Search NASA⌕ Search

SEARCH · Search NASA

Results for “STABLE OSCILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Small Spacecraft for Planetary Atmospheric, Surface, and Interior Structure Using Radio Links

Scientific studies using spacecraft radio links have been conducted on almost every Solar System exploration mission in the past five decades and have led to numerous discoveries. Radio Science experiments have elucidated the thermal history of the Moon from high resolution gravitational field measurements, unveiled the interiors of Titan, Enceladus, Mercury, Phobos, Vesta and Ceres providing key evidence for identifying subsurface oceans on icy moons; sounded Titan, Saturn, and Pluto’s atmospheres, and refined models for the atmospheres, surfaces, and interior structure of Mars and Venus. A Juno experiment is in progress measuring the gravitational field of Jupiter to reveal its interior structures, as did a similar recent Cassini experiment with Saturn. Experiments at Mercury, the Jovian system, and other targets, are in development or planning phases. Over the next 30 years, significant advances in radio and laser link-science technologies, including nearly one order of magnitude improvement achievable in range-rate and range accuracy, could enable many new scientific breakthroughs. Future exploration concepts in many cases focus on applications of small spacecraft and can include spacecraft constellations for studies of atmospheric dynamics, interior structures, and surface properties. A set of science-enabling radio link technologies specific to small spacecraft instrumentation on future solar system missions are under study and development. Examples include field tests of radio scattering to determine soil properties, smallsat constellations for dense geographic and temporal atmospheric probing, small science-quality software-defined transponders, miniature ultra-stable oscillators, and advanced radio-metric calibrations at the Deep Space Network. This paper describes many of these technologies and their scientific applications.

Elliott, Harvey↗

Galactic oscillations

A stable galaxy, if excited above its ground state, oscillates about that ground state. If it is resonably robust, it can support oscillations of large amplitude. Normal mode oscillations, with surprisingly large amplitudes, have been seen in numerical experiments. Observational evidence shows that real galaxies also oscillate. Galaxies ring like a bell in the experiments, and ringing continues undamped long after initial transients have died out. Their total kinetic energy oscillates with an amplitude as large as 10% of the mean. A fundamental mode dominates. It is homologous expansion/contraction of the entire galaxy (no nodes). Inward or outward velocities due to this mode are sufficiently large in the outer reaches of a galaxy to account for kinematic warps in observed velocity fields. A second spherically symmetrical mode has one node and is important near the center of the galaxy. It may be the driving force behind bulges in spiral galaxies. Two other normal modes have been identified as well. This appears to be the first experimental demonstration of normal mode oscillations within stable galaxy models.

Miller, R. H.↗

A stable, linear frequency-modulated oscillator, part 1

The development of a push-pull frequency-modulated oscillator employing field-effect transistors is described. The advantages of field-effect transistors for use in a frequency-stable oscillator are presented. Linearization of the frequency deviation was accomplished by utilizing the square-law characteristic of an FET used as a modulating amplifier. The push-pull oscillator model produced a linear frequency deviation of more than 10 MHz at a center frequency of approximately 100 MHz. Output power is within 0.6 db of a nominal +8.5 dBm over the desired frequency range, and the modulation bandwidth is dc to 10 MHz. Frequency variation with temperature after compensation with a negative-temperature-coefficient capacitor is within + or - 0.05% from 0 to 60 C.

Honnell, M. A.↗

Coupled opto-electronic oscillator

A coupled opto-electronic oscillator that directly couples a laser oscillation with an electronic oscillation to simultaneously achieve a stable RF oscillation at a high frequency and ultra-short optical pulsation by mode locking with a high repetition rate and stability. Single-mode selection can be achieved even with a very long opto-electronic loop. A multimode laser can be used to pump the electronic oscillation, resulting in a high operation efficiency. The optical and the RF oscillations are correlated to each other.

Yao, X. Steve↗

Ultra-Stable Superconducting-Maser Oscillator

Unprecedented stability of frequency in superconducting, triple-cavity ruby maser oscillator achieved by incorporation of amplitude-control subsystem. New design enhances ultra-stable measurements of time by reducing fluctuations to 2 X 10 to negative 19th power routinely, and to as little as 10 to negative 20th power in exceptional cases. Currents induced in superconducting pickup coil by changes in magnetic field in ruby. Currents from coil fed to superconducting quantum-interference device (SQUID) magnetometer, output used to generate control signal for electronically variable attenuator. Attenuator varies pump-signal amplitude in response to magnetic-field fluctuations in ruby. Very high feedback-loop gain used for sensitivity of control and adequate compensation of fluctuations.

Strayer, Donald M.↗

Phase noise effects on turbulent weather radar spectrum parameter estimation

Accurate weather spectrum moment estimation is important in the use of weather radar for hazardous windshear detection. The effect of the stable local oscillator (STALO) instability (jitter) on the spectrum moment estimation algorithm is investigated. Uncertainty in the stable local oscillator will affect both the transmitted signal and the received signal since the STALO provides transmitted and reference carriers. The proposed approach models STALO phase jitter as it affects the complex autocorrelation of the radar return. The results can therefore by interpreted in terms of any source of system phase jitter for which the model is appropriate and, in particular, may be considered as a cumulative effect of all radar system sources.

Lee, Jonggil↗

Characterization of Low-Frequency Combustion Stability of the Fastrac Engine

A series of tests were conducted to measure the combustion performance of the Fastrac engine thrust chamber. During mainstage, the thrust chamber exhibited no large-amplitude chamber pressure oscillations that could be identified as low-frequency combustion instability or 'chug'. However, during start-up and shutdown, the thrust chamber very briefly exhibited large-amplitude chamber pressure oscillations that were identified as chug. These instabilities during start-up and shutdown were regarded as benign due to their brevity. Linear models of the thrust chamber and the propellant feed systems were formulated for both the thrust chamber component tests and the flight engine tests. These linear models determined the frequency and decay rate of chamber pressure oscillations given the design and operating conditions of the thrust chamber and feed system. The frequency of chamber pressure oscillations determined from the model closely matched the frequency of low-amplitude, low-frequency chamber pressure oscillations exhibited in some of the later thrust chamber mainstage tests. The decay rate of the chamber pressure oscillations determined from the models indicated that these low-frequency oscillations were stable. Likewise, the decay rate, determined from the model of the flight engine tests indicated that the low-frequency chamber pressure oscillations would be stable.

Rocker, Marvin↗

Temperature-stable Gunn-diode oscillator

Oscillator consisting of Gunn diode embedded in coaxial circuit has excellent temperature stability and low fabrication costs as compared with automatic-frequency-control crystal oscillators.

Dengenford, J. E.↗

A stable submillimeter laser local oscillator for heterodyne radiometry and spectroscopy

A submillimeter laser with off-axis pump beam injection is described. This design concept achieves complete isolation of the pump laser with respect to the pump radiation reflected from the submillimeter resonator. Active line independent stabilization of the pump laser is obtained by the use of an external tunable etalon as a frequency reference. The submillimeter output power is constant to within 4% over periods of hours. Mean frequency drifts of less than 2 parts in 100 million per minute were measured by mixing with very high harmonics of an X-band synthesizer in a planar Schottky diode.

Koepf, G. A.↗

US Space VLBI Proposed Outreach Web Site

The study of how VLBI might be pursued in space began in the late 1970's, when it was realized that the size of the earth was a serious limitation to the study of compact radio sources. By going to space, achieving angular resolution at radio wavelengths that could not be obtained with VLBI systems that were limited by the size of the earth, important tests could not be made of quasar models. The technology appeared to be within reach, and an early space VLBI concept, QUASAT, emerged as a joint project, involving both US and European scientists. In 1984, a workshop was held in Gross Enzerdorf, Austria, under joint sponsorship of NASA and the European Space Agency (ESA). The principal conclusion of the workshop was that a VLBI station in space, telemetering its data to ground data stations, working in connection with ground-based radio telescopes, would give the opportunity to achieve angular resolution of a few tens of micro-arc-seconds, and could develop high-quality radio maps of many classes of radio sources. The ground telemetry stations would also function as the source of a stable local oscillator for the spacecraft, which needs a highly stable frequency reference. The Deep Space Network of NASA could play a vital role in both the frequency-locking system and data acquisition. One outcome of the Gross Enzerdorf workshop was the convening, by COSPAR, of an ad hoc Committee on Space VLBI, to review and recommend procedures by which international collaboration on VLBI in space might be coordinated and promoted. In October 1985, the committee met in Budapest and recommended that the Inter-Agency Consultative Group (IACG) would be an appropriate body to coordinate VLBI activities in space. At the same time ESA convened a committee to explore the technical aspects of coordinating ground and space VLBI activities. At this stage both NASA and ESA were supporting preliminary studies of the QUASAT mission, with effective coordination between the two groups. The Soviet Union had also begun planning a mission with the clear intent to fly it as soon as the could; the mission was designated RadioAstron. In December 1985, the Soviets formed an international study team for the RadioAstron mission, holding the first meeting in Moscow. Subsequent meetings of this international committee were held in Budapest in May 1986 and in Moscow in December 1986. Thus, in 1986 there were three VLBI mission concepts under study: the NASA QUASAT mission, an ESA counterpart, and the Soviet RadioAstron mission.

Source record↗

Resonant X-ray excitation of the nuclear clock isomer 45 Sc

Resonant oscillators with stable frequencies and large quality factors help us to keep track of time with high precision. Examples range from quartz crystal oscillators in wristwatches to atomic oscillators in atomic clocks, which are, at present, our most precise time measurement devices. The search for more stable and convenient reference oscillators is continuing. Nuclear oscillators are better than atomic oscillators because of their naturally higher quality factors and higher resilience against external perturbations. One of the most promising cases is an ultra-narrow nuclear resonance transition in 45 Sc between the ground state and the 12.4-keV isomeric state with a long lifetime of 0.47 s (ref. 10 ). The scientific potential of 45 Sc was realized long ago, but applications require 45 Sc resonant excitation, which in turn requires accelerator-driven, high-brightness X-ray sources that have become available only recently. Here we report on resonant X-ray excitation of the 45 Sc isomeric state by irradiation of Sc-metal foil with 12.4-keV photon pulses from a state-of-the-art X-ray free-electron laser and subsequent detection of nuclear decay products. Simultaneously, the transition energy was determined as ${\mathrm{12,389.59}}_{+0.12\left({\rm{syst}}\right)}^{\pm 0.15\left({\rm{stat}}\right)}\,{\rm{eV}}$ with an uncertainty that is two orders of magnitude smaller than the previously known values. These advancements enable the application of this isomer in extreme metrology, nuclear clock technology, ultra-high-precision spectroscopy and similar applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Current developments in SAW oscillator stability

The results reported were obtained with two port delay lines and resonators used in a simple feedback oscillator. The feedback oscillator employed inherently operates with the amplifier in a saturated condition and, therefore, the AM noise is suppressed. Consequently the dominant noise is FM. Generally, it can be concluded that for very narrow-band, or fixed-frequency applications, the resonator-type oscillator will give the best noise performance. For applications where tunability and linearity are important, the delay-line-type oscillator may give the best performance. There have been no significant improvements in oscillator temperature stability. The only two demonstrated materials for temperature stable SAW oscillators are ST-cut quartz and the SiO2/LiTaO3 overlay structure. Aging tests have been going on for the past two-and-a-half years and it has become obvious that the observed aging rates are largely related to cleaning and packaging.

Parker, T. E.↗

Mach 10 bow-shock behavior of a forward-facing nose cavity

A detailed description of the bow-shock behavior associated with a conical-walled cavity with a flat circular base at M(infinity) = 10 is presented. An experimental test was performed on this configuration, and measurements of shock-oscillation frequency and amplitude, as well as shock shape, were recorded by a number of techniques. A laser-interferometer system was used for the first time during this test to determine bow-shock oscillation frequency in a nonintrusive manner. The primary behavior was a stable, periodically oscillating bow shock. Attention is also given to a violent bow-shock instability.

Huebner, Lawrence D.↗

Use of the quartz crystal microbalance to determine the monomeric friction coefficient of polyimides

When a thin film of polymer is coated on to a quartz crystal microbalance (QCM), the QCM can be used to detect the rate of increase in weight of the polymer film as the volatile penetrant diffuses into the polymer. From this rate information the diffusion coefficient of the penetrant into the polymer can be computed. Calculations requiring this diffusion coefficient lead to values which approximate the monomeric friction coefficient of the polymer. This project has been concerned with the trial of crystal oscillating circuits suitable for driving polymer coated crystals in an atmosphere of penetrant. For these studies done at room temperature, natural rubber was used as an easily applied polymer that is readily penetrated by toluene vapors, qualities anticipated with polyimides when they are tested at T(g) in the presence of toluene. Three quartz crystal oscillator circuits were tested. The simplest circuit used +/- 5 volt dc and had a transistor to transistor logic (TTL) inverter chip that provides a 180 deg phase shift via a feed back loop. This oscillator circuit was stable but would not drive the crystal when the crystal was coated with polymer and subjected to toluene vapors. Removal of a variable resistor from this circuit increased stability but did not otherwise increase performance. Another driver circuit tested contained a two stage differential input, differential output, wide band video amplifier and also contain a feed back loop. The circuit voltage could not be varied and operated at +/- 5 volts dc; this circuit was also stable but failed to oscillate the polymer coated crystal in an atmosphere saturated with toluene vapors. The third oscillator circuit was of similar construction and relied on the same video amplifier but allowed operation with variable voltage. This circuit would drive the crystal when the crystal was submerged in liquid toluene and when the crystal was coated with polymer and immersed in toluene vapors. The frequency readings obtained when using this oscillating circuit are highly variable. This circuit requires further modification to stabilize frequency readings before its use in studies to determine the diffusion coefficient of penetrant molecules into a polymer film coated on a QCM.

Bechtold, Mary M.↗

Design and progress report for compact cryocooled sapphire oscillator 'VCSO'

We report on the development of a compact cryocooled sapphiere oscillator 'VCSO', designed as a higher-performance replacement for ultra-stable quartz oscillators in local oscillator, cleanup, and flywheel applications in the frequency generation and distribution subsystems of NASA's Deep Space Network (DSN).

oscillator↗