Search NASA⌕ Search

SEARCH · Search NASA

Results for “SLD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

80 records · Page 5

A Preliminary Study of Inter-Facility LWC Differences in Appendix C and Supercooled Large Drop Conditions due to Calibration Instruments

The simulation of clouds containing Supercooled Large Droplets has received increasing attention due to the introduction of Appendix O and future associated requirements for means of compliance. Supercooled Large Droplet conditions can cover four orders of magnitude in drop sizes, imposing a larger instrument measurement challenge than for Appendix C conditions. Wind tunnel facilities have adopted different instrumentation for liquid water content measurement, with fundamentally different principles of operation. In order to explore the comparability of the different instruments used for Appendix C and SLD measurement, and its impact on confidence in measurements used for means of compliance, a project was established to conduct a series of dedicated tests at three wind tunnel facilities. To date, liquid water content measurements have been completed using a Multi-Element sensor as the common instrument at two of the facilities. The data have provided preliminary information suggesting that substantial inter-facility differences likely exist in liquid water content estimates in Supercooled Large Droplet conditions that appear to be largely attributable to the choice of calibration instruments. These results are dependent on the assumption that the Multi-Element probe would produce equivalent measurements at the two facilities if the liquid water content were the same, regardless of other environmental differences that may exist between the two facilities. Planned further testing with other liquid water content measurement techniques may provide further information to confirm or refute the results of this study.

aircraft icing↗

Ice Accretion Roughness Variations on a Hybrid CRM65-Midspan Wing Model

Ice accretion roughness measurements were performed in the Icing Research Tunnel (IRT) at NASA Glenn Research Center for the Hybrid CRM65-Midspan model in a range of icing conditions. The Hybrid CRM65-Midspan model was chosen for this investigation because 1) the model exhibits high sweep relative to models previously explored in the roughness investigations, 2) the model has leading edge characteristics similar to wing shapes currently used in mid-size commercial airliners, and 3) the sweep and thickness ratios relate better to hybrid lifting body designs for N+2 and N+3 vehicles than other models available. The investigation consisted of multiple sets of tests which focused on 1) 0-angle of attack cases replicating the conditions employed by Anderson et al. (1998) using both Appendix C and SLD cloud conditions, 2) cases based on the “Max Scallop” case by Broeren et al. (2016) and a “High Temperature” case with cloud properties similar to the “Max Scallop” case. Additional tests were performed 1) based on the “Max Scallop” case with variations in freestream static temperature and 2) using test section speeds near 10,000-hold flight conditions. The point clouds were characterized using the approach of McClain and Kreeger (2013) for the ice roughness variations and using the approach of McClain (2016) for the mean ice thickness variations. The resulting roughness and mean thickness variations generally follow the temporal scaling previously identified using on airfoil models without sweep, but the collapse of the time progression profiles is not as tight as found for past measurements on models without sweep. LEWICE and modified panel-method predictions were used explore spatial roughness variations and to compare to the roughness correlations developed by McClain et al. (2021) for the “Max Scallop” cases.

Icing↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15um to 460 um. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

NASA Icing Update – May 2024

This presentation provides a status update on select NASA icing research activities for the SAE AC-9C Icing Technical Committee Meeting on May 6, 2024. The updates include the following topics: (1) Propulsion Systems Lab (PSL), (2) Adaptive Icing Tunnel (AIT), (3) Ice Adhesion / Deformed Skin Adhesion Test, (4) GlennICE, (5) Efficient Quiet Integrated Propulsor, (6) Icing Research Tunnel (IRT) CFD Characterization, and (7) Supercooled Large Droplet (SLD) Research.

Icing↗

Wind Tunnel PSD and MVD Characterization Using New 1D2D Optical Array Probes

This work explores characterization of the liquid clouds using a combination of a forward scattering probe and two Optical Array Probes. Current OAP probes provide particle shape, size, and number concentration from two-dimensional shadow images. However, past studies have shown that such images are subject to distortion when outside of the focal plane. This affects the retrieval of particle size distributions, particularly in the Supercooled Large Droplet size range. In this article, the use of a Droplet Measurement Technologies Cloud Droplet Probe and two new OAPs produced by Science Engineering Associates, is examined using wind tunnel data, to assess suitability for use in a wind tunnel calibration in SLD conditions. The new OAP probes exploit a flexible and simple grey scale imaging method to eliminate some present shortcomings of commonly used OAPs, and to reduce correction factors. Spinning disk measurements were used to specify probe depth of field, and average size errors. Composite spectra covering the nominal 2-3200 µm size range were formed by crossing over from the CDP to 1D2D-X at 48 µm, and then to the 1D2D-Y at about 400 µm. A good overlap was found at the crossover points without any artificial scaling. Composite spectra adequately closed the liquid water content distribution, and provided integrated LWCs within about 35% of the hot-wire LWCs used for tunnel calibration. This discrepancy was at least partially attributed to LWC underestimation by the hot-wire at high MVD. A model of probe performance was used to show an example of expected accuracy of ideal probes subject to the same OAP distortions and using the same mitigating procedures and corrections, predicting PSD Median Volume Diameter and integrated LWC errors of less than 10%.

Aircraft Icing↗

Ice Accretion Roughness Measurements and Modeling

Roughness on aircraft ice accretions is very important to the overall ice accretion process and to the resulting degradation in aircraft aerodynamic performance. Roughness enhances the local convection leading to more rapid ice accumulation rates, and roughness generates local flow perturbations that lead to higher skin friction. This paper presents 1) a review of the developments in ice shape three-dimensional laser scanning developed at NASA Glenn, 2) a review of the approach of McClain and Kreeger employed to characterize ice roughness evolution on an airfoil surface, and 3) a review of the experimental efforts that have been performed over the last five years to characterize, scale, and model ice roughness evolution physics.

SLD↗

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This paper presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the test section. Some icing spray clouds with large drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow in the measurement area of the probe between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a pitot-static probe affixed on the mounting plate next to the stand. Those findings were later verified in the Icing Research Tunnel using a new pitot-static probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations were performed with the airflow moving towards the probe head with a Langmuir-D 7-bin distribution cloud containing large drops. The simulation results helped identify a critical drop-size threshold of 300 μm above which the velocities of larger drops are negligibly affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD↗

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This presentation presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the tunnel test section. Some icing spray clouds with large-sized drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a Pitot static probe affixed on the mounting plate. Those findings were later verified in the Icing Research Tunnel using a new Pitot probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations as airflow moving towards the probe head were run for a Langmuir-D 7-bin drop size distribution of a spray cloud with a nominally large value of medium volumetric diameter. The simulation results helped identify a critical drop-size threshold of 300 µm above which the velocities of larger drops are not affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD↗