Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of Standardized Lunar Regolith Simulant Materials

Lunar exploration requires studies using standardized testing procedures. Previous lunar simulants focused on physical aspects of the lunar regolith. Renewed lunar exploration requires standardized lunar regolith simulant (SLRS) materials that simulate the physical, chemical, and mineralogical properties of the regolith [l]. A root simulant models an end-member, and a derivative is formed by addition of material [2]. The 2005 Workshop recommended a low-Ti mare basalt and a high-Ca highland anorthosite set of roots. Derivatives involve addition of ilmenite and glassy agglutinates [3]. An ideal SLRS material is homogeneous. Geochemical standards are finely-ground to reduce chemical variability, but lunar simulants have a grain size variation and mineralogy that must match the lunar regolith. The simulant homogeneity is monitored using major, minor, and trace element data of progressively smaller samples compared to bulk material. Both chemical and geotechnical properties depend on the contrast from grain to grain. The variability of simulant material is an inherent property that must be taken into account. Simulant production requires monitoring of adherence to simulant requirements and homogeneity during production. Quality control establishes a traceability to a master set of reference standards.

Carpenter, P.↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗

Deep space communication.

Time reference standard, two-way doppler, ground and spacecraft antennas, circuit noise reduction and spacecraft acquisition considered in signal transmission from deep space

SPACE COMMUNICATION↗

Absolute low-pressure calibration system

McLeod gage is used as the primary reference standard in a system used for absolute calibration of vacuum gages in the very low pressure range. The system involves steady-state flow of a gas through a cascade of differentially pumped chambers or stages connected by precisely defined orifices.

Roehrig, J. R.↗

Manufacture and quality control of interconnecting wire harnesses

Four-volume series of documents has been prepared as standard reference. Each volume may be used separately and covers wire and cable preparation as well as harness fabrication and installation. Series should be useful addition to libraries of manufactures of electrical and electronic equipment.

Source record↗

Improved noise-adding radiometer for microwave receivers

Use of input switch and noise reference standard is avoided by using noise-adding technique. Excess noise from solid state noise-diode is coupled into receiver through directional coupler and square-wave modulated at low rate. High sensitivity receivers for radioastronomy applications are utilized with greater confidence in stability of radiometer.

Batelaan, P. D.↗

Design and performance characteristics of the Vertical Temperature Profile Radiometer /VTPR/ for atmospheric temperature soundings.

Description of the design and operation of a radiometer which derives atmospheric temperature profiles on the basis of spectral measurements in eight optical filter channels. The radiometer achieves its eight-channel capability by sequentially viewing the eight optical filters mounted in a rotating filter wheel, with a single IR detector and electronic amplification channel processing the signal for all the filters. The advantages and disadvantages of this sequential approach as compared to eight 'parallel' radiometric channels are discussed. The proposed radiometer provides a relative calibration accuracy between seven out of the eight channels of better than 0.1% rms of the full dynamic range. The absolute accuracy achievable between in-flight calibrations of six minutes, or between two-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the in-flight calibration source of the instrument and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

Calibration of platinum resistance thermometers.

Results of five years experience in calibrating about 1000 commercial platinum resistance thermometers (PRT) are reported. These PRT were relatively small and rugged, with ice-point resistances from 200 to 5000 ohms. Calibrations normalized in terms of resistance-difference ratios (Cragoe Z function) were found to be remarkably uniform for five of six different types of PRT tested, and to agree very closely with normalized calibrations of the primary reference standard type PRT. The Z function normalization cancels residual resistances which are not temperature dependent and simplifies interpolation between calibration points when the quality of a given type of PRT has been established in terms of uniform values of the Z function. Measurements at five or six well spaced base-point temperatures with Z interpolation will suffice to calibrate a PRT accurately from 4 to 900 K.

Sinclair, D. H.↗

Thermometric convection coefficients for rocket meteorological sensors (tables)

Values of the convective heat transfer coefficient h, and the recovery factor r, for miniature beads, fine wires, and films in rarefied air flow are shown. Data provide a standard reference for computing consistent operational corrections to rocket meteorological measurements, and for predicting the performance of existing and proposed sensor systems.

Staffanson, F. L.↗

Holographic and ultrasonic detection of bond flaws in aluminum panels reinforced with boron-epoxy

An experimental investigation was made of the application of holographic interferometry to the nondestructive detection of unbonded areas (flaws) in bonded panels. Flaw detection results were compared with results obtained with an ultrasonic flaw detector. Holography, with panel deformation accomplished by a reduction in ambient pressure, is less sensitive for flaws beneath 5 and 10 plies of boron-epoxy than the ultrasonic method, though it does have its operational advantages. A process for the manufacture of bonded panels which incorporate known unbonded areas was also developed. The unbonded areas were formed without the use of foreign materials, which makes the method suitable for the construction of reference standards for bonded panels whenever needed for the proper setup of ultrasonic flaw-detection instruments.

Platt, R. J., Jr.↗

Design and performance characteristics of the vertical temperature profile radiometer /VTPR/ for atmospheric temperature soundings

Various design characteristics and performance achievements of the vertical temperature profile radiometer (VTPR) are discussed. It is shown that the VTPR provides a relative calibration accuracy of better than 0.1% rms of the full dynamic range and has been operating successfully in space on the ITOS spacecraft for more than eleven months. The absolute accuracy achievable between in-flight calibrations of 6 minutes, or between 2-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the VTPR in-flight calibration source and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

NASA Lyndon B. Johnson Space Center's Metrology Program

Since the establishment in 1962 of the NASA-JSC Metrology Program, the Reference Standards Laboratory has successfully accomplished its goal and objectives. An on-going laboratory surveillance program, established for insuring a continuing validation of the measurements required at the center, is shown to remain at the forefront of modern technology through its involvement in activities such as the NBS sponsored Measurement Assurance Programs and the utilization of an Automatic Calibration System.

Suraci, J. M.↗

Content of lithium, beryllium, boron, and titanium, and the isotopic composition of lithium, boron, and magnesium in Luna 16 regolith sample

The abundance of the following elements in the L 16-19 No. 118 regolith sample, zone V was determined by isotopic dilution using a mass spectrometer equipped with a scattering ion source: Li -- 9.8, Be -- 1.2, Be -- 2.6, and Ti -- 1.92 percent. For comparison, these same elements were measured in samples of surface material returned by Apollo 11, Apollo 12, and Apollo 14, and in the terrestrial reference standard diabase W-1. The content of Li, Be, and B in the Luna 16 sample is nearly the same as in the Apollo 11 surface material. The surface material returned by Apollo 12 and Apollo 14 contains two to four times more of these elements. However, the abundance ratios of Li, Be, and B are remarkably similar in the surface materials from the four different lunar regions. With respect to basaltic achondrites and especially with respect to chondrites, the lunar basalts are enriched in Li, Be, and B up to 100 times.

Eugster, O.↗

Development of a laser fluorosensor for airborne surveying of the aquatic environment

A field based laser fluorosensor, employing a pulsed nitrogen laser and telescope photomultiplier detector system, has been successfully tested at night from a cliff top site overlooking Lake Ontario providing target ranges greater than 274 meters. Remotely sensed spectra and amplitude changes in the fluorescence emission of natural waters have shown potential as a water quality indicator. In this connection, a convenient internal reference standard with which to gauge the amplitude of the fluorescence signal is realized in the form of the concurrent water Raman emission. Remote measurements of oil fluorescence emission spectra suggest that airborne laser fluorosensors are capable of detecting and characterizing the oil in a given slick and that environmental aging of these slicks does not significantly alter their fluorescence emission signature.

Bristow, M. P. F.↗

Spectroradiometric calibration techniques in the far ultraviolet - A stable emission source for the Lyman bands of molecular hydrogen

The problems associated with making accurate spectroradiometric measurements in the far UV region are sketched briefly. The equipment and methods that were developed for providing absolute sensitivity calibration of an Apollo 17 far UV spectrometer are described. The absolute reference standards were photoelectric diodes calibrated at the National Bureau of Standards. A complete vacuum optical facility, which included a premonochromator and stable UV light sources, was developed to calibrate the Apollo 17 instrument, and it has been used for a number of other tasks. Absolute radiometric calibrations between about 1200 and 1700 A were performed with an absolute accuracy of + or - 10%. The light source, which was designed to provide a very stable light output, is a low-pressure molecular hydrogen lamp in which the pressure is stabilized by thermal control of uranium hydride powder.-

Fastie, W. G.↗

Scientific value of Seasat for geodesy

SEASAT altimetry data which relate directly to geoid heights provide the means to obtain information on the geoid on a global scale which is not attenuated by height or by high frequency averaging. The most important geodetic application of these data is to provide a standard reference surface for oceans.

Chovitz, B. H.↗

Effect of ball geometry on endurance limit in bending of drilled balls

Four designs of drilled (cylindrically hollow) balls were tested for resistance to bending fatigue. Bending fatigue has been demonstrated to be a limiting factor in previous evaluations of the drilled ball concept. A web reinforced drilled ball was most successful in resisting bending fatigue. Another design of through drilled design, involving a heavier wall than the standard reference ball, also showed significant improvement in resistance to bending fatigue.

Munson, H. E.↗