Flexible approach to vibrational sum-frequency generation using shaped near-infrared light

We describe a new approach that expands the utility of vibrational sum-frequency generation (vSFG) spectroscopy using shaped near-infrared (NIR) laser pulses. Here, we demonstrate that arbitrary pulse shapes can be specified to match experimental requirements without the need for changes to the optical alignment. In this way, narrowband NIR pulses as long as 5.75 ps are readily generated, with a spectral resolution of about 2.5 cm -1 , an improvement of approximately a factor of 3 compared to a typical vSFG system. Moreover, the utility of having complete control over the NIR pulse characteristics is demonstrated through nonresonant background suppression from a metallic substrate by generating an etalon waveform in the pulse shaper. The flexibility afforded by switching between arbitrary NIR waveforms at the sample position with the same instrument geometry expands the type of samples that can be studied without extensive modifications to existing apparatuses or large investments in specialty optics.

36 MATERIALS SCIENCE↗

Use of Photoelastic Modulators for High-accuracy Spectropolarimetric Imaging of Aerosols

Passive multiangular, multispectral, and polarimetric sensing approaches each have unique strengths for the measurement of tropospheric aerosol column abundances and microphysical properties. Current spaceborne multispectral and multiangular aerosols sensors operate at approximately 1 km resolution. Under NASA's Instrument Incubator Program, we are developing an electro-optic imaging approach that will enable adding high-accuracy polarimetry to such observations. To achieve a degree of linear polarization (DOLP) uncertainty of 0.5%, our approach temporally modulates the linear-polarization component of incoming light at a rapid rate, enabling each detector within a focal-plane array, combined with polarization analyzers, to measure the relative proportions of the linear Stokes components Q or U to the total intensity. Our system uses tandem photoelastic modulators (PEMs) within a high-reflectance, low diattenuation camera design. The two PEMs vibrate at slightly different resonant frequencies, leading to modulation of the polarized light at a heterodyne frequency of ~25 Hz. High-speed (1 kHz) readout of the detector arrays samples the output waveforms from which Q/I and U/I are derived. We report on experimental and theoretical analyses of PEM and optical system performance, along with plans for developing ruggedized PEMs capable of withstanding launch and on-orbit stresses.

photoelastics↗

SCEMA: a high channel density electronics module for fast waveform capture

The development of fast, highly pixelated photodetectors with single-photon sensitivity has the potential to enable a variety of new radiation detection concepts. Systems that desire to employ these detectors without loss of information demand waveform digitization with high sampling rates. Switched capacitor arrays provide a low-cost, low-power, compact solution to fast readout with high channel density. The Sandia Laboratories Compact Electronics for Modular Acquisition (SCEMA) was developed to meet these demands. A single module employs two domino ring sampling switched capacitor arrays (DRS4) [1] to provide 16 channels of up to 5 GS/s waveform digitization. This paper presents an overview of the board design and function. Calibration procedures for the module are discussed. Lastly, temporal resolution tests are presented demonstrating the module's viability as readout for high fidelity temporal measurements of single photons in suitable photodetectors.

47 OTHER INSTRUMENTATION↗

Aging Wire Insulation Assessment by Phase Spectrum Examination of Ultrasonic Guided Waves

Wire integrity has become an area of concern to the aerospace community including DoD, NASA, FAA, and Industry. Over time and changing environmental conditions, wire insulation can become brittle and crack. The cracks expose the wire conductor and can be a source of equipment failure, short circuits, smoke, and fire. The technique of using the ultrasonic phase spectrum to extract material properties of the insulation is being examined. Ultrasonic guided waves will propagate in both the wire conductor and insulation. Assuming the condition of the conductor remains constant then the stiffness of the insulator can be determined by measuring the ultrasonic guided wave velocity. In the phase spectrum method the guided wave velocity is obtained by transforming the time base waveform to the frequency domain and taking the phase difference between two waveforms. The result can then be correlated with a database, derived by numerical model calculations, to extract material properties of the wire insulator. Initial laboratory tests were performed on a simple model consisting of a solid cylinder and then a solid cylinder with a polymer coating. For each sample the flexural mode waveform was identified. That waveform was then transformed to the frequency domain and a phase spectrum was calculated from a pair of waveforms. Experimental results on the simple model compared well to numerical calculations. Further tests were conducted on aircraft or mil-spec wire samples, to see if changes in wire insulation stiffness can be extracted using the phase spectrum technique.

Anastasi, Robert F.↗

A minimax technique for time-domain design of preset digital equalizers using linear programming

A linear programming technique is presented for the design of a preset finite-impulse response (FIR) digital filter to equalize the intersymbol interference (ISI) present in a baseband channel with known impulse response. A minimax technique is used which minimizes the maximum absolute error between the actual received waveform and a specified raised-cosine waveform. Transversal and frequency-sampling FIR digital filters are compared as to the accuracy of the approximation, the resultant ISI and the transmitted energy required. The transversal designs typically have slightly better waveform accuracy for a given distortion; however, the frequency-sampling equalizer uses fewer multipliers and requires less transmitted energy. A restricted transversal design is shown to use the least number of multipliers at the cost of a significant increase in energy and loss of waveform accuracy at the receiver.

Vaughn, G. L.↗

Simple quasi-exponential slope generator

Circuitry for digitally generating an exponentially decaying wave function permits discrete values to be sampled from the exponential waveform for comparison with a binary number of specified accuracy. This exponential-decay generator employs a simple binary counter to count in the sequence of exponential decay.

Anderson, T. O.↗

Embedded gage impact study

Impact damage in graphite/epoxy laminates was characterized and transient strain history during impact was correlated. The material investigated was AS-4/3501-6 graphite/epoxy. Eight-ply and sixteen-ply quasi-isotropic laminates of 45/0/-45/90 sub s and 45/0/-45/90 sub 2s layups were fabricated with strain gages embedded between plies during the strain gages and leads from the highly conductive graphite fibers. The specimens were circular plates 12.7 cm (5 in.) in diameter and clamped along their circumference. The specimens were impacted with a 185 gm impactor, dropped from heights of 1.20 m and 1.65 m. An accelerometer was attached to the back surface of the specimen opposite the impact point and was used to trigger the recording instrumentation. The transient strain data were recorded with an eight channel waveform digitizer capable of sampling data at 0.5 microsec intervals. The data were stored, processed, and plotted by means of a microcomputer. Transient strain data were correlated with results from ultrasonic inspection of the specimens.

Schramm, S. W.↗

Interpretable AI forecasting for numerical relativity waveforms of quasicircular, spinning, nonprecessing binary black hole mergers

We present a deep-learning artificial intelligence model (AI) that is capable of learning and forecasting the late-inspiral, merger and ringdown of numerical relativity waveforms that describe quasicircular, spinning, nonprecessing binary black hole mergers. We used the NRHybSur3dq8 surrogate model to produce train, validation and test sets of ℓ = |m| = 2 waveforms that cover the parameter space of binary black hole mergers with mass ratios q ≤ 8 and individual spins |s$^{z}_ {(1,2)}$| ≤ 0.8. These waveforms cover the time range t ∊ [-5000 M, 130 M], where t = 0M marks the merger event, defined as the maximum value of the waveform amplitude. We harnessed the ThetaGPU supercomputer at the Argonne Leadership Computing Facility to train our AI model using a training set of 1.5 million waveforms. We used 16 NVIDIA DGX A100 nodes, each consisting of 8 NVIDIA A100 Tensor Core GPUs and 2 AMD Rome CPUs, to fully train our model within 3.5 h. Our findings show that artificial intelligence can accurately forecast the dynamical evolution of numerical relativity waveforms in the time range t ∊ [-100 M, 130 M]. Sampling a test set of 190,000 waveforms, we find that the average overlap between target and predicted waveforms is ≳99% over the entire parameter space under consideration. We also combined scientific visualization and accelerated computing to identify what components of our model take in knowledge from the early and late-time waveform evolution to accurately forecast the latter part of numerical relativity waveforms. This work aims to accelerate the creation of scalable, computationally efficient and interpretable artificial intelligence models for gravitational wave astrophysics

79 ASTRONOMY AND ASTROPHYSICS↗

LAD-C: A large area debris collector on the ISS

The Large Area Debris Collector (LAD-C) is a 10 sq m aerogel and acoustic sensor system under development by the U.S. Naval Research Laboratory (NRL) with main collaboration from the NASA Orbital Debris Program Office at Johnson Space Center, JAXA Institute of Space and Astronautical Science (ISAS), Chiba University (Japan), ESA Space Debris Office, University of California at Berkeley, and University of Kent at Canterbury (UK). The U.S. Department of Defense (DoD) Space Test Program (STP) has assumed the responsibility for having the system manifested and deployed on the International Space Station (ISS), and then having it retrieved and returned to Earth after one to two years. LAD-C will attempt to utilize the ISS as a scientific platform to characterize the near-Earth meteoroid and orbital debris environment in the size regime where little data exist. In addition to meteoroid and orbital debris sample return, the acoustic sensors will record impact time, location, signal strength, and acoustic waveform data of the largest collected samples. A good time-dependent meteoroid and orbital debris flux estimate can be derived. Analysis of the data will also enable potential source identification of some of the collected samples. This dynamical link can be combined with laboratory composition analysis of impact residuals extracted from aerogel to further our understanding of orbital debris population, and the sources of meteoroids, asteroids and comets.

Liou, J.-C.↗

CHESS 2025: Waveform LiDAR data from NEON AOP surveys

This dataset provides Level 1 (L1) full-waveform light detection and ranging (LiDAR) data collected for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). These data were acquired to enable characterization of vegetation structure and other three-dimensional features of the land surface, and to evaluate structural changes that may have occurred between a prior LiDAR acquisition in 2018 and the 2025 overflight. Waveform LiDAR data can provide more detailed information about objects on the ground than discrete point clouds typically do, and they are often used for granular target segmentation and characterization of subcanopy vegetation. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. LiDAR data were acquired using the Optech Galaxy Prime Airborne LiDAR Terrain Mapper onboard the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP). These are the primary waveform LiDAR data delivered by NEON and are provided per flightline in compressed Pulsewaves format, an open-source binary file standard. A Pulsewaves object comprises a two files: a pulse (.pls) file, which stores the geographic origin, outgoing vector, and metadata for every laser pulse emitted by the scanner, and a wave file (.wvs), which stores the sequential amplitude samples of the outgoing pulse and the returning signals. The files are published here in their compressed forms (.plz, .wvz). All waveform data were processed following the theoretical workflow described in the NEON L0-to-L1 Waveform LiDAR Algorithm Theoretical Basis Document (Krause and Goulden 2022a); however, the Pulsewaves output format differs from a legacy format described in that document. Waveform amplitude samples are recorded at 1 nanosecond intervals. All coordinates are provided in meters. Horizontal coordinates are referenced in Universal Transverse Mercator (UTM) zone 13N and the World Geodetic System (WGS) 1984 ensemble datum. Elevations are referenced to Geoid12A. Waveform data for the UPTA survey area were collected without incident and the published records are complete. However, both the ALMO and CRBU collections experienced issues that resulted in incomplete data for those areas. On collection day 2018-06-16 a hardware failure caused the waveform digitizer to lose data from the eastern edge of the ALMO site (Figure 22). The waveform data for flightlines 2–20 could not be extracted from the digitizer, and the data proved unrecoverable. As a result, a portion of the site does not have coverage with waveform data. Although no hardware failure was observed during collection over the CRBU area, final waveform files generated by vendor software contained only ~25% of the expected number of return pulses. After discovery, NEON initiated troubleshooting with the vendor. The root cause of the data ablation had not been identified at the time of publication. Additional data will be published in an update to this package if further recovery proves successful. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Advanced Containerless Processing Technology

Breadboards for high temperature containerless processing systems are to be developed, the principles of operation are to be studied, the performance is to be characterized, the limitations identified, and the influence of the acoustic field on the samples established. The subjects to be addressed are experimental and theoretical studies of: (1) acoustic positioning and manipulation capabilities in a high temperature gradient environment (from 26 C to 990 C); (2) acoustic waveforms, harmonic contents, power transfer, sample transport and stability associated with high temperature gradient system; (3) high temperature ground based levitation systems which will allow melting, processing, and solidifying samples without crucibles in the laboratory, (4) KC-135 and laboratory tests of various acoustic geometries which may have spherical applications in the Materials Processing in Space Program; and (5) provide technical information to Acoustics Containerless Experimental System (ACES) engineering team and establish the operation conditions for ACES.

Wang, T. G.↗

Analysis of shockless dynamic compression data on solids to multi-megabar pressures: Application to tantalum

Magnetically-driven, planar shockless-compression experiments to multi-megabar pressures were performed on tantalum samples using a stripline target geometry. Free-surface velocity waveforms were measured in 15 cases; nine of these in a dual-sample configuration with two samples of different thicknesses on opposing electrodes, and six in a single-sample configuration with a bare electrode opposite the sample. Details are given on the application of inverse Lagrangian analysis (ILA) to these data, including potential sources of error. The most significant source of systematic error, particularly for single-sample experiments, was found to arise from the pulse-shape dependent free-surface reflected wave interactions with the deviatoric-stress response of tantalum. This could cause local, possibly temporary, unloading of material from a ramp compressed state, and thus multi-value response in wave speed that invalidates the free-surface to in-material velocity mapping step of ILA. By averaging all 15 data sets, a final result for the principal quasi-isentrope of tantalum in stress-strain was obtained to a peak longitudinal stress of 330 GPa with conservative uncertainty bounds of ±4.5% in stress. The result agrees well with a tabular equation of state developed at Los Alamos National Laboratory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System and method for instantaneous power decomposition and estimation

A system disaggregates and estimates power consumption of electric loads powered by a single electrical outlet. The system includes a processor having a routine; a current sensor cooperating with the processor to measure samples for one line cycle of an aggregated current waveform for the electric loads powered by the single electrical outlet; and a voltage sensor cooperating with the processor to measure samples for the one line cycle of a voltage waveform for the electric loads powered by the single electrical outlet. The processor routine transfers the measured samples for the one line cycle of the aggregated current waveform and the voltage waveform into an aggregated voltage-current trajectory for the single electrical outlet, and provides an instantaneous decomposition of power consumption for a plurality of different categories of the electric loads from the aggregated voltage-current trajectory for the one line cycle.

Yang, Yi↗

EGS Collab Experiment 2: Microseismic Monitoring

This dataset contains continuous seismic waveform data recorded during stimulation and thermal circulation tests for the Enhanced Geothermal Systems (EGS) Collab Experiment #2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to study and validate models of geothermal systems by injecting high-pressure fluids into rock formations 1200-1500 meters below the surface, inducing microseismic events. The seismic monitoring system included 16 three-component accelerometers and a 24-channel hydrophone array, installed in boreholes surrounding the test area. Data were recorded at high sampling rates using a continuous waveform recording system to monitor seismic activity in real time. The dataset contains the raw data stored in binary format, with files named based on timestamps, and includes calibration certificates for some sensors to facilitate corrections to real units. Users are strongly advised to consult the accompanying detailed report, which outlines the experimental setup, sensor specifications, installation procedures, and data processing methods. The report also describes important nuances, such as the hardware filters on hydrophones, sensor calibration details, and the naming conventions for the recorded data. Proper use of this dataset may require familiarity with seismic data analysis tools, such as the Obspy Python package, and an understanding of the SEED naming conventions used for channel identification.

15 GEOTHERMAL ENERGY↗

Thickness, humidity, and polarization dependent ferroelectric switching and conductivity in Mg doped lithium niobate

Mg doped lithium niobate (Mg:LN) exhibits several advantages over undoped LN such as resistance to photorefraction, lower coercive fields, and p-type conductivity that is particularly pronounced at domain walls and opens up a range of applications, e.g., in domain wall electronics. Engineering of precise domain patterns necessitates well founded knowledge of switching kinetics, which can differ significantly from that of undoped LN. In this work, the role of humidity and sample composition in polarization reversal has been investigated under application of the same voltage waveform. Control over domain sizes has been achieved by varying the sample thickness and initial polarization as well as atmospheric conditions. In addition, local introduction of proton exchanged phases allows for inhibition of domain nucleation or destabilization, which can be utilized to modify domain patterns. Polarization dependent current flow, attributed to charged domain walls and band bending, demonstrates the rectifying ability of Mg:LN in combination with suitable metal electrodes that allow for further tailoring of conductivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sample-Clock Phase-Control Feedback

To demodulate a communication signal, a receiver must recover and synchronize to the symbol timing of a received waveform. In a system that utilizes digital sampling, the fidelity of synchronization is limited by the time between the symbol boundary and closest sample time location. To reduce this error, one typically uses a sample clock in excess of the symbol rate in order to provide multiple samples per symbol, thereby lowering the error limit to a fraction of a symbol time. For systems with a large modulation bandwidth, the required sample clock rate is prohibitive due to current technological barriers and processing complexity. With precise control of the phase of the sample clock, one can sample the received signal at times arbitrarily close to the symbol boundary, thus obviating the need, from a synchronization perspective, for multiple samples per symbol. Sample-clock phase-control feedback was developed for use in the demodulation of an optical communication signal, where multi-GHz modulation bandwidths would require prohibitively large sample clock frequencies for rates in excess of the symbol rate. A custom mixedsignal (RF/digital) offset phase-locked loop circuit was developed to control the phase of the 6.4-GHz clock that samples the photon-counting detector output. The offset phase-locked loop is driven by a feedback mechanism that continuously corrects for variation in the symbol time due to motion between the transmitter and receiver as well as oscillator instability. This innovation will allow significant improvements in receiver throughput; for example, the throughput of a pulse-position modulation (PPM) with 16 slots can increase from 188 Mb/s to 1.5 Gb/s.

Quirk, Kevin J.↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗