Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An artificial intelligence’s interpretation of complex high-resolution in situ transmission electron microscopy data

Complicated nano- and atomic-scale processes with sub-angstrom spatial resolution and millisecond time resolution visualized by in situ transmission electron microscopy (TEM) are often highly dynamical and time consuming to analyze and interpret. Here, we report how variational autoencoders (VAEs) can provide an artificial intelligence’s interpretation of high-resolution in situ TEM data by condensing and deconvoluting complicated atomic-scale dynamics into a latent space with reduced dimensionality. We designed a VAE model with high latent dimensions capable of deconvoluting information from complex high-resolution TEM data. We demonstrate how this model, with high latent dimensions trained on atomically resolved TEM images of lead sulfide (PbS) nanocrystals, is able to capture movements and perturbations of periodic lattices in both simulated and real in situ TEM data. Importantly, the VAE model shows the capability of detecting and deconvoluting dynamical nanoscale physical processes, such as the rotation of crystal lattices and intra-particle ripening during the annealing of semiconductor nanocrystals.

47 OTHER INSTRUMENTATION↗

Novel 2D velocity estimation method for large transient events in plasmas

Dynamics of fast transient events are challenging to be analyzed with high time resolution. Such events can occur in fusion plasmas such as the filaments during edge-localized modes (ELMs). Here, we present a robust method—the spatial displacement estimation—for estimating the displacements of structures with fast dynamics from high spatial and time resolution imaging diagnostics [e.g., gas-puff imaging (GPI)] with sampling time temporal resolution. First, a background suppression method is shown, which suppresses the slowly time-evolving and spatially non-uniform background in the signal. In the second step, a two-dimensional polynomial trend subtraction method is presented to tackle the remaining polynomial order trend in the signal. After performing these pre-processing steps, the spatial displacement of the propagating structure is estimated from the two-dimensional spatial cross-correlation coefficient function calculated between consecutive frames. The method is tested for its robustness and accuracy by simulated Gaussian events and spatially displaced random noise. An example application of the method is presented on propagating ELM filaments measured by the GPI system on the National Spherical Torus Experiment spherical tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced silicon tracking detector developments for the future Electron-Ion Collider

The proposed Electron-Ion Collider (EIC) will operate high-luminosity high-energy electron+proton and electron+nucleus collisions at the collision energies from 20 GeV to 141 GeV to solve several fundamental questions in the high energy and nuclear physics fields. Its instantaneous luminosity can reach 10 33-34 cm -2 s -1 and the bunching crossing rate is around 10 ns. The EIC project has received CD1 approval from the US DOE in 2021 and moves toward the machine design and preparation for construction. To realize various particle measurements with high precision at the future EIC, a low material-budget and high-granularity silicon vertex and tracking detector with fine spatial and momentum resolutions and nearly 4π solid angle coverage is desired. The Monolithic Active Pixel Sensor (MAPS) and AC Coupled Low Gain Avalanche Diode (AC-LGAD) technologies stand out of several advanced technology options for the EIC silicon vertex and tracking detector subsystems. The MAPS technology has advanced features of low material budget, low power consumption, good radiation resistance and fine spatial resolution. The AC-LGAD technology can achieve fast timing resolution. Latest studies and progress of the EIC silicon vertex and tracking detector conceptual design, performance validations in simulation and ongoing MAPS and AC-LGAD R&D will be shown. Furthermore, schedule and plan of the EIC project detector development will be discussed as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Communication Boundaries of Primal-Dual-Based Distributed Energy Resource Management Systems (DERMS)

As the coordination of distributed energy resources becomes more necessary to provide grid services through a distributed energy resource management system (DERMS), studying the communication requirements for successful real-world, low-cost implementation becomes increasingly important. Specifically, this paper studies the necessary communication time resolutions between the different system components for a primal-dual-based DERMS, a highly developed DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Study of Communication Boundaries of Primal-Dual Based Distributed Energy Resource Management Systems (DERMS)

As the coordination of distributed energy re-sources becomes more necessary to provide grid services through a distributed energy resource management system (DERMS), studying the communication requirements for suc-cessful real-world, low-cost implementation becomes increasingly important. Specifically, this paper studies the necessary communication time resolutions between the different system components for a primal-dual-based DERMS, a highly de-veloped DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Study of Communication Boundaries of Primal-Dual Based Distributed Energy Resource Management Systems (DERMS): Preprint

As the coordination of distributed energy resources (DERs) becomes more necessary to provide grid services through a distributed energy resources management system (DERMS), studying the communication requirements for successful real-world low-cost implementation becomes increasingly important. Specifically, this paper studies the needed communication time resolutions between the different system components for a primal-dual based DERMS which is a highly-developed DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Enhancing the Cherenkov over scintillation ratio using dichroic filters in BGO and TlCl for TOF-PET

Abstract The Cherenkov emission in inorganic crystal scintillators has been shown to dramatically improve time resolution for time-of-flight positron emission tomography (TOF-PET) for in slow scintillators with a high refractive index such as bismuth germanium oxide (BGO). This is due to the faster nature of the Cherenkov emission (tens of picoseconds) with respect to scintillation (nanosecond). However, the presence of slower scintillation light and the inability of existing detectors to distinguish between Cherenkov and scintillation make it difficult for BGO to achieve a good CTR for all the detected coincidence events. In this paper, we exploit the difference between the Cherenkov and scintillation emission spectra and use dichroic filters to enhance the Cherenkov over scintillation ratio. Dichroic filters transmit or reflect photons based on their wavelength, with a photon attenuation lower than 10%. We investigate several shortpass and longpass dichroic filters in a single-photon configuration with BGO and find the optimal filter that maximizes the Cherenkov over scintillation ratio. We demonstrate that we can enhance the ratio of Cherenkov to scintillation photons by a factor of 2.17 ± 0.38 by employing a shortpass dichroic filter with a cut-off wavelength of 450 nm for BGO, and by a factor of 2.87 ± 0.40 using a longpass dichroic filter with a cut-on wavelength of 550 nm for iodine/beryllium-doped thallium chloride.

Science & Technology - Other Topics↗

X-ray and γ-ray beam interstellar communication and implications for SETI

The possibility of detecting artificial signals transmitted by alien civilizations via collimated X-ray or gamma-ray beams is investigated. The prospect of using such beams for human communication within the solar system and beyond is also discussed. Detector responses were simulated for input signals and analyzed using relative entropy. For simplicity, all signals were assumed to use on-off keying (OOK) modulation. “Real” signals were generated by taking digital files and sequentially feeding their raw binary data to the detector simulator, the resulting normalized information content of the detector signals was plotted and compared to random noise signals. Since jpeg files contain compressed information, these served as a proxy for artificial alien signals. This showed that there is a clear difference in measured information content between natural and artificial signals, even with relatively poor time resolution in the detector causing the signals to be smeared (dead-time/rise-time intervals many times longer than the duration between signal pulses). It was found that so long as the signal lasts for at least several rise-time/dead-time intervals, the distinction between random and artificial signals is obvious. A space-telescope with high time resolution for searching for such signals is briefly described and its basic requirements are outlined.

43 PARTICLE ACCELERATORS↗

HyPerPy (Hydrogen Extraction and Parabolic Trough Plant Performance Models using Python) [SWR-21-53]

The HyPerPy package consists of three scripts: 1) Model for Hydrogen Tracking in Parabolic Trough Power Plants, 2) Model for Receiver Performance, and 3) Model for Hydrogen Extraction Process. The power plant model (1) tracks hydrogen generation and transport within the circulating heat transfer fluid (HTF) of the power plant. This script is a transient, initial value simulation, in which the hydrogen concentration in the circulating HTF is 0 moles per cubic meter everywhere at time 0 seconds. Hydrogen concentration is calculated at discrete locations within the circulating HTF with 4-second time resolution. During each time step, the change in hydrogen concentration due to hydrogen generation and permeation is calculated for each location according to the local HTF temperature, vessel or piping properties, hydrogen concentration and partial pressure. This model predicts hourly hydrogen concentrations for typical operating days in the spring, summer, fall, and winter seasons. Data is used to create hourly mappings of hydrogen concentrations for a typical operating year. The receiver model (2) uses a 1-hour time step to estimate getter loading and annulus pressure. For each time step, the model uses HTF and ambient temperature data to estimate absorber tube, bellows, and getter temperatures for the time step. In addition, the model uses hourly HTF hydrogen concentrations that are generated by the power plant model (1), and annulus hydrogen pressure from the previous time step. With these data, the model calculates the moles of hydrogen permeating across the absorber tube and bellows during the time step. The net change in moles hydrogen is added or subtracted from the getter loading for the previous time step, and the hydrogen pressure is re-calculated based on getter loading and temperature. The model uses this algorithm to simulate hydrogen permeation and loading 24 hours per day, 365 days per year using seasonal temperature data. The model repeats these calculations for 25 years to create a mapping of receiver getter loading and annulus hydrogen pressure for four seasons of each year. The model for hydrogen extraction (3) estimates hydrogen extraction rates for a specific separation module configuration. The rate depends primarily on membrane area, vacuum pump performance, headspace gas flowrate to the membrane, and headspace gas hydrogen partial pressure. This model has two versions. The steady-state version predicts hydrogen extraction rates when the module is operating in separation mode. The dynamic version predicts hydrogen transfer through the membrane when the module is operating in sensor mode. The steady-state version is used with the plant model (1) to predict hydrogen partial pressures in the power plant when the extraction process is operating.

Glatzmaier, Gregory↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Development of Frequency Estimation Methods for Future Smart Grid

The frequency estimated by the Phasor Measurement Unit (PMU) is a critical index of power system status and supports many smart grid applications. The future smart grid features high penetration of renewables and more fast-moving power electronics inverters but raises challenges to the reliable frequency estimation. This article presents three methods to address these challenges. First, an enhanced zero-crossing algorithm was developed to track the fast-changing frequency in system dynamics. Second, we propose a technology that can tolerate the system transient and suppress the outliers. Third, an algorithm was developed to export high time-resolution frequency estimations with minimum computational effort. All of the proposed methods are realized in hardware and compared with classical frequency estimation methods. The testing results indicate that the proposed methods have excellent performance. They can be used in future PMUs and provide reliable and high time resolution data for smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

Infrared compatible rapid mixer to probe millisecond chemical kinetics

Fast microfluidic mixers are a valuable tool for studying solution-phase chemical reaction kinetics and molecular processes with spectroscopy. However, microfluidic mixers that are compatible with infrared vibrational spectroscopy have seen only limited development due to the poor infrared transparency of the current microfabrication material. We describe the design, fabrication, and characterization of CaF2-based continuous flow turbulent mixers, which are capable of measuring kinetics in the millisecond time window with infrared spectroscopy, when integrated into an infrared microscope. Kinetics measurements demonstrate the ability to resolve relaxation processes with 1 millisecond time resolution, and straightforward improvements are described that should result in sub-100 µs time-resolution.

Instruments & Instrumentation↗

A zone-level occupancy counting system for commercial office spaces using low-resolution time-of-flight sensors

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. In this paper, we present an indoor occupancy counting system using a sparse array of inexpensive, low-resolution, and privacy-preserving time-of-flight sensors. We develop and validate an algorithm for zonal occupancy counting that can deal with multiple people walking underneath the sensors in arbitrary directions, and evaluate the system both in realistic simulations of office spaces and in a real-world installation. Finally, we found that our system has an error rate of around 0.4%, resulting in highly accurate person localization and zone counting using only a few sensors per space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CACTUS: A depleted monolithic active timing sensor using a CMOS radiation hard technology

The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The required time resolution is of the order of tens of picoseconds, with a spatial granularity of the order of 1 mm. A time measurement at this precision level will also be of interest beyond the LHC and beyond high energy particle physics. We present in this paper the first developments towards a radiation hard Depleted Monolithic Active Pixel Sensor (DMAPS), with high-resolution time measurement capability. The technology chosen is a standard high voltage CMOS process, in conjunction with a high resistivity detector material, which has already proven to efficiently detect particles in tracking applications after several hundred of Mrad of irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rare Higgs Processes at CMS and Precision Timing Detector Studies for HL-LHC CMS Upgrade

This thesis describes the search for two rare Higgs processes. The first analysis describes the CMS Run 2 search for $H$ $\rightarrow$ $\mu$$\mu$ decays, with 137.3 fb$^{-1}$ of data at $\sqrt{s}$ = 13 TeV. The analysis targeted four different Higgs production modes: the gluon fusion (ggH), the vector boson fusion (VBF), the Higgs-strahlung process (VH), and the production in association with a pair of top quarks (ttH). Each category used a dedicated machine learning based classifier to separate the signal from the background processes. A combined fit from all these categories saw a slight excess in the data corresponding to 3.0 standard deviations at $M$$_{H}$ = 125.38 GeV, and gave the first evidence for the Higgs boson decay to second-generation fermions. The best-fit signal strength and the corresponding 68% CL interval was found to be +0.17?????? = 1.19 $_{-0.39}^{+0.41}$ (stat)$_{-0.16}^{+0.17}$(syst) at $M$$_{H}$ = 125.38 GeV. The second analysis describes the CMS Run 2 search for 𝐻𝐻 → 𝑏𝑏𝑏𝑏 with highly boosted Higgs bosons. This analysis used a dedicated jet identification algorithm based on graph neural networks (ParticleNet) to identify boosted H→ bb jets. This search targeted the gluon fusion and the vector boson fusion HH production modes, and put constraints on the allowed values of the various Higgs couplings as: 𝜅𝜆 ∈ [−9.9, 16.9] when 𝜅𝑉 = 1, 𝜅2𝑉 = 1; 𝜅𝑉 ∈ [−1.17, −0.79] ∪ [0.81, 1.18] when 𝜅𝜆 = 1, 𝜅2𝑉 = 1; 𝜅2𝑉 ∈ [0.62, 1.41] when 𝜅𝜆 = 1, 𝜅𝑉 = 1. A scenario with 𝜅2𝑉 = 0 was excluded with a significance of 6.3 standard deviations for the first time, when other H couplings are fixed to their SM values. The combined observed (expected) 95% upper limit on the HH production cross section was found to be 9.9 (5.1) × SM. Finally, this thesis also discusses the planned MIP Timing Detector (MTD) upgrade for CMS at the HL-LHC. The MTD will be a time-of-flight (TOF) detector, designed to provide a precision timing information for charged particles using SiPMs + LYSO scintillating crystals, with a time resolution of ∼30 ps. This thesis describes several R&D tests that have been performed for characterizing the sensor properties (time resolution, light yield, etc.) and optimizing the sensor design geometry. This thesis also contains a description of mock test setups for cooling the sensors, since it is known to be an effective way of mitigating the increased dark current rates in the sensors due to radiation damage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗