Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reactivity Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluation of Curtailment Associated with PV System Design Considerations

Distributed photovoltaic (PV) systems equipped with advanced inverters can control real and reactive power output based on grid and atmospheric conditions. The Volt-Var control method allows inverters to regulate local grid voltages by producing or consuming reactive power. Based on their power ratings, the inverters may need to curtail real power to meet the reactive power requirements, which decreases their total energy production. To evaluate the expected curtailment associated with Volt-Var control, yearlong quasi-static time-series (QSTS) simulations were conducted on a realistic distribution feeder under a variety of PV system design considerations. Overall, this paper found that the amount of curtailed energy is low (<; 0.55%) compared to the total PV energy production in a year but is affected by several PV system design considerations.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Electrical Validation Testing for ORPC MHK Generator, Modification 6: ORPC SBV for MHK Generator System (CRADA Final Report)

For the U.S. Department of Energy’s (DOE) 2016 Small Business Voucher for Marine and Hydrokinetic (MHK) System, Second Round 2016, ORPC intends to work with the National Renewable Energy Laboratory (NREL) to perform dynamometer testing of the MHK generator systems and its associated controls and inverters. ORPC will provide the generator, variable frequency drives (VFD), controls, and inverter for this testing. NREL will utilize the NREL Energy Systems Integration Facility (ESIF) and dynamometer facilities at the National Wind Technology Center (NWTC) for this work. Modification 6: Additionally, NREL will conduct a feasibility study for implementing passive DC rectification at the turbine.

17 WIND ENERGY↗

Optimal Energy Dispatch of Distributed PVs for the Next Generation of Distribution Management Systems

Advanced Distribution Management Systems (ADMS) are being widely adopted by electric utilities for managing and optimizing the operations of their distribution systems. Distributed photovoltaic (DPV) systems with smart inverters can be controlled to adjust active power and reactive power outputs, and they are envisioned to become a part of (centrally or distributed) controllable assets managed by the ADMS for optimizing grid operations. This paper proposes an optimal energy dispatch strategy controlling DPV systems for regulating distribution voltages and achieving conservation voltage reduction. A convex optimization model is proposed with the use of linearized power flow, and the gradient projection algorithm is used to solve the optimal active power and reactive power outputs of smart inverters. The proposed optimal energy dispatch is implemented using an open-source ADMS platform, and simulation results have demonstrated the effectiveness of the proposed approach on improving distribution grid operations.

42 ENGINEERING↗

A Comparison of Homogeneous and Heterogeneous Uranium Metal-Water Systems using Calculated and Experimental Critical Data

Heterogeneous effects of fissile units latticed in water has been documented in several forms in commonly referenced handbooks and guides. Many of these documents provide guidance for when heterogeneous systems are more reactive than their homogenous counterparts if controlling fissile mass or volume. This information provides insight into when heterogeneity should be considered for conservatism, however this information is not always displayed in a manner that is comparable to commonly referenced data, such as critical curves based on spherical systems. This paper aims to provide a juxtaposition of homogenous and heterogeneous uranium metal-water systems using both experimental and calculated critical data displayed in the format of commonly referenced critical curves. This format allows for easy comparison between the two systems against parameters that are often considered for single unit analysis such as: uranium density, fissile mass, system volume, and total system mass (fissile mass plus moderator mass). Calculated critical spherical systems provide an equal comparison between latticed geometry types as the latticed array can be cut off or restricted in the same manner in each series of models, which is not true for experimental values. Additionally, enrichment of the latticed units can be made uniform in the calculated systems, which is also difficult to achieve when referencing experimental data of varying latticed geometries. A comparison of calculated critical values and available experimental values is provided to show how these parameters can impact the critical spherical system result.

36 MATERIALS SCIENCE↗

A Comparison of Homogeneous and Heterogeneous Uranium Metal-Water Systems using Calculated and Experimental Critical Data

Heterogeneous effects of fissile units latticed in water has been documented in several forms in commonly referenced handbooks and guides. Many of these documents provide guidance for when heterogeneous systems are more reactive than their homogenous counterparts if controlling fissile mass or volume. This information provides insight into when heterogeneity should be considered for conservatism, however this information is not always displayed in a manner that is comparable to commonly referenced data, such as critical curves based on spherical systems. This paper aims to provide a juxtaposition of homogenous and heterogeneous uranium metal-water systems using both experimental and calculated critical data displayed in the format of commonly referenced critical curves. This format allows for easy comparison between the two systems against parameters that are often considered for single unit analysis such as: uranium density, fissile mass, system volume, and total system mass (fissile mass plus moderator mass). Calculated critical spherical systems provide an equal comparison between latticed geometry types as the latticed array can be physically cut off or restricted in the same manner in each series of models, which is not true for experimental values. Additionally, enrichment of the latticed units can be made uniform in the calculated systems, which is difficult to achieve when referencing experimental data of varying latticed geometries. A comparison of calculated critical values and available experimental values is provided to show how these parameters can impact the critical spherical system result.

36 MATERIALS SCIENCE↗

Examination of a Methane/Diesel RCCI Engine Using Pele: Preprint

Multi-fuel, advanced injection strategies have become increasingly promising as a strategy to mitigate the emissions generated from internal combustion engines. By carefully controlling the combustion phasing in-cylinder, these new multi-pulse, multi-fuel injection strategies are able to burn in the low-temperature combustion regime where both NOx and soot are not readily produced, reducing the need for extensive exhaust gas recirculation systems. In this study, we examine a reactivity-controlled compression ignition (RCCI) strategy that uses an early pre-filled methane-air mixture with low turbulence background as the low-reactivity fuel and a direct injection of four discrete dodecane jets as a surrogate for the high-reactivity diesel fuel. We use the Pele software suite, a highly optimized, exascale-ready, adaptive mesh refinement codebase to perform high-resolution numerical simulations of a scaled down, single cylinder from the RCCI engine. Here, we resolve the ignition kernels down to micrometer scales and present several statistical quantities evaluating the development of the flow and detailing the onset of ignition and subsequent flame development. Particular attention is paid to the conditions surrounding the onset of the first ignition kernels and discussing what led to the development of those conditions.

CFD↗

Genome-wide identification of novel flagellar motility genes in Pseudomonas syringae pv. tomato DC3000

Pseudomonas syringaepv.tomatoDC3000 (PstDC3000) is a plant pathogenic bacterium that possesses complicated motility regulation pathways including a typical chemotaxis system. A significant portion of our understanding about the genes functioning inPstDC3000 motility is based on comparison to other bacteria. This leaves uncertainty about whether gene functions are conserved, especially since specific regulatory modules can have opposite functions in sets ofPseudomonas. In this study, we used a competitive selection to enrich for mutants with altered swimming motility and used random barcode transposon-site sequencing (RB-TnSeq) to identify genes with significant roles in swimming motility. Besides many of the known or predicted chemotaxis and motility genes, our method identified PSPTO_0406 (dipA), PSPTO_1042 (chrR) and PSPTO_4229 (hypothetical protein) as novel motility regulators. PSPTO_0406 is a homolog ofdipA, a known cyclic di-GMP degrading enzyme inP. aeruginosa. PSPTO_1042 is part of an extracytoplasmic sensing system that controls gene expression in response to reactive oxygen species, suggesting that PSPTO_1042 may function as part of a mechanism that enablesPstDC3000 to alter motility when encountering oxidative stressors. PSPTO_4229 encodes a protein containing an HD-related output domain (HDOD), but with no previously identified functions. We found that deletion and overexpression of PSPTO_4229 both reduce swimming motility, suggesting that its function is sensitive to expression level. We used the overexpression phenotype to screen for nonsense and missense mutants of PSPTO_4229 that no longer reduce swimming motility and found a pair of conserved arginine residues that are necessary for motility suppression. Together these results provide a global perspective on regulatory and structural genes controlling flagellar motility inPstDC3000.

Microbiology↗

Performance constraints and compensation for teleoperation with delay

A classical control perspective is used to characterize performance constraints and evaluate compensation techniques for teleoperation with delay. Use of control concepts such as open and closed loop performance, stability, and bandwidth yield insight to the delay problem. Teleoperator performance constraints are viewed as an open loop time delay lag and as a delay-induced closed loop bandwidth constraint. These constraints are illustrated with a simple analytical tracking example which is corroborated by a real time, 'man-in-the-loop' tracking experiment. The experiment also provides insight to those controller characteristics which are unique to a human operator. Predictive displays and feedforward commands are shown to provide open loop compensation for delay lag. Low pass filtering of telemetry or feedback signals is interpreted as closed loop compensation used to maintain a sufficiently low bandwidth for stability. A new closed loop compensation approach is proposed that uses a reactive (or force feedback) hand controller to restrict system bandwidth by impeding operator inputs.

Mclaughlin, J. S.↗

The NASA/Army Autonomous Rotorcraft Project

An overview of the NASA Ames Research Center Autonomous Rotorcraft Project (ARP) is presented. The project brings together several technologies to address NASA and US Army autonomous vehicle needs, including a reactive planner for mission planning and execution, control system design incorporating a detailed understanding of the platform dynamics, and health monitoring and diagnostics. A candidate reconnaissance and surveillance mission is described. The autonomous agent architecture and its application to the candidate mission are presented. Details of the vehicle hardware and software development are provided.

Whalley, M.↗

Calcium‐Ion Binding Mediates the Reversible Interconversion of Cis and Trans Peroxido Dicopper Cores

Abstract Coupled dinuclear copper oxygen cores (Cu 2 O 2 ) featured in type III copper proteins (hemocyanin, tyrosinase, catechol oxidase) are vital for O 2 transport and substrate oxidation in many organisms. μ ‐1,2‐ cis peroxido dicopper cores ( C P ) have been proposed as key structures in the early stages of O 2 binding in these proteins; their reversible isomerization to other Cu 2 O 2 cores are directly relevant to enzyme function. Despite the relevance of such species to type III copper proteins and the broader interest in the properties and reactivity of bimetallic C P cores in biological and synthetic systems, the properties and reactivity of C P Cu 2 O 2 species remain largely unexplored. Herein, we report the reversible interconversion of μ ‐1,2‐ trans peroxido ( T P ) and C P dicopper cores. Ca II mediates this process by reversible binding at the Cu 2 O 2 core, highlighting the unique capability for metal‐ion binding events to stabilize novel reactive fragments and control O 2 activation in biomimetic systems.

Vargo, Natasha P.↗

Calcium-Ion Binding Mediates the Reversible Interconversion of Cis and Trans Peroxido Dicopper Cores

Coupled dinuclear copper oxygen cores (Cu 2 O 2 ) featured in type III copper proteins (hemocyanin, tyrosinase, catechol oxidase) are vital for O 2 transport and substrate oxidation in many organisms. μ-1,2-cis peroxido dicopper cores ( C P) have been proposed as key structures in the early stages of O 2 binding in these proteins; their reversible isomerization to other Cu 2 O 2 cores are directly relevant to enzyme function. Furthermore, despite the relevance of such species to type III copper proteins and the broader interest in the properties and reactivity of bimetallic C P cores in biological and synthetic systems, the properties and reactivity of C P Cu 2 O 2 species remain largely unexplored. Herein, we report the reversible interconversion of μ-1,2-trans peroxido ( T P) and C P dicopper cores. Ca II mediates this process by reversible binding at the Cu 2 O 2 core, highlighting the unique capability for metal-ion binding events to stabilize novel reactive fragments and control O 2 activation in biomimetic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty quantification and sensitivity analysis of a nuclear thermal propulsion reactor startup sequence

The research presented in this article describes progress in applying stochastic methods, uncertainty quantification, parametric studies, and variance-based sensitivity analysis (also known as Sobol sensitivity analysis) to a full-core model of a nuclear thermal propulsion (NTP) system simulated via the radiation transport code Griffin to simulate neutronics. Our goal is to develop a reduced-order (surrogate) model that can be rapidly sampled with perturbations to multiple input parameters. In this NTP system, reactivity and power feedback affect the rotation of control drums (CDs), which is itself controlled by a hybrid proportional-integral-derivative (PID) controller actuated by the power demand and reactivity feedback from the numerical model. This model uses reactor kinetic feedback (mean generation time [Λ] and effective delayed neutron fraction [ β eff ] from a transient Griffin simulation executed via Griffin’s improved quasi-static solver to provide the kinetic parameters) as inputs to functions that control the CD rotation angle. By investigating numerous stochastic approaches, we developed a dual-purpose surrogate model of the NTP system, using polynomial regression in the Multiphysics Object-Oriented Simulation Environment (MOOSE) Stochastic Tools Module (STM). The trained model can be rapidly sampled while simultaneously perturbing various input parameters, such as coefficients on the PID control or temperature (directly affecting the neutron cross section). The surrogate model delivers accurate (within 5%) results at speeds orders of magnitude faster (minutes, not days of computational time) than the base model. Once the surrogate model has been trained, distributions of the uncertain parameters can be changed at will to investigate the effects of perturbing multiple inputs as well as the effects of these inputs on the model output. For example, coefficients used in the PID control system may vary due to some type of physical interference, or uncertainty may exist in the temperature of the neutron cross sections in various regions of the reactor. A distribution can be placed on these parameters, and operational boundaries can be determined. The goal of this work is to support development of an advanced control system for operating CDs in a functioning NTP system. This work is a scoping study of the MOOSE STM.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Development of a new control rod drive mechanism design for the ISU AGN-201M reactor

The Aerojet General Nucleonics (AGN) model 201-Modified, known as the AGN-201M reactor, plays an essential role in the educational and research activities at Idaho State University (ISU). The ISU AGN-201M's original Control Rod Drive Mechanism (CRDM) has been in operation for more than fifty years with no large-scale redesigns. The CRDM is required to eject the fuel rods within one second during a SCRAM event (also known as a 'reactor trip') and adjust the control rods' insertion speed, and keeps the rod insertion sequence correct. The existing control rod drive mechanisms meet these criteria but experience a few concerns due to aging. Concerns include complex maintenance and costly repairs for old electromechanical components, rod position feedback errors, and the impediment of the plate during a SCRAM due to binding of the lead screws of the existing mechanism. During a binding event, the drive mechanism becomes locked, preventing the control rod's magnetic plate from moving in or out under the reactor's normal and emergency operating conditions. Although, the binding has no effect on the ability of the rod to exit the core during the SCRAM. To counteract the concerns and issues with the current CRDM, a new design has been proposed using newer components and a simplified design. The new design utilizes more advanced electric and mechanical components that are commercially available. The new CRDM system is divided into four main aspects: (1) control rod movement design (motor, lead screw, guide rods), (2) control rod ejection (springs, electromagnet), (3) control rod position and feedback (position transducer, microswitches), and (4) material selection and structural analysis. The new design aims to reduce the overall complexity and probability of failure to improve the reactor's overall reliability. With proper material selection and improved structural design, the new drives are lighter with little to no change in structural integrity. The new control rod drive mechanism eliminates binding scenarios by using a single lead screw and implementing additional guide rods. An advanced linear position sensor and microswitches replace the existing and aging synchro system for accurate rod position feedback resulting in better reactivity control. The new design meets the reactor's operational limits by having an average reactivity insertion of 0.065% Δk/k per second, which corresponds to a total control rod insertion time of 19.23 s, while the control rod's ejection time remains less than one second during a SCRAM event. The new design ensures the reactor's long-term viability for educational and research activities by increasing the reliability and safety of operation for years to come.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY20 SAM Code Developments and Validations for Transient Safety Analysis of Advanced non-LWRs

The System Analysis Module (SAM) is under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. This report summarizes major progress in SAM code development, capability enhancements, demonstration, and validation to support transient safety analysis of advanced non-LWRs. Rapid developments continued in fiscal year 2020 (FY20) to support various needs of the advanced reactor community, especially the NRC and industry on the licensing safety analysis of advanced reactor designs. Significant code changes were made to provide various capability enhancements, bug fixes, and user friendliness improvements. Major code updates are summarized in Section 1, while four important enhancements are detailed in Sections 2-5, including a multi-dimension flow model; reactivity feedback and decay heat models; control and trip system modeling, and additional fluid and solid thermophysical property models. Code validation activities in FY20 include using test data from the Fast Flux Test Facility (FFTF), the High Temperature Test Facility (HTTF), and several separate effects test facilities for pebble-bed modeling.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗