Solar-Blind Radioluminescence Imaging of Alpha Radiation in Air (Supporting Material).
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Synchrotron radiation sources are now available throughout the world. The use of hard X-ray radiation from these sources for materials science is described with emphasis on diffraction imaging for material characterization. With the availability of synchrotron radiation, real-time in situ measurements of dynamic microstructural phenomena have been started. This is a new area where traditional application of X-rays has been superseded. Examples are chosen from limited areas and are by no means exhaustive. The new emerging information will, no doubt, have great impact on materials science and engineering.
To develop a noninvasive prognostic imaging biomarker related to hypoxia to predict SABR tumor control.
The effects of ionizing radiation on three different charge coupled imagers have been investigated. Device performance was evaluated as a function of total gamma ray dose. The principal failure mechanisms have been identified for each particular device structure. The clock and bias voltages required for high total dose operation of the devices are presented.
A theoretical framework is presented for temperature imaging from long-wavelength infrared (LWIR) thermal radiation (e.g., 8–12 µm) through the end-to-end design of a metasurface-optics frontend and a computational-reconstruction backend. A new nonlinear reconstruction algorithm, “Planck regression”, is introduced to reconstruct the temperature map from a gray scale sensor image, even in the presence of severe chromatic aberration, by exploiting black body and optical physics particular to thermal imaging. This algorithm is combined with an end-to-end approach that optimizes manufacturable, single-layer metasurfaces to yield the most accurate reconstruction. The designs demonstrate high-quality, noise-robust reconstructions of arbitrary temperature maps (including completely random images) in simulations of an ultra-compact thermal-imaging device. Here, it is also shown that Planck regression is much more generalizable to arbitrary images than a straightforward neural-network reconstruction, which requires a large training set of domain-specific images.
A simplified radiation detector was designed which employs an activated continuous front surface consisting of either the diffused or barrier type of semiconducting material with a grid structure on the nonactivated side of the detector. Its form may be either a rectangular coordinate or a polar coordinate system.
Irregularities found in three crystals grown in space, in four crystals grown entirely on the ground were examined and compared. Irregularities were observed in mercuric iodide, lead tin telluride, triglycine sulfate, and gallium arsenide by high resolution synchrotron x radiation diffraction imaging. Radiation detectors made from mercuric iodide crystals grown in microgravity were reported to perform far better than conventional detectors grown from the same material under full gravity. Effort is now underway to reproduce these 'space' crystals, optimize their properties, and extend comparable superiority to other types of materials.
The imaging instrumentation on the Dynamics Explorer 1 satellite has been used to measure the intensity of the diffuse ultraviolet radiation on two great circles about the sky. It is found that the isotropic component of the diffuse ultraviolet radiation (possibly of extragalactic origin) has an intensity of 530 + or - 80 units (a unit is 1 photon per sq cm s A sr) at a wavelength of 150 nm. The Galactic component of the diffuse ultraviolet radiation has a dependence on Galactic latitude which requires strongly forward scattering particles if it is produced by dust above the Galactic plane.
The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is an imaging spectrometer that measures spatial images of the total up welling spectral radiance from 400 to 2500 nm at 10 nm spectral intervals. Quantitiative research and application objectives for surface investigations require conversion of the measured radiance to surface reflectance or surface leaving radiance. In this paper we describe a set of algorithms to estimate aerosol optical depth, atmospheric water vapor, and surface pressure height from the AVIRIS measured radiance.
The value of Cherenkov imaging as an on-patient, real-time, treatment delivery verification system was examined in a 64-patient cohort during routine radiation treatments in a single-center study.
Three dimensional radiative transfer theory was applied to computation of atmospheric effects on remotely sensed imagery. The atmospheric correction algorithm derived is used to estimate aerosol opacity.
To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.
The Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission—in partnership with the Italian Space Agency—dedicated to X-ray polarimetry in the 2–8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector, a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units at INAF-IAPS, in Italy, where a dedicated facility was setup at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.
Thermography detects mid-infrared radiation from surfaces based on the Stefan-Boltzmann law, mapping surface temperatures and potentially revealing subsurface thermal activity. Recent developments offer an alternative strategy to traditional camera-based improvements: a thermal imaging sensitizer (TIS) coating whose emissivity increases sharply with local temperature, amplifying small thermal variations into high-contrast signals. Existing TIS structures are nanofabricated solid membranes and face significant challenges in fabrication complexity. Here, in this study, we present a solution-processed, liquid form of TIS, termed temperature-adaptive radiative paint (TARP), to address these limitations. TARP offers drastically reduced fabrication costs, scalability to large areas, applicability to curved surfaces, and an extended operating temperature range, while maintaining the function of temperature amplification. Application of TARP enhances small temperature contrast by more than 3 times, substantially improving ambient thermography and enabling broader applications such as detection of structural defects and hot spots in electronic components.
Review of the results of an investigation of the magnitude of the degradation effects of radiation on the operating characteristics of camera tubes using silicon diode arrays in the space environment, and discussion of the radiation damage mechanisms concerned. The effects produced by bombardment of bare-silicon-diode arrays or vidicon tubes with 85-kV X rays, Cobalt 60 gamma rays, 1 MeV and 11 MeV electrons, 3 MeV and 142 MeV protons, and reactor neutrons are presented. Interference effects produced by radiation bombardment during operation of television tubes are investigated, and limiting fluxes of electrons and protons are given.
Radiation exposures are typically characterized by two quantities. The first is the absorbed dose, or the energy deposited per unit mass for specific types of radiation passing through specified materials. The same amount of energy deposited in material by two different types of radiation, however, can result in two different levels of risk. Because of this, for the purpose of radiation protection operations, absorbed dose is modified by a second factor intended to normalize the risk associated with a given exposure. We present here an inter-comparison of methods for this modification. First is the radiation quality factor (Q), as defined by ICRP publication 60. This quantity is related functionally to the unrestricted linear energy transfer (LET) of a given radiation, and is multiplied by the absorbed dose to derive the dose equivalent (H). The second method for modifying absorbed dose is the radiation weighting factor, also given in ICRP-60, or as modified in NCRP report 115. To implement the weighting factor, the absorbed dose resulting from incidence of a particular radiation is multiplied by a factor assigned to that type of radiation, giving the equivalent dose. We compare calculations done based on identical fields of radiation representative of that encountered by the MIR space station, applying each of these two methods. c2002 COSPAR. Published by Elsevier Science Ltd. All rights reserved.
Systems and methods of x-ray backscatter radiography are provided. A single-sided, non-destructive imaging technique utilizing x-ray radiation to image subsurface features is disclosed, capable of scanning a region using a fan beam aperture and gathering data using rotational motion.