Inspection of composites using a computer-based real-time radiographic facility

A radiographic inspection facility was developed at the NASA Lewis Research Center. The facility uses a digital computer to provide enhanced images in near real-time. Some capabilities of the facility are demonstrated in the inspection of a fan frame ring for an experimental aircraft gas turbine. The ring was fabricated from a carbon-fiber-reinforced epoxy composite material. Inspection procedures were evaluated, and comparisons were made with an ultrasonic C-scan and conventional film X-ray.

Roberts, E., Jr.↗

Radiographic applications of spatial frequency multiplexing

The application of spacial frequency encoding techniques which allow different regions of the X-ray spectrum to be encoded on conventional radiographs was studied. Clinical considerations were reviewed, as were experimental studies involving the encoding and decoding of X-ray images at different energies and the subsequent processing of the data to produce images of specific materials in the body.

Macovski, A.↗

Radiographic detection of cracks

Procedure utilizing x-ray radiography techniques can detect material cracks as small as 20% of material thickness, with 90% probability and 95% confidence if proper imaging procedures and criteria for selecting qualified inspectors are followed.

Sugg, F. E.↗

A Markov Random Field Model for Texture-based Segmentation of Small Cracks in Thin InconelTubes

Markov random fields have been used for image segmentation since their introduction in the1980s. This work applies a method from Principal Component Thermography to enhance thecontrast in damage regions in 3D images derived from X-ray computed tomography (CT)inspections. The developed method is applied to sizing of small cracks in thin Inconel tubes designed as probability of detection (POD) samples for radiographic inspection.Misclassification errors arising from artifacts due to beam-hardening are reduced by fitting the boundary of the segmented damage region with the arc of an ellipse. Results are comparedagainst those obtained through manual inspection.

Image segmentation↗

Advanced Ultrasonic Diagnosis of Extremity Trauma: The Faster Exam

Ultrasound is of prO)len accuracy in abdominal and thoracic trauma and may be useful to diagnose extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity , ultrasound performed by trained, non-physician personnel in patients with extremity trauma, to simulate remote aerospace or military applications . Methods: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel with a portable ultrasound device using a 10-5 MHz linear probe, Images were video-recorded for later analysis against radiography by Fisher's exact test. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity, injury in 94% of patients with no false positive exams; accuracy was greater in mid-shaft locations and least in the metacarpa/metatarsals. Soft tissue/tendon injury was readily visualized . Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Blinded verification of the utility of ultrasound in patients with extremity injury should be done to determine if Extremity and Respiratory evaluation should be added to the FAST examination (the FASTER exam) and verify the technique in remote locations such as military and aerospace applications.

Dulchavsky, S. A.↗

Positioning X-Ray Film By Balloon

Film rolled around deflated balloon before being inserted in duct. Clamped at end of segmented flexible cable and fed with balloon into duct to predetermined point where inspection made, as indicated by length of cable paid out. Inflated balloon holds x-ray film against inside wall of duct for radiographic inspection. Ensures film positioned in contact with welded joint far along duct from opening through which inserted, so clear x-ray image of joint obtained.

Windbiel, Frederich↗

Nondestructive Testing As a Tool in the Space Shuttle Columbia Accident Investigation

Nondestructive testing (NDT) played a crucial role in determining the Columbia tragedy's cause. Over 84,000 pieces of debris were recovered; hundreds were subsequently subjected to NDT and materials analysis. Visual NDT of the debris revealed localized areas of damage such as erosion, excessive heating, knife edging and mechanical damage. Three-dimensional reconstructions were made of the left wing leading edge, utilizing a tripod-mounted laser scanning head and focused laser beam, and an advanced topometric optical scanner (ATOS) with digital white light to scan complex-shaped debris, producing monochrome 3-D models. Texture mapping provided a means to capture true colors of the debris and superimpose them on the scanned images. Uniform deposits were found over large portions of debris, obscuring underlying materials. To determine what was beneath, inverse radiography was enlisted. The radiographs guided investigators to where samples should be taken. To ascertain compositions, these samples were subjected to analytical testing, including energy dispersive X-ray spectroscopy and electron microprobe analysis. This combination of visual evidence, radiography, virtual reconstruction, and materials analysis allowed the forensic scientists to verify that a breach occurred in the leading edge of the left wing, the path the plasma followed, and the sequence of events that led to the loss.

McDanels, Steve↗

Automated Registration of Multi-Mode Nondestructive Evaluation Data

Registration techniques play a central role in applications of image processing to computer vision, medical imaging, and automatic target tracking. Feature-based techniques such as scale-invariant feature transform (SIFT) and speeded up robust features (SURF) are commonly used to register images derived from a single modality. However, SIFT and SURF struggle to register images from different modalities because the features tend to manifest rather differently and at sometimes very different length-scales. The most successful methods that have been developed to register multi-modal data use information-theoretic approaches. These methods play a key part in nondestructive evaluation scenarios where data that is collected by sensors of different modalities must be registered to be fused. In this paper, automated registration based on normalized mutual information is applied to align data derived from ultrasonic and radiographic inspections of (i) additively manufactured titanium alloy test coupons, and (ii) thin, lithium metal pouch-cell batteries. The quality of the registration is quantified in terms of computational resources and spatial accuracy. In the first case the X-ray computed tomography (XCT) data is captured on a region corresponding to a small subset of the ultrasonic data, while in the case of the lithium batteries the digital radiography (DR) captures a larger region of interest than the ultrasonic data. In both cases the radiographic data resolution is much higher than for ultrasound, but interestingly, in both cases the accuracy of the registration is approximately equal to two-to-three-pixel lengths in the ultrasonic images.

Nondestructive Evaluation↗

Real-time radiographic inspection facility

A real time radiographic inspection facility has been developed for nondestructive evaluation applications. It consists of an X-ray source, an X-ray sensitive television imaging system, an electronic analog image processing system, and a digital image processing system. The digital image processing system is composed of a computer with the necessary software to drive the overall facility. Descriptions are given of the design strategy, the facility's components, and its current capabilities.

Roberts, E., Jr.↗

Neutron radiographic viewing system

Neutron radiographic viewing system consisting of camera head and control processor is developed for use in nondestructive testing applications. Camera head consists of neutron-sensitive image intensifier system, power supply, and SEC vidicon camera head. Both systems, with their optics, are housed on test mount.

Leysath, W.↗

Development of optimized techniques and requirements for computer enhancement of structural weld radiographs. Volume 1: Technical report

A hardware and software specification covering requirements for the computer enhancement of structural weld radiographs was considered. Three scanning systems were used to digitize more than 15 weld radiographs. The performance of these systems was evaluated by determining modulation transfer functions and noise characteristics. Enhancement techniques were developed and applied to the digitized radiographs. The scanning parameters of spot size and spacing and film density were studied to optimize the information content of the digital representation of the image.

Adams, J. R.↗

Accelerated Aging Experiments for Prognostics of Damage Growth in Composite Materials

Composite structures are gaining importance for use in the aerospace industry. Compared to metallic structures their behavior is less well understood. This lack of understanding may pose constraints on their use. One possible way to deal with some of the risks associated with potential failure is to perform in-situ monitoring to detect precursors of failures. Prognostic algorithms can be used to predict impending failures. They require large amounts of training data to build and tune damage model for making useful predictions. One of the key aspects is to get confirmatory feedback from data as damage progresses. These kinds of data are rarely available from actual systems. The next possible resource to collect such data is an accelerated aging platform. To that end this paper describes a fatigue cycling experiment with the goal to stress carbon-carbon composite coupons with various layups. Piezoelectric disc sensors were used to periodically interrogate the system. Analysis showed distinct differences in the signatures of growing failures between data collected at conditions. Periodic X-radiographs were taken to assess the damage ground truth. Results after signal processing showed clear trends of damage growth that were correlated to damage assessed from the X-ray images.

composites↗

Advanced imaging of the macrostructure and microstructure of bone

Noninvasive and/or nondestructive techniques are capable of providing more macro- or microstructural information about bone than standard bone densitometry. Although the latter provides important information about osteoporotic fracture risk, numerous studies indicate that bone strength is only partially explained by bone mineral density. Quantitative assessment of macro- and microstructural features may improve our ability to estimate bone strength. The methods available for quantitatively assessing macrostructure include (besides conventional radiographs) quantitative computed tomography (QCT) and volumetric quantitative computed tomography (vQCT). Methods for assessing microstructure of trabecular bone noninvasively and/or nondestructively include high-resolution computed tomography (hrCT), micro-computed tomography (muCT), high-resolution magnetic resonance (hrMR), and micromagnetic resonance (muMR). vQCT, hrCT and hrMR are generally applicable in vivo; muCT and muMR are principally applicable in vitro. Although considerable progress has been made in the noninvasive and/or nondestructive imaging of the macro- and microstructure of bone, considerable challenges and dilemmas remain. From a technical perspective, the balance between spatial resolution versus sampling size, or between signal-to-noise versus radiation dose or acquisition time, needs further consideration, as do the trade-offs between the complexity and expense of equipment and the availability and accessibility of the methods. The relative merits of in vitro imaging and its ultrahigh resolution but invasiveness versus those of in vivo imaging and its modest resolution but noninvasiveness also deserve careful attention. From a clinical perspective, the challenges for bone imaging include balancing the relative advantages of simple bone densitometry against the more complex architectural features of bone or, similarly, the deeper research requirements against the broader clinical needs. The considerable potential biological differences between the peripheral appendicular skeleton and the central axial skeleton have to be addressed further. Finally, the relative merits of these sophisticated imaging techniques have to be weighed with respect to their applications as diagnostic procedures requiring high accuracy or reliability on one hand and their monitoring applications requiring high precision or reproducibility on the other. Copyright 2000 S. Karger AG, Basel.

NASA Discipline Musculoskeletal↗

Engine materials characterization and damage monitoring by using x ray technologies

X ray attenuation measurement systems that are capable of characterizing density variations in monolithic ceramics and damage due to processing and/or mechanical testing in ceramic and intermetallic matrix composites are developed and applied. Noninvasive monitoring of damage accumulation and failure sequences in ceramic matrix composites is used during room-temperature tensile testing. This work resulted in the development of a point-scan digital radiography system and an in situ x ray material testing system. The former is used to characterize silicon carbide and silicon nitride specimens, and the latter is used to image the failure behavior of silicon-carbide-fiber-reinforced, reaction-bonded silicon nitride matrix composites. State-of-the-art x ray computed tomography is investigated to determine its capabilities and limitations in characterizing density variations of subscale engine components (e.g., a silicon carbide rotor, a silicon nitride blade, and a silicon-carbide-fiber-reinforced beta titanium matrix rod, rotor, and ring). Microfocus radiography, conventional radiography, scanning acoustic microscopy, and metallography are used to substantiate the x ray computed tomography findings. Point-scan digital radiography is a viable technique for characterizing density variations in monolithic ceramic specimens. But it is very limited and time consuming in characterizing ceramic matrix composites. Precise x ray attenuation measurements, reflecting minute density variations, are achieved by photon counting and by using microcollimators at the source and the detector. X ray computed tomography is found to be a unique x ray attenuation measurement technique capable of providing cross-sectional spatial density information in monolithic ceramics and metal matrix composites. X ray computed tomography is proven to accelerate generic composite component development. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results from one-, three-, five-, and eight-ply ceramic composite specimens show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber-matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. In situ film radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction-bonded silicon nitride matrix. It is concluded that pretest, in situ, and post-test x ray imaging can provide greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗

X ray attenuation measurements for high-temperature materials characterization and in-situ monitoring of damage accumulation

The scope of this dissertation is to develop and apply x ray attenuation measurement systems that are capable of: (1) characterizing density variations in high-temperature materials, e.g., monolithic ceramics, ceramic and intermetallic matrix composites, and (2) noninvasively monitoring damage accumulation and failure sequences in ceramic matrix composites under room temperature tensile testing. This dissertation results in the development of: (1) a point scan digital radiography system, and (2) an in-situ x ray material testing system. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. Further in-situ radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction bonded silicon nitride matrix. It is concluded that pretest, in-situ, and post test x ray imaging can provide for greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗

X-Ray Radiographic Observation of Directional Solidification Under Microgravity: XRMON-GF Experiments on MASER12 Sounding Rocket Mission

The European Space Agency (ESA) - Microgravity Application Promotion (MAP) programme entitled XRMON (In situ X-Ray MONitoring of advanced metallurgical processes under microgravity and terrestrial conditions) aims to develop and perform in situ X-ray radiography observations of metallurgical processes in microgravity and terrestrial environments. The use of X-ray imaging methods makes it possible to study alloy solidification processes with spatio-temporal resolutions at the scales of relevance for microstructure formation. XRMON has been selected for MASER 12 sounding rocket experiment, scheduled in autumn 2011. Although the microgravity duration is typically six minutes, this short time is sufficient to investigate a solidification experiment with X-ray radiography. This communication will report on the preliminary results obtained with the experimental set-up developed by SSC (Swedish Space Corporation). Presented results dealing with directional solidification of Al-Cu confirm the great interest of performing in situ characterization to analyse dynamical phenomena during solidification processes.

Reinhart, G.↗

Ultraviolet images of M101 - Observations of dust and inferences on the metallicity

Since extreme Population I dominates three rocketborne telescope UV images of the Sc I galaxy NGC 5457, the delineation of the spiral structure is sharper than that of ground photographs. The UV pictures, in which the H II regions appear as reflection nebulae and illumine the nearby dust, reveal faint arms which, although correlated with the 21 cm H I radiograph, are only marginally detectable on deep visual photographs. The surface brightness of the arms is explainable in terms of UV light scattering off dust from hot stars and bright H II regions, in which case the dust would have extinction properties and a dust-to-gas ratio similar to that in the solar neighborhood and would in addition suggest that the NGC 5457 outer arm metal content is similar to that of the galaxy.

Stecher, T. P.↗

Inspecting Pipe Radiographically Through Asbestos Insulation

Welds between sections of insulated steampipe located and inspected radiographically. Unless need to repair defective weld, one avoids cost, time, and hazard of removing asbestos insulation. Enables inspectors to locate and evaluate nondestructively any weld in pipe system, without shutting down steam. Hidden weld joints first located by use of low-power fluoroscope, moved along pipe while technician observes fluoroscopic image. Low-energy x rays from fluoroscope penetrate insulation but not pipe. Weld bead appears in silhouette on fluoroscope screen. Technician then accurately marks weld sites on insulation for later inspection.

Gianettino, David P.↗