Search NASA⌕ Search

SEARCH · Search NASA

Results for “TURBINES, GAS - PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Experimental and Numerical Study on the Effect of Annular Combustor Design on Thermal Uniformity Jet in Crossflow

Abstract Non-uniformity of the exit flow temperature represents one of the significant damages to gas-turbine components, particularly turbine blades. This may occur in the course of gas-turbine operation. This paper aims to provide passive techniques by modifying the combustor design rather than changing the flow parameters to improve the thermal uniformity and turbine blades to reduce thermal stresses and increase turbine blades’ life span. An acceptable agreement between the numerical and experimental results has been achieved, and the agreement includes the velocity and temperature profile. Four different angles have been tested numerically and experimentally with a maximum error of 5% at two different Reynolds numbers. Designing the outer combustor surface with a 45-deg angle bend can give a more uniform temperature distribution of 37% higher than the basic design with only a 0.5% higher pressure drop.

Energy & Fuels↗

Large Eddy Simulation of Externally Induced Ingress about an Axial Seal by Stator Vanes

Turbine inlet temperatures in advanced gas turbines could be as high as 2000 °C. To prevent ingress of this hot gas into the wheelspace between the stator and rotor disks, whose metals can only handle temperatures up to 850 °C, rim seals and sealing flows are used. This study examines the abilities of large eddy simulation (LES) based on the WALE subgrid model and Reynolds-averaged Navier–Stokes (RANS) based on the SST model in predicting ingress in a rotor–stator configuration with vanes but no blades, a configuration with experimental data for validation. Results were obtained for an operating condition, where the ratio of the external Reynolds number to the rotational Reynolds number is 0.538. At this operating condition, both LES and RANS were found to correctly predict the coefficient of pressure, C p , located downstream of the vanes and upstream of the seal, but only LES was able to correctly predict the sealing effectiveness. This shows C p by itself is inadequate in quantifying externally induced ingress. RANS was unable to predict the sealing effectiveness because it significantly under predicted the pressure drop in the hot gas path along the axial direction, especially about the seal region. This affected the pressure difference across the seal in the radial direction, which ultimately drives ingress.

42 ENGINEERING↗

Reducing NOx Emissions in Ammonia Combustors

Ammonia continues to attract growing interest as a carbonneutral replacement fuel, motivating numerous research efforts toward understanding fundamental ammonia combustion characteristics. A major challenge for the use of ammonia is the development of combustor technologies for mitigating potentially high NOx emissions from the fuel-bound nitrogen chemical pathways to acceptable levels. Our work focuses on a staged RQL combustor architecture for minimizing the NOx emission levels through burning fuel-rich in the primary stage to formcombustion products containing significant levels of hydrogen in addition to nitrogen and water with minimal NOx formation. The subsequent quench and burnout stages of the combustor must then quickly burn residual hydrogen with flame-temperatures moderated by nitrogen and water forming in the first stage. Chemical Reactor Network modeling was used to understand and identify optimal stoichiometry and residence times in each stage for minimizing NOx emissions and to quantify pressure and temperature effects. Reducing the overall NOx emissions requires relatively long residence times in the primary stage to achieve near equilibrium NO levels due to kinetically controlling processes. For conditions relevant to gas turbines (e.g., 30 atm), our work indicates that NOx emissions below 20 ppm are theoretically achievable in a staged RQL combustor architecture. However, these emission predictions significantly depend on the accuracies of currently available chemical kinetic mechanisms which have not been extensively validated under elevated pressure and temperature conditions relevant to gas turbines.

10 SYNTHETIC FUELS↗

Cyber-Physical Reformer Development at NETL

Integrated energy systems are considered one of promising technologies to provide efficient, reliable and resilient power generation. The U.S. Department of Energy, National Energy Technology Laboratory is building an automated reformer-solid oxide fuel cell-gas turbine integrated energy system using a cyber-physical systems (CPS) approach, which exploits the advantage of both numerical model and physical system, as well as gapping the inaccessible technologies. Both the fuel reformer and the fuel cell stack are designed to be CPS components, of which the hardware representations are physically integrated with the gas turbine. A compact design is used with the consideration of future commercialization by placing all components inside of a pressure chamber, which is pressurized by the compressor discharge. (Presented virtually at the MILLENNIUM CLEAN and SUSTAINABLE POWER Workshop 2025)

cyber-physical↗

An Assessment of Kinetic Models for Ammonia Flame Extinction

The growing interest in using ammonia as a carbon-neutral replacement fuel has prompted numerous recent research efforts towards understanding fundamental combustion characteristics and chemical kinetics of ammonia oxidation. Despite these recent efforts, there remains a large deficiency in extinction limit data for ammonia flames, particularly under elevated pressure and temperature conditions relevant to gas turbines. Even the literature reaction mechanisms developed specifically for ammonia have been untested under gas turbine relevant conditions, and existing kinetic models have shown large variations in laminar flame speed, extinction strain rate, and speciation predictions for NH3–H2 mixtures at ambient conditions. Recent work by Thomas and co-workers, for example, compared different ammonia kinetic models in the literature for predicting their extinction strain rate measurements for non-premixed NH3-H2 counterflow flames, and again have highlighted the discrepancies in model predictions. Here, our work has undertaken to further highlight important reaction pathways for ammonia oxidation that may be responsible for these discrepancies for extinction strain rate predictions, as well as elucidate sensitive reaction steps with large uncertainties that require further attention. This work points to a need for an improved understanding of ammonia combustion chemistry as well as new datasets at elevated pressure and temperature conditions to better constrain rate expressions for key reaction steps.

ammonia, flame, combustion, kinetic, kinetics↗

Partial Premixing Effects on the Reacting Jet of a High-Pressure Axially Staged Combustor

The effects of partial premixing on a reacting jet-in-crossflow is investigated in a five atmosphere axially staged combustor at stationary gas turbine relevant conditions. The facility consists of a dump style headend burner that provides a crossflow with a quasi-uniform velocity and temperature profile to the axial stage to isolate the effects of the jet-in-crossflow. The headend burner is run with methane and air at a lean equivalence ratio to match industry emission standards. For this work, the total air to the headend and axial stage is kept constant, and fuel is split between the headend and axial stage to represent different gas turbine loading conditions. For the cases analyzed, the fuel split to the axial stage went up to 25%. The axial stage consists of an optically accessible test section with a coaxial injector that provides variability to how long the methane and air can mix before entering the facility. Three different premixed levels are studied: fully premixed, nonpremixed, and partially premixed. The flow-field characteristics of the reacting jet-in-crossflow are analyzed using particle image velocimetry (PIV), and flame behavior is quantified by employing CH* chemiluminescence. NO measurements are made at the exit of the facility using a Horiba emissions analyzer. Furthermore, two different flames are observed: flames that burn in the leeward recirculation region and flames that burn at the core of the jet.

03 NATURAL GAS↗

Laminar burning speed measurements for hydrogen enhanced natural gas in a spherical chamber

This work presents laminar burning speed measurements for natural gas and hydrogen enhanced natural gas in gas-turbine conditions using a spherical combustion chamber at an initial temperature and pressure of 296 K and 10 atm, respectively. Natural gas and hydrogen fuels were prepared and mixed with a synthetic air mixture comprised of oxygen, nitrogen, and helium. The experimental data collected during 10 atm ignition was used to predict the LBS at elevated pressures (30 bar) to approach gas-turbine operating conditions. A significant enhancing effect of combustion pressure on LBS was observed, as well as H2 dilution. This work provides fundamental combustion data relevant to sustainable fuels to reduce economic dependence on carbon-based fossil fuels and reduce anthropogenic climate effects through 2050.

Yovino, Louis↗

Characterizing Flow Instabilities During Transient Events in the Turbine Rim Seal Cavity

Abstract Gas turbine engine design requires considerations not only for long-term steady operation but also for critical transient events. Aircraft engines undergo significant stress during takeoff and landing, while power generation turbines must be flexible for hot restarts as renewable energy sources come online and offline. During these transient cycles, engines sustain wear and degradation that can lead to a reduction in the lifespan of their components and more frequent, costly maintenance. Cooling flows are often used to mitigate these effects, but can lead to complex and problematic flow interactions. This study uses high-frequency response pressure probes and heat flux gauges in the rim seal cavity of a one-stage research turbine to characterize the properties of large-scale flow structures during transient operation. A continuous-duration turbine testing facility provides the ability to assess the importance of these transients by first reaching steady-state operation before imposing transient behaviors. Although previous studies have conducted similar measurements for steady purge flows and wheel speeds, varying these parameters to simulate transient effects revealed several unique phenomena not identifiable with discrete steady measurements. The measurement approach connects the varied transient parameter to the behavior of the flow structures to enable a better understanding of the type of instability observed and the root cause of its formation. In particular, a relationship between instability cell formation and rim sealing effectiveness was identified using experimental data and was supported through computational simulations.

Engineering↗

Multi-physics Peridynamic Modeling of Damage Processes in Protective Coatings

Protective coatings can revolutionize the aerospace industry by providing a way to build a fuel-efficient and low-emission gas turbine engine operating at elevated temperature. Currently, significant challenges persist in the multi-physics modeling of damage processes in protective coatings exposed to the hot corrosive environment of gas turbine engine. Examples of such detrimental processes include an interface damage between different material layers forming protective coating, a formation of the through-the-thickness vertical cracks, a diffusion of oxygen and moisture through those cracks, an oxidation, and a delamination. In this paper, a feasibility of a multi-physics peridynamic model to provide insight to these detrimental processes has been demonstrated. 3-Dimensional peridynamic equations which are valid everywhere, including dynamically evolving discontinuities, have been presented. In conclusion, validation and demonstration have been shown for conduction heat transfer, reactive oxidation, and delamination of protective coating with a composition borrowed from the open literature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extending the Operating Envelope for an Extremely Low NOx Axial Stage Combustion System

The overall goal of this program is to develop a low NOx combustion system which enables a gas turbine combined cycle efficiency of > 65%. The proposed combustion system is a combination of three advanced technologies under development by the Recipient: advanced transition design, the Distributed Combustion System (DCS), and advanced head end. Of note is that the DCS and advanced transition were initially developed with DOE funding under previous Cooperative Agreements. The continued development of these designs has resulted in a proof of concept design which was successfully tested in the Recipient’s state-of-the-art high-pressure rig. The initial rig testing indicated a substantial benefit with respect to high firing temperature operation as well as low NOx operation for the advanced transition and the DCS. Even lower NOx and higher firing temperatures are possible with the addition of the advanced head end to the design. Potential hurdles to the combustion design have been identified, such as high pressure drop and acoustics. The goal of this program is to develop variations of this design which address these hurdles and create an optimized design for implementation into the Recipient’s new high efficiency gas turbine engine.

03 NATURAL GAS↗

Apparatus and process of retrofitting a combined cycle power plant

A process for retrofitting an electric power plant that uses two 60 Hertz large frame heavy duty industrial gas turbine engines to drive electric generators and produce electricity, where each of the two industrial engines can produce up to 350 MW of output power. The process replaces the two 350 MW industrial engines with one twin spool industrial gas turbine engine that is capable of producing at least 700 MW of output power. Thus, two prior art industrial engines can be replaced with one industrial engine that can produce power equal to the two prior art industrial engines.

20 FOSSIL-FUELED POWER PLANTS↗

Finite-rate entrainment effects on nitrogen oxide (NO x ) emissions in staged combustors

Axially staged combustors offer the potential for achieving low NO x emissions from gas turbines at the elevated temperatures required to achieve at least 65% combined cycle efficiencies. While there is evidence that premixing between the main burner products and secondary stream reduces NO x , it is important to characterize the specific requirements needed to achieve low emissions at gas turbine conditions. This study examines the sensitivity of NO x to finite-rate, large-scale entrainment of the main and secondary streams under the simplifying assumption of infinitely-fast small-scale mixing. Essentially, this allows us to isolate the effects of limited large-scale entrainment rates by using a homogeneous/uniform condition for the entrained and reacting gases. We use a reduced-order reactor network model to examine a generic staged-combustor whose inputs are physical time scales that embody the finite-rate entrainment characteristics. With simulations conducted over a large parameter space at typical operating conditions (25 atm, 650 K air), the results show that, even when small-scale mixing is infinitely fast and the reaction zone is uniform, entrainment significantly affects NO x emissions due to its influence on the equivalence ratio — and thus the temperature and time — at which the entrained mixture ignites. Fuel-air staging is shown to be vital to NO x reduction in most practical cases where entrainment times exceed roughly 1 ms and the secondary stream finishes entraining before the main burner products. A constrained NO x minimization indicates that using the leanest possible main burner and re-routing as much air as possible to the secondary stage is key to low NO x with finite-rate entrainment; for example, less than 10 ppm NO x can be achieved if the secondary stage contains 20% of the total mass flow.

03 NATURAL GAS↗

Positive Power with Negative Emission Flexible NGCC Enable by Modular Direct Air Capture (Final Report)

The primary project objective was to synthesize a retrofit design of a natural gas combined cycle plant (Fseries gas turbines in 2x1 configuration) to integrate post-combustion (PCC) and direct air carbon capture (DAC) systems that could produce power with negative emissions across a wide range of loads, see table below. The IP-LP crossover and LP steam system of the NGCC were reconfigured to enable 97% CO2 capture in the PCC system at all loads, and heat integration with the DAC reduced the parasitic load of carbon capture by recovering the heat of condensation of the steam. Similar results were found for Hseries gas turbines.

03 NATURAL GAS↗

Challenges in Kinetic modeling of ammonia pyrolysis

Ammonia pyrolysis reactions have implications for its ignition and oxidation in engines and gas turbines. In the present work, the chemistry of ammonia pyrolysis is investigated by kinetic modeling and theory. Rate constants for key reactions are carefully evaluated based on available experimental and theoretical results. The high pressure limit k1,∞ for NH 2 + H (+M) ⇄ NH 3 (+M) (R1) is calculated to be essentially the collision frequency, indicating that dissociation of ammonia in combustion processes will be at or close to the low pressure limit even at engine and gas turbine conditions. The chemical kinetic model is validated against reported shock tube measurements of NH 3 , NH 2 , and NH in ammonia pyrolysis. Predictions are in good agreement with observations for dilute conditions (≤ 0.5% NH 3 ), but the model appears to underpredict the NH 3 consumption rate at longer times in less dilute mixtures. At short reaction times, thermal dissociation of NH3, together with the NH 3 + H reaction, controls conversion. At longer times, secondary reactions involving NH 2 and NH become important due to their impact on the radical pool. Predictions become sensitive to formation and consumption of diazene (tHNNH and cHNNH). Several of the key steps in the ammonia pyrolysis mechanism are radical-radical reactions that are difficult to measure accurately and challenging to calculate theoretically, and a more comprehensive experimental characterization is desirable to support further model development.

10 SYNTHETIC FUELS↗

Characterization of Heat Transfer in a Trapped-Vortex Combustor Designed for High-Temperature Material Testing

Next generation gas turbines will reduce carbon emissions by improving their cycle efficiencies and implementing hydrogen as a low-carbon fuel. The combined-cycle efficiency can be improved by increasing the combustor outlet temperature and decreasing the cooling air required for hot-section parts. Ultra-high temperature ceramic matrix composites (CMC) can survive increasingly extreme environments due to their strong mechanical properties at expected conditions. The introduction of CMCs in high-hydrogen flame environments requires testing at realistic conditions that mimic the thermochemical and fluid mechanic states in gas-turbine combustors. In this work, we describe a new experiment that has been designed to test high-temperature materials in a combustor-relevant environment. Its trapped-vortex combustor chamber design allows for high levels of fuel flexibility and wide flame stability limits. Testing of monolithic silicon carbide (SiC) samples in this environment was done to characterize the heat transfer to material samples over a wide range of operating conditions, including variations in fuel composition and thermal power. Heat flux measurements were verified in non-reacting and reacting environments after which they were benchmarked with previous literature to verify the operation of the facility with heated air. Testing in combustor-relevant conditions shows high levels of heat flux to the material samples in the combustor, particularly downstream of the anchored flame.

Richins, Porter [Pennsylvania State University , ,↗

Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CRADA 2022-03 Final Report: Advanced Bearing Materials for Harsh Service Conditions

Develop advanced bearing materials for hydrogen gas turbines and wind turbines. Two candidate materials have been selected based on Ames lab’s recent work on high entropy alloys and shape memory alloys. These materials are designed to exhibit a balance of hardness, strength, toughness, and corrosion resistance. The hydrogen diffusion coefficient in the NiTi based shape memory alloy is two order of magnitude lower than that of the conventional case hardened bearing steel. We plan to atomize these materials into powders, additive manufacture cylindrical bearings, then test these bearing for rolling-contact fatigue, corrosion properties, and hydrogen embrittlement. We are a vertically integrated team comprises of national labs, bearing manufacturers, raw material powders makers, and aircraft gas turbine manufacturer.

Argibay, Nicolas [Ames Laboratory (AMES), Ames, IA↗

Front-End Engineering Design for Piperazine with the Advanced Stripper

This Department of Energy (DOE) funded project was executed with the goal of preparing a Front-End Engineering Design (FEED) for the capture and compression of 90% of the CO2 that would normally be emitted from an existing natural gas combined cycle (NGCC) plant. The FEED focused on the application of the piperazine advanced stripper (PZAS) process at Mustang Station of the Golden Spread Electric Cooperative (GSEC), which consists of two gas turbines with common heat recovery steam generator (HRSG). The University of Texas at Austin (UT) served as the prime contractor, and subcontracted AECOM Technical Services and Trimeric Corporation to support FEED development. This project team has worked together to advance PZAS for more than a decade. ExxonMobil, Chevron, and Total provided project co-funding. The objectives of this work included: 1. To advance engineering design such that a comprehensive estimate for the total installed cost of a full-scale PZAS CO2 Capture Plant with CO2 compression can be developed on an existing NGCC power plant. a. These detailed costs can also be used to qualify PZAS and other related second generation (2G) amine scrubbing processes for use on cogeneration facilities in refineries and chemical plants that use gas turbines with HRSGs to produce steam. b. These detailed costs will help qualify 2G amine scrubbing for use on NGCC power plants and establish a more accurate baseline cost to be used as a target by other capture technologies. 2. To provide cost details to be used in the economic optimization of the process features of PZAS and other 2G amine scrubbing processes. 3. To provide DOE with a more detailed understanding of carbon capture costs in a commercial application, enabling DOE to better design its R&D program to improve the economics for carbon capture. 4. To provide the host site and cost share partners with the information necessary to determine whether a commercial project to capture and use CO2 for enhanced oil recovery (EOR) or for sequestration can be justified (when accounting for the 45Q tax credit). A key component of the FEED is the estimated total installed cost, which provides a basis for the likely capital investment necessary to implement the PZAS carbon capture process at this location and scale. In combination with the included economic analysis, which accounts for potential revenue from the produced CO2, potential avenues to profitability are explored. The major findings of the FEED are as follows: The Mustang Station PZAS CO2 Capture Plant estimated total project cost of $698 MM of which $384 MM was direct costs. The annual operating costs were $32.6 MM. The total investment for a PZAS facility at Mustang Station is $725 MM. This estimate includes owner’s cost of $25 million and a contingency of $110 MM. • The study estimated the CO2 capture plant at Mustang Station would generate CO2 at $110/tonne for EOR, assuming a 12% IRR (internal rate of return) and an 85% capacity factor. For CO2 storage, the same case would achieve a 12% IRR at about $114/tonne. At a capacity factor of 52%, the storage and EOR cases would break even when carbon is priced ~$150/tonne. The economic analysis determined that the capacity factor and utility pricing, among other variable factors, had a significant effect on the economics and will need additional studied. • The energy penalty of the PZAS plant would be about 46 MW in connected power and 35 MW in operating load. The natural gas requirement (for the Gas Boiler package) would be about 354 MMBTU/hr. • The FEED revealed no major risks in process maturity. However, some areas were outlined for further engineering during detailed design, which included the Gas Boiler system, general arrangement and site layout, air coolers, schedule development, and optimization of the process for higher CO2 removal. • If PZAS were to be implemented at another host site, additional opportunities for cost reduction for would include cost reduction through use of cooling water and steam extraction.

03 NATURAL GAS↗