expected sky loadings, which are photon noise dominated. Based on these results, we plan to deploy a six-spectrometer demonstration instrument to the Large Millimeter Telescope in early 2020.

47 OTHER INSTRUMENTATION↗

Design and Characterization of the 162.5 MHz RF Component Layout for Fermilab's PIP-II Reference Line

The Proton Improvement Plan II (PIP-II) Reference Line at Fermi National Accelerator Laboratory distributes phase-stable radio-frequency (RF) signals throughout the accelerator. PIP-II requires stable timing and phase reference signals so its accelerating cavities transfer energy to the particle beam at the correct point in each RF cycle. The full system includes 162.5, 325, and 650 MHz sections corresponding to the frequency sections of the PIP-II Linac, with this project focusing on the 162.5 MHz section. The Reference Line must provide a phase stable source signal while responding to phase changes caused by environmental conditions or system drift. Its RF components will be mounted on aluminum heat plates inside a temperature controlled enclosure to further limit temperature-driven phase changes. To prepare the system for manufacture, the project reviewed component functions and dimensions, developed a computer-aided design (CAD) model, and arranged the hardware to support short cable paths, grounding, fastener access, and maintenance. Several full scale, three dimensional printed prototypes allowed the available components to be mounted and inspected. These fit checks revealed mechanical conflicts and guided revisions to component placement, countersink geometry, labeling, and plate thickness. Electrical characterization was also performed on selected RF hardware to compare its measured behavior with the performance metrics that were set for our design. Overall, the project produced a manufacturable 162.5 MHz layout, physical fit-check prototypes, and documented electrical measurements that support review before metal fabrication. The 325 and 650 MHz layouts remain future work because they require additional minor mechanical changes.

Subedi, Harsheet [Unlisted, US, CA] (ORCID:0009000↗

N 2 vibrational excitation in atmospheric pressure ns pulse and RF plasma jets

Time-resolved N 2 vibrational temperature and translational–rotational temperature in quasi-two-dimensional atmospheric pressure plasma jets sustained by ns pulse and RF discharges in nitrogen/noble gas mixtures are measured by the broadband vibrational Coherent Anti-Stokes Raman Scattering (CARS) . The results indicate a much stronger vibrational excitation in the RF plasma jet, due to the lower reduced electric field and higher discharge power. In a ns pulse discharge in N 2 /He, N 2 vibrational temperature is significantly lower compared to that in N 2 /Ar, due to the more rapid vibration–translation (V–T) relaxation of nitrogen by helium atoms. In the RF plasma jets in N 2 /Ne and N 2 /Ar, the vibrational excitation increases considerably as the nitrogen fraction in the mixture is reduced. The experimental data in the RF plasma jet in N 2 /Ar jet are compared with the kinetic modeling predictions. The results indicate that nitrogen vibrational excitation in N 2 /Ar plasma jets with a small N 2 fraction in the mixture (several percent) is controlled primarily by electron impact, anharmonic vibration–vibration (V–V) pumping, and V–T relaxation by N atoms. In comparison, V–V energy transfer from the vibrationally excited molecules in the first excited electronic state, N 2 (A 3 Σ u + , v), which are generated primarily by the energy transfer from the metastable Ar atoms, has a minor effect on the vibrational populations of the ground electronic state, N 2 (X 1 Σ g + , v). Although the discharge energy fraction going to electronic excitation is significant, the predicted quasi-steady-state N 2 (A 3 Σ u + ) number density, controlled by the energy pooling and quenching by N atoms, remains relatively low. Because of this, the net rate of N 2 (X 1 Σ g + ) vibrational excitation by the V–V energy transfer from N 2 (A 3 Σ u + ) is much lower compared to that by the direct electron impact. Furthermore, the results show that atmospheric pressure RF plasma jets can be used as sources of highly vibrationally excited N 2 molecules and N atoms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Prompt Fission Uranium Neutron Spectrum (PFUNS) Experiment: Critical Configurations and Irradiations

The objective of the Prompt Fission Uranium Neutron Spectrum (PFUNS) experiment is to reduce the uncertainty of the Prompt Fission Neutron Spectrum (PFNS) of 235 U above 8 MeV. The experiment was performed at the DOE National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site. To meet the experiment objective, activation foils were placed in a central void region of a critical configuration consisting of concentric highly enriched uranium (HEU) metal hemishells. The set of activation foils were chosen based on threshold reactions to neutron energies across the fission spectrum, but especially those in the high energy tail of the fission spectrum. PFUNS was performed on the Planet critical assembly machine at NCERC and uses the Rocky Flats (RF) HEU hemishells. PFUNS has similarities to the Measurement of Uranium Subcritical and Critical (MUSiC) experiment conducted at NCERC in 2021, which also used RF hemishells, but contains a large central cavity to allow for a sample plate to be inserted. This large void means that much more HEU is needed to achieve a critical configuration (108 kg for PFUNS versus 59 kg for MUSiC). This work describes the 2024 experiment execution of four critical configurations and two irradiations for the PFUNS project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Understanding carbon sourcing and transport originating from the helicon antenna surfaces during high-power helicon discharge in DIII-D Tokamak

The high-power helicon wave system in the DIII-D tokamak could potentially introduce new plasma–material interaction (PMI) challenges owing to rectified RF sheath potentials that develop near the antenna and surrounding plasma-facing components. We present the first application of the STRIPE (Simulated Transport of RF Impurity Production and Emission) framework to helicon-induced PMIs, extending previous STRIPE studies of ICRH antennas by incorporating net erosion, local re-deposition, and three-dimensional global impurity transport. The integrated workflow couples SOLPS, COMSOL, RustBCA, GITR, and GITRm to simulate carbon erosion, re-deposition, and impurity transport for two experimentally constrained DIII-D H-mode helicon operating scenarios with different antenna–plasma gaps, coupled RF powers, and edge plasma conditions. COMSOL predicts rectified RF sheath potentials of 1–5 kV localized near the lower portion of the antenna, where the magnetic field intersects the surface at grazing incidence. Carbon self-sputtering dominates the erosion source, whereas RF-accelerated D + ions contribute approximately 1% of the total gross erosion. The smaller-gap operating scenario exhibits substantially stronger gross erosion, enhanced local re-deposition (∼12%), and a larger confined carbon inventory owing to increased plasma accessibility and broader RF sheath coverage. Comparison with available DIII-D measurements shows no distinct change in the global carbon signal that correlates with the helicon RF pulse, consistent with the simulations indicating that the helicon-generated carbon source remains small compared with the existing background carbon inventory under the present graphite-wall operating conditions. These results demonstrate the capability of STRIPE to integrate RF sheath modeling, plasma transport, surface interaction physics, and three-dimensional impurity transport for the interpretation of helicon-induced PMIs. The study further identifies the principal sources of modeling uncertainty, including grazing-angle RF sheath physics, slow-wave resolution, plasma-background extrapolation, and trace-impurity transport assumptions, providing a framework for future validation and model development.

Kumar, Atul [Oak Ridge National Laboratory (ORNL),↗

The geometry of the ICRF-induced wave–SOL interaction. A multi-machine experimental review in view of the ITER operation

As a part of ITPA-Integrated Operational Scenario activities, this contribution reviews recent experimental characterizations of radio-frequency (RF)-induced scrape-off layer (SOL) modifications of various tokamaks worldwide and of the LArge Plasma Device at UCLA. The phenomenology, as observed using a large variety of measurement techniques, is consistent with expectations from RF sheath rectification. Emphasis is then put on the complex three-dimensional (3D) spatial patterns of the RF–SOL interaction, in relation to the magnetic topology and the spatial distribution of RF currents over the metallic structures surrounding the RF wave launchers. Dependence on the local plasma parameters in the antenna vicinity is also briefly addressed. The final part discusses implications for future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-Situ Laser-Induced-Desorption-Spectroscopy Diagnostic Deployment on the Linear Plasma Device CSDX

A calibrated laser induced desorption diagnostic (LIDS) concept is developed under this award for application to fusion relevant plasma materials interactions studies. Small areal amounts of hydrogenic release from a deuterium filled PMI target are measured and quantified when irradiated by a LID flash heat event on the target surface. Good success was demonstrated by this project with the PISCES-E rf plasma device at UCSD by fully quantified measurement and removal of D from W-D co-deposit layers in experiments. However, adapting the LIDS technique to D plasma exposed W targets in the linear plasma CSDX device, now labelled PISCES-Rf, was prone to several technical challenges ranging from target line of sight access, laser focusing, and loss of optical spectroscopic signal strength in the larger PISCES-Rf vacuum system. The results are summarized in this report.

08 HYDROGEN↗

Correlating Nb-SRF Surface Processing with Evolution of Surface Electronic States

The few nanometers of the surface exposed to RF field plays a major role in defining the RF performance of superconducting cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in cavity performance by simultaneously achieving high Q with increasing Eacc. These processing methods include: thermal treatment under ultra-high vacuum (UHV) conditions across lo¬¬¬¬¬¬¬w-, mid-, and high-temperature ranges and high temperature treatments under controlled N2 atmosphere. These processes also produce distinct surface oxide configurations with different valence states, thicknesses, and uniformity, as well as different oxygen concentration profiles in bulk Nb. In this work, we are trying to understand how do surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity? With the help of Fermilab’s in-house X-ray photoemission facility and, in collaboration with the synchrotron-based angle-resolved photoemission (ARPES) facility at Argonne National Laboratory, we are investigating how the valence band structure and density of states (DoS) near the Fermi level modify with different surface treatments. Our observations show that different surface-processing methods lead to distinct evolutions of the valence-band states near the Fermi level during the superconducting transition. This behavior suggests variations in Nb-O orbital hybridizations and points towards the possibility of different underlying mechanisms of superconductivity governed by the surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in SRF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of SRF cavities.

Tripathi, Malvika [Fermilab]↗

Development of Improved Noble Liquid Purity Measurements (Final Technical Report)

The main goal of the Detector R&D project supported by this grant, “Development of Improved Noble Liquid Purity Measurements”, was to perform a scoping study of the feasibility of trapping ions in a liquid argon medium using a radiofrequency (RF) quadrupole trap, and to subsequently use the population of trapped ions to make measurements of the properties of the liquid medium. Using RF quadrupole traps immersed in a noble liquid to trap ions may yield new capabilities to detect and quantify the presence of impurities, as well as enabling other measurements of the microphysics in a noble liquid environment. The major activities undertaken during this project include: the development of a simulation of ions in a liquid argon medium; the designing of a prototype RF quadrupole trap; and the setup of hardware to be used in testing the prototype in vacuum and gas conditions. The summary of these major activities is reported here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved bound on nonlinear quantum mechanics using a cryogenic radio frequency experiment

There are strong arguments that quantum mechanics may be nonlinear in its dynamics. A discovery of nonlinearity would hint at a novel understanding of the interplay between gravity and quantum field theory, for example. As such, experiments searching for potential nonlinear effects in the electromagnetic sector are important. Here, in this study, we outline such an experiment, consisting of a stream of random bits (which were generated using Rigetti’s Aspen-M-3 chip) as input to an rf signal generator coupled to a cryogenic detector. Projective measurements of the qubit state, which is originally prepared in an equal superposition, serve as the random binary output of a signal generator. Thereafter, spectral analysis of the rf detector would yield a detectable excess signal predicted to arise from such a nonlinear effect. A comparison between the projective measurements of the quantum bits vs the classical baseline showed no power excess. This sets a new limit on the electromagnetic nonlinearity parameter |ε| ⪅ 1.15 x 10 -12 , at a 90.0% confidence level. This is the most stringent limit on nonlinear quantum mechanics thus far and an improvement by nearly a factor of 50 over the previous experimental limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ X-ray measurements over large Q-space to study the evolution of oxide thin films prepared by RF sputter deposition

Sputter deposition is a versatile and industrially important deposition technique for thin films, with increasing demand for matching the characteristics of thin film materials to specific requirements. Additionally, the actual film properties are largely determined by sputtering parameters such as pressure conditions, temperature and power settings. By means of various X-ray diffraction and scattering techniques, it is shown that the characterization of film formation and growth is feasible in real time at synchrotron sources, thus adding an important dimension to the fundamental understanding of the evolution of thin film microstructure. In particular, grazing incidence small-angle X-ray scattering, grazing incidence X-ray powder diffraction and X-ray reflectometry are used in a complementary manner to study the influence of deposition temperature and substrate choice on the crystallization kinetics and growth of polycrystalline BaTiO 3 films.

36 MATERIALS SCIENCE↗

Gridded RF Gun Design for SRF Linac Applications

The thermionic gridded gun is described which generates short electron bunches for further acceleration in a Nb3Sn conduction cooled SRF linac. The gun is built into the first cavity of the 250 keV injector [1] for the 20 kW, 10 MeV, 1.3 GHz CW conduction cooled one-cavity linac. The beam current is 2 mA. The RF gun design is presented as well as the results of perveance measurements, which are in a good agreement with the design parameters. The design of the RF resonator of the gun is presented also. The beam generated by the gun is matched to the injector to provide lack of current interception in the SRF cavity.

43 PARTICLE ACCELERATORS↗

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]↗

PIP-II LLRF Master Oscillator and Precision Reference Line- Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase synchronization throughout the accelerator. Temperature-induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the master oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods support repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago; Fermilab]↗

Improving Nb3Sn Cavity Performance Using Centrifugal Barrel Polishing

Nb3Sn superconducting radiofrequency (SRF) cavities have been an ongoing research topic for many years motivated by the potential for higher accelerating gradients and quality factors compared to niobium SRF cavities. The highest performing Nb3Sn cavities are manufactured using tin vapor-diffusion coating, which creates a Nb3Sn film with a surface roughness of around 100-200 nm. This is thought to be one of the limiting factors for the accelerating gradient of Nb3Sn cavities due to enhancement of magnetic field near sharp surface features. To smooth Nb3Sn SRF cavities, we have developed a mechanical polishing procedure which uses centrifugal barrel polishing to smooth the surface followed by a secondary tin coating step to repair the surface. We show that the accelerating field of a Nb3Sn SRF cavity is improved by applying this procedure. We also investigate the quench mechanism of the polished cavity by utilizing temperature mapping to measure which regions of the cavity e xperience heating during RF operation. We then cut samples from these regions and analyze the film microstructure and chemical composition in 3D using EDS and EBSD measurements together with a focused ion-beam (FIB) tomography technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identifying Nuclear Data Correlated Through Predicting Bias in Integral Experiments via Applying Principal Component Analysis to Random Forest

ABSTRACT Nuclear data (ND) are the input data for neutron‐transport simulations to answer questions related to nuclear technologies. Subsets of ND, here > 20,000 data points, are validated with respect to thousands of criticality experiments that represent various applications on a small scale. The aim of validation with these experiments is to find errors in ND or methods. The key challenge here is that several hundreds of ND are used to simulate one integral value. Hence, one cannot clearly identify what ND are leading to bias in criticality measurements. In fact, a mistake in one nuclear‐data observable can be compensated with an error in another, and the predicted criticality value would still be predicted in agreement with experimental data. Random forest (RF) was previously employed to predict bias in criticality measurements using sensitivities of simulated criticality experiments to ND. The SHapley Additive exPlanations (SHAP) metric was then applied to attribute the importance of each ND experiment and observable to bias prediction. This, however, did not highlight what ND were jointly related to predicting bias. This is important as it could inform us about where compensating errors in ND could hide. We tackle this shortcoming here by first decomposing the ND sensitivities to integral‐experiment simulations into principal components. Then we use principal component projections to predict bias via the RF and SHAP. The SHAP values and principal components are employed to reconstruct detailed SHAP values for each ND observable. We demonstrate that these extended SHAP bias predictions are more robust, less noisy, and more efficient. In addition, we show that this approach accounts for covariance in ND sensitivities and automates the identification of where compensating errors could hide in ND.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Double Quarter Wave Crab Cavity Wire Stretching Measurement at BNL

The Double Quarter Wave (DQW) crab cavity is one out of the two crab cavities within Work Package 4 of the LHC (Large Hadron Collider) Hi-Lumi Program, and the RF design of the cavity was originally supported by the US LHC Accelerator Research Program (LARP) and later the LHC Accelerator Upgrade Program (AUP) funded by the DOE High Energy Physics Office in the Office of Science. Brookhaven National Laboratory (BNL) has delivered the successful DQW crab cavity RF design, and worked actively with all. The wire stretching measurement was completed on the prototype DQW crab cavity for operation practice and calibration of the measurement system. Four locations were defined to be on the electrical center plane of the crab cavity, and survey of the wire indicated all are on the same plane. The successful measurement validated the wire stretching system built at Brookhaven National Lab. The offset of the four wire locations to the fitted plane provided the error of the measurement.

43 PARTICLE ACCELERATORS↗

Commissioning of the LCLS-II Prototype HOM Detectors with Tesla-Type Cavities at Fast

Experiments at the Fermilab Accelerator Science and Technology* (FAST) facility detected electron beam-induced high order mode (HOM) signals from Tesla superconducting cavities. This paper describes some of the signal detection hardware used in this experiment, as well as measurements of the HOM signal magnitude versus beam trajectory. These measurements were made both with a single bunch and with a train of 50 bunches at bunch charges from 400 pC/b down to 10 pC/b. The detection hardware is designed for use with the Tesla superconducting cavities of LCLS-II at SLAC** and is based on a prototype already in use at Fermilab. The HOM signal passes through a bandpass filter that is centered on several cavity dipole modes and a zero bias Schottky diode detects its magnitude. Direct comparisons were made between the FNAL chassis and the SLAC prototype for identical beam steering conditions. To support measurements with bunch charges as low as 10 pC, the SLAC detector has RF amplification between the bandpass filter and the diode detector. With this hardware, usable HOM signal measurements are obtained with a single bunch of 10 pC in cryomodule cavities as will be needed for LCLS-II.

43 PARTICLE ACCELERATORS↗