Search NASA⌕ Search

SEARCH · Search NASA

Results for “automated alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of X-ray Wavefront Sensing Techniques for Adaptive Optics Control at the Advanced Photon Source

The planning and construction of new and upgraded high-brightness X-ray synchrotron and free electron laser sources, such as the Advanced Photon Source upgrade project (APS-U), are driving numerous opportunities to advance X-ray science and technologies. At the same time, an increasing number of highly diverse beamline experiments demand wavefront-preserving adaptive X-ray optics with both high precision and flexibility. At the APS, significant effort has been devoted to developing next-generation adaptive and corrective optics combined with state-of-the-art at-wavelength wavefront sensing techniques and an intelligent feedback control system for the automation and self-alignment of beamline optical systems. This article reviews recent achievements in these areas at the APS. Further, these include the development of in-situ wavefront sensing, the application in active feedback control of ultra-precision deformable mirrors, and the exploration of non-invasive wavefront sensing techniques for adaptive optics and beamline diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Scattering Tests of Fundamental Theories of Transport Properties in the Critical Region

The objective of this program is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments have been severely limited on Earth by the presence of gravity which causes large density gradients in the sample when the compressibility diverges approaching the critical point. The goal is to measure decay rates deep in the critical region where the scaled wavevector is the order of 1000. This will require loading the sample to 0.01% of the critical density and taking data as close as 3 microKelvin to the critical temperature (Tc = 289.72 K). Other technical problems have to be addressed such as multiple scattering and the effect of wetting layers. The ability to avoid multiple scattering by using a thin sample (100 microns) was demonstrated, as well as a temperature history which can avoid wetting layers satisfactory temperature control and measurement, and accurate sample loading. Thus the questions of experimental art are solved leaving the important engineering tasks of mounting the experiment to maintain alignment during flight and automating the state-of-the-art temperature bridges for microcomputer control of the experiment.

Gammon, R. W.↗

High-throughput full-automatic synchrotron-based tomographic microscopy

At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 {micro}m to 7.4 {micro}m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 {micro}m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

43 PARTICLE ACCELERATORS↗

Experiment Automation with a Robot Arm using the Liquids Reflectometer Instrument at the Spallation Neutron Source

The Liquids Reflectometer instrument installed at the Spallation Neutron Source (SNS) enables observations of chemical kinetics, solid-state reactions and phase-transitions of thin film materials at both solid and liquid surfaces. Effective measurement of these behaviors requires each sample to be calibrated dynamically using the neutron beam and the data acquisition system in a feedback loop. Since the SNS is an intense neutron source, the time needed to perform the measurement can be the same as the alignment process, leading to a labor-intensive operation that is exhausting to users. An update to the instrument control system, completed in March 2013, implemented the key features of automated sample alignment and robot-driven sample management, allowing for unattended operation over extended periods, lasting as long as 20 hours. We present a case study of the effort, detailing the mechanical, electrical and software modifications that were made as well as the lessons learned during the integration, verification and testing process.

automated alignment↗

Automated registration of multispectral MR vessel wall images of the carotid artery

Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purpose of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and moving image after registration. Results: The average required manual translation per image slice was 1.33 mm. Translations were larger as the patient was longer inside the scanner. Manual alignment took 187.5 s per patient resulting in a mean surface distance of 0.271 ± 0.127 mm. After minimal user interaction to generate the mask in the fixed image, the remaining sequences are automatically registered with a computation time of 52.0 s per patient. The optimal registration strategy used a circular mask with a diameter of 10 mm, a 3D B-spline transformation model with a control point spacing of 15 mm, mutual information as image similarity metric, and the precontrast T1W TSE as fixed image. A mean surface distance of 0.288 ± 0.128 mm was obtained with these settings, which is very close to the accuracy of the manual alignment procedure. The exact registration parameters and software were made publicly available. Conclusions: An automated registration method was developed and optimized, only needing two mouse clicks to mark the start and end point of the artery. Validation on a large group of patients showed that automated image registration has similar accuracy as the manual alignment procedure, substantially reducing the amount of user interactions needed, and is multiple times faster. In conclusion, the authors believe that the proposed automated method can replace the current manual procedure, thereby reducing the time to analyze the images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alignment and Integration of Lightweight Mirror Segments

The optics for the International X-Ray Observatory (IXO) require alignment and integration of about fourteen thousand thin mirror segments to achieve the mission goal of 3.0 square meters of effective area at 1.25 keV with an angular resolution of five arc-seconds. These mirror segments are 0.4 mm thick, and 200 to 400 mm in size, which makes it difficult not to impart distortion at the sub-arc-second level. This paper outlines the precise alignment, permanent bonding, and verification testing techniques developed at NASA's Goddard Space Flight Center (GSFC). Improvements in alignment include new hardware and automation software. Improvements in bonding include two module new simulators to bond mirrors into, a glass housing for proving single pair bonding, and a Kovar module for bonding multiple pairs of mirrors. Three separate bonding trials were x-ray tested producing results meeting the requirement of sub ten arc-second alignment. This paper will highlight these recent advances in alignment, testing, and bonding techniques and the exciting developments in thin x-ray optic technology development.

Evans, Tyler↗

Improving the Concrete Crack Detection Process via a Hybrid Visual Transformer Algorithm

Inspections of concrete bridges across the United States represent a significant commitment of resources, given their biannual mandate for many structures. With a notable number of aging bridges, there is an imperative need to enhance the efficiency of these inspections. This study harnessed the power of computer vision to streamline the inspection process. Our experiment examined the efficacy of a state-of-the-art Visual Transformer (ViT) model combined with distinct image enhancement detector algorithms. We benchmarked against a deep learning Convolutional Neural Network (CNN) model. These models were applied to over 20,000 high-quality images from the Concrete Images for Classification dataset. Traditional crack detection methods often fall short due to their heavy reliance on time and resources. This research pioneers bridge inspection by integrating ViT with diverse image enhancement detectors, significantly improving concrete crack detection accuracy. Notably, a custom-built CNN achieves over 99% accuracy with substantially lower training time than ViT, making it an efficient solution for enhancing safety and resource conservation in infrastructure management. These advancements enhance safety by enabling reliable detection and timely maintenance, but they also align with Industry 4.0 objectives, automating manual inspections, reducing costs, and advancing technological integration in public infrastructure management.

42 ENGINEERING↗

Markov Random Field Based Automatic Image Alignment for ElectronTomography

Cryo electron tomography (cryo-ET) is the primary method for obtaining 3D reconstructions of intact bacteria, viruses, and complex molecular machines ([7],[2]). It first flash freezes a specimen in a thin layer of ice, and then rotates the ice sheet in a transmission electron microscope (TEM) recording images of different projections through the sample. The resulting images are aligned and then back projected to form the desired 3-D model. The typical resolution of biological electron microscope is on the order of 1 nm per pixel which means that small imprecision in the microscope's stage or lenses can cause large alignment errors. To enable a high precision alignment, biologists add a small number of spherical gold beads to the sample before it is frozen. These beads generate high contrast dots in the image that can be tracked across projections. Each gold bead can be seen as a marker with a fixed location in 3D, which provides the reference points to bring all the images to a common frame as in the classical structure from motion problem. A high accuracy alignment is critical to obtain a high resolution tomogram (usually on the order of 5-15nm resolution). While some methods try to automate the task of tracking markers and aligning the images ([8],[4]), they require user intervention if the SNR of the image becomes too low. Unfortunately, cryogenic electron tomography (or cryo-ET) often has poor SNR, since the samples are relatively thick (for TEM) and the restricted electron dose usually results in projections with SNR under 0 dB. This paper shows that formulating this problem as a most-likely estimation task yields an approach that is able to automatically align with high precision cryo-ET datasets using inference in graphical models. This approach has been packaged into a publicly available software called RAPTOR-Robust Alignment and Projection estimation for Tomographic Reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Navigating the maze: the impact of configurability in bioinformatics software

The bioinformatics software domain contains thousands of applications for automating tasks such as the pairwise alignment of DNA sequences, building and reasoning about metabolic models or simulating growth of an organism. Its end users range from sophisticated developers to those with little computational experience. In response to their needs, developers provide many options to customize the way their algorithms are tuned. Yet there is little or no automated help for the user in determining the consequences or impact of the options they choose. In this paper we describe our experience working with configurable bioinformatics tools. We find limited documentation and help for combining and selecting options along with variation in both functionality and performance. We also find previously undetected faults. We summarize our findings with a set of lessons learned, and present a roadmap for creating automated techniques to interact with bioinformatics software. We believe these will generalize to other types of scientific software.

McDevitt, Mikaela Cashman↗

An Online Dynamic Amplitude-Correcting Gradient Estimation Technique to Align X-ray Focusing Optics

High-brightness X-ray pulses, as generated at synchrotrons and X-ray free electron lasers (XFELs), are used in a variety of scientific experiments. At these facilities, measurements often require optical equipment, e.g Compound Refractive Lenses (CRLs) to be precisely aligned and focused. The lateral alignment of CRLs to a beamline requires precise positioning along four axes: two translational, and the two rotational. At a synchrotron, alignment is often accomplished manually. However, XFEL beamlines present a beam brightness that fluctuates stochastically, making manual alignment a time-consuming endeavor. Automation using simplex or classic stochastic descent often fails, given the errant gradient estimates. Herein we present a dynamic-amplitude correction to the usual gradient based on the combination of a generalized finite difference stencil and a time-dependent sampling pattern. Intensity is recorded periodically, then used to normalize numerical derivatives against fluctuations. Error expectation is analyzed, and efficacy is demonstrated on classic benchmarks. We provide a proof of concept by laterally aligning optics on a simulated XFEL beamline using data recorded at both synchrotron and XFEL facilities.

97 MATHEMATICS AND COMPUTING↗

Automation of Laser Plasma Focused Ion Beam Microscopy for Next-Gen Energy Materials

Automation can revolutionize the use of ultrafast laser ablation and plasma-focused ion beam (PFIB) techniques for high-throughput, reproducible cross-sectioning and various sample preparation in materials characterization. As these methods become essential for analyzing complex energy materials and next-generation devices, efficient, standardized workflows are needed to minimize variability and enhance precision. This work highlights our advancements in developing automated processes for sample preparation that integrates machine learning, workflow optimization, and large-scale data acquisition to improve efficiency and scalability in applications such as electrolyzers, photovoltaic cells, and microelectronics. To streamline cross-sectioning and lamella fabrication, we have implemented fully automated workflows that standardize laser ablation and PFIB milling sequences. These workflows incorporate pre-programmed protocols for material removal, alignment, and thinning, reducing user intervention and ensuring consistency across different sample types. Machine learning algorithms further enhance automation by predicting optimal milling strategies and adapting parameters based on material properties and sectioning requirements. This approach significantly improves throughput while maintaining the structural integrity of prepared samples for high-resolution imaging and analysis, including transmission electron microscopy. Beyond sample preparation, our automation platform enables the acquisition of large, high-resolution datasets through serial sectioning, image alignment, and 3D reconstruction. These automated routines facilitate multi-scale characterization, capturing structural and compositional details from the nanoscale to the device level. By reducing variability and increasing efficiency, our automated approach enhances defect analysis, failure diagnostics, and process optimization, accelerating advancements in materials research and device engineering.

36 MATERIALS SCIENCE↗

ADEPT: a domain independent sequence alignment strategy for gpu architectures

Bioinformatic workflows frequently make use of automated genome assembly and protein clustering tools. At the core of most of these tools, a significant portion of execution time is spent in determining optimal local alignment between two sequences. This task is performed with the Smith-Waterman algorithm, which is a dynamic programming based method. With the advent of modern sequencing technologies and increasing size of both genome and protein databases, a need for faster Smith-Waterman implementations has emerged. Multiple SIMD strategies for the Smith-Waterman algorithm are available for CPUs. However, with the move of HPC facilities towards accelerator based architectures, a need for an efficient GPU accelerated strategy has emerged. Existing GPU based strategies have either been optimized for a specific type of characters (Nucleotides or Amino Acids) or for only a handful of application use-cases. In this paper, we present ADEPT, a new sequence alignment strategy for GPU architectures that is domain independent, supporting alignment of sequences from both genomes and proteins. Our proposed strategy uses GPU specific optimizations that do not rely on the nature of sequence. We demonstrate the feasibility of this strategy by implementing the Smith-Waterman algorithm and comparing it to similar CPU strategies as well as the fastest known GPU methods for each domain. ADEPT’s driver enables it to scale across multiple GPUs and allows easy integration into software pipelines which utilize large scale computational systems. We have shown that the ADEPT based Smith-Waterman algorithm demonstrates a peak performance of 360 GCUPS and 497 GCUPs for protein based and DNA based datasets respectively on a single GPU node (8 GPUs) of the Cori Supercomputer. Overall ADEPT shows 10x faster performance in a node-to-node comparison against a corresponding SIMD CPU implementation. ADEPT demonstrates a performance that is either comparable or better than existing GPU strategies. We demonstrated the efficacy of ADEPT in supporting existing bionformatics software pipelines by integrating ADEPT in MetaHipMer a high-performance denovo metagenome assembler and PASTIS a high-performance protein similarity graph construction pipeline. Our results show 10% and 30% boost of performance in MetaHipMer and PASTIS respectively.

59 BASIC BIOLOGICAL SCIENCES↗

Apparatus for skidding sensitivity testing of energetic materials

A remote-operated apparatus for testing the detonation sensitivity of energetic materials is detailed. Using an air ram and rotating disk, the normal force and transverse velocity of the impact plane are controlled independently, enabling the exploration of varying impact conditions over a wide parameter space. A microcontroller local to the apparatus is used to automate apparatus operation and ensure temporal alignment of the impacting ram head with the rotating disk. Calculation of the firing parameters and issuing of operational commands are handled by a remote computer and relayed to the local microcontoller for execution at the hardware level. Finally, impact forces are taken from fast strain measurements obtained from gauges incorporated into the ram head. Infrared imaging of explosive samples provides insight to the peak thermal temperatures experienced at the sample surface during the impact event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

iBLAST: Incremental BLAST of new sequences via automated e-value correction

Search results from local alignment search tools use statistical scores that are sensitive to the size of the database to report the quality of the result. For example, NCBI BLAST reports the best matches using similarity scores and expect values (i.e., e-values) calculated against the database size. Given the astronomical growth in genomics data throughout a genomic research investigation, sequence databases grow as new sequences are continuously being added to these databases. As a consequence, the results (e.g., best hits) and associated statistics (e.g., e-values) for a specific set of queries may change over the course of a genomic investigation. Thus, to update the results of a previously conducted BLAST search to find the best matches on an updated database, scientists must currently rerun the BLAST search against the entire updated database, which translates into irrecoverable and, in turn, wasted execution time, money, and computational resources. To address this issue, we devise a novel and efficient method to redeem past BLAST searches by introducing iBLAST. iBLAST leverages previous BLAST search results to conduct the same query search but only on the incremental (i.e., newly added) part of the database, recomputes the associated critical statistics such as e-values, and combines these results to produce updated search results. Our experimental results and fidelity analyses show that iBLAST delivers search results that are identical to NCBI BLAST at a substantially reduced computational cost, i.e., iBLAST performs (1 + δ )/ δ times faster than NCBI BLAST, where δ represents the fraction of database growth. We then present three different use cases to demonstrate that iBLAST can enable efficient biological discovery at a much faster speed with a substantially reduced computational cost.

59 BASIC BIOLOGICAL SCIENCES↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

Minimizing Error Potential Using Computer Applications - 18498

Many Savannah River Site (SRS) liquid waste facility operations depend upon repetitive engineering calculations and operator actions. Although these calculations and actions are formalized in technical reports and paper procedures, they can still be vulnerable to data entry errors, calculation errors, equipment alignment errors, and occasional changes caused by different people performing these activities. Savannah River Remediation (SRR) is using computer automation to reduce these error precursors by standardizing repetitive calculations and by performing plant alignment checks for repetitive operation processes. Data entry can be automated, calculation methodologies can be standardized, and computers can check to see that predefined plant conditions exist before equipment operation. In addition to improving quality, the time required for these activities to generate technical reports, to perform independent reviews, and to perform equipment alignment checks can be significantly reduced. In the case of operator-performed calculations, error precursors involve distractions that can occur over a multi-page paper procedure, confusing displays and controls from equipment, mathematical errors, complacency, and unfamiliarity with the procedure among many others. Repetitive engineering calculations suffer from similar error precursors and are often compounded by high workloads, lack of proficiency, lack of standard methodology, mental shortcuts, and biases. Web-based computer applications can eliminate many of these precursors through standardization. Calculation methods are fixed, inputs are fixed, and computer checks can highlight potentially wrong inputs and outputs. Automated calculations are performed almost instantaneously once input is provided. Operators and engineers can spend more time focusing on the results than on the process to achieve the results. Similarly, when operators use repetitive procedures involving equipment manipulation, the same error precursors apply. Automated operation sequences and equipment checks can be programmed into the distributed control system to provide standard operating processes that reduce and eliminate error precursors. This paper describes how SRR incorporates Human Performance Improvement (HPI) principles when automating calculations and operation processes. Computer applications will be reviewed in detail, highlighting the software development life-cycle that includes requirements gathering, prototyping, design, development, testing, and implementation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rack Insertion End Effector (RIEE) automation

NASA is developing a mechanism to manipulate and insert Racks into the Space Station Logistic modules. The mechanism consists of the following: a base with three motorized degrees of freedom, a 3 section motorized boom that goes from 15 to 44 feet in length, and a Rack Insertion End Effector (RIEE) with 5 hand wheels for precise alignment. The robotics section was tasked with the automation of the RIEE unit. In this report, for the automation of the RIEE unit, application of the Perceptics Vision System was conceptually developed to determine the position and orientation of the RIEE relative to the logistic module, and a MathCad program is written to display the needed displacements for precise alignment and final insertion of the Rack. The uniqueness of this report is that the whole report is in fact a MathCad program including text, derivations, and executable equations with example inputs and outputs.

Malladi, Narasimha↗

Control and automation of the Pegasus multi-point Thomson scattering system

A new control system for the Pegasus Thomson scattering diagnostic has recently been deployed to automate the laser operation, data collection process, and interface with the system-wide Pegasus control code. Automation has been extended to areas outside of data collection, such as manipulation of beamline cameras and remotely controlled turning mirror actuators to enable intra-shot beam alignment. Additionally, the system has been upgraded with a set of fast (∼1 ms) mechanical shutters to mitigate contamination from background light. Modification and automation of the Thomson system have improved both data quality and diagnostic reliability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗