Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Switchable 1,8-diazabicycloundec-7-ene and 1-hexanol ionic liquid analyzed by liquid ToF-SIMS

Switchable ionic liquids (SWIL) play an important role in green chemistry. Due to the nature of SWIL chemistry, such as air sensitivity and pressure and temperature dependence, it is difficult to characterize SWIL using vacuum-based surface techniques. The fully CO2 loaded and none-loaded DBU and hexanol mixtures, a SWIL system, were analyzed in situ by time-of-flight secondary ion mass spectrometry (ToF-SIMS) coupled with the System for Analysis at the Liquid Vacuum Interface (SALVI), respectively. The DBU/Hexanol/CO2 SWIL was injected into the microchannel before liquid SIMS analysis. Bi3+ primary ion beam was used. The positive and negative spectra of the SWIL chemical components are presented. The characteristic peaks m/z 153 (reduced DBU) in the positive mode and m/z 101 (oxidized hexanol) in negative mode were observed. In addition, ion pair peaks including m/z 253, 319, 305, 451 in the positive mode and m/z 145, 223, 257 in the negative mode are first observed using this approach. These results demonstrate that the SALVI microfluidic reactor enables the vacuum-based surface technique (i.e., ToF-SIMS) for in situ characterization of challenging liquid samples such as ionic liquids.

DBU, hexanol↗

In Situ Characterization of Shewanella oneidensis MR1 Biofilms by SALVI and ToF-SIMS

Bacterial biofilms are surface-associated communities that are vastly studied to understand their self-produced extracellular polymeric substances (EPS) and their roles in environmental microbiology. This study outlines a method to cultivate biofilm attachment to the System for Analysis at the Liquid Vacuum Interface (SALVI) and achieve in situ chemical mapping of a living biofilm by time-of-flight secondary ion mass spectrometry (ToF-SIMS). This is done through the culturing of bacteria both outside and within the SALVI channel with our specialized setup, as well as through optical imaging techniques to detect the biofilm presence and thickness before ToF-SIMS analysis. Our results show the characteristic peaks of the Shewanella biofilm in its natural hydrated state, highlighting upon its localized water cluster environment, as well as EPS fragments, which are drastically different from the same biofilm’s dehydrated state. These results demonstrate the breakthrough capability of SALVI that allows for in situ biofilm imaging with a vacuum-based chemical imaging instrument.

59 BASIC BIOLOGICAL SCIENCES↗

Investigating the Effects of Chemical Gradients on Performance and Reliability within Perovskite Solar Cells with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS), a powerful analytical technique sensitive to all components of perovskite solar cell (PSC) materials, can differentiate between the various organic species within a PSC absorber or a complete device stack. The ability to probe chemical gradients through the depth of a device (both organic and inorganic), with down to 100 nm lateral resolution, can lead to unique insights into the relationships between chemistry in the absorber bulk, at grain boundaries, and at interfaces as well as how they relate to changes in performance and/or stability. In this essay, the technique is described; then, from the literature, several examples of how TOF-SIMS have been used to provide unique insight into PSC absorbers and devices are covered. Finally, the common artifacts that can be introduced if the data are improperly collected, as well as methods to mitigate these artifacts are discussed.

14 SOLAR ENERGY↗

Argon Cluster Sputtering Source for ToF-SIMS Depth Profiling of Insulating Materials: High Sputter Rate and Accurate Interfacial Information

For the first time, the use of an argon cluster ion sputtering source has been demonstrated to perform superiorly relative to traditional oxygen and cesium ion sputtering sources for ToF-SIMS depth profiling of insulating materials. The superior performance has been attributed to effective alleviation of surface charging. A simulated nuclear waste glass, SON68, and layered hole-perovskite oxide thin films were selected as model systems due to their fundamental and practical significance. Our study shows that if the size of analysis areas is same, the highest sputter rate of argon cluster sputtering can be 2-3 times faster than the highest sputter rates of oxygen or cesium sputtering. More importantly, high quality data and high sputter rates can be achieved simultaneously for argon cluster sputtering while this is not the case for cesium and oxygen sputtering. Therefore, for deep depth profiling of insulating samples, the measurement efficiency of argon cluster sputtering can be about 6-15 times better than traditional cesium and oxygen sputtering. Moreover, for a SrTiO3/SrCrO3 bi-layer thin film on a SrTiO3 substrate, the true 18O/16O isotopic distribution at the interface is better revealed when using the argon cluster sputtering source. Therefore, the implementation of an argon cluster sputtering source can significantly improve the measurement efficiency of insulating materials, and thus can expand the application of ToF-SIMS to the study of glass corrosion, perovskite oxide thin films, and many other potential systems.

Environmental Molecular Sciences Laboratory↗

Insights into the histology of planarian flatworm Phagocata gracilis based on location specific, intact lipid information provided by GCIB-ToF-SIMS imaging

Planarian flatworms are known as the masters of regeneration, re-growing an entire organism from as little as 1/279th part of their body. While the proteomics of these processes has been studied extensively, the planarian lipodome remains relatively unknown. In this study we investigate the lipid profile of planarian tissue sections with imaging Time-of-Flight – Secondary-Ion-Mass-Spectrometry (ToF-SIMS). ToF-SIMS is a label-free technique capable of gathering intact, location specific lipid information on a cellular scale. Lipid identities are confirmed using LC-MS/MS. Our data shows that different organ structures within planarians have unique lipid profiles. The 22-carbon atom poly unsaturated fatty acids (PUFAs) which occur in unusually high amounts in planarians are found to be mainly located in the testes. Additionally, we observe that planarians contain various odd numbered fatty acid species that are usually found in bacteria, localized in the reproductive and ectodermal structures of the planarian. An abundance of poorly understood ether fatty acids and ether lipids were found in unique areas in planarians as well as a new, yet unidentified class of potential lipids in planarian intestines. Identifying the location of these lipids in the planarian body provides insights into their bodily functions and, in combination with knowledge about their diet and their genome, enables drawing conclusions about planarian fatty acid processing.

Angerer, Tina B.↗

Quantifying accessible sites and reactivity on titania–silica (photo)catalysts: Refining TOF calculations

It can be difficult to determine the number of active atoms accessible to the fluid phase in mixed oxide catalysts, as required for obtaining true turnover frequencies (TOF). Here, we utilize the selective titration of surface Ti atoms with phenylphosphonic acid (PPA) on TiO 2 –SiO 2 materials to estimate the number of reactant-accessible sites. TiO 2 –SiO 2 composites were synthesized over a range of Ti loadings from grafting of titanocene dichloride (Cp 2 TiCl 2 ) or tetraethoxy orthotitanate (TEOT) on SiO 2 and sol–gel co-hydrolysis of Si and Ti alkoxides. The materials were characterized by DRUV–vis, XRD, BET, and XANES. Despite the significant morphological and electronic differences, materials prepared by Cp 2 TiCl 2 and TEOT yielded a near-constant TOF of 0.14 h -1 (±0.04) across Ti loadings, for benzyl alcohol photooxidation, when normalizing rates by sites titrated by PPA. The fraction of Ti atoms titrated by PPA was strongly dependent on synthesis method and surface density. PPA titration and benzyl alcohol photooxidation may be useful measures of surface accessibility in other supported oxides.

Eaton, Todd R.↗

Femtosecond Laser Desorption Postionization MS vs ToF-SIMS Imaging for Uncovering Biomarkers Buried in Geological Samples

The study of lipid molecular fossils by traditional biomarker analysis requires bulk sample crushing, followed by solvent extraction, and then the analysis of the extract by gas chromatography-mass spectrometry (GC–MS). This traditional analysis mixes all organic compounds in the sample regardless of their origins, with a loss of information on the spatial distribution of organic molecules within the sample. These shortcomings can be overcome using the chemical mapping of intact samples. Spectroscopic techniques such as UV fluorescence or Raman spectroscopy, laser ablation inductively coupled plasma mass spectrometry, and time-of-flight secondary ion mass spectrometry (ToF-SIMS) are among those elemental and molecular mapping techniques. This study employed femtosecond (fs) laser ablation combined with single-photon ionization, a method called fs-laser desorption postionization mass spectrometry (fs-LDPI-MS). In this work, a pulsed ~75 fs, 800 nm laser was used to ablate the geological sample, which was then photoionized after a few microseconds by a pulsed 7.9 eV vacuum ultraviolet laser. An organic carbon-rich geological sample was used for this study to map hydrocarbon biomarkers in sediments that were previously studied by GC–MS. The petrography of this sample was examined by optical and fluorescence microscopy. It is demonstrated here that fs-LDPI-MS combined with petrography for multimodal imaging can expose buried compounds within the sample via in situ layer removal. When used in conjunction with traditional organic geochemical analysis, this method has the potential to determine the spatial distribution of organic biomarkers in geological material. Finally, fs-LDPI-MS imaging data are compared with ToF-SIMS imaging that is commonly used for such studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ToF-SIMS depth profiling of altered glass

Glass and mineral corrosion usually leads to the formation of morphologically and compositionally complex surface layers that can be characterized by various analytical techniques to infer rate control mechanisms. In this study, we investigate the capabilities and limitations of time-of-flight secondary ion mass spectrometry (ToF-SIMS) to better understand chemical processes of glass corrosion. In particular, we focus on the potential impact of the ToF-SIMS ion beam on the distribution of several elements of interest in alteration layers formed on International Simple Glass, a six-oxide reference glass altered in a solution enriched in alkalis and spiked with H 2 18 O. A thin flake of glass partially altered on both sides is analyzed entirely from one side to the other to determine whether atoms weakly bonded to the solid are displaced by the beams. We highlight the beam effect on cations weakly bonded to the silicate network (Li, Na, K, and B, Ca, Cs to a lesser extent) affecting the profile shape of these elements. No impact is observed on 18 O and H, but it is demonstrated that quantification of isotopic ratios is possible only for a limited range of isotopic enrichment.

36 MATERIALS SCIENCE↗

Applying MALDI-TOF MS to resolve morphologic and genetic similarities between two Dermacentor tick species of public health importance

Abstract Hard ticks (Acari: Ixodidae) have been historically identified by morphological methods which require highly specialized expertise and more recently by DNA-based molecular assays that involve high costs. Although both approaches provide complementary data for tick identification, each method has limitations which restrict their use on large-scale settings such as regional or national tick surveillance programs. To overcome those obstacles, the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been introduced as a cost-efficient method for the identification of various organisms, as it balances performance, speed, and high data output. Here we describe the use of this technology to validate the distinction of two closely relatedDermacentortick species based on the development of the first nationwide MALDI-TOF MS reference database described to date. The dataset obtained from this protein-based approach confirms that tick specimens collected from United States regions west of the Rocky Mountains and identified previously asDermacentor variabilisare the recently described species,Dermacentor similis. Therefore, we propose that this integrative taxonomic tool can facilitate vector and vector-borne pathogen surveillance programs in the United States and elsewhere.

Science & Technology - Other Topics↗

Detection Efficiency of a ToF Spectrometer from Heavy-Ion Elastic Recoil Detection

The detection efficiency of a time-of-flight system based on two micro-channel plates (MCP) time zero detectors plus a conventional silicon surface barrier detector was obtained from heavy ion elastic recoil measurements (this ToF spectrometer is mainly devoted to measurements of total fusion cross section of weakly bound projectiles on different mass-targets systems). In this work we have used beams of {sup 7}Li, {sup 16}O, {sup 32}S and {sup 35}Cl to study the mass region of interest for its application to measurements fusion cross sections in the {sup 6,7}Li+{sup 27}Al systems at energies around and above the Coulomb barrier (0.8V{sub B{<=}}E{<=}2.0V{sub B}). As the efficiency of a ToF spectrometer is strongly dependent on the energy and mass of the detected particles, we have covered a wide range of the scattered particle energies with a high degree of accuracy at the lowest energies. The different experimental efficiency curves obtained in that way were compared with theoretical electronic stopping power curves on carbon foils and were applied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The {sup 237}Np(n,f) cross section at the CERN n-TOF facility

The {sup 237}Np(n,f) cross sections have been measured at the n-TOF facility relative to the {sup 235}U and {sup 238}U fission cross sections. The n-TOF spallation neutron source at CERN is characterized by a high intensity flux, an excellent time resolution and an extensive neutron energy range (from eV to GeV). A fast ionization chamber was used as a fission fragment detector with efficiency better than 97%. Preliminary {sup 237}Np(n,f) cross sections have been deduced in the energy range from 20 keV to 10 MeV and are found in good agreement with data from literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative imaging of trace B in Si and SiO{sub 2} using ToF-SIMS

Changes in the oxidation state of an element can result in significant changes in the ionization efficiency and hence signal intensity during secondary ion mass spectrometry (SIMS) analysis; this is referred to as the SIMS matrix effect [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. The SIMS matrix effect complicates quantitative analysis. Quantification of SIMS data requires the determination of relative sensitivity factors (RSFs), which can be used to convert the as measured intensity into concentration units [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. In this manuscript, the authors report both: RSFs which were determined for quantification of B in Si and SiO{sub 2} matrices using a dual beam time of flight secondary ion mass spectrometry (ToF-SIMS) instrument and the protocol they are using to provide quantitative ToF-SIMS images and line scan traces. The authors also compare RSF values that were determined using oxygen and Ar ion beams for erosion, discuss the problems that can be encountered when bulk calibration samples are used to determine RSFs, and remind the reader that errors in molecular details of the matrix (density, volume, etc.) that are used to convert from atoms/cm{sup 3} to other concentration units will propagate into errors in the determined concentrations.

42 ENGINEERING↗

Observation of N-rich solid-electrolyte interphase by ToF-SIMS.

Formation of a stable solid electrolyte interphase (SEI) between lithium electrodes and electrolyte upon multiple charge/discharge cycles is crucial to a long-term lithium-ion battery performance. Addition of LiNO3 to lithium bis (fluorosulfonyl) imide/poly(ethylene oxide) (LiFSI/PEO) electrolyte leads to a durable SEI that is electrically insulating yet highly conductive to Li ions, chemically and electrochemically stable, physically uniform, and mechanically robust. ToF-SIMS was used here in combination with sputtering by a gaseous cluster ion beam (GCIB) to examine how the addition of a small proportion of LiNO3 to the LiFSI/PEO electrolyte affects the SEI composition. Negative ion ToF-SIMS spectra of the cycled samples display an intense m/z 26 peak associated with the SEI. Exact mass assignments and isotopic ratios indicate that this peak should be assigned as (CN-)-C-12, with little to no negative secondary ion signal arising from (LiF-)-Li-7. This CN- signal appears to arise from an N-rich portion of the SEI adjacent to the Li electrode that is depleted in LiF relative to the bulk electrolyte. The dearth of LiF- (and LiF+ from the positive ion spectra) is unexpected because LiF has been identified in the SEI in similar samples. Finally, GCIB sputtering indicates that the SEI adheres more strongly to the Li electrode than to the LiFSI/PEO electrolyte.

Shavandi, Seyedeh Reyhaneh↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

Applications and limitations of constrained high-resolution peak fitting on low resolving power mass spectra from the ToF-ACSM

The applicability, methods and limitations of constrained peak fitting on mass spectra of low mass resolving power ( m /Δ m 50 ~500) recorded with a time-of-flight aerosol chemical speciation monitor (ToF-ACSM) are explored. Calibration measurements as well as ambient data are used to exemplify the methods that should be applied to maximise data quality and assess confidence in peak-fitting results. Sensitivity analyses and basic peak fit metrics such as normalised ion separation are employed to demonstrate which peak-fitting analyses commonly performed in high-resolution aerosol mass spectrometry are appropriate to perform on spectra of this resolving power. Information on aerosol sulfate, nitrate, sodium chloride, methanesulfonic acid as well as semi-volatile metal species retrieved from these methods is evaluated. The constants in a commonly used formula for the estimation of the mass concentration of hydrocarbon-like organic aerosol may be refined based on peak-fitting results. Lastly, application of a recently published parameterisation for the estimation of carbon oxidation state to ToF-ACSM spectra is validated for a range of organic standards and its use demonstrated for ambient urban data.

47 OTHER INSTRUMENTATION↗

Elemental, Isotopic, and Organic Analysis on Mars with Laser TOF-MS

The in-depth landed exploration of Mars will require increasingly sophisticated robotic analytical tools for both in situ composition science [1] and reconnaissance for sample return [2]. Beyond dust, rock surfaces, and topsoil, samples must be accessed within rocks and ice, well below surface soil, and possibly in elevated deposit layers. A range of spatial scales will be studied, and for the most information-rich microscopic analyses, samples must be acquired, prepared, and positioned with high precision. In some cases samples must also be brought into a vacuum chamber. After expending such resources, it will be important to apply techniques that provide a wide range of information about the samples. Microscopy, mineralogy, and molecular/organic, elemental, and isotopic analyses are all needed, at a minimum, to begin to address the in situ goals at Mars. These techniques must work as an efficient suite to provide layers of data, each layer helping to determine if further analysis on a given sample is desired. In the spirit of broad-band and efficient data collection, we are developing miniature laser time-of-flight mass spectrometers (TOF-MS) for elemental, isotopic, and molecular/organic microanalysis of unprepared solid samples. Laser TOF-MS uses a pulsed laser to volatilize and ionize material from a small region on the sample. The laser energy and focus can be adjusted for atomic and molecular content, sampling area, and depth. Ions travel through the instrument and are detected at a sequence of times proportional to the square root of their mass-to- charge ratios. Thus, each laser pulse produces a complete mass spectrum (in less than 50 microseconds). These instruments can now be significantly miniaturized (potentially to the size of a soda can) without a loss in performance. This effort is reviewed here with an emphasis on applications to Mars exploration.

Brinckerhoff, W. B.↗

Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS

A modified ion-detector/data-acquisition system has been devised to increase the dynamic range of a time-of-flight mass spectrometer (TOF-MS) that, previously, included a microchannel-plate detector and a data-acquisition system based on counting pulses and time-tagging them by use of a time-to-digital converter (TDC). The dynamic range of the TOF-MS was limited by saturation of the microchannel plate detector, which can handle no more than a few million counts per second. The modified system includes (1) a combined microchannel plate/discrete ion multiplier and (2) a hybrid data-acquisition system that simultaneously performs analog current or voltage measurements and multianode single-ion-pulse-counting time-of-flight measurements to extend the dynamic range of a TDC into the regime in which a mass peak comprises multiple ions arriving simultaneously at the detector. The multianode data are used to determine, in real time, whether the detector is saturated. When saturation is detected, the data-acquisition system selectively enables circuitry that simultaneously determines the ion-peak intensity by measuring the time profile of the analog current or voltage detector-output signal.

Burton, William D., Jr.↗

ToF-SIMS Investigation of the Effectiveness of Acid-Cleaning procedures for Genesis Solar Wind Collectors

ToF-SIMS images of Genesis sample surfaces contain an incredible amount of important information, but they also show that the crash-derived surface contamination has many components, presenting a challenge to cleaning. Within the variability, we have shown that there are some samples which appear to be clean to begin with, e.g. 60471, and some are more contaminated. Samples 60493 and 60500 are a part of a focused study of the effectiveness of aqua regia and/or sulfuric acid cleaning of small flight Si implanted with Li-6 using ToF-SIMS.

Goreva, Y. S.↗