At least 91 records · Page 5

Shuttle program standard maneuver sequences for orbiter/upper-stage separation SSUS-A, SSUS-D, and IUS

Descriptions of standard post-ejection maneuver sequences for the deployment of IUS, SSUS-A, and SSUS-D upper stages from the space shuttle orbiter are presented. The sequences were designed to satisfy requirements for limiting the damage inflicted on the orbiter by upper-stage exhaust particles, subject to a further requirement for minimizing the impingement of orbiter thruster plumes on the deployed payload. In all cases it was assumed that the orbital maneuvering system engines would be used to apply the orbiter's major separation velocity increment.

Wilson, S. W.↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Hughes advanced nickel-cadmium batteries: An update

After delivering a significant data base on boilerplate and prototype advanced nickel cadmium (Ni/Cd) battery cells, Hughes decided to start using the Advanced Ni/Cd batteries on several of their flight programs. The advanced cell can been operated at 80 percent depth of discharge (DOD) for more than 10 years, and possibly 15 years, in geosynchronous earth orbit (GEO) applications. This cell offers an important weight saving over the standard Ni/Cd cell that is usually only operated at 50 to 60 percent DOD in GEO applications. The negative and positive electrodes are manufactured using electrochemical deposition methods which reduce the sinter corrosion problems encountered by the chemical deposition process used in the standard cells. The degradable nylon separators used in standard cells was replaced by polymer impregnated Zirconia separators.

Bogner, R. Sam↗

Radiochronometric analysis of an historic Cs-137 activity standard

In this work, a 137 Cs activity standard discovered during routine inventory was analyzed to determine its model age using radiochronometry. The aqueous activity standard was separated using an established separation method that employs commercially available Sr resin. The method was also tested against a nuclear forensics reference material developed specifically for benchmarking 137 Cs radiochronometry methods. Results of the analyses showed good agreement between the results and the certified values of the reference material. Analysis of the discovered activity standard were also in good agreement with the activity certification date, though uncertainty was higher due to natural Ba contaminating the sample and the stable 133 Cs used as a carrier during the standard’s production.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of Contact Separation Force Testing as a Screening Methodology for Electrical Socket Contacts

During system level testing intermittent and permanent open circuit failures of mated, crimp removable, electrical contact pairs were experienced. The root cause of the failures was determined to be low (but not zero) contact forces applied by the socket contact tines against the engaging pin. The low contact force reduces the effectiveness of the wiping action of the socket tines against the pin. The observed failure mode may be produced when insufficient wiping during mate, demate and small relative movement in use allows for the accumulation of debris or insulating films that electrically separate the contact pair. The investigation identified at least three manufacturing process control problems associated with the socket contacts that enabled shipment of contacts susceptible to developing low contact forces: (1) Improper heat treatment of the socket tines resulting in plastic rather than elastic behavior; (2) Overly thinned socket tines at their base resulting in reduced pin retention forces; (3) Insufficient screening tests to identify parts susceptible to the aforementioned failure mechanisms. The results from an extensive screening program of socket contacts utilizing the industry standard contact separation force test procedures are described herein. The investigation shows this method to be capable of identifying initially weak sockets. However, sockets whose contact retention forces may degrade during use may not be screened out by pin retention testing alone. Further investigations are required to correlate low contact retention forces with increased electrical contact resistance in the presence of insulating films that may accumulate in the use environment.

Christopher Green↗

Estimating Climatological Bias Errors for the Global Precipitation Climatology Project (GPCP)

A procedure is described to estimate bias errors for mean precipitation by using multiple estimates from different algorithms, satellite sources, and merged products. The Global Precipitation Climatology Project (GPCP) monthly product is used as a base precipitation estimate, with other input products included when they are within +/- 50% of the GPCP estimates on a zonal-mean basis (ocean and land separately). The standard deviation s of the included products is then taken to be the estimated systematic, or bias, error. The results allow one to examine monthly climatologies and the annual climatology, producing maps of estimated bias errors, zonal-mean errors, and estimated errors over large areas such as ocean and land for both the tropics and the globe. For ocean areas, where there is the largest question as to absolute magnitude of precipitation, the analysis shows spatial variations in the estimated bias errors, indicating areas where one should have more or less confidence in the mean precipitation estimates. In the tropics, relative bias error estimates (s/m, where m is the mean precipitation) over the eastern Pacific Ocean are as large as 20%, as compared with 10%-15% in the western Pacific part of the ITCZ. An examination of latitudinal differences over ocean clearly shows an increase in estimated bias error at higher latitudes, reaching up to 50%. Over land, the error estimates also locate regions of potential problems in the tropics and larger cold-season errors at high latitudes that are due to snow. An empirical technique to area average the gridded errors (s) is described that allows one to make error estimates for arbitrary areas and for the tropics and the globe (land and ocean separately, and combined). Over the tropics this calculation leads to a relative error estimate for tropical land and ocean combined of 7%, which is considered to be an upper bound because of the lack of sign-of-the-error canceling when integrating over different areas with a different number of input products. For the globe the calculated relative error estimate from this study is about 9%, which is also probably a slight overestimate. These tropical and global estimated bias errors provide one estimate of the current state of knowledge of the planet's mean precipitation.

Global Precipitation Climatology Project (GPCP)↗

Tuned Reactivity at the Lithium Metal–Argyrodite Solid State Electrolyte Interphase

Thin intermetallic Li 2 Te–LiTe 3 bilayer (0.75 µm) derived from 2D tellurene stabilizes the solid electrolyte interphase (SEI) of lithium metal and argyrodite (LPSCl, Li 6 PS 5 Cl) solid-state electrolyte (SSE). Tellurene is loaded onto a standard battery separator and reacted with lithium through single-pass mechanical rolling or transferred directly to SSE surface by pressing. State-of-the-art electrochemical performance is achieved, e.g., symmetric cell stable for 300 cycles (1800 h) at 1 mA cm -2 and 3 mAh cm -2 (25% DOD, 60 µm foil). Cryo-stage focused ion beam (Cryo-FIB) sectioning and Raman mapping demonstrate that the Li 2 Te–LiTe 3 bilayer impedes SSE decomposition. The unmodified Li–LPSCl interphase is electrochemically unstable with a geometrically heterogeneous reduction decomposition reaction front that extends deep into the SSE. Decomposition drives voiding in Li metal due to its high flux to the reaction front, as well as voiding in the SSE due to the associated volume changes. Analysis of cycled SSE found no evidence for pristine (unreacted) lithium metal filaments/dendrites, implying failure driven by decomposition phases with sufficient electrical conductivity that span electrolyte thickness. In conclusion, DFT calculations clarify thermodynamic stability, interfacial adhesion, and electronic transport properties of interphases, while mesoscale modeling examines interrelations between reaction front heterogeneity (SEI heterogeneity), current distribution, and localized chemo-mechanical stresses.

25 ENERGY STORAGE↗

Engineered Pseudomonas putida simultaneously catabolizes five major components of corn stover lignocellulose: Glucose, xylose, arabinose, p-coumaric acid, and acetic acid

Valorization of all major lignocellulose components, including lignin, cellulose, and hemicellulose is critical for an economically viable bioeconomy. In most biochemical conversion approaches, the standard process separately upgrades sugar hydrolysates and lignin. Here, we present a new process concept based on an engineered microbe that could enable simultaneous upgrading of all lignocellulose streams, which has the ultimate potential to reduce capital cost and enable new metabolic engineering strategies. Specifically, we engineered Pseudomonas putida, a robust microorganism capable of catabolizing aromatic compounds, organic acids, and D-glucose, to utilize D-xylose and L-arabinose by tuning D-xylose transport and pentose phosphate pathway flux. Distinct L-arabinose pathways enabled D-glucose, D-xylose, and L-arabinose co-utilization in minimal medium using model compounds as well as corn stover hydrolysate. After modifying catabolite repression, our engineered P. putida simultaneously co-utilized five representative compounds from cellulose, hemicellulose, and lignin, demonstrating the feasibility of simultaneously upgrading total lignocellulosic biomass to value-added chemicals.

Elmore, Joshua R.↗

NERVA mass properties computer methodology

The computer codes are presented that were used for the weight, center of gravity, and mass moment of inertia calculations and documentation for the NERVA. The two programs, E15301 and 12001B, are the basic tools used for weights work on the NERVA program. Used in conjunction with one another, they allow for rapid weights estimates for new concepts or changes while allowing for orderly documentation, which is a necessity in any effective weights effort. Program E15301 requires that each component be resolved into a collection of standard shapes. Separate subroutines then process geometric and material density data for each entry. The master program the performs all calculations necessary to combine these results into a total weight, center of gravity, and moment of inertia for the component. Program 12001B accepts previously calculated weight and center of gravity data for individual components. The program sums weights and calculates center of gravities and moments of inertia for systems of up to four levels of assemblies. The output identifies the engine parts in a format usable directly in a formal report.

Hall, I. K.↗

Hydrogen Masers as Time and Frequency Standards

Track each other with 100 times more precision than cesium standards. Geographically separated hydrogen masers tracked each other for more than year to within few parts in 10 to the 15th power. Frequency offset of hydrogen-maser output from hyperfine line frequency is function of ambient magnetic field, cavity mistuning, thermal motion of atoms in cavity and collisions of atoms with walls of the cavity. If maser remains at one location some of small offsets in frequency will remain constant throughout life of maser.

Ward, S. C.↗

Feature selection methodologies using simulated Thematic Mapper data

The present investigation is concerned with the determination of the intrinsic dimensionality of a simulated Thematic Mapper data set. In addition, the effectiveness and sensitivity of 'standard' statistics separability measures (i.e., transformed divergence) is evaluated in comparison to eigenvectors for identifying the optimum subset of the original Thematic Mapper Simulator (TMS) bands for classifying the various cover types. TMS data were collected on May 2, 1979 by NASA's NS001 aircraft multispectral scanner over a bottomland forested area in South Carolina near the city of Camden. It is found that the eigenvectors and eigenvalues of a covariance matrix from a multispectral scanner system (MSS) data set can be obtained without having to actually transform the data.

Dean, M. E.↗

Free flow cell electrophoresis using zwitterionic buffer

Studies of a zwitterionic buffer formulated for cell electrophoresis were done using the McDonnell-Douglas Continuous Flow Electrophoresis System. Standard buffers were analyzed for their stability in the electrical field and the results showed that both buffers tested were inherently unstable. Further, titration studies showed that the standards buffers buffered poorly at the pH employed for electrophoresis. The zwitterionic buffer buffered well at its nominal pH and was shown to be stable in the electrical field. Comparative studies of the buffer with standard cell separation buffers using formalin fixed rabbit and goose red blood cells showed that the zwitterionic buffer gave better resolution of the fixed cells. Studies with viable hybridoma cells showed that buffer Q supported cell viability equal to Hank's Balanced Salt Solution and that hybridoma cells in different stages of the growth cycle demonstrated reproducible differences in electrophoretic mobility.

Rodkey, R. Scott↗

The age of the Pretoria Saltpan impact crater, South Africa

The Pretoria Saltpan impact crater, situated about 40 km NNW of Pretoria, South Africa, has a diameter of about 1.13 km. The structure was formed in 2.05 Ga Nebo granite of the Bushveld Complex. The impact origin of the crater was recently established by the discovery of characteristic shock-metamorphic features in breccias found in drill cores at depths greater than 90 m. Impact glass fragments were recovered by standard magnetic separation techniques and handpicking from the melt breccias. As no reliable crater age was known so far, several hundred sub-millimeter-sized glass fragments were studied for fission tracks. The results show that the Saltpan impact crater has an age of 220 +/- 52 ka. This is in agreement with field geological observations.

Storzer, Dieter↗

Histogrammatic Method for Determining Relative Abundance of Input Gas Pulse

To satisfy the Major Constituents Analysis (MCA) requirements for the Vehicle Cabin Atmosphere Monitor (VCAM), this software analyzes the relative abundance ratios for N2, O2, Ar, and CO2 as a function of time and constructs their best-estimate mean. A histogram is first built of all abundance ratios for each of the species vs time. The abundance peaks corresponding to the intended measurement and any obfuscating background are then separated via standard peak-finding techniques in histogram space. A voting scheme is then used to include/exclude this particular time sample in the final average based on its membership to the intended measurement or the background population. This results in a robust and reasonable estimate of the abundance of trace components such as CO2 and Ar even in the presence of obfuscating backgrounds internal to the VCAM device. VCAM can provide a means for monitoring the air within the enclosed environments, such as the ISS (International Space Station), Crew Exploration Vehicle (CEV), a Lunar Habitat, or another vehicle traveling to Mars. Its miniature pre-concentrator, gas chromatograph (GC), and mass spectrometer can provide unbiased detection of a large number of organic species as well as MCA analysis. VCAM s software can identify the concentration of trace chemicals and whether the chemicals are on a targeted list of hazardous compounds. This innovation s performance and reliability on orbit, along with the ground team s assessment of its raw data and analysis results, will validate its technology for future use and development.

Mandrake, Lukas↗

Detecting Nanophase Weathering Products with CheMin: Reference Intensity Ratios of Allophane, Aluminosilicate Gel, and Ferrihydrite

X-ray diffraction (XRD) data collected of the Rocknest samples by the CheMin instrument on Mars Science Laboratory suggest the presence of poorly crystalline or amorphous materials [1], such as nanophase weathering products or volcanic and impact glasses. The identification of the type(s) of X-ray amorphous material at Rocknest is important because it can elucidate past aqueous weathering processes. The presence of volcanic and impact glasses would indicate that little chemical weathering has occurred because glass is highly susceptible to aqueous alteration. The presence of nanophase weathering products, such as allophane, nanophase iron-oxides, and/or palagonite, would indicate incipient chemical weathering. Furthermore, the types of weathering products present could help constrain pH conditions and identify which primary phases altered to form the weathering products. Quantitative analysis of phases from CheMin data is achieved through Reference Intensity Ratios (RIRs) and Rietveld refinement. The RIR of a mineral (or mineraloid) that relates the scattering power of that mineral (typically the most intense diffraction line) to the scattering power of a separate mineral standard such as corundum [2]. RIRs can be calculated from XRD patterns measured in the laboratory by mixing a mineral with a standard in known abundances and comparing diffraction line intensities of the mineral to the standard. X-ray amorphous phases (e.g., nanophase weathering products) have broad scattering signatures rather than sharp diffraction lines. Thus, RIRs of X-ray amorphous materials are calculated by comparing the area under one of these broad scattering signals with the area under a diffraction line in the standard. Here, we measured XRD patterns of nanophase weathering products (allophane, aluminosilicate gel, and ferrihydrite) mixed with a mineral standard (beryl) in the CheMinIV laboratory instrument and calculated their RIRs to help constrain the abundances of these phases in the Rocknest samples.

Rampe, E. B.↗

Define Minimum Safe Operational Volume for Aerial Vehicles in Upper Class E Airspace

This work presents both analytical and simulation studies for defining the minimum safe operational volume needed for aerial vehicles operating in upper Class E airspace. The analytical study is conducted first to investigate factors that affect the minimum safe operational volume, such as position errors, wake/vortex, vehicle maneuverability, communication and surveillance, control/operator response time. A mathematical approach is developed to compute the boundary of the safe operational volume required by the limited aircraft maneuverability and an analytical sensitivity study is then performed with varying parameters. After the analytical study, simulations are then conducted to verify the results from the analytical study. Simulation results will be included in the final paper.

Separation standard, well-clear definition, upper ↗