Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source code instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Optics of the NIFS negative ion source test stand by infrared calorimetry and numerical modelling

At National Institute for Fusion Science (NIFS), a multi-ampere negative ion source is used to support the R&D on H{sup −} production, extraction, and acceleration. In this contribution, we study the characteristics of the acceleration system of this source, in order to characterize the beam optics at different operational conditions. A dedicated experimental campaign was carried out at NIFS, using as main diagnostic the infra-red imaging of the beam profiles. The experimental measurements are also compared with 3D numerical simulations, in order to validate the codes and to assess their degree of reliability. The simulations show a satisfactory agreement with the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Encoded Gamma-Ray Imaging Using a 3-D Position-Sensitive CdZnTe Detector Array

The gamma-ray response of thick pixelated CdZnTe detectors varies spatially but is relatively constant as a function of time. Detector irregularities arise from flaws in the material, electrode fabrication, and gaps between the detectors in an array. These nonuniformities generate artifacts in coded aperture images that can obscure a source of interest. This article presents the theory, design, and demonstration of a 3-D CdZnTe-based time-encoded imager. Experimental results show the gamma-ray images of point-like and extended 57 Co and HEU-metal sources formed using a spatially nonuniform 3-D CdZnTe detector array and moving coded aperture mask. Image signal-to-noise ratio (SNR) for a point source was within 10% of its statistical limit at 250k counts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly Extensible X-ray Diffraction Toolkit

This code has been previous released as open source under LLNL-CODE-529294. The HEXRD program comprises a library of X-ray diffraction analysis tools and a stand-alone GUI application. While there are many software packages that provide similar capabilities, HEXRD was designed to provide an extremely flexible and extensible basis for describing a broad array of X-ray diffraction instruments; this includes both mono- and poly-chromatic modalities as well as poly- and single-crystal samples. The high-level objects include Material: an abstraction for defining crystalline materials, including unit cell parameters and anisotropic elastic moduli Imageseries: an interface for series of diffraction images containing one or more frames, including provisions for metadata. Instrument: an abstraction of an X-ray diffraction instrument including support for the definition of multiple detector elements as well as powder, Laue, and mono-chromatic single/multi-grain diffraction analysis modalities (including attendant calibration routines). The hexrdgui package is a standalone PySide2/Qt5 GUI built on top of hexrd. The 0.8.1 release includes various bug fixes as well as some new functionality in the GUI, including: o Enhancements to the import tools for LLNL diffraction instruemtns (PXRDIP and TARDIS) o The ability to save 1-d LeBail fits of integrated diffraction spectra.

Barton, NathanR.↗

NDFOM Description for DNDO Summer Internship Program

Nuclear Detection Figure of Merit (NDFOM) is a DNDO-funded project at LANL to develop a software framework that allows a user to evaluate a radiation detection scenario of interest, quickly obtaining results on detector performance. It is intended as a “first step” in detector performance assessment, and meant to be easily employed by subject matter experts (SMEs) and non-SMEs alike. The generic scenario consists of a potential source moving past a detector at a relative velocity and with a distance of closest approach. Such a scenario is capable of describing, e.g., vehicles driving through portal monitors, border patrol scanning suspected illicit materials with a handheld instrument, and first responders with backpackor pager-based detectors (see Fig. 1). The backend library is prepopulated by the NDFOM developers to include sources and detectors of interest to DNDO and its community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Extension of SCALE/Sampler’s sensitivity analysis

Nuclear data are a major source of uncertainties in reactor physics calculations. The propagation of nuclear data uncertainties to important system responses is instrumental when determining appropriate safety margins in reactor safety analyses. It is also important to understand the major contributors to the observed uncertainties to make recommendations for further measurements and evaluations and aid in the understanding of the studied system. The SCALE code system allows for nuclear data uncertainty analysis based on the random sampling approach as implemented in SCALE’s Sampler sequence. Sampler was recently extended by a sensitivity analysis in terms of the calculation of two correlation-based sensitivity indices. This analysis allows for the identification of the top contributing nuclear reactions to any analyzed output uncertainty. This paper presents the sensitivity indices, along with their interpretation and limitations. It demonstrates the application in an eigenvalue and decay heat analysis for a boiling water reactor fuel assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonuniform Absorption and Scattered Light in Direct-Drive Implosions Driven by Polarization Smoothing

Laser-direct-drive symmetric implosions on OMEGA illuminate a target with 60 laser beams and are designed to produce spherical implosions. Each beam is smoothed using orthogonal polarizations obtained by passing through distributed polarization rotators (DPR’s). Observations of the scattered light from OMEGA implosions do not show the expected symmetry and have much larger variation than standard predictions. For the first time, we have quantified the scattered-light nonuniformity from individual beams and identified the DPR’s as the source of the enhanced nonuniformity. An instrument was invented that isolated and measured the variation in the intensity and polarization of the light scattered from each OMEGA beam. The asymmetric intensity and polarization measurements are explained when the on-target offsets between the two orthogonal polarizations produced by the DPR’s are modeled using a 3-D cross-beam energy transfer (CBET) code that tracks the polarizations of each beam. The time-integrated nonuniformity in laser absorption and scattered light due to CBET and the DPR polarization offsets during high-performance OMEGA implosions is predicted to be significant and dominated by low spherical harmonic mode numbers. Further, the nonuniformity is predicted to be greatly reduced by replacing the DPR’s with new optics that create smaller offsets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of FRAM Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) code with a high purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, U 3 O 8 line sources, and a uranium tetrafluoride source. The 235 U enrichment was estimated using the FRAM isotopic analysis software for each source and compared with the declared isotopic values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DRiFT - Release 1.0.0 Organic Scintillators

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that postprocesses output from the extensively validated radiation transport code, MCNP [1], and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. Although DRiFT development has included scintillator [2], gas [3], and semiconductor features [4], the focus of this release is on organic scintillator and associated capabilities. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts [5, 6]. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80-channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, open-source pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of ion beam injection and extraction in an EBIS

An example simulation of Au+ charge breeding using FAR-TECH’s integrated EBIS (electron beam ion source) modeling toolset is presented with the emphasis on ion beam injection and extraction. The trajectories of injected ions are calculated with PBGUNS (particle beam gun simulation) self-consistently by including the space charges from both ions and electrons. The ion beam, starting with initial conditions within the 100% acceptance of the electron beam, is then tracked by EBIS-PIC (particle-in-cell EBIS simulation code). In the trap, the evolution of the ion charge state distribution is estimated by charge state estimator. The extraction of charge bred ions is simulated with PBGUNS. The simulations of the ion injections show significant ion space charge effects on beam capture efficiency and the ionization efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY25 Mid-Year Report: FNCL Enhancements Implementation

During the first half of FY25 the FNCL team has made consistent progress toward the completion of our project goals. The FNCL prototype panel design has been successfully applied to a fully instrumented 3-panel system which is actively under construction. The FNCL Demonstrator System contains solid scintillators instrumented with SiPMs, which operate on an updated CAEN digitizer, requires no high-voltage, and has a smaller overall footprint. The onboard software will include the LLNL-developed GMM-PSD signal processing. Later this year the system will be experimentally tested alongside the baseline FNCL instrument at LLNLs ISSA facility. In addition to a full systems test, the performance of a DD generator for active interrogation measurements compared to the standard AmLi source will be established for both systems. The data collected at the ISSA facility will be used to experimentally validate the FNCL-Fast Isotopic Fuel Assay’s (FIFA) capability to measure U-235 loading and to predict gadolinium poison content with passive interrogation. The FNCL-FIFA modal was benchmarked with simulation-based data and a user-friendly GUI was added earlier this year. Three separate codes have been submitted to the LLNL ESW system for review prior to their transfers. These include the Predictive Modeling Response toolkit, GMM-PSD firmware beta version, and the FNCL-FIFA analysis package with GUI and user documentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Pixel Anomaly Detection Tool : a user-friendly GUI for classifying detector frames using machine-learning approaches

Data collection at X-ray free electron lasers has particular experimental challenges, such as continuous sample delivery or the use of novel ultrafast high-dynamic-range gain-switching X-ray detectors. This can result in a multitude of data artefacts, which can be detrimental to accurately determining structure-factor amplitudes for serial crystallography or single-particle imaging experiments. Here, a new data-classification tool is reported that offers a variety of machine-learning algorithms to sort data trained either on manual data sorting by the user or by profile fitting the intensity distribution on the detector based on the experiment. This is integrated into an easy-to-use graphical user interface, specifically designed to support the detectors, file formats and software available at most X-ray free electron laser facilities. The highly modular design makes the tool easily expandable to comply with other X-ray sources and detectors, and the supervised learning approach enables even the novice user to sort data containing unwanted artefacts or perform routine data-analysis tasks such as hit finding during an experiment, without needing to write code.

47 OTHER INSTRUMENTATION↗

Surrogate-Based Robust Design for a Non-Smooth Radiation Source Detection Problem

In this paper, we develop and numerically illustrate a robust sensor network design to optimally detect a radiation source in an urban environment. This problem exhibits several challenges: penalty functionals are non-smooth due to the presence of buildings, radiation transport models are often computationally expensive, sensor locations are not limited to a discrete number of points, and source intensity and location responses, based on a fixed number of sensors, are not unique. We consider a radiation source located in a prototypical 250 m × 180 m urban setting. To address the non-smooth properties of the model and computationally expensive simulation codes, we employ a verified surrogate model based on radial basis functions. Using this surrogate, we formulate and solve a robust design problem that is optimal in an average sense for detecting source location and intensity with minimized uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy Gamma Rays from the Milky Way: Three-dimensional Spatial Models for the Cosmic-Ray and Radiation Field Densities in the Interstellar Medium

High-energy γ -rays of interstellar origin are produced by the interaction of cosmic-ray (CR) particles with the diffuse gas and radiation fields in the Galaxy. The main features of this emission are well understood and are reproduced by existing CR propagation models employing 2D galactocentric cylindrically symmetrical geometry. However, the high-quality data from instruments like the Fermi Large Area Telescope reveal significant deviations from the model predictions on few to tens of degrees scales, indicating the need to include the details of the Galactic spiral structure and thus requiring 3D spatial modeling. In this paper, the high-energy interstellar emissions from the Galaxy are calculated using the new release of the GALPROP code employing 3D spatial models for the CR source and interstellar radiation field (ISRF) densities. Three models for the spatial distribution of CR sources are used that are differentiated by their relative proportion of input luminosity attributed to the smooth disk or spiral arms. Two ISRF models are developed based on stellar and dust spatial density distributions taken from the literature that reproduce local near- to far-infrared observations. The interstellar emission models that include arms and bulges for the CR source and ISRF densities provide plausible physical interpretations for features found in the residual maps from high-energy γ -ray data analysis. The 3D models for CR and ISRF densities provide a more realistic basis that can be used for the interpretation of the nonthermal interstellar emissions from the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

MAPPRAISER: A massively parallel map-making framework for multi-kilo pixel CMB experiments

Forthcoming cosmic microwave background (CMB) polarized anisotropy experiments have the potential to revolutionize our understanding of the Universe and fundamental physics. The sought-after, tale-telling signatures will be however distributed over voluminous data sets which these experiments will collect. These data sets will need to be efficiently processed and unwanted contributions due to astrophysical, environmental, and instrumental effects characterized and efficiently mitigated in order to uncover the signatures. This poses a significant challenge to data analysis methods, techniques, and software tools which will not only have to be able to cope with huge volumes of data but to do so with unprecedented precision driven by the demanding science goals posed for the new experiments. A keystone of efficient CMB data analysis is solvers of very large linear systems of equations. Such systems appear in very diverse contexts throughout CMB data analysis pipelines, however they typically display similar algebraic structures and can therefore be solved using similar numerical techniques. Linear systems arising in the so-called map-making problem are one of the most prominent and common ones. In this work we present a massively parallel, flexible and extensible framework, comprised of a numerical library, MIDAPACK, and a high level code, MAPPRAISER, which provide tools for solving efficiently such systems. Here, the framework implements iterative solvers based on conjugate gradient techniques: enlarged and preconditioned using different preconditioners. We demonstrate the framework on simulated examples reflecting basic characteristics of the forthcoming data sets issued by ground-based and satellite-borne instruments, executing it on as many as 16,384 compute cores. The software is developed as an open source project freely available to the community at: https://github.com/B3Dcmb/midapack.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the mean excitation energy of liquid argon

The mean excitation energy (I-value) of liquid argon is a critical input for energy estimation in neutrino oscillation experiments. It is measured to be 199 +4 -5 eV using the range of 402.2 MeV protons from the Fermilab Linac. This compares to the author's recent evaluation of (197 ± 7) eV based on a combination of an oscillator strength distribution analysis, gaseous argon range measurements, sparse stopping power data on solid argon, and an extrapolation of data on the effect of phase from other substances. Using all sources of information, we recommend a value of (198 ± 4) eV for liquid argon, which is significantly higher than 188 eV, from ICRU-37's gaseous argon evaluation, commonly used in Monte Carlo codes such as Geant4.

47 OTHER INSTRUMENTATION↗