Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurement of Groove Features and Dimensions of the Vertical Test Cathode and the Choke Joint of the Superconducting Electron Gun Cavity of the Energy Recovery LINAC

A testing program for the superconducting electron gun cavity that has been designed for the Energy Recovery LINAC is being planned. The goal of the testing program is to characterize the RF properties of the gun cavity at superconducting temperatures and, in particular, to study multipacting that is suspected to be occurring in the choke joint of the cavity where the vertical test cathode is inserted. The testing program will seek to understand the nature and cause of this multipacting and attempt to eliminate it, if possible, by supplying sufficient voltage to the cavity. These efforts are motivated by the multipacting issues that have been observed in the processing of the fine-grain niobium gun cavity. This cavity, which is being processed at Thomas Jefferson National Laboratory for Brookhaven, has encountered multipacting at a gradient of approximately 3 MV/m and, to date, has resisted efforts at elimination. Because of this problem, a testing program is being established here in C-AD that will use the large-grain niobium gun cavity that currently resides at Brookhaven and has been used for room-temperature measurements. The large-grain and fine-cavities are identical in every aspect of construction and only differ in niobium grain size. Thus, it is believed that testing and conditioning of the large-grain cavity should yield important insights about the fine-grain cavity. One element of this testing program involves characterizing the physical features of the choke joint of the cavity where the multipacting is believed to be occurring and, in particular the grooves of the joint. The configuration of the cavity and the vertical test cathode is shown in Figure 1. In addition, it is important to characterize the groove of the vertical test cathode. The grooved nature of these two components was specifically designed to prevent multipacting. However, it is suspected that, because of the chemical processing that the fine-grain gun cavity underwent along with the vertical test cathode, the geometry of these grooves was altered, presenting the possibility that multipacting may, in fact, be occurring in this area and contributing to the low gradients that have been observed in the fine-grain cavity. Therefore, the Survey and Alignment group in C-AD engaged in measurements of the cavity joint, shown in Figure 2 and the cathode weldment, shown in Figure 3 for the purpose of characterizing the grooves in both the cavity and the vertical test cathode and comparing the dimensions of the cathode with those of the prints supplied by Advanced Energy Systems (AES), the original designer and manufacturer of both the test cathode and the electron gun cavity, in preparation to have a new one manufactured. The goal was to ensure that the articles as built matched the design prints in preparation for manufacturing a new vertical test cathode. This report describes the data collected by the Survey group in these efforts. The endeavor was challenging for the group given the millimeter-scale dimensions of the grooves and the requirement for high precision.

43 PARTICLE ACCELERATORS↗

1000–ton testing machine for cyclic fatigue tests of materials at liquid nitrogen temperatures

One of the main tasks of superconductive magnets R and D is to determine the mechanical and fatigue properties of structural materials and the critical design elements in the cryogenic temperature range. This paper describes a new facility built based on the industrial 1000-ton (10 MN) testing machine Schenk PC10.0S. Special equipment was developed to provide the mechanical and cyclic tensile fatigue tests of large-scale samples at the liquid nitrogen temperature and in a given load range. The main feature of the developed testing machine is the cryostat, in which the device converting a standard compression force of the testing machine to the tensile force affected at the test object is placed. The control system provides the remote control of the test and obtaining, processing and presentation of test data. As an example of the testing machine operation the test program and test results of the cyclic tensile fatigue tests of fullscale helium inlet sample of the PF1 coil ITER are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Testing in the Secure Transport of Nuclear, Radiological, and other High-Risk Materials

A long established methodology for determining the effectiveness of an overall physical protection system (PPS) is through a healthy and robust performance testing program. Performance tests are vital because they provide essential information used in the determination of asset risk and the analysis of protection effectiveness. By establishing and verifying detection, assessment, response, interruption, and neutralization data, one can determine baseline protection effectiveness and consider upgrade scenarios and improving effectiveness. Performance testing also addresses the needs of multiple stakeholders, including the vulnerability assessment teams, site/facility personnel, and safety, and provides management with an independent, objective assessment of overall physical protection systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Leak Testing with Simulated Waste of Hanford Tank Farm Valves Utilized for Double Valve Isolation - 16108

The existing Hanford Tank Farms Waste Transfer System has several models of ball valves used for double valve isolation (DVI) that have been installed for 10 or more years. The safety function of the safety-significant valves is to limit leakage of waste past the valves in order to decrease the consequences of a fine spray release due to a transfer misroute. While previous leak testing of the valves has been conducted, the testing did not address concerns in the Documented Safety Analysis concerns about the impact on valve operation and service life of the potential abrasive/erosive properties of the tank waste on the valves when cycled. Pacific Northwest National Laboratory (PNNL) conducted DVI tests at their Multi-Phase Transport Evaluation Loop Facility. Testing evaluated the leak rate of safety-significant isolation valves for DVI as a function of simulated operating cycles. PNNL developed a performance-based simulant specifically for this test program. The test environment simulated the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during single-shell tank retrieval and waste feed delivery to the Hanford Tank Waste Treatment and Immobilization Plant. The testing consisted of periodically measuring leak rates and maximum operational torques on the DVI valves after prescribed numbers of valve operational cycles (open and close). The test results from the simulant cycle tests provide Washington River Protection Solutions with performance characteristics that can be used to verify compliance with the Documented Safety Analysis limits for valve seat leakage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MECHANISTIC UNDERSTANDING OF CAUSTIC CRACKING OF CARBON STEELS

Liquid waste generated by the PUREX process for separation of nuclear materials is concentrated and stored in Type IV single-shell carbon steel tanks at the Savannah River Site (SRS). The Type IV tanks for this waste do not have cooling coils and have not undergone heat treatment to stress-relieve the tanks. After the waste is concentrated by evaporation, it becomes very alkaline and can cause stress corrosion cracking (SCC) and pitting corrosion of the tank materials. SRS has experienced leakage from non-stress-relieved waste tanks constructed of A285 carbon steel and pitting of A212 carbon steel tanks in the vapor space. An investigation of tank materials has been undertaken at SRS to develop a basic understanding of caustic SCC of A285 and A212 grade carbon steels exposed to aqueous solutions, primarily containing sodium hydroxide (NaOH), sodium nitrate (NaNO{sub 3}), and sodium nitrite (NaNO{sub 2}) at temperatures relevant to the operating conditions of both the F and H area plants. This report presents the results of this corrosion testing program. Electrochemical tests were designed using unstressed coupons in a simulated tank environment. The purpose of this testing was to determine the corrosion susceptibility of the tank materials as a function of chemical concentration, pH, and temperature. A285 and A516 (simulates A212 carbon steel) coupons were used to investigate differences in the corrosion of these carbon steels. Electrochemical testing included measurement of the corrosion potential and polarization resistance as well as cyclic potentiodynamic polarization (CPP) testing of coupons. From the CPP experiments, corrosion characteristics were determined including: corrosion potential (E{sub corr}), pitting or breakdown potential (E{sub pit}), and repassivation potential (E{sub prot}). CPP results showed no indications of localized corrosion, such as pitting, and all samples showed the formation of a stable passive layer as evidenced by the positive hysteresis during the scan. Analysis of the CPP data was performed to compare the corrosion susceptibility of the samples under different environmental conditions. Test results indicated that the most important factors affecting corrosion of the steel are the solution temperature, hydroxide concentration, and the material used in constructing the tanks. Variables that did not significantly affect the corrosion susceptibility of the steel were the nitrate or nitrite concentration and the atmosphere in the tank. The passivation current of the coupons increased exponentially with temperature. Longer-term studies of the passivation current are suggested based on results from the literature for iron in highly caustic environments. Polarization resistance studies showed a significant increase in corrosion rate at 125 C and 12 M hydroxide concentration when compared with tests at lower temperatures and lower hydroxide concentrations. Within the temperature and pH range of these tests, iron oxide, Fe{sub 3}O{sub 4}, becomes unstable and could account for the increased corrosion susceptibility. The applicability of these conditions should be confirmed and detailed surface studies should be conducted to determine the corrosion resistance of A285 and A516 carbon steels under these conditions. Surface science studies should also be conducted to determine the role of the carbon steel composition in preventing corrosion under these conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FEASIBILITY STUDY FOR THE DEVELOPMENT OF A TEST BED PROGRAM FOR NOVEL DETECTORS AND DETECTOR MATERIALS AT SRS H-CANYON SEPARATIONS FACILITY

Researchers at the Savannah River National Laboratory (SRNL) have proposed that a test bed for advanced detectors be established at the H-Canyon separations facility located on the DOE Savannah River Site. The purpose of the proposed test bed will be to demonstrate the capabilities of emerging technologies for national and international safeguards applications in an operational environment, and to assess the ability of proven technologies to fill any existing gaps. The need for such a test bed has been expressed in the National Nuclear Security Administration's (NNSA) Next Generation Safeguards Initiative (NGSI) program plan and would serve as a means to facilitate transfer of safeguards technologies from the laboratory to an operational environment. New detectors and detector materials open the possibility of operating in a more efficient and cost effective manner, thereby strengthening national and international safeguards objectives. In particular, such detectors could serve the DOE and IAEA in improving timeliness of detection, minimizing uncertainty and improving confidence in results. SRNL's concept for the H Canyon test bed program would eventually open the facility to other DOE National Laboratories and establish a program for testing national and international safeguards related equipment. The initial phase of the test bed program is to conduct a comprehensive feasibility study to determine the benefits and challenges associated with establishing such a test bed. The feasibility study will address issues related to the planning, execution, and operation of the test bed program. Results from the feasibility study will be summarized and discussed in this paper.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Effects of Intermediate Ethanol Blends on Legacy Vehicles and Small Non‑Road Engines, Report 1 - Updated

In summer 2007, the U.S. Department of Energy (DOE) initiated a test program to evaluate the potential impacts of intermediate ethanol blends on legacy vehicles and other engines. The purpose of the test program is to assess the viability of using intermediate blends as a contributor to meeting national goals in the use of renewable fuels. Through a wide range of experimental activities, DOE is evaluating the effects of E15 and E20--gasoline blended with 15 and 20% ethanol--on tailpipe and evaporative emissions, catalyst and engine durability, vehicle driveability, engine operability, and vehicle and engine materials. This first report provides the results available to date from the first stages of a much larger overall test program. Results from additional projects that are currently underway or in the planning stages are not included in this first report. The purpose of this initial study was to quickly investigate the effects of adding up to 20% ethanol to gasoline on the following: (1) Regulated tailpipe emissions for 13 popular late model vehicles on a drive cycle similar to real-world driving and 28 small non-road engines (SNREs) under certification or typical in use procedures. (2) Exhaust and catalyst temperatures of the same vehicles under more severe conditions. (3) Temperature of key engine components of the same SNREs under certification or typical in-use conditions. (4) Observable operational issues with either the vehicles or SNREs during the course of testing. As discussed in the concluding section of this report, a wide range of additional studies are underway or planned to consider the effects of intermediate ethanol blends on materials, emissions, durability, and driveability of vehicles, as well as impacts on a wider range of nonautomotive engines, including marine applications, snowmobiles, and motorcycles. Section 1 (Introduction) gives background on the test program and describes collaborations with industry and agencies to date. Section 2 (Experimental Setup) provides details concerning test fuels, vehicle and SNRE selection, and test methods used to conduct the studies presented in this report. Section 3 (Results and Discussion) summarizes the vehicle and SNRE studies and presents data from testing completed to date. Section 4 (Next Steps) describes planned future activities. The appendixes provide test procedure details, vehicle and SNRE emissions standards, analysis details, and additional data and tables from vehicle and SNRE tests.

02 PETROLEUM↗

Advanced Reactor Fuels Irradiation Experiment Design Objectives

This report summarizes the objectives of the current irradiation testing activities being undertaken by the Advanced Fuels Campaign relative to supporting the development and demonstration of innovative design features for metallic fuels in order to realize reliable performance to ultra-high burnups. The AFC-3 and AFC-4 test series are nearing completion; the experiments in this test series that have been completed or are in progress are reviewed and the objectives and test matrices for the final experiments in these two series are defined. The objectives, testing strategy, and test parameters associated with a future AFC test series, AFC-5, are documented. Finally, the future intersections and/or synergies of the AFC irradiation testing program with those of the TREAT transient testing program, emerging needs of proposed Versatile Test Reactor concepts, and the Joint Fuel Cycle Study program’s Integrated Recycle Test are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The NOvA Test Beam Program

NOvA is a two-detector long-baseline neutrino oscillation experiment which aims to make a determination of the neutrino mass hierarchy, the octant of ${\theta}_{23}$, and measure possible CP violation. The NOvA Test Beam program consists of a scaled-down NOvA detector placed in a beamline capable of delivering 0.3 - 2.0 GeV/c protons, electrons, pions, and kaons. The beamline detectors provide us with particle identification and momentum measurements so we can study our detector technology with known inputs. Studying these particles will provide us a more detailed understanding of our calibration, detector response, and energy scale, which are some of the largest sources of systematic uncertainty in NOvA analyses. We will also collect a selection of single-particle data events for training particle identification algorithms. I will present the current status of the NOvA Test Beam program and discuss plans for data taking and analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NOvA Test Beam Program

NOvA is a long-baseline oscillation neutrino experiment designed to study and measure a wide range of important topics for neutrino physics such as the neutrino mixing parameters, the neutrino mass hierarchy, and CP violation in the lepton sector. The NOvA Test Beam experiment uses a scaled-down detector of 30 tons to analyze tagged beamline particles. A new tertiary beamline deployed at Fermilab can select and identify electrons, muons, pions, kaons and protons with momenta from 0.2 to 2 GeV/c. Using these data, the Test Beam program will provide NOvA with a better understanding of the largest systematic uncertainties impacting the analyses, including the detector response, calibration, and hadronic and electromagnetic energy resolution. The status and future plans for the NOvA Test beam program, along with preliminary results, are presented in these Proceedings.

43 PARTICLE ACCELERATORS↗

Lessons Learned: Summary of Insights From the HERO WEC and Waves to Water Deployments Between 2022 and 2024

In 2020, a team from the National Renewable Energy Laboratory (NREL) partnered with the East Carolina University Coastal Studies Institute to develop a small, modular, wave-powered point absorber desalination prototype. That prototype, known as the hydraulic and electric reverse osmosis wave energy converter (HERO WEC), was intended to de-risk the installation activities planned for the Waves to Water Prize sponsored by the Water Power Technologies Office. The NREL team was given approximately 18 months to design, build, bench test, and deploy the HERO WEC prototype. Since the initial HERO WEC development, it has been used for two in-lab test programs and three ocean deployments. The first in-lab test program focused on ensuring that the overall operation of the device occurred as expected and on validating the operation of safety systems such as pressure relief valves or electrical breakers for load mitigation. The second in-lab test program was the first time the NREL team leveraged NREL’s large-amplitude motion platform to characterize the performance of the HERO WEC. Of the three in-water deployments, the first deployment was effectively an installation and recovery practice with no meaningful wave activity during the time that it was installed. The second deployment was a 2-week effort that enabled both the electric and hydraulic configurations of the device to be in the water for approximately 5 days each. This deployment was also the first time that the team had the opportunity to perform a drivetrain swap on the Coastal Studies Institute research vessel. The third deployment had to be split into two separate installations due to minor damage incurred from the WEC spinning during the initial installation. This report summarizes the deployments, the challenges encountered with each deployment, and the lessons learned for future work.

16 TIDAL AND WAVE POWER↗

US DOE Regional Test Centers Program - 2016 Annual Report.

The US Department of Energy’s Regional Test Center (RTC) program provides outdoor validation and bankability data for innovative solar technologies at five sites across the US representing a range of climate conditions. Data helps get new technologies to market faster and improves US industry competitiveness. Managed by Sandia National Laboratories and the National Renewable Energy Laboratory (NREL), the RTC program partners with US manufacturers of photovoltaic (PV) technologies, including modules, inverters, and balance-of-system equipment. The study is collaborative, with manufacturers (also known as RTC industry partners) and the national labs working together on a system design and validation strategy that meets a clearly defined set of performance and reliability objectives.

14 SOLAR ENERGY↗

Large-Scale Spray Releases: Additional Aerosol Test Results

One of the events postulated in the hazard analysis for the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak event involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids that behave as a Newtonian fluid. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and in processing facilities across the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are mostly absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale testing. The small-scale testing and resultant data are described in Mahoney et al. (2012b), and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the relevant physical properties projected for actual WTP process streams.

42 ENGINEERING↗

Small-Scale Spray Releases: Additional Aerosol Test Results

One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the relevant physical properties projected for actual WTP process streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of recent tests of GNS transport and storage casks for nuclear waste - 15285

State of the art dimensioning of casks for nuclear waste is changing rapidly in recent years. Therefore even established packages that serve the market for many years have to face new type testing programs that implements changes to its designs. The paper shows some of the recent testing programs for existing packages and provides an outlook to future casks solutions and its testing programs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subcomponent Validation of Composite Joints for Marine Energy Structures

The Marine Energy Advanced Materials project addresses the barriers and uncertainties facing marine renewable energy developers in using composite materials for load-bearing structures. Sponsored by the U.S. Department of Energy's Water Power Technologies Office, the multiyear project comprises of collaborators from the National Renewable Energy Laboratory (NREL), Sandia National Laboratories, Pacific Northwest National Laboratory (PNNL), Montana State University (MSU), Florida Atlantic University (FAU), and industry stakeholders. As part of the Marine Energy Advanced Materials project, marine renewable energy industry surveys and assessments were conducted to identify key materials and knowledge gaps that hinder the adoption of composite materials in marine renewable energy structures. Specific knowledge gaps highlighted for composite materials were environmental effects, fatigue strengths, and bonded and bolted interconnects (composite/composite and composite/metal). It was concluded that many of these gaps could be addressed through subcomponent validation; consequently, a program was developed at NREL with the goals of developing subcomponent validation methods for appropriate marine energy materials, which would improve the understanding of design allowables for full-scale structural components and joints. Ultimately, the aim is to reduce timelines and costs associated with full-scale structural validation efforts while also providing near-net-scale static and fatigue data of composite/metal subcomponents for marine renewable energy systems. To approach these goals, a testing program was developed at NREL to investigate a variety of materials and structural design details at the subcomponent scale to understand (a) the effects of harsh and corrosive marine energy environments and (b) the static and fatigue strengths of the complex geometries. The recent study from this testing program is perhaps the largest that has ever been conducted with respect to specimen scale and geographic diversity of underwater environmental conditions that the specimens were subjected to. A variety of specimen geometries were designed by NREL to highlight key features of multimaterial (composite/composite or metal/composite) interconnects that may be used in marine renewable energy structural designs. The designs used several different composite matrices, adhesives, and marine-grade steels, which were highlighted in the surveys as being the most appropriate for harsh marine environments. Composite panels were then manufactured at MSU, and were subsequently manufactured into test specimens by NREL. The specimens were shipped to FAU and PNNL for conditioning in ocean water tanks at various temperatures for an extended period. The specimens were then returned to NREL for structural validation. This presentation will provide an overview of recent advances within the testing program in terms of specimen design and test methods, and will discuss results and key findings of the subcomponent testing program to date at NREL.

adhesives↗